Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 36
Filter
1.
Magn Reson Med ; 78(2): 721-729, 2017 08.
Article in English | MEDLINE | ID: mdl-27689918

ABSTRACT

PURPOSE: The purpose of this work was to investigate disease progression and treatment response in a murine model of chronic obstructive pulmonary disease (COPD) using a preclinical hyperpolarized 129 Xe (HPXe) magnetic resonance imaging (MRI) strategy. METHODS: COPD phenotypes were induced in 32 mice by 10 weeks of exposure to cigarette smoke (CS) and lipopolysaccharide (LPS). Efficacy of ethyl pyruvate (EP), an anti-inflammatory drug, was investigated by administering EP to 16 of the 32 mice after 6 weeks of CS and LPS exposure. HPXe MRI was performed to monitor changes in pulmonary function during disease progression and pharmacological therapy. RESULTS: HPXe metrics of fractional ventilation and gas-exchange function were significantly reduced after 6 weeks of CS and LPS exposure compared to sham-instilled mice administered with saline (P < 0.05). After this observation, EP administration was started in 16 of the 32 mice and continued for 4 weeks. EP was found to improve HPXe MRI metrics to a similar level as in sham-instilled mice (P < 0.01). Histological analysis showed significant alveolar tissue destruction in the COPD group, but relatively normal alveolar structure in the EP and sham-instilled groups. CONCLUSION: This study demonstrates the potential efficacy of EP for COPD therapy, as assessed by a noninvasive, translatable 129 Xe MRI procedure. Magn Reson Med 78:721-729, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Subject(s)
Anti-Inflammatory Agents/therapeutic use , Magnetic Resonance Imaging/methods , Pulmonary Disease, Chronic Obstructive , Pyruvates/therapeutic use , Xenon Isotopes/chemistry , Animals , Image Processing, Computer-Assisted/methods , Male , Mice , Pulmonary Disease, Chronic Obstructive/diagnostic imaging , Pulmonary Disease, Chronic Obstructive/drug therapy
2.
NMR Biomed ; 29(10): 1414-9, 2016 10.
Article in English | MEDLINE | ID: mdl-27526627

ABSTRACT

The use of a quenching gas, isobutene, with a low vapor pressure was investigated to enhance the utility of hyperpolarized (129) Xe (HP Xe) MRI. Xenon mixed with isobutene was hyperpolarized using a home-built apparatus for continuously producing HP Xe. The isobutene was then readily liquefied and separated almost totally by continuous condensation at about 173 K, because the vapor pressure of isobutene (0.247 kPa) is much lower than that of Xe (157 kPa). Finally, the neat Xe gas was continuously delivered to mice by spontaneous inhalation. The HP Xe MRI was enhanced twofold in polarization level and threefold in signal intensity when isobutene was adopted as the quenching gas instead of N2 . The usefulness of the HP Xe MRI was verified by application to pulmonary functional imaging of spontaneously breathing mice, where the parameters of fractional ventilation (ra ) and gas exchange (fD ) were evaluated, aiming at future extension to preclinical studies. This is the first application of isobutene as a quenching gas for HP Xe MRI.


Subject(s)
Alkenes/pharmacokinetics , Image Enhancement/methods , Lung/physiology , Magnetic Resonance Imaging/methods , Pulmonary Gas Exchange/physiology , Xenon Isotopes/pharmacokinetics , Administration, Inhalation , Alkenes/administration & dosage , Animals , Contrast Media , Gases , Image Interpretation, Computer-Assisted/methods , Lung/diagnostic imaging , Male , Mice , Mice, Inbred Strains , Radiopharmaceuticals/administration & dosage , Radiopharmaceuticals/pharmacology , Reproducibility of Results , Sensitivity and Specificity , Xenon Isotopes/administration & dosage
3.
NMR Biomed ; 28(1): 24-9, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25312654

