Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-37609746

RESUMO

Background There is emerging evidence of a relationship between atopic dermatitis (AD) and allergic contact dermatitis (ACD), though the data available are scarce with conflicting viewpoints. We explored the occurrence of contact hypersensitivity among children with atopic dermatitis by patch testing them with the Indian standard series and tried to correlate the presence of contact hypersensitivity with the clinical severity of AD in these children. Methods In this single-centre, cross-sectional study, children between 6 months and 12 years diagnosed with atopic dermatitis were included and patch tested with the Indian standard series. Outcome parameters were the proportion of patients having positive patch-test reactions, the proportion of positive patch-test reactions for each allergen and factors associated with patch test positivity in atopic dermatitis. Results Of the 136 patients, 80 were boys. The mean age of the study population was 5.6 ± 3.2 years. Twenty-eight (20.6%) patients had patch test positivity at 96 h. Fragrance mix was the commonest allergen, followed by potassium dichromate, cobalt chloride hexahydrate and nickel. SCORing atopic dermatitis (SCORAD) was significantly higher in patients with positive patch tests as compared to patients with negative patch tests (P = 0.009). Conclusion Greater disease severity in atopic dermatitis was found to be associated with patch test positivity. Limitations Inability to establish relevance in about 50% of the patients was a limitation of our study. Follow-up data regarding the impact of allergen avoidance is not available.


Assuntos
Dermatite Alérgica de Contato , Dermatite Atópica , Criança , Masculino , Humanos , Pré-Escolar , Feminino , Dermatite Atópica/diagnóstico , Dermatite Atópica/epidemiologia , Testes do Emplastro/métodos , Estudos Transversais , Estudos Retrospectivos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Alérgenos , Gravidade do Paciente
2.
Indian J Dermatol Venereol Leprol ; 89(4): 622-625, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36461809

RESUMO

Patch test helps in identifying the allergen causing allergic contact dermatitis. Proper identification of the site of individual patch test allergen is very important for identifying the positive allergen. In this article, various techniques for markings patch test sites are discussed.


Assuntos
Dermatite Alérgica de Contato , Humanos , Testes do Emplastro/métodos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/etiologia , Alérgenos
3.
Indian J Dermatol Venereol Leprol ; 88(2): 188-195, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33969657

RESUMO

BACKGROUND: The reliability of patch testing with expired Indian standard patch test kits has been not evaluated before. METHODS: Thirty adults (men:women 25:5) with allergic contact dermatitis were divided into three groups of ten patients each for patch testing by Finn chamber® method using Indian standard patch test kits having expiry in 2016, 2015 and 2014. The results were compared with those from a new kit with 2018 expiry. RESULTS: Ten patients in group-1, eight patients in group-2 and seven patients in group-3 developed positive reactions of identical intensities and mostly from identical allergens from all four kits. The major contact allergens eliciting positive reactions of identical intensities were parthenium in nine, five and three patients, colophony in four, one and zero patients, fragrance mix in three, three and one patients, thiuram mix in three, one and one patients, and paraphenylene diamine in two, one and three patients from group-1,-2, and -3, respectively. LIMITATIONS: Small number of patients in each group remains the major limitation of the study. Whether or not these results can be extrapolated with patch test results from other similar patch test kits available across countries also needs confirmation. CONCLUSION: The patch test allergens can be used beyond labeled expiry dates but needs confirmation by a few large studies and using other available patch test kits. This is important as the relevance of patch test results for individual allergen in this scenario may remain debatable requiring careful interpretation.


Assuntos
Dermatite Alérgica de Contato/diagnóstico , Testes do Emplastro , Adulto , Idoso , Alérgenos/análise , Feminino , Humanos , Índia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Fatores de Tempo
6.
Indian J Dermatol Venereol Leprol ; 84(2): 153-156, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29393081

