Your browser doesn't support javascript.
loading
Compression of the True Lumen after Starting CPB during the Operation of Type A Aortic Dissection / 日本心臓血管外科学会雑誌
Article in Ja | WPRIM | ID: wpr-366340
Responsible library: WPRO
ABSTRACT
We present a rare case of acute type A dissection which developed compression of the true lumen after starting cardiopulmonary bypass (CPB) with femoral arterial return. In this case, the entry was located in the proximal descending thoracic aorta, and the dissection expanded up to the ascending aorta in a retrograde direction. After starting CPB, the false lumen suddenly enlarged and the true lumen was compressed. We observed those changes by intraoperative transesophageal echocardiography, so the perfusion was stopped immediately. A long arterial cannula (Wessex) was inserted from the left ventricular apex with the tip of the cannula remaining in the true lumen of the ascending aorta, and antegrade perfusion was restarted. After that we could maintain adequate extracorporeal perfusion and the replacement of the total aortic arch was completed uneventfully.
Full text: 1 Index: WPRIM Language: Ja Journal: Japanese Journal of Cardiovascular Surgery Year: 1997 Type: Article
Full text: 1 Index: WPRIM Language: Ja Journal: Japanese Journal of Cardiovascular Surgery Year: 1997 Type: Article