Your browser doesn't support javascript.
loading
Comparison of adenosine and exercise stress 201Tl myocardial perfusion imaging for diagnosing coronary heart disease in women / 中华核医学杂志
Article in Zh | WPRIM | ID: wpr-642467
Responsible library: WPRO
ABSTRACT
Objective To compare the diagnostic value of adenosine and exercise stress myocardial perfusion imaging (MPI) for detecting coronary heart disease (CHD) in women. Methods One hundred and thirty-eight patients with CHD were randomly divided into two groups: adenosine stress group (n = 69)and exercise stress group (n = 69). All patients underwent myocardial SPECT evaluation. Coronary angiography (CAG), referred as "gold standard" , was performed in each patient within 1 week before or after MPI. The diagnostic value of the two stress MPI was compared with χ2 test or Fisher's exact test. Results In adenosine stress group, the sensitivity, negative predictive value and accuracy were 88.2% (45/51),72.7% (16/22), 88.4% (61/69), respectively, which were not significantly different from those of the exercise stress group (91.7% (44/48), 66.7% (8/12), 81.2% (52/64); χ2 =0. 571, 0. 714, 0.249, P >0.05). However, the false positive rate of adenosine stress (11.1%, 2/18) was significantly lower than that of exercise stress (50.0%, 8/16), P = 0.023. Conclusions Adenosine and exercise stress MPI have similar value for CHD diagnosis in women, however, adenosine stress MPI may have an advantage of low false positive rate.
Key words
Full text: 1 Index: WPRIM Type of study: Diagnostic_studies Language: Zh Journal: Chinese Journal of Nuclear Medicine Year: 2011 Type: Article
Full text: 1 Index: WPRIM Type of study: Diagnostic_studies Language: Zh Journal: Chinese Journal of Nuclear Medicine Year: 2011 Type: Article