J Electrocardiol ; 45(2): 95-101, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21714971

RESUMO

BACKGROUND AND PURPOSE: Remote robotic navigation (RRN) technology has been developed to facilitate catheter ablation of symptomatic atrial fibrillation (AF). Here, we assess procedural parameters of AF ablation obtained during initial use of RRN compared with a control group treated with a manual ablation approach. METHODS: Consecutive patients with symptomatic paroxysmal or persistent AF were subjected to radiofrequency catheter ablation with RRN (Sensei X [Hansen Medical, Mountain View, CA]; n = 25; mean age, 60 ± 2.3 years) or using the standard manual technique (n = 61; mean age, 62 ± 1.4 years). A circumferential pulmonary vein isolation approach guided by 3-dimensional electroanatomical mapping was followed. RESULTS: Remote robotic navigation was associated with reduction of overall fluoroscopy time by 26%. In a case-control subgroup analysis comparing 25 patients with similar clinical characteristics from each group, mean fluoroscopy time was reduced by 22%. Acute isolation of pulmonary veins was achieved in 97% (RRN) and 96% (conventional ablation), respectively. Ablation times and frequency of adverse events were not significantly different among study groups. CONCLUSIONS: The early use of RRN resulted in a significant reduction of overall fluoroscopy time and was equally effective and safe compared with manual catheter ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Robótica/métodos , Fibrilação Atrial/fisiopatologia , Estudos de Casos e Controles , Distribuição de Qui-Quadrado , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas/métodos , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Veias Pulmonares/cirurgia , Fatores de Tempo , Resultado do Tratamento
2.
J Cardiovasc Electrophysiol ; 21(10): 1079-84, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20455974

RESUMO

AIMS: A robotic navigation system (RNS, Hansen™) has been developed as an alternative method of performing ablation for atrial fibrillation (AF). Despite the growing application of RNS-guided pulmonary vein isolation (PVI), its consequences and mechanisms of subsequent AF recurrences are unknown. We investigated the acute procedural success and persistence of PVI over time after robotic PVI and its relation to clinical outcome. METHODS AND RESULTS: Sixty-four patients (60.7 ± 9.8 years, 53 male) with paroxysmal AF underwent robotic circumferential PVI with 3-dimensional left atrial reconstruction (NavX™). A voluntary repeat invasive electrophysiological study was performed 3 months after ablation irrespective of clinical course. Robotic PVI was successful in all patients without complication (fluoroscopy time: 23.5 [12-34], procedure time: 180 [150-225] minutes). Fluoroscopy time demonstrated a gradual decline but was significantly reduced after the 30th patient following the introduction of additional navigation software (34 [29-45] vs 12 [9-17] minutes; P < 0.001). A repeat study at 3 months was performed in 63% of patients and revealed electrical conduction recovery in 43% of all PVs. Restudied patients without AF recurrence (n = 28) showed a significantly lower number of recovered PVs (1 (0-2) vs 2 (2-3); P = 0.006) and a longer LA-PV conduction delay than patients with AF recurrences (n = 12). Persistent block of all PVs was associated with freedom from AF in all patients. At 3 months, 67% of patients were free of AF, while reablation of recovered PVs led to an overall freedom from AF in 81% of patients after 1 year. CONCLUSION: Robotic PVI for PAF is safe, effective, and requires limited fluoroscopy while yielding comparable success rates to conventional ablation approaches with PV reconduction as a common phenomenon associated with AF recurrences.


Assuntos
Fibrilação Atrial/cirurgia , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Robótica/métodos , Cirurgia Assistida por Computador/métodos , Telemedicina/métodos , Fibrilação Atrial/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Resultado do Tratamento
3.
Europace ; 12(5): 655-61, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20233761

