Clinical analysis of the shaping ability of Hyflex CM rotary NiTi files in curved root canals / 实用口腔医学杂志
Journal of Practical Stomatology
; (6): 410-413, 2017.
Article
in Zh
| WPRIM
| ID: wpr-610094
Responsible library:
WPRO
ABSTRACT
60 curved root canals of permanent teeth with angles of curvature ranging from 15°to 40°(Schneider's methodology)were prepared using the instruments of Hyflex CM(HC) and ProTaper(PT) Universal respectively(n=30).Using standardized pre-and post-instrumentation paralleling periapical radiographs,canal curvature was determined by image analysis software and the clinical shaping effect of Hyflex CM and ProTaper rotary NiTi files were compared.The canal curvature in group HC and PT decreased by 4.54°±3.25° and 5.63°±3.84° respectively(between pre-and post-treatment in both groups,P0.05).Hyflex CM can meet the clinical necessity for the instrumentation of curved root canals.
Full text:
1
Index:
WPRIM
Language:
Zh
Journal:
Journal of Practical Stomatology
Year:
2017
Type:
Article