Simultaneous Determination of 4 Components in Huanshao Capsules by HPLC / 中国药房
China Pharmacy
; (12): 2508-2511, 2020.
Article
in Zh
| WPRIM
| ID: wpr-829359
Responsible library:
WPRO
ABSTRACT
OBJECTIVE:To estab lish a me thod for simultaneous determination of morroniside ,loganin,echinacoside and acteoside in Huanshao capsules. METHODS :HPLC method was adopted. The determination was performed on Zhongpuhong RD-C18 column with mobile phase consisted of acetonitrile- 0.1% formic acid solution (gradient elution )at the flow rate of 1.0 mL/min. The detection wavelength was set at 240 nm (morroniside,loganin) and 330 nm (echinacoside,acteoside). The column temperature was set at 35 ℃,and sample size was 10 μL. RESULTS:The linear range were 5.29-105.80 μg/mL for morroniside, 4.49-89.88 mg/L for loganin ,16.26-325.25 mg/L for echinacoside and 16.31-326.25 mg/L for acteoside ,r values were 0.999 9. RSDs of precision ,stability (24 h),reproducibility and durability tests were all lower than 2.0% . The recoveries were 94.34% -96.23%(RSD=0.81% ,n=6),97.04% -98.89%(RSD=0.73% ,n=6),96.23% -98.08%(RSD=0.82% ,n=6), 95.40%-98.47%(RSD=1.23%,n=6),respectively. The contents of above 4 components in 11 batches of Huanshao Capsules were 0.190-0.704,0.439-0.857,2.723-4.475 and 0.589-1.035 mg/g,respectively. CONCLUSIONS :Established method is specific , precise and can be used for content determination of 4 components in Huanshao capsules.
Full text:
1
Index:
WPRIM
Language:
Zh
Journal:
China Pharmacy
Year:
2020
Type:
Article