ABSTRACT
Development of luminex-based solid phase assays enables advanced measurement of HLA antibody with sensitivity, specificity, and increasing knowledge of unacceptable antigens. In this review, we described the principle of the luminex-based assay and its current applications for organ transplantation including C1q assay, calculated panel reactive antibody, and virtual cross-matching. We also discussed the technical aspects and limitations for clinical utilization. The variables related to measurement of HLA antibody specificities and their clinical relevance remain unclear, therefore the interpretation of results requires comprehensive knowledge and clinical information in critical cases.
Subject(s)
Key words
Full text: 1 Index: WPRIM Main subject: Transplantation / Immunoassay / Organ Transplantation / Sensitivity and Specificity / Transplants / Antibody Specificity Type of study: Diagnostic_studies Language: Ko Journal: The Journal of the Korean Society for Transplantation Year: 2015 Type: Article