Determination of acetochlor and its metabolites in urine using liquid chromatography-tandem mass spectrometry / 中华劳动卫生职业病杂志
Article in Zh | WPRIM | ID: wpr-935814
Responsible library: WPRO
ABSTRACT
Objective: A method for the determination of acetochlor and its metabolites in urine by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was established. Methods: After cleaned-up by a HLB extraction cartridges, the urine was eluted with 1% acetic acid acetonitrile solution. The target compounds were separated by ACQUITY UPLC®HSS T3 Column (2.1 mm×100 mm×1.8 μm) by using 1% formic acid solution and acetonitrile as mobile phase with gradient elution program, and analyzed in positive electrospray ionization mode by liquid chromatography tandem mass spectrometry. Results: All the target compounds showed good linear relationships in the range of 1-50 μg/L, and the correlation coefficients (r) were higher than 0.997. The recoveries rates at three different spiked levels for all target compounds in blank matrices were 107.6%-129.1%, and the relative standard deviations (RSD) were 1.5%-9.9% (n=6) . The limits of detection and quantitation of the method were 0.04-0.11 μg/L and 0.15-0.42 μg/L, respectively, and target substances were detected in all urine samples from occupational exposure workers to acetochlor. Conclusion: This method is suitable for rapid screening and analysis of acetochlor and metabolites in urine with the advantages of accuracy, rapidity, simplicity, high sensitivity and good specificity.
Subject(s)
Key words
Full text: 1 Index: WPRIM Main subject: Acetonitriles / Toluidines / Chromatography, High Pressure Liquid / Chromatography, Liquid / Tandem Mass Spectrometry / Solid Phase Extraction Limits: Humans Language: Zh Journal: Chinese Journal of Industrial Hygiene and Occupational Diseases Year: 2022 Type: Article
Full text: 1 Index: WPRIM Main subject: Acetonitriles / Toluidines / Chromatography, High Pressure Liquid / Chromatography, Liquid / Tandem Mass Spectrometry / Solid Phase Extraction Limits: Humans Language: Zh Journal: Chinese Journal of Industrial Hygiene and Occupational Diseases Year: 2022 Type: Article