RESUMO

BACKGROUND: Kumkum, made with turmeric and slaked lime along with colour enhancing dyes is known to cause allergic contact dermatitis. The possible contact allergens in kumkum include turmeric, Sudan-1, 4-aminoazobenzene, brilliant lake red R and cananga oil. We report patch test results among patients with suspected contact hypersensitivity to kumkum. OBJECTIVE: To identify the allergen causing kumkum induced allergic contact dermatitis by patch testing and to advise patients about organic kumkum which doesnot contain colour enhancing dyes. METHODS: Eighteen patients with suspected contact hypersensitivity to kumkum were patch tested with undiluted kumkum, undiluted turmeric, Sudan-1 (95%), 4-aminoazobenzene and allergens of the Indian Standard Series. RESULTS: Of the 18 patients, 14 patients had patch test positivity to kumkum and 4 had a negative reaction to kumkum. Patch test with other suspected contact allergens showed positive reaction to turmeric in 4 patients, Sudan-1 in 3 patients and 4-aminoazobenzene in 2 patients. Among the allergens of the Indian Standard Series, positivity to nickel and fragrance mix was seen in 5 and 2 patients respectively. Positive reaction to PPD, chlorocresol and parthenium was seen in 1 patient each. LIMITATION: Small sample size. CONCLUSION: Allergic contact dermatitis to kumkum occurs both due to the dyes (added for enhancing the colour) and turmeric. All patients with suspected allergic contact dermatitis should be patch tested with kumkum, turmeric and dyes, based on which alternative non-allergic material could be advised. Kumkum dermatitis can also occur due to various other allergens, for which too patch testing should be done.


Assuntos
Hidróxido de Cálcio/efeitos adversos , Corantes/efeitos adversos , Curcuma/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Adulto , Idoso , Dermatite Alérgica de Contato/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes do Emplastro/métodos , Adulto Jovem
7.
Indian J Dermatol Venereol Leprol ; 83(5): 525-535, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28485305

RESUMO

Occupational dermatoses contribute to a significant portion of work-related diseases, especially in Asia, where a major portion of the workforce is in the unorganized sector. This review article is focussed on the frequency and pattern of occupational skin diseases reported across Asian countries and type of allergens implicated in different occupations. The literature was searched systematically using key words 'occupational dermatoses,' 'occupational skin disease' and name of each Asian country. Ninty five full-text articles were considered relevant and evaluated. Some of the dermatoses seen in industrial workers in Asian countries are similar to those in Western countries, including dermatoses due to chromate in construction and electroplating workers, epoxy resin, and chromate in painters, wood dust in workers in the furniture industry, azo dyes in textile workers and formaldehyde and chromates in those working in the leather and dyeing industries, dermatoses in domestic workers, chefs and health-care workers. Dermatoses in workers engaged in agriculture, beedi (tiny cigars) manufacture, agarbatti (incense sticks) production, fish processing, carpet weaving, sanitation and those working in coffee plantations and coal mines appear to be unique to Asian countries. Recognition of clinical patterns and geographic variations in occupational skin diseases will provide an impetus to further strengthen future research in these areas, as well as improving their management.


Assuntos
Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Ocupacional/diagnóstico , Dermatite Ocupacional/epidemiologia , Agroquímicos/efeitos adversos , Ásia/epidemiologia , Dermatite Alérgica de Contato/prevenção & controle , Dermatite Ocupacional/prevenção & controle , Humanos , Resíduos Industriais/efeitos adversos , Exposição Ocupacional/efeitos adversos , Testes do Emplastro/métodos , Praguicidas/efeitos adversos
8.
Indian J Dermatol Venereol Leprol ; 82(6): 645-650, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27451929

RESUMO

BACKGROUND: Hair dye is one of the most common causes of allergic contact dermatitis. The main allergen has been identified as para-phenylenediamine. To prevent the recurrence of contact dermatitis to para-phenylenediamine, patients should discontinue the use of para-phenylenediamine-containing hair dye products. However, many patients are unable to discontinue their use for cosmetic or social reasons. Sometimes, they continue to have symptoms even after switching to so-called "less allergenic" hair dyes. OBJECTIVES: To evaluate the safety of 15 commercially available hair dye products in patients with allergic contact dermatitis due to para-phenylenediamine. METHODS: We performed patch tests using 15 hair dyes that were advertised as "hypoallergenic," "no para-phenylenediamine" and "non-allergenic" products in the market. RESULTS: Twenty three patients completed the study and 20 (87.0%) patients had a positive patch test reaction to at least one product. While four (26.7%) hair dye products contained para-phenylenediamine, 10 (66.7%) out of 15 contained m- aminophenol and 7 (46.7%) contained toluene-2,5-diamine sulfate. Only one product did not elicit a positive reaction in any patient. LIMITATIONS: Small sample size and possibility of false-positive reactions. CONCLUSIONS: Dermatologists should educate patients with allergic contact dermatitis to para-phenylenediamine about the importance of performing sensitivity testing prior to the actual use of any hair dye product, irrespective of how it is advertised or labelled.


