Your browser doesn't support javascript.
loading
Added Value of Chemical Exchange-Dependent Saturation Transfer MRI for the Diagnosis of Dementia
Korean j. radiol ; Korean j. radiol;: 770-781, 2021.
Article in En | WPRIM | ID: wpr-902477
Responsible library: WPRO
ABSTRACT
Objective@#Chemical exchange-dependent saturation transfer (CEST) MRI is sensitive for detecting solid-like proteins and may detect changes in the levels of mobile proteins and peptides in tissues. The objective of this study was to evaluate the characteristics of chemical exchange proton pools using the CEST MRI technique in patients with dementia. @*Materials and Methods@#Our institutional review board approved this cross-sectional prospective study and informed consent was obtained from all participants. This study included 41 subjects (19 with dementia and 22 without dementia). Complete CEST data of the brain were obtained using a three-dimensional gradient and spin-echo sequence to map CEST indices, such as amide, amine, hydroxyl, and magnetization transfer ratio asymmetry (MTR asym) values, using six-pool Lorentzian fitting. Statistical analyses of CEST indices were performed to evaluate group comparisons, their correlations with gray matter volume (GMV) and Mini-Mental State Examination (MMSE) scores, and receiver operating characteristic (ROC) curves. @*Results@#Amine signals (0.029 for non-dementia, 0.046 for dementia, p = 0.011 at hippocampus) and MTR asym values at 3 ppm (0.748 for non-dementia, 1.138 for dementia, p = 0.022 at hippocampus), and 3.5 ppm (0.463 for non-dementia, 0.875 for dementia, p = 0.029 at hippocampus) were significantly higher in the dementia group than in the non-dementia group. Most CEST indices were not significantly correlated with GMV; however, except amide, most indices were significantly correlated with the MMSE scores. The classification power of most CEST indices was lower than that of GMV but adding one of the CEST indices in GMV improved the classification between the subject groups. The largest improvement was seen in the MTR asym values at 2 ppm in the anterior cingulate (area under the ROC curve = 0.981), with a sensitivity of 100 and a specificity of 90.91. @*Conclusion@#CEST MRI potentially allows noninvasive image alterations in the Alzheimer’s disease brain without injecting isotopes for monitoring different disease states and may provide a new imaging biomarker in the future.
Full text: 1 Index: WPRIM Type of study: Diagnostic_studies / Observational_studies / Prognostic_studies Language: En Journal: Korean j. radiol Year: 2021 Type: Article
Full text: 1 Index: WPRIM Type of study: Diagnostic_studies / Observational_studies / Prognostic_studies Language: En Journal: Korean j. radiol Year: 2021 Type: Article