ABSTRACT
Objective To observe the safety and efficiency of SpO_2 -Allen's test in peri -puncture radial artery cannulation for invasive blood monitor. Methods 50 patients were selected for the radial artery cannulation in surgical intensive care unit(SICU). All of them were still sober. All of the patients were examined by SpO_2 -Allen's test and Allen's test before radial artery cannulation, 3 days after puncture and after pulling out the cannula. Resluts The results of Allen's test of 42 patients were negative,while those of 49 patients were negative in SpO_2 - Allen's test. Statistics difference existed between group of SpO_2 - Allen's text and group of Allen's text(P

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Journal of Medical Research Year: 2006 Type: Article