ABSTRACT

The feasibility of ventilation imaging with hyperpolarized (HP) (129) Xe MRI has been investigated for quantitative and regional assessment of ventilation in spontaneously breathing mice. The multiple breath ventilation imaging technique was modified to the protocol of spontaneous inhalation of HP (129) Xe delivered continuously from a (129) Xe polarizer. A series of (129) Xe ventilation images was obtained by varying the number of breaths before the (129) Xe lung imaging. The fractional ventilation, r, was successfully evaluated for spontaneously breathing mice. An attempt was made to detect ventilation dysfunction in the emphysematous mouse lung induced by intratracheal administration of porcine pancreatic elastase (PPE). As a result, the distribution of fractional ventilation could be visualized by the r map. Significant dysfunction of ventilation was quantitatively identified in the PPE-treated group. The whole-lung r value of 0.34 ± 0.01 for control mice (N = 4) was significantly reduced, to 0.25 ± 0.07, in PPE-treated mice (N = 4) (p = 0.038). This study is the first application of multiple breath ventilation imaging to spontaneously breathing mice, and shows that this methodology is sensitive to differences in the pulmonary ventilation. This methodology is expected to improve simplicity as well as noninvasiveness when assessing regional ventilation in small rodents.


Subject(s)
Magnetic Resonance Imaging/methods , Pulmonary Ventilation/physiology , Respiration , Animals , Lung/physiology , Male , Mice, Inbred C57BL , Signal Processing, Computer-Assisted , Xenon Isotopes
4.
Magn Reson Med Sci ; 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38839300

ABSTRACT

PURPOSE: Chronic obstructive pulmonary disease (COPD) is a complex multisystem disease associated with comorbidities outside the lungs. The aim of this study was to measure changes in metrics of pulmonary gas exchange function and brain tissue metabolism in a mouse model of COPD using hyperpolarized 129Xe (HP 129Xe) MRI/MR spectroscopy (MRS) and investigate the relationship between the metrics of lung and brain. METHODS: COPD phenotypes were induced in 15 mice by 6-week administration of cigarette smoke extract (CSE) and lipopolysaccharide (LPS). A separate negative control (NC) group was formed of 6 mice administered with saline for 6 weeks. After these 6-week administrations, the pulmonary gas exchange function parameter fD (%) and the rate constant, α (s-1), which are composed of the cerebral blood flow Fi and the longitudinal relaxation rate 1/T1i in brain tissue, were evaluated by HP 129Xe MRI/MRS. RESULTS: The fD of CSE-LPS mice was significantly lower than that of NC mice, which was in parallel with an increase in bronchial wall thickness. The α in the CSE-LPS mice decreased with the decrease of fD in contrast to the trend in the NC mice. To further elucidate the opposed trend, the contribution of T1i was separately determined by measuring Fi. The T1i in the CSE-LPS mice was found to correlate negatively with fD as opposed to the positive trend in the NC mice. The opposite trend in T1i between CSE-LPS and NC mice suggests hypoxia in the brain, which is induced by the impaired oxygen uptake as indicated by the reduced fD. CONCLUSION: This study demonstrates the feasibility of using HP 129Xe MRI/MRS to study pathological mechanisms of brain dysfunction in comorbidities with COPD.

5.
Am J Respir Cell Mol Biol ; 49(4): 592-600, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23668642

ABSTRACT

Animal disease models are pivotal in investigating the pathogenesis of emphysema and developing novel drugs, but the modalities to evaluate murine emphysema models have been of limited validity and sensitivity. In this study, we evaluated hyperpolarized (129)Xe magnetic resonance imaging (MRI) and micro-computed tomography (micro-CT) compared with traditional methods, such as plethysmography and histology. Elastase-treated mice and adiponectin knockout mice were used as murine emphysema models to evaluate these modalities. Three weeks after elastase administration, significant and heterogeneous emphysema was evaluated according to the mean linear intercept and plethysmography parameters. Notably, the distribution of low-density areas, as examined by micro-CT, correlated with the mean linear intercept and plethysmography parameters in whole lungs. These correlations were also observed in regional areas. Furthermore, we introduced hyperpolarized (129)Xe MRI, which can evaluate gas exchange between the alveoli and blood during spontaneous breathing. Parameters of gas exchange (fD) and alveolar size (Vs/Va) were significantly decreased in elastase-treated mice, and moderately correlated with the plethysmography parameters. Of importance, we could detect a decrease of the fD value in low-density areas with micro-CT, suggesting that gas exchange decreased in emphysematous lesions. Likewise, these parameters (fD and Vs/Va) were also decreased in adiponectin knockout mice, which exhibit emphysema with a homogeneous distribution. We demonstrated the feasibility of (129)Xe MRI and micro-CT in combination with traditional modalities. These noninvasive modalities provide complementary data that can be used for repeated estimations of regional gas exchange and lung morphology.


