Minimum 4 Year Follow-up Results of Metalon Metal Hip Resurfacing Arthroplasty / 대한정형외과학회잡지
The Journal of the Korean Orthopaedic Association
; : 695-702, 2006.
Article
in Ko
| WPRIM
| ID: wpr-652857
Responsible library:
WPRO
ABSTRACT
PURPOSE: To report the minimum 4 year follow up results of metal on metal hip resurfacing arthroplasty. MATERIALS AND METHODS: 39 hips from 36 patients, who received hip resurfacing from November 1998 to September 2001 and were followed up for at least 4 years, were enrolled in this study. The average age was 45 years (28-69 years) and the average follow up period was 51.9 months (48-82 months). A clinical evaluation was performed with the Harris Hip Score and gait analysis postoperatively. A radiologic evaluation was performed regularly after surgery using anteroposterior and lateral simple radiographs. The post-operative cobalt-chrome serum concentration was measured and compared using 21 cases of ceramic-on-ceramic total hip arthroplasty as a control group. RESULTS: The Harris Hip Score improved from 61 points (31-74) preoperatively to 96 points (85-99) postoperatively. There were no cases of acetabular loosening, and the average angle of femoral insert to the shaft was 136 degrees with 22 hips (61.1%) being within 130-140 degrees. The 4 year follow-up survival rate was 97.4%. The serum cobalt and chrome levels were higher than the control group (p<0.05). CONCLUSION: Hip resurfacing showed excellent survival rate after a short-term follow-up, but still requires a long-term evaluation with more cases and further metal ion release studies.
Key words
Full text:
1
Index:
WPRIM
Main subject:
Arthroplasty
/
Survival Rate
/
Follow-Up Studies
/
Cobalt
/
Arthroplasty, Replacement, Hip
/
Gait
/
Hip
/
Acetabulum
Type of study:
Observational_studies
/
Prognostic_studies
Limits:
Humans
Language:
Ko
Journal:
The Journal of the Korean Orthopaedic Association
Year:
2006
Type: