Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Thorax ; 76(2): 178-181, 2021 02.
Article in English | MEDLINE | ID: mdl-33139449

ABSTRACT

To investigate whether hyperpolarised xenon-129 MRI (HXeMRI) enables regional and physiological resolution of diffusing capacity limitations in chronic obstructive pulmonary disease (COPD), we evaluated 34 COPD subjects and 11 healthy volunteers. We report significant correlations between airflow abnormality quantified by HXeMRI and per cent predicted forced expiratory volume in 1 s; HXeMRI gas transfer capacity to red blood cells and carbon monoxide diffusion capacity (%DLCO); and HXeMRI gas transfer capacity to interstitium and per cent emphysema quantified by multidetector chest CT. We further demonstrate the capability of HXeMRI to distinguish varying pathology underlying COPD in subjects with low %DLCO and minimal emphysema.


Subject(s)
Magnetic Resonance Imaging/methods , Pulmonary Disease, Chronic Obstructive/diagnostic imaging , Pulmonary Disease, Chronic Obstructive/physiopathology , Pulmonary Gas Exchange , Aged , Case-Control Studies , Female , Humans , Male , Middle Aged , Tomography, X-Ray Computed , Xenon Isotopes
2.
Respir Res ; 20(1): 216, 2019 Oct 11.
Article in English | MEDLINE | ID: mdl-31604436

ABSTRACT

BACKGROUND: Idiopathic pulmonary fibrosis (IPF) is a fatal lung disease involving progressive degeneration of lung capacity. Current diagnosis of IPF heavily relies on visual evaluation of fibrotic features in high-resolution computed tomography (HRCT) images of the lungs. Although the characteristics of this disease have been studied at the molecular and cellular levels, little is known about the mechanical characteristics of IPF lungs inferred from HRCT images. To this end, we performed a pilot study to investigate the radiographic and volumetric characteristics of lungs in subjects with IPF. METHODS: We collected HRCT images of healthy (N = 13) and IPF (N = 9) lungs acquired at breath-holds after full inspiration (expanded state) and full expiration (contracted state). We performed statistical analyses on Hounsfield unit (HU) histograms, lobar volumes (V: lobe volume normalized by the lung volume), and lobar flows (Q: the difference in lobe volume divided by the difference in lung volume between the expanded and contracted states). RESULTS: Parameters characterizing the HU histograms (i.e., mean, median, skewness, and kurtosis) significantly differed between healthy and IPF subjects, for all lobes in both expanded and contracted states. The distribution of V across lobes differed significantly between the groups in both states. The distribution of Q also differed significantly between the groups: Q values of the lower lobes for the IPF group were 33% (right) and 22% (left) smaller than those for the healthy group, consistent with the observation that radiographic scores were highest in the lower lung section in IPF. Notably, the root-mean-squared difference (RMSD) of Q, a measure of distance from the mean value of the healthy group, clearly distinguished the IPF subjects (RMSD of Q > 1.59) from the healthy group (RMSD of Q < 0.67). CONCLUSION: This study shows that lung volume and flow distribution change heterogeneously across the lung lobes of IPF subjects, with reduced capacity in the lower lobes. These volumetric changes may improve our understanding of the pathophysiology in IPF lungs.


Subject(s)
Idiopathic Pulmonary Fibrosis/diagnostic imaging , Image Processing, Computer-Assisted/methods , Lung/diagnostic imaging , Tomography, X-Ray Computed/methods , Aged , Female , Humans , Idiopathic Pulmonary Fibrosis/physiopathology , Lung Volume Measurements , Male , Middle Aged , Pilot Projects , Respiratory Function Tests , Respiratory Mechanics
3.
Biomedicines ; 11(6)2023 May 25.
Article in English | MEDLINE | ID: mdl-37371626

