Comparatic study of different radiotherapy techniques in the treatment of hepatocellular ;carcinoma / 中国医学装备
China Medical Equipment ; (12): 70-73, 2016.
Article in Zh | WPRIM | ID: wpr-498598
Responsible library: WPRO
ABSTRACT
Objective:To compare the dosimetry of three-dimensional conformal radiotherapy (3D-CRT), intensity modulated radiotherapy (IMRT) and simplified intensity modulated radiotherapy (sIMRT) for hepato-cellular cancer, in order to put forward the best radiation therapy plan. Methods:10 patients with hepatocellular carcinoma were designed 4 fields radiotherapy plan of 3D-CRT, IMRT and sIMRT, prescribed dose 50 Gy/20f, compared the target dose of homogeneity index (HI) and conformal index, monitor unit (MU), the dose of organ at risk (OAR) of the 3 different radiotherapy techniques. Results: Compared sIMRT respectively with 3DCRT and IMRT, target optimum conformal index IMRT was the optimal, sIMRT was the second, and 3D-CRT was the worst. The differences were statistically significant among them (t=4.95, t=4.32;P<0.05). Target homogeneity index IMRT was the optimal, sIMRT was the second, and 3D-CRT was the worst. The differences were statistically significant among them (t=3.42, t=4.02;P<0.05 statistically significant). The low dose irradiation area of normal liver, time of therapy, the child field number, the total MU and the protection of OAR:3D-CRT
Key words
Full text: 1 Index: WPRIM Language: Zh Journal: China Medical Equipment Year: 2016 Type: Article