Your browser doesn't support javascript.
loading
Molecular MRI evaluation of acute thrombus in carotid artery in rabbits / 中国医学影像技术
Chinese Journal of Medical Imaging Technology ; (12): 414-417, 2010.
Article in Chinese | WPRIM | ID: wpr-471237
ABSTRACT
Objective To assess the value of a fibrin-targeted contrast agent (EP-2104R) for MR detection of thrombus, and to compare this modality with non-contrast-enhanced (NCE) MRI and Gd-DTPA injection at acute period after thrombus generation. Methods Thrombus was induced with external injury and stasis in 5 rabbits. MRI was performed before and after contrast agent injection at 6.0 h after injury, and the MRI findings were compared with that of histopathologically examinations. Results EP-2104R enhanced MRI accurately detected thrombus, which was superior to both NCE and Gd-DTPA injection (P<0.001). Gd-DTPA injection was not associated with improvement of thrombus detection. Conclusion Being a fibrin-targeted MR contrast agent for in vivo detection of acute thrombus, EP-2104R is superior to NCE MRI and Gd-DTPA injection.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Medical Imaging Technology Year: 2010 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Medical Imaging Technology Year: 2010 Type: Article