Analytical performance of three cysteine proteinase inhibitor c reagents applied in the automatic biochemistry analyzer / 中华检验医学杂志
Chinese Journal of Laboratory Medicine ; (12): 561-567, 2011.
Article in Chinese | WPRIM | ID: wpr-417258
ABSTRACT
Objective To validate the analytical performance of three Cys C reagents with particle-enhanced turbidimetric immunoassay(PETIA) method used on the automatic biochemistry analyzer for preliminary clinical application.Methods The performance of three Cys C reagents (labeled as A, B, C) with PETIA method from Shanghai Jing Yuan Co., Beijing Leadman Co. and Beijing Jiuqiang Co. on OlympusAU2700 automatic biochemistry analyzer were assessed.According to the standard of CLSI EP6-A, EP15-A and EP7-P, the precision, linearity range, disturbance (bilirubin, hemoglobin, chyle) were assessed, and compared with those of Cys C reagent based on particle-enhanced nephelometric immunoassay(PENIA) from Dade Behring Co.. The reference ranges for Cys C in serum of 120 healthy individual were evaluated.Results The within-run CVs of the three reagents (A, B and C) were 3.08%-3.2%, 2.3%-4.15% and 1.38%-1.53% respectively.The total CV in A, B and C were 3.29%-3.44%, 2.65%-5.18% and 1.67%-1.69% respectively, lower than the stated.Limits of quantitative determination (LOQ) of the three reagents were 0.41, 0.23 and 0.07 mg/L, basically meeting the testing requirement.The linearity range was 0.22-7.26 mg/L(r=0.996), 0.20-7.72 mg/L(r=0.999)and 0.20-7.62 mg/L(r=0.997)in the three reagents, which demonstrated a sound linear correlation. For interference tests, no remarkable interference (<±10%) of reagent C was detected when bilirubin≤684 μmol/L, hemoglobin≤9.7 g/L and Chyle turbidity≤6 200 FTU; and no significant interference of reagent B was found when bilirubin≤684 μmol/L, hemoglobin≤6.79 g/L and Chyle turbidity≤6 200 FTU; when bilirubin≤684 μmol/L, hemoglobin≤4.85 g/L and Chyle turbidity≤1 240 FTU reagent A was not interfered significantly. The comparison afte and before the high-speed centrifugation reveals that the average percentage of bias for reagents A, B, C measured Cys C in chylous serum samples of patients was -8.31%, 1.52%, 1.32%, respectively.In method comparison tests, the regression equations of the three reagents compared with Dade Behring PENIA Cys C reagent were as followsY=0.787X+0.492 (R2=0.976), Y=1.098X+0.137 (R2=0.982) and Y=1.037X+0.249 (R2=0.996), respectively. Agreement rates of the high Cys C in reagent A, B, C and Dade Behring Cys C reagent were 80% (Kappa=0.615,P=0.000), 100% (Kappa=1.000,P=0.000), 91.2% (Kappa=0.824,P=0.000); While for reference range of preliminary clinical assessment, diagnosis coincidence rate of reagent A increased to 98.8% (Kappa=0.974,P=0.000). Conclusions When used in automatic biochemical analyzer, the three Cys C reagent with PETIA showed high precision,sensitivity, and sound correlation with Dade Behring PENIA reagents.The three reagents are all able to meet clinical test requirements, nevertheless, anti-interference capability were diffierent and the reference range should be further validated.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Laboratory Medicine Year: 2011 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Laboratory Medicine Year: 2011 Type: Article