Simultaneous Determination of Camphor and Menthol in Compound Diphenhydramine Liniment by GC / 中国药房
China Pharmacy ; (12): 4297-4298,4299, 2015.
Article in Chinese | WPRIM | ID: wpr-605205
ABSTRACT

OBJECTIVE:

To establish a method for simultaneous determination of camphor and menthol in Compound diphen-hydramine liniment.

METHODS:

GC was performed on the column of Agilent 19095N-123 INNOWAX capillary column,column temperature was 120 ℃,injection volume temperature was 220 ℃,FID detector was used with the temperature of 260 ℃,carrier gas was nitrogen gas,flow of column was 6.0 ml/min,air was 450 ml/min,hydrogen gas was 40 ml/min,split ratio was 20∶1 and injection volume was 1 μl.

RESULTS:

The linear range of mass concentration was 0.612-6.12 mg/ml(r=0.999 9)for camphor and 0.593-5.93 mg/ml(r=0.999 9)for menthol;RSDs of precision,stability and reproducibility tests were lower than 2%;the recov-eries were respectively 98.0%-100.7%(RSD=1.0%,n=6)and 98.7%-100.7%(RSD=0.7%,n=6).

CONCLUSIONS:

The meth-od is simple,accurate and reproducible,and can be used for the contents determination of camphor and menthol in Compound di-phenhydramine liniment.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2015 Type: Article