ThestudyoflowerextremityCTangiographybylowradiationdoseandlow contrastmedium withsinogram-affirmediterativereconstruction / 实用放射学杂志
Journal of Practical Radiology
; (12): 638-642, 2019.
Article
in Zh
| WPRIM
| ID: wpr-752413
Responsible library:
WPRO
ABSTRACT
Objective ToevaluateimagequalityoflowerextremityCTAoflowradiationdoseandlowcontrastmediumprotocol withsinogram-affirmediterativereconstruction(SAFIRE).Methods Thisstudyincluded116patientswhoreferredtolowerextremityCT angiographyusinga128-sliceCTscanner.Accordingtovoltageandcontrastmediumconcentration,patientsweredividedintofour groups:100kV+350mgI/mL,100kV+320mgI/mL,100kV+300mgI/mL,80kV+CarekV+300mgI/mL.Imagereconstructionunderwent conventionalfilteredback-projection (FBP)andSAFIREtechniqueineachprotocoltocompareSNR,CNRofarterialimages.Results Comparisonoftwosubgroupsinthesamegroup,SAFIREhadsignificantlyhigherimagequalitythanFBP.Comparisonamong groupsshowed:imagequalityinlowcontrastmediumandlowradiationdoseSAFIREgroupcouldreachsimilarorbetterthanthatin higherdoseFBPgroup.SAFIREcouldreduceimagenoiseandimproveimageSNRandCNR.Conclusion InlowerextremityCTA, 80kV+CarekV,300mgI/mLcontrastmediumwithSAFIREexamineprotocolcouldreducecontrastmediumconcentrationandradiationdose withnocompromiseddiagnosticdemand.
Full text:
1
Index:
WPRIM
Language:
Zh
Journal:
Journal of Practical Radiology
Year:
2019
Type:
Article