Assuntos
Corantes/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Tinturas para Cabelo/efeitos adversos , Testes do Emplastro/métodos , Fenilenodiaminas/efeitos adversos , Idoso , Dermatite Alérgica de Contato/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , República da Coreia/epidemiologia
9.
Artigo em Inglês | MEDLINE | ID: mdl-27279294

RESUMO

Since their introduction, topical corticosteroids have become indispensable in the treatment of various dermatoses. Hydrocortisone was the first compound. Modifications in the basic structure generated in vivo activity and thus different topically active compounds were discovered. Apart from the Stoughton vasoconstrictor assay, various other methods are used for potency assessment of topical corticosteroids. Topical corticosteroides are classified based upon potency and action of these molecules. Mechanism of action at the cellular level and indications of topical corticosteroid use have been discussed. Various adverse effects often occur as an extension of their activity combined with inappropriate usage. Tachyphylaxis and contact allergy are potential problems in clinical practice. Newer compounds with improved risk-benefit ratio are available.


Assuntos
Corticosteroides/administração & dosagem , Fármacos Dermatológicos/administração & dosagem , Dermatologia/métodos , Dermatopatias/tratamento farmacológico , Administração Tópica , Corticosteroides/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/prevenção & controle , Fármacos Dermatológicos/efeitos adversos , Dermatologia/tendências , Humanos , Dermatopatias/diagnóstico
12.
Artigo em Inglês | MEDLINE | ID: mdl-26261149

RESUMO

BACKGROUND: Dental restorative materials containing silver-mercury compounds have been known to induce oral lichenoid lesions. OBJECTIVES: To determine the frequency of contact allergy to dental restoration materials in patients with oral lichenoid lesions and to study the effect of removal of the materials on the lesions. RESULTS: Forty-five patients were recruited in three groups of 15 each: Group A (lesions in close contact with dental materials), Group B (lesions extending 1 cm beyond the area of contact) and Group C (no topographic relationship). Thirty controls were recruited in two groups of 15 individuals each: Group D (oral lichenoid lesions but no dental material) and Group E (dental material but no oral lichenoid lesions). Patch tests were positive in 20 (44.5%) patients. Mercury was the most common allergen to elicit a positive reaction in eight patients, followed by nickel (7), palladium (5), potassium dichromate (3), balsam of Peru, gold sodium thiosulphate 2 and tinuvin (2) and eugenol (1), cobalt chloride (1) and carvone (1). Seven patients elicited positive response to more than one allergen. In 13 of 20 patients who consented to removal of the dental material, complete healing was observed in 6 (30%), marked improvement in 7 (35%) and no improvement in 7 (35%) patients. Relief of symptoms was usually observed 3 months after removal. LIMITATIONS: Limited number of study subjects and short follow up after removal/replacement of dental restoration materials are the main limitations of this study. CONCLUSION: Contact allergy to amalgam is an important etiologic factor in oral lichenoid lesions and removal of restorative material should be offered to patients who have lesions in close proximity to the dental material.


Assuntos
Materiais Dentários/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/etiologia , Erupções Liquenoides/induzido quimicamente , Erupções Liquenoides/diagnóstico , Mucosa Bucal/patologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mucosa Bucal/efeitos dos fármacos , Testes do Emplastro/métodos , Estudos Prospectivos
13.
Artigo em Inglês | MEDLINE | ID: mdl-26087081

RESUMO

BACKGROUND: Chronic paronychia, earlier considered to be an infection due to Candida, is currently being considered as a dermatitis of the nail fold. Irritant, allergic and protein contact dermatitis are the suggested major pathogenic mechanisms. Hypersensitivity to Candida is more likely to be the etiology, rather than the infection itself. AIMS: To assess the clinico-etiological profiles of patients with chronic paronychia and to determine the role of contact sensitization and hypersensitivity to Candida. METHODS: All consecutive patients of chronic paronychia attending the dermatology outpatient department (OPD) were assessed for risk factors, number of nails affected, clinical presentation and presence of fungus, patch tested for contact allergy and prick tested for hypersensitivity to Candida allergen. RESULTS: A total of 80 patients of chronic paronychia were recruited into our study. There was female preponderance (66 patients, 82.5%), with the most common group affected being housewives (47 patients, 58.8%). Frequent washing of hands (64 patients, 80%) was the most common risk factor. Fungal culture was positive in 56.1% (41 patients), the predominant species cultured was Candida albicans (15 patients, 36.5%). Patch testing with Indian standard series was positive in 27.1% patients (19 out of 70 patients tested), with nickel being the most common allergen. Prick test with Candida allergen was positive in 47.6% patients (31 out of 65 patients tested). LIMITATIONS: Prick test and patch test provide indirect evidence of hypersensitivity, with inherent limitations. CONCLUSION: Our study shows that chronic paronychia is probably a form of hand dermatitis associated with prolonged wet work, and that there is a higher incidence of contact sensitization and Candida hypersensitivity in these patients.


