RESUMO

AIMS: A robotic navigation system (RNS, Hansen™) has been developed as an alternative method of performing ablation for atrial fibrillation (AF). Despite the growing application of RNS-guided pulmonary vein isolation (PVI), its consequences and mechanisms of subsequent AF recurrences are unknown. We investigated the acute procedural success and persistence of PVI over time after robotic PVI and its relation to clinical outcome. METHODS AND RESULTS: Sixty-four patients (60.7 ± 9.8 years, 53 male) with paroxysmal AF underwent robotic circumferential PVI with 3-dimensional left atrial reconstruction (NavX™). A voluntary repeat invasive electrophysiological study was performed 3 months after ablation irrespective of clinical course. Robotic PVI was successful in all patients without complication (fluoroscopy time: 23.5 [12-34], procedure time: 180 [150-225] minutes). Fluoroscopy time demonstrated a gradual decline but was significantly reduced after the 30th patient following the introduction of additional navigation software (34 [29-45] vs 12 [9-17] minutes; P < 0.001). A repeat study at 3 months was performed in 63% of patients and revealed electrical conduction recovery in 43% of all PVs. Restudied patients without AF recurrence (n = 28) showed a significantly lower number of recovered PVs (1 (0-2) vs 2 (2-3); P = 0.006) and a longer LA-PV conduction delay than patients with AF recurrences (n = 12). Persistent block of all PVs was associated with freedom from AF in all patients. At 3 months, 67% of patients were free of AF, while reablation of recovered PVs led to an overall freedom from AF in 81% of patients after 1 year. CONCLUSION: Robotic PVI for PAF is safe, effective, and requires limited fluoroscopy while yielding comparable success rates to conventional ablation approaches with PV reconduction as a common phenomenon associated with AF recurrences.


Assuntos
Fibrilação Atrial/cirurgia , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Robótica/métodos , Cirurgia Assistida por Computador/métodos , Telemedicina/métodos , Fibrilação Atrial/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Resultado do Tratamento
2.
J Cardiovasc Electrophysiol ; 21(1): 6-12, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19793149

RESUMO

BACKGROUND: Recently, a nonmagnetic robotic navigation system (RN, Hansen-Sensei) has been introduced for remote catheter manipulation. OBJECTIVE: To investigate the influence of RN combined with intuitive 3-dimensional mapping on the fluoroscopy exposure to operator and patient during pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) in a prospective randomized trial. METHODS: Sixty patients were randomly assigned to undergo PVI either using a RN guided (group 1; n = 30, 20 male, 62 +/- 7.7 years) or conventional ablation approach (group 2; n = 30, 14 male, 61 +/- 7.6 years). A 3-dimensional mapping system (NavX) was used in both groups. RESULTS: Electrical disconnection of the ipsilateral pulmonary veins (PVs) was achieved in all patients. Use of RN significantly lowered the overall fluoroscopy time (9 +/- 3.4 vs 22 +/- 6.5 minutes; P < 0.001) and reduced the operator's fluoroscopy exposure (7 +/- 2.1 vs 22 +/- 6.5 minutes; P < 0.001). The difference in fluoroscopy duration between both groups was most pronounced during the ablation part of the procedure (3 +/- 2.4 vs 17 +/- 6.3 minutes; P < 0.001). The overall procedure duration tended to be prolonged using RN without reaching statistical significance (156 +/- 44.4 vs 134 +/- 12 minutes, P = 0.099). No difference regarding outcome was found during a midterm follow-up of 6 months (AF freedom group 1 = 73% vs 77% in group 2 [P = 0.345]). CONCLUSION: The use of RN for PVI seems to be effective and significantly reduces overall fluoroscopy time and operator's fluoroscopy exposure without affecting mid-term outcome after 6-month follow-up.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Doses de Radiação , Robótica/métodos , Cirurgia Assistida por Computador/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA