Your browser doesn't support javascript.
loading
Comparison of Protein Binding Rate of DPP- 4 Inhibitor LGT- 6 in Different Species of Plasma / 中国药房
China Pharmacy ; (12): 1728-1733, 2021.
Article in Chinese | WPRIM | ID: wpr-882144
ABSTRACT
OBJECTIVE:To establish the method for determining protein binding rate of dipeptidyl peptidase- 4 inhibitor LGT- 6 in different species of plasma ,and to compare their difference. METHODS :By equilibrium dialysis ,LGT-6(3,30,300,3 000 nmol/L)was equilibrated in ratmonkey and human plasma (i. e. internal dialysis solution )for 48 h,using phosphate buffer as the external dialysis solution. The concentration of LGT- 6 in internal and external dialysis solution was determined by UPLC-MS/MS using tolbutamide as internal standard ,and the plasma protein binding rate was calculated. The determination was performed on ACQUITY UPLC HSS T 3 column with water (containing 0.01% formic acid )-acetonitrile(containing 0.01% formic acid )as mobile phase at the flow rate of 0.6 mL/min. The column temperature was 40 ℃,and the sample size was 2 μL. The ion source was electrospray ion source ,and the multiple ion monitoring mode was used to carry out positive ionization scanning. The ion pairs for quantitative analysis were m/z 487.0→434.3(LGT-6),m/z 271.1→172.0(internal standard ),respectively. RESULTS :At the concentrations of 3,30,300,and 3 000 nmol/L,the protein binding rates of LGT- 6 in rat plasma were (96.25±0.97)%,(84.16± 1.24)%,(78.25±0.61)%,(66.63±0.95)%;the protein protein binding rates in monkey plasma were (98.54±0.58)%,(87.27± 1.01)%,(79.35±0.86)%,(66.69±0.54)%;the protein binding rates in human plasma were (99.40±1.03)%,(84.48± 1.15)%,(77.62±0.77)%,(66.93±0.48)%. At the same concentration ,the protein binding rates of LGT- 6 in ratmonkey and human plasma had no significant difference (P>0.05). In the same species of plasma ,there were significant differences in the plasma protein binding rates of different concentration of LGT-6 among those groups (P<0.05),and it decreased with 才〔2016〕4015) the increase of drug concentration. CONCLUSIONS : The method for the determination of plasma protein binding rate of LGT-6 is successfully established. The data revealed that the protein binding rate of LGT- 6 is concentration-dependent , there was no obvious spec ies difference on protein binding rates of LGT- 6 in ratmonkey and human plasma under the same concentration.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2021 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: China Pharmacy Year: 2021 Type: Article