Your browser doesn't support javascript.
loading
Total Arch Replacement for Blunt Traumatic Aortic Injury Associated with Spine Fractures: A Case Report / 日本心臓血管外科学会雑誌
Article in Ja | WPRIM | ID: wpr-366716
Responsible library: WPRO
ABSTRACT
An 80-year-old man was transferred to our hospital because of blunt traumatic aortic arch injury caused by a fall. Computed tomography (CT) revealed a pseudoaneurysm and mediastinal hematoma around the aortic arch, right hemothorax, left hemopneumothorax, lung contusion and spine fractures. His hemodynamic condition was stable but he required mechanical ventilation because of severe hypoxemia. Surgery was postponed until twelve days after the injury, when his lung function improved and active bleeding decreased. During surgery we found that the intimal disruption extended to half of the circumference of the aortic arch, and thus performed total arch replacement under deep hypothermic circulatory arrest and selective cerebral perfusion. The patient suffered respiratory failure and pneumonia postoperatively as well as multiple cerebral infarctions. He was referred to a rehabilitation center on postoperative day 130.
Full text: 1 Index: WPRIM Language: Ja Journal: Japanese Journal of Cardiovascular Surgery Year: 2001 Type: Article
Full text: 1 Index: WPRIM Language: Ja Journal: Japanese Journal of Cardiovascular Surgery Year: 2001 Type: Article