Assuntos
Candida/isolamento & purificação , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Paroniquia/diagnóstico , Paroniquia/epidemiologia , Adulto , Candida/imunologia , Doença Crônica , Dermatite Alérgica de Contato/imunologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Unhas/imunologia , Unhas/patologia , Paroniquia/imunologia , Testes do Emplastro/métodos
14.
Artigo em Inglês | MEDLINE | ID: mdl-25937142

RESUMO

BACKGROUND: Parthenium hysterophorus is the leading cause of phytogenic allergic contact dermatitis in India. The Indian Standard Series currently supplied by Systopic Laboratories Ltd and manufactured by Chemotechnique Diagnostics ® contains parthenolide as the only allergen representing plant allergens. AIM: The study was conducted to assess the performance of the Chemotechnique plant series (PL-1000), consisting of 14 allergens, in patients with clinically suspected occupational contact dermatitis to plant allergens. METHODS: Ninety patients were patch tested with the Chemotechnique plant series from 2011 to 2013. Demographic details, clinical diagnosis and patch test results were recorded in the contact dermatitis clinic proforma. RESULTS: Of 90 patients, 24 (26.7%) showed positive reactions to one or more allergens in the plant series. Positive patch tests were elicited most commonly by sesquiterpene lactone mix in 19 (78.6%) patients, followed by parthenolide in 14 (57.1%), Achillea millefolium in 10 (42.9%) and others in decreasing order. CONCLUSION: The plant allergen series prepared by Chemotechnique Diagnostics is possibly not optimal for diagnosing suspected allergic contact dermatitis to plants in north Indians. Sesquiterpene lactone mix should replace parthenolide as the plant allergen in the Indian Standard Series until relevant native plant extracts are commercially available for patch testing.


Assuntos
Alérgenos/imunologia , Asteraceae/imunologia , Dermatite Alérgica de Contato/etiologia , Dermatite Ocupacional/etiologia , Plantas/imunologia , Achillea/imunologia , Adulto , Alérgenos/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Ocupacional/diagnóstico , Feminino , Humanos , Índia , Lactonas/imunologia , Masculino , Pessoa de Meia-Idade , Testes do Emplastro , Plantas/efeitos adversos , Sesquiterpenos/imunologia , Tanacetum/imunologia
20.
Artigo em Inglês | MEDLINE | ID: mdl-25035351

RESUMO

BACKGROUND: A good patch test system should have good adhesion and contact, and minimal leakage; Finn and IQ patch test system have these properties but are expensive. AIMS: To develop a new cost-effective occlusive patch test system that had good contact with the skin and was non-irritant. METHODS: The system (designated Chamber X) was fabricated using a semi-permeable tape and a flexible virgin plastic chamber. Chamber X was developed by (i) selecting adhesive tape based on its non irritancy and adhesive potential (ii) testing plastic chamber material for its skin irritancy (iii) testing the assembled system against Finn, IQ and locally available chambers for irritancy, contact, leakage and occlusivity. RESULTS: Chamber X showed better occlusion than IQ, Finn and locally available chambers and was comparable to, (P > 0.05) IQ and Finn in terms of irritancy, contact and leakage. CONCLUSIONS: The results demonstrate that the Chamber X offers a cost effective patch test system comparable to IQ and Finn chambers in terms of safety, adhesion, leakage and occlusivity.


Assuntos
Desenho de Equipamento/normas , Desenho de Equipamento/tendências , Irritantes/metabolismo , Testes do Emplastro/normas , Testes do Emplastro/tendências , Pele/metabolismo , Alérgenos/administração & dosagem , Alérgenos/metabolismo , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/metabolismo , Humanos , Irritantes/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA