Your browser doesn't support javascript.
loading
Determination of Isoniazid and Acetylisoniazid Concentration in Human Plasma by HPLC / 中国药房
China Pharmacy ; (12)2005.
Article in Chinese | WPRIM | ID: wpr-525214
ABSTRACT

OBJECTIVE:

To establish a HPLC method for determination of the plasma concentrations of isoniazid(INH)and its metabolite acetyl-isoniazid(AcINH).

METHODS:

Trichloroacetic acid was added to plasma to precipitate protein,then the supernatant was divided into 2 parts,distilled water was added to the first part;while HCl was added to the second one,after incubated at 80℃for 1 hour,1%cinnamaldehyde was added to perform precolumn derivatization.The column was Hypersil BDS C 18 ,the mobil phase was eluted with0.02mol/L NaH 2 PO 4 (pH=4.0)-acetontrile(69∶31)and detected wave-length was 340nm,the flow fate was1ml/min.

RESULTS:

INH detectable concentration showed a good linear correlation in the range of 0.57~145.88?mol/L,the average recoveries of INH and AcINH were 101.1% and 101.5% respectively,the average RSD within or between day was less than 10%.

CONCLUSION:

The present method is applicable to monitoring of INH plasma concentration and the study of metabolism capacity of N-acetyltransferase.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2005 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2005 Type: Article