Staged Approach Using Proximal Open-Stenting Technique and Distal Open Repair for the Treatment of Extensive Thoracic Aortic Aneurysms / 日本心臓血管外科学会雑誌
Japanese Journal of Cardiovascular Surgery
; : 139-142, 2017.
Article
in Ja
| WPRIM
| ID: wpr-379315
Responsible library:
WPRO
ABSTRACT
<p>A 50-year-old man with an extensive thoracic aortic aneurysm underwent staged surgery which consisted of preceding total aortic arch replacement with the frozen elephant trunk technique using J Graft Open Stent Graft<sup>®</sup>, followed by open thoracoabdominal aortic aneurysm repair. During the second operation, the descending aorta was cross clamped along with the preexisting stent graft, and Dacron graft was anastomosed directly to the stent graft using a running 4-0 monofilament suture. The anastomosis site was then covered with a short piece of Dacron graft identical with the stent graft in size to secure hemostasis. We herein discuss our approach in this complex case, focusing on prevention of inadvertent events such as deformation of the preexisting stent graft and unexpected bleeding.</p>
Search on Google
Index:
WPRIM
Language:
Ja
Journal:
Japanese Journal of Cardiovascular Surgery
Year:
2017
Type: