Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros


Bases de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Cardiovasc J Afr ; 23(5): 274-80, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22447186

RESUMO

BACKGROUND: We report the first single-centre experience in Africa with the Sensei X robotic navigation system in an unselected subset of patients with atrial fibrillation (AF). METHODS: Data were recorded prospectively of all consecutive patients who underwent robotically assisted catheter ablation therapy using the Sensei X robotic navigation system at the Christiaan Barnard Memorial Hospital, Cape Town, South Africa, from July 2009 to July 2010. Outcomes were defined at one and nine months. RESULTS: A total of 95 patients were included: 63% had only AF and 37% had AF plus atrial flutter. AF was of the persistent type in 81% of patients. The mean procedure, fluoroscopy and ablation times were 220.6 ± 89.6 min, 31.0 ± 20.4 min, and 61.3 ± 28.1 min, respectively. Both fluoroscopy and procedure times were significantly longer for the first 19 patients compared with the remaining 76 patients (43.5 ± 22.7 vs 27.8 ± 18.5 min and 274.7 ± 90.2 vs 207.1 ± 84.7 min, respectively, p = 0.002). The procedural endpoint of the study was successfully achieved in all patients. After one attempt, 27% were discharged from hospital off anti-arrhythmic drugs (AADs). At a median of nine months' follow up, 74% were AF-free off AADs, and 11% were AF-free on AADs, yielding a total freedom from AF of 84% without any redo procedures. Freedom from relapse after 1.12 procedures was 88%. CONCLUSION: The Sensei X robotic navigation system offers a safe and effective approach for the treatment of AF. There was a learning curve with regard to fluoroscopy and procedure time, after which point reduction in radiation exposure and operator strain, as well as improvement in procedure throughputs were even more pronounced.


Assuntos
Fibrilação Atrial/cirurgia , Robótica , Cirurgia Assistida por Computador/métodos , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Robótica/instrumentação , Robótica/métodos , África do Sul , Cirurgia Assistida por Computador/instrumentação , Resultado do Tratamento
2.
J Am Coll Cardiol ; 51(25): 2407-11, 2008 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-18565397

RESUMO

OBJECTIVES: We present the initial clinical human experience with the use of a robotic remote navigation system (Hansen Medical, Mountain View, California), to perform left and right atrial mapping and radiofrequency ablation of atrial fibrillation (AF) and atrial flutter (AFL). BACKGROUND: Catheter ablation is an established curative modality for various arrhythmias. A robotic steerable sheath system (SSS) (Hansen Medical) allows better catheter stability and greater degrees of freedom of catheter movement. METHODS: A total of 40 patients (mean age 57 years) with antiarrhythmic drug (AAD)-refractory AF (23 had also concomitant documented typical AFL) were studied. Three-dimensional reconstruction of the corresponding atrial chamber anatomy was performed with the CARTO electroanatomic mapping system (Biosense Webster, Diamond Bar, California or the EnSite NavX system (St. Jude Medical, Minneapolis, Minnesota) in combination with the Artisan catheter (Hansen Medical). In patients undergoing AF ablation, 2 transseptal punctures were performed under intracardiac ultrasound (ICE) guidance, with one of the punctures being performed using SSS. Pulmonary vein antrum isolation was performed with a 3.5-mm thermocool catheter manipulated with the use of the SSS and was verified by circular mapping. Patients were followed clinically for recurrence of arrhythmia with an event transmitter and ambulatory holter monitoring. Clinical recurrence of AF/AFL was defined as AF/AFL episodes >1 min in duration. RESULTS: Pulmonary vein antrum isolation was performed in 40 patients, including 23 with concomitant typical AFL ablation. All pulmonary veins, including the superior vena cava, were successfully isolated. In 23 of 40 patients, cavotricuspid ablation was also performed with bidirectional block obtained. At 1-year follow-up, 34 patients (86%) and 5 patients were free from atrial arrhythmia off AADs and on AADs, respectively. CONCLUSIONS: This preliminary human experience suggests that mapping and ablation of AFL and AF using this novel robotic catheter with remote control system is feasible with similar results to conventional approach.


Assuntos
Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Ablação por Cateter/instrumentação , Robótica/instrumentação , Fibrilação Atrial/terapia , Flutter Atrial/terapia , Ablação por Cateter/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/patologia , Veias Pulmonares/cirurgia , Robótica/métodos , Fatores de Tempo , Veia Cava Superior/patologia , Veia Cava Superior/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA