Your browser doesn't support javascript.
loading
Quantitative Evaluation of Gastrocnemius Medialis Stiffness During Passive Stretching Using Shear Wave Elastography in Patients with Parkinson’s Disease: A Prospective Preliminary Study
Korean Journal of Radiology ; : 1841-1849, 2021.
Article in English | WPRIM | ID: wpr-918201
ABSTRACT
Objective@#To prospectively investigate the feasibility of shear wave elastography (SWE) as a new quantitative and objective method for evaluating the stiffness of the gastrocnemius medialis (GM) muscle during passive stretching in patients with Parkinson’s disease (PD). @*Materials and Methods@#SWE of the GM muscle was performed in 28 patients with PD [13 female and 15 male; mean age ± standard deviation (SD) 63.0 ± 8.5 years] and 12 healthy controls (5 female and 7 male; mean age ± SD 59.3 ± 6.4 years) during passive ankle rotation. A Young’s modulus-ankle angle curve was constructed. The GM slack angle and baseline Young’s modulus (E 0) were compared between the markedly symptomatic and mildly symptomatic sides of patients with PD, and healthy controls. Additionally, the correlation between the GM slack angle and the severity of rigidity, and the observer reproducibility of SWE in determining the GM slack angle were evaluated. @*Results@#The GM slack angle was smaller on both the markedly and mildly symptomatic sides in patients with PD than in healthy controls (mean ± SD of -29.13° ± 3.79° and -25.65° ± 3.39°, respectively, vs. -21.22° ± 3.52°; p < 0.001 and p = 0.006, respectively). Additionally, in patients with PD, the GM slack angle on the markedly symptomatic side was smaller than that on the mildly symptomatic side (p = 0.003). The E 0 value was lower on both the markedly and mildly symptomatic sides in patients with PD than in healthy controls (mean ± SD of 10.11 ± 2.85 kPa and 10.08 ± 1.88 kPa, respectively, vs. 12.23 ± 1.02 kPa; p = 0.012 and p < 0.001, respectively). However, no significant difference was found between the markedly and mildly symptomatic sides in patients with PD (p = 0.634). A negative linear relationship was observed between the GM slack angle and lower limb rigidity score on the markedly symptomatic side in patients with PD (r = -0.719; p < 0.001). The intraclass correlation coefficients for observer reproducibility of SWE ranged from 0.880 to 0.951. @*Conclusion@#The slack angle determined by SWE may be a useful quantitative and reproducible method for evaluating muscle stiffness in patients with PD.
Full text: Available Index: WPRIM (Western Pacific) Language: English Journal: Korean Journal of Radiology Year: 2021 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: English Journal: Korean Journal of Radiology Year: 2021 Type: Article