Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros


Ano de publicação
Intervalo de ano de publicação
1.
J Anal Toxicol ; 27(6): 377-80, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-14516492

RESUMO

An original, simple, specific, and rapid high-performance liquid chromatography assay for the determination of clofazimine in human plasma is presented. The procedure consists of extracting the drug and the internal standard (medazepam) from 0.5 mL plasma with dichloromethane/diisopropyl ether (1:1, v/v) at pH 3.0, after precipitating the proteins with methanol. The drugs were then quantitated on a reversed-phase C8 using a mobile phase consisting of a mixture of methanol/0.25 N sodium acetate buffer at pH 3.0 (74:26, v/v). The flow-rate and wavelength were set at 1 mL/min and 286 nm, respectively. The precision, linearity, and limit of quantitation of the method were within acceptable limits. The method was considered adequate and could be applied in studies involving blood level monitoring and pharmacokinetics in leprosy patients.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Clofazimina/farmacocinética , Monitoramento de Medicamentos/métodos , Hansenostáticos/farmacocinética , Hanseníase/metabolismo , Clofazimina/uso terapêutico , Feminino , Humanos , Hansenostáticos/uso terapêutico , Hanseníase/tratamento farmacológico , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
s.l; s.n; 2003. 4 p. ilus, tab.
Não convencional em Inglês | Sec. Est. Saúde SP, HANSEN, Hanseníase, SESSP-ILSLACERVO, Sec. Est. Saúde SP | ID: biblio-1241393

RESUMO

An original, simple, specific, and rapid high-performance liquid chromatography assay for the determination of clofazimine in human plasma is presented. The procedure consists of extracting the drug and the internal standard (medazepam) from 0.5 mL plasma with dichloromethane/diisopropyl ether (1:1, v/v) at pH 3.0, after precipitating the proteins with methanol. The drugs were then quantitated on a reversed-phase C8 using a mobile phase consisting of a mixture of methanol/0.25 N sodium acetate buffer at pH 3.0 (74:26, v/v). The flow-rate and wavelength were set at 1 mL/min and 286 nm, respectively. The precision, linearity, and limit of quantitation of the method were within acceptable limits. The method was considered adequate and could be applied in studies involving blood level monitoring and pharmacokinetics in leprosy patients.


Assuntos
Feminino , Masculino , Humanos , Clofazimina , Cromatografia Líquida de Alta Pressão , Hansenostáticos , Hanseníase , Monitoramento de Medicamentos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA