Intestinal Obstruction Due to Incarcerated Hernia at CAPD Catheter Insertion Site
Journal of the Korean Surgical Society
;
: 79-81, 2004.
Article
in Korean
| WPRIM
| ID: wpr-65116
ABSTRACT
Patients who have undergone peritoneal dialysis can frequently experience abdominal wall complications, such as hernia due to increased intraabdominal pressure and peritoneal leakage. However, no case of incarcerated abdominal wall hernia through catheter insertion site of CAPD has yet been reported Recently the authors experienced a case of intestinal obstruction due to an incarcerated hernia at the catheter insertion site of CAPD. We report this case and present a literature review.