Determination of obeticholic acid in rat plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS) / 药学学报
Yao Xue Xue Bao
; (12): 271-277, 2018.
Article
in Zh
| WPRIM
| ID: wpr-779873
Responsible library:
WPRO
ABSTRACT
A simple and sensitive method was developed for quantitation of obeticholic acid in rat plasma with liquid chromatography-tandem mass spectrometry (LC-MS/MS). After liquid-liquid extraction by methyl tert-butyl ether, the chromatographic separation was carried out on an ACE Excel 2 Super C18 column (50 mm×2.1 mm ID, 1.7 μm) with a gradient mobile phase consisting of acetonitrile and 2 mmol·L-1 ammonium formate at a flow rate of 0.2 mL·min-1. The quantitation analysis was performed using multiple reaction monitoring (MRM) at the specific ion transitions of m/z 418.9[M-H]-→401.2 for obeticholic acid and m/z 469.0[M-H]-→ 425.2 for glycyrrhetinic acid (internal standard) in the negative ion mode with electrospray ionization (ESI) source. This validated LC-MS/MS method yielded a good linearity over the range of 5 -5 000 ng·mL-1 with the lower limit of quantitation (LLOQ) of 5 ng·mL-1. The intra and inter-assay precisions (RSD) were all less than 9.82% and the accuracy (RE) was within ±6.90%. The extraction recovery of obeticholic acid was from 85.4% to 88.5%, and the matrix effect of obeticholic acid ranged from 78.9% to 82.5%. Stability test suggest that obeticholic acid in rat plasma was stable for 24 h on workbench, up to 1 month at -70℃, and after three cycles of freeze-thaw. Extracted samples were stable for more than 24 h in an auto-sampler at 6℃. The precision was less than 7.25%, and the accuracy was within ±11.2%, after being diluted 10 times by blank rat plasma. The method has been successfully applied to a pharmacokinetic study of obeticholic acid in rats following oral administration at the dose of 2.5 mg·kg-1.
Full text:
1
Index:
WPRIM
Language:
Zh
Journal:
Yao Xue Xue Bao
Year:
2018
Type:
Article