Your browser doesn't support javascript.
loading
Effects of different sputum suction pressure on intracranial pressure of severe craniocerebral injury patients / 中国实用护理杂志
Article in Zh | WPRIM | ID: wpr-930723
Responsible library: WPRO
ABSTRACT
Objective:To explore the best negative pressure standard of sputum aspiration in patients with severe craniocerebral injury, so as to achieve the best sputum aspiration effect and maintain relatively stable intracranial pressure.Methods:Totally 120 patients with severe craniocerebral injury admitted to the Department of Neurosurgery of Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School from January to December 2019 were selected by convenience sampling method. According to the random number table method, patients were divided into 4 different negative pressure sputum aspiration groups: 75 mmHg (1 mmHg=0.133 kPa) group, 100 mmHg group, 150 mmHg group, 200 mmHg group, with 30 patients in each group. The levels of intracranial pressure and SpO 2, sputum cleaning time and mucosal injury were observed and compared in 4 groups: 1 min before sputum aspiration, 1 min after sputum aspiration and during sputum aspiration. Results:Comparison of intracranial pressure and SpO 2 in sputum aspiration among the four groups: intracranial pressure in 200 mmHg group was (22.23 ± 4.80) mmHg, which was higher than 75 mmHg group (16.33 ± 2.71) mmHg, 100 mmHg group (17.70 ± 2.32) mmHg, 150 mmHg group (17.20 ± 2.11) mmHg ( q=8.29, 6.58, 7.23), and SpO 2 was 0.906 ± 0.048, which was lower than 0.956 ± 0.013, 0.946 ± 0.018, 0.952 ± 0.023 in the other three groups ( q=7.81, 6.08, 6.69), with statistical significance (all P<0.01). There were statistically significant differences in intracranial pressure ( F=10.55) and SpO 2 ( F=36.57) among the four groups 1 min after sputum aspiration ( P<0.01);the 200 mmHg group had the highest intracranial pressure (15.63 ± 3.64) mmHg; the 100 mmHg group was (12.50 ± 1.48) mmHg and 150 mmHg group was (12.60 ± 1.00) mmHg, which had lower intracranial pressure than the 75 mmHg group (14.03 ± 2.86) mmHg. The sputum cleaning time was (35.53 ± 5.71) s in 75 mmHg group which was the longest and the shortest in 200 mmHg group (24.27 ± 3.22) s, with statistical significance among the four groups ( F=47.81, P<0.01). The incidence of airway mucosal injury in 200 mmHg group was 33.33% (10/30),which was higher than that in the other three groups, and the difference was statistically significant ( χ2=15.41, P<0.01). Conclusions:For patients with severe craniocerebral injury, artificial airway sputum viscosityⅠ-Ⅱ degree, suction negative pressure of 100-150 mmHg can better maintain the stability of intracranial pressure, control the decline of SpO 2 and prevent the damage of airway mucosa, and effectively reduce the adverse effects of sputum aspiration on patients with severe craniocerebral injury.
Key words
Full text: 1 Index: WPRIM Language: Zh Journal: Chinese Journal of Practical Nursing Year: 2022 Type: Article
Full text: 1 Index: WPRIM Language: Zh Journal: Chinese Journal of Practical Nursing Year: 2022 Type: Article