Objective To investigate the feasibilty of the disposable tracheotomy tube as trocar in the electronic bronchoscope instead of thoracoscope. Methods 86 patients with effusion of unknown origin undergoing medical tho-racoscopy from January 2015 to October 2015, 59 male (68.6%) and 27 female (31.4 %), mean age (49.00 ± 20.00) years (15 ~ 83) years, were randomly divided into two groups, Tracheostomy tube group (group T) and Conventional chest tube group (group C). Group T uses disposable cannula tracheostomy tube as trocar, and group C received conventional medical thoracoscopy chest tube. Then compare the positive rate of pathological diagnosis, operation time, inspection fees, and other adverse reactions between the two groups. Results 40 cases (93.0%) in group T were confirmed diagnosis, including 8 cases of lung pleural metastasis, 31 cases of erculous pleurisy, 1 case of empyema, while 4 cases of unknown diagnosis (7.0%). 33 cases (76.7%) in group C were confirmed diagnosis, in-cluding 4 cases of lung pleural metastasis, 29 cases of tuberculous pleurisy, while 10 cases of unknown diagnosis (23.3 %). The difference was statistically significant between the two groups ( < 0.05). Operative time in group T was (23.86 ± 2.45) minutes, while in group C was (29.88 ± 3.67) minutes, the difference was statistically significant ( <0.05). While the complication rate was no significant difference. Conclusions It is demonstrated that the dispos-able tracheotomy tube as trocar in the electronic bronchoscope instead of thoracoscope which can shorten the opera-tion time, improve the diagnosis rate, reduce costs, worthy of promoting.
Full text:
1
Index:
WPRIM
Language:
Zh
Journal:
China Journal of Endoscopy
Year:
2016
Type:
Article