ABSTRACT

PURPOSE: The existing tools to quantify lung function in interstitial lung diseases have significant limitations. Lung MRI imaging using inhaled hyperpolarized xenon-129 gas (129Xe) as a contrast agent is a new technology for measuring regional lung physiology. We sought to assess the utility of the 129Xe MRI in detecting impaired lung physiology in usual interstitial pneumonia (UIP). MATERIALS AND METHODS: After institutional review board approval and informed consent and in compliance with HIPAA regulations, we performed chest CT, pulmonary function tests (PFTs), and 129Xe MRI in 10 UIP subjects and 10 healthy controls. RESULTS: The 129Xe MRI detected highly heterogeneous abnormalities within individual UIP subjects as compared to controls. Subjects with UIP had markedly impaired ventilation (ventilation defect fraction: UIP: 30 ± 9%; healthy: 21 ± 9%; p = 0.026), a greater amount of 129Xe dissolved in the lung interstitium (tissue-to-gas ratio: UIP: 1.45 ± 0.35%; healthy: 1.10 ± 0.17%; p = 0.014), and impaired 129Xe diffusion into the blood (RBC-to-tissue ratio: UIP: 0.20 ± 0.06; healthy: 0.28 ± 0.05; p = 0.004). Most MRI variables had no correlation with the CT and PFT measurements. The elevated level of 129Xe dissolved in the lung interstitium, in particular, was detectable even in subjects with normal or mildly impaired PFTs, suggesting that this measurement may represent a new method for detecting early fibrosis. CONCLUSION: The hyperpolarized 129Xe MRI was highly sensitive to regional functional changes in subjects with UIP and may represent a new tool for understanding the pathophysiology, monitoring the progression, and assessing the effectiveness of treatment in UIP.

4.
Acad Radiol ; 26(3): 326-334, 2019 03.
Article in English | MEDLINE | ID: mdl-30087065

ABSTRACT

RATIONALE AND OBJECTIVES: Chronic obstructive pulmonary disease (COPD) is highly heterogeneous and not well understood. Hyperpolarized xenon-129 (Xe129) magnetic resonance imaging (MRI) provides a unique way to assess important lung functions such as gas uptake. In this pilot study, we exploited multiple imaging modalities, including computed tomography (CT), gadolinium-enhanced perfusion MRI, and Xe129 MRI, to perform a detailed investigation of changes in lung morphology and functions in COPD. Utility and strengths of Xe129 MRI in assessing COPD were also evaluated against the other imaging modalities. MATERIALS AND METHODS: Four COPD patients and four age-matched normal subjects participated in this study. Lung tissue density measured by CT, perfusion measures from gadolinium-enhanced MRI, and ventilation and gas uptake measures from Xe129 MRI were calculated for individual lung lobes to assess regional changes in lung morphology and function, and to investigate correlations among the different imaging modalities. RESULTS: No significant differences were found for all measures among the five lobes in either the COPD or age-matched normal group. Strong correlations (R > 0.5 or < -0.5, p < 0.001) were found between ventilation and perfusion measures. Also gas uptake by blood as measured by Xe129 MRI showed strong correlations with CT tissue density and ventilation measures (R > 0.5 or < -0.5, p < 0.001) and moderate to strong correlations with perfusion measures (R > 0.4 or < -0.5, p < 0.01). Four distinctive patterns of functional abnormalities were found in patients with COPD. CONCLUSION: Xe129 MRI has high potential to uniquely identify multiple changes in lung physiology in COPD using a single breath-hold acquisition.


Subject(s)
Magnetic Resonance Imaging/methods , Pulmonary Disease, Chronic Obstructive/diagnostic imaging , Pulmonary Disease, Chronic Obstructive/physiopathology , Tomography, X-Ray Computed , Ventilation-Perfusion Scan , Aged , Case-Control Studies , Female , Gadolinium , Humans , Male , Middle Aged , Pilot Projects , Pulmonary Ventilation , Xenon Isotopes
SELECTION OF CITATIONS
SEARCH DETAIL