RESUMO

AIMS: Oesophageal lesions (EL), a potential complication after pulmonary vein isolation (PVI), have been described recently. A new remote robotic navigation system (RNS; Hansen Medical) provides enhanced catheter stability along with more effective lesion placement. The aim of this prospective study was to evaluate temperature monitoring and incidence of EL when using RNS with an irrigated tip radiofrequency catheter for PVI. METHODS AND RESULTS: Circumferential PVI using RNS was performed in 73 patients (pts) with paroxysmal (n = 46, 63%) and persistent atrial fibrillation. An oesophageal temperature probe was placed in 58 (79.5%) pts and was integrated in the 3D-map (NavX). Power was limited to 25 W at the posterior wall, and in the case of an increase in temperature power was limited to 20 W. Endoscopy was performed in 42 pts within 24 h after PVI. In 44 of 58 (75.9%) pts, a significant rise in temperature (>39 degrees C) was observed. In 6 of 42 (14.3%) pts, an EL was found during endoscopy. In patients with EL, the body mass index (BMI) was significantly lower than in pts without EL (24.1 +/- 2.0 vs. 29.0 +/- 5.8, P = 0.047). The BMI of all patients with EL was <26, whereas all patients without EL had a BMI above 26. The EL showed brisk healing after re-endoscopy within 2 weeks in all pts. CONCLUSION: In patients undergoing PVI using the RNS, the incidence of EL is 14.3% when using power settings comparable to settings used in manual ablation. Patients with lower BMI (<26) are at higher risk for EL.


Assuntos
Fibrilação Atrial/cirurgia , Temperatura Corporal/fisiologia , Ablação por Cateter/efeitos adversos , Esôfago/lesões , Esôfago/fisiologia , Veias Pulmonares/cirurgia , Robótica/métodos , Idoso , Índice de Massa Corporal , Ablação por Cateter/métodos , Endoscopia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Estudos Prospectivos , Análise de Regressão , Estudos Retrospectivos , Fatores de Risco
4.
J Am Coll Cardiol ; 51(25): 2407-11, 2008 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-18565397

RESUMO

OBJECTIVES: We present the initial clinical human experience with the use of a robotic remote navigation system (Hansen Medical, Mountain View, California), to perform left and right atrial mapping and radiofrequency ablation of atrial fibrillation (AF) and atrial flutter (AFL). BACKGROUND: Catheter ablation is an established curative modality for various arrhythmias. A robotic steerable sheath system (SSS) (Hansen Medical) allows better catheter stability and greater degrees of freedom of catheter movement. METHODS: A total of 40 patients (mean age 57 years) with antiarrhythmic drug (AAD)-refractory AF (23 had also concomitant documented typical AFL) were studied. Three-dimensional reconstruction of the corresponding atrial chamber anatomy was performed with the CARTO electroanatomic mapping system (Biosense Webster, Diamond Bar, California or the EnSite NavX system (St. Jude Medical, Minneapolis, Minnesota) in combination with the Artisan catheter (Hansen Medical). In patients undergoing AF ablation, 2 transseptal punctures were performed under intracardiac ultrasound (ICE) guidance, with one of the punctures being performed using SSS. Pulmonary vein antrum isolation was performed with a 3.5-mm thermocool catheter manipulated with the use of the SSS and was verified by circular mapping. Patients were followed clinically for recurrence of arrhythmia with an event transmitter and ambulatory holter monitoring. Clinical recurrence of AF/AFL was defined as AF/AFL episodes >1 min in duration. RESULTS: Pulmonary vein antrum isolation was performed in 40 patients, including 23 with concomitant typical AFL ablation. All pulmonary veins, including the superior vena cava, were successfully isolated. In 23 of 40 patients, cavotricuspid ablation was also performed with bidirectional block obtained. At 1-year follow-up, 34 patients (86%) and 5 patients were free from atrial arrhythmia off AADs and on AADs, respectively. CONCLUSIONS: This preliminary human experience suggests that mapping and ablation of AFL and AF using this novel robotic catheter with remote control system is feasible with similar results to conventional approach.


Assuntos
Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Ablação por Cateter/instrumentação , Robótica/instrumentação , Fibrilação Atrial/terapia , Flutter Atrial/terapia , Ablação por Cateter/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/patologia , Veias Pulmonares/cirurgia , Robótica/métodos , Fatores de Tempo , Veia Cava Superior/patologia , Veia Cava Superior/cirurgia