Your browser doesn't support javascript.
loading
Puncture assisted by a "TINAVI" orthopaedic robot versus freehand puncture in vertebroplaty for osteoporotic vertebral compression fracture of the upper thoracic vertebra / 中华创伤骨科杂志
Chinese Journal of Orthopaedic Trauma ; (12): 20-26, 2021.
Article in Chinese | WPRIM | ID: wpr-884216
ABSTRACT

Objective:

To compare the clinical efficacy between puncture assisted by a "TINAVI" orthopaedic robot versus freehand puncture in vertebroplaty for osteoporotic vertebral compression fracture(OVCF) of the upper thoracic vertebra.

Methods:

A retrospective study was conducted of the 19 patients (20 vertebral bodies) with OVCF of the upper thoracic vertebra who had been treated at Department of Spine Surgery, Honghui Hospital from January 2018 to March 2019 by robotic vertebroplasty (robot group) and of another 21 counterpart patients (21 vertebral bodies) who had been treated by conventional vertebroplasty from January 2016 to December 2017 (freehand group). Puncture was conducted by a "TINAVI" orthopaedic robot in the robotic vertebroplasty but freehand in the conventional vertebroplasty. The robot group had 5 males and 14 females, aged from 62 to 88 years; the freehand group had 6 males and 15 females, aged from 64 to 83 years. The 2 groups were compared in terms of operation time, bone cement volume, postoperative complications (cement leakage, infection and embolism), visual analogue scale (VAS), Oswestry disability index (ODI), anterior height (AH) and kyphosis angulation (KA) of the injured vertebra at day 1 and last follow-up after surgery.

Results:

The 2 groups were comparable because there were no significant differences between them in the preoperative general data ( P>0.05). Vertebroplasty via unilateral puncture approach was completed uneventfully in the 19 patients (20 vertebral bodies) in the robot group and in the 21 patients (21 vertebral bodies) in the freehand group. The 40 patients were followed up for 6 to 12 months (mean, 8.3 month). The operation time [(37.9±8.2) min], bone cement volume [(2.3±0.9) mL] and rate of cement leakage (10.0%, 2/20) in the robot group were all significantly less or lower than those in the freehand group [(46.2±9.4) min, (4.2±1.3) mL and 42.9% (9/21)] ( P<0.05). No infection or embolism was observed in either group. There were no significant differences between the 2 groups in VAS, ODI, AH or KA of the injured vertebra at day 1 or last follow-up after surgery ( P>0.05).

Conclusion:

In vertebroplaty for OVCF of the upper thoracic vertebra, compared with conventional freehand puncture, puncture assisted by a "TINAVI" orthopaedic robot can lead to satisfactory clinical efficacy because it reduces operation time, volume of bone cement injection, and thus incidence of bone cement leakage.
Full text: Available Index: WPRIM (Western Pacific) Type of study: Observational study Language: Chinese Journal: Chinese Journal of Orthopaedic Trauma Year: 2021 Type: Article