Subject(s)
Magnetic Resonance Imaging/methods , Pulmonary Alveoli/diagnostic imaging , Pulmonary Alveoli/pathology , Pulmonary Emphysema/diagnostic imaging , Pulmonary Emphysema/pathology , Tomography, X-Ray Computed/methods , Xenon Isotopes/analysis , Animals , Disease Models, Animal , Male , Mice , Mice, Inbred C57BL
6.
Magn Reson Med ; 70(1): 207-15, 2013 Jul.
Article in English | MEDLINE | ID: mdl-22887860

ABSTRACT

MRI of hyperpolarized (129)Xe dissolved in pulmonary tissues, and blood has the potential to offer a new tool for regional evaluation of pulmonary gas exchange and perfusion; however, the extremely short T2* and low magnetization density make it difficult to acquire the image. In this study, an ultrashort echo-time sequence was introduced, and its feasibility to quantitatively assess emphysema-like pulmonary tissue destruction by a combination of dissolved- and gas-phase (129)Xe lung MRI was investigated. The ultrashort echo-time has made it possible to acquire dissolved (129)Xe images with reasonably high spatial resolution of 0.625 × 0.625 mm(2) and to obtain T2* of 0.67 ± 0.30 ms in a spontaneously breathing mouse at 9.4 T. The regional dynamic alveolar gas uptake as well as subsequent transport by pulmonary blood flow was also visualized. The ratio of (129)Xe magnetization that diffused into the septa relative to the gas-phase magnetization F was regionally evaluated. The mean F value of elastase-treated mice was 2.28 ± 0.46%, which was significantly reduced from that of control mice 3.41 ± 0.48% (P = 0.0052). This reflects the reduced uptake efficiency due to alveolar tissue destruction and is correlated with the histologically derived alveolar surface-to-volume ratio.


Subject(s)
Emphysema/metabolism , Emphysema/pathology , Magnetic Resonance Imaging/methods , Xenon Isotopes/pharmacokinetics , Administration, Inhalation , Animals , Contrast Media/administration & dosage , Male , Metabolic Clearance Rate , Mice , Mice, Inbred Strains , Reproducibility of Results , Sensitivity and Specificity , Tissue Distribution , Xenon Isotopes/administration & dosage
7.
NMR Biomed ; 25(2): 210-7, 2012 Feb.
Article in English | MEDLINE | ID: mdl-21755553

ABSTRACT

A fast method has been established for the precise measurement and quantification of the dynamics of hyperpolarized (HP) xenon-129 ((129)Xe) in the mouse brain. The key technique is based on repeatedly applying radio frequency (RF) pulses and measuring the decrease of HP (129)Xe magnetization after the brain Xe concentration has reached a steady state due to continuous HP (129)Xe ventilation. The signal decrease of the (129)Xe nuclear magnetic resonance (NMR) signal was well described by a simple theoretical model. The technique made it possible to rapidly evaluate the rate constant α, which is composed of cerebral blood flow (CBF), the partition coefficient of Xe between the tissue and blood (λ(i)), and the longitudinal relaxation time (T(1i)) of HP (129)Xe in the brain tissue, without any effect of depolarization by RF pulses and the dynamics in the lung. The technique enabled the precise determination of α as 0.103 ± 0.018 s(-1) (± SD, n = 5) on healthy mice. To investigate the potential of this method for detecting physiological changes in the brain of a kainic acid (KA) -induced mouse model of epilepsy, an attempt was made to follow the time course of α after KA injection. It was found that the α value changes characteristically with time, reflecting the change in the physiological state of the brain induced by KA injection. By measuring CBF using (1)H MRI and (129)Xe dynamics simultaneously and comparing these results, it was suggested that the reduction of T(1i), in addition to the increase of CBF due to KA-induced epilepsy, are possible causes of the change in (129)Xe dynamics. Thus, the present method would be useful to detect a pathophysiological state in the brain and provide a novel tool for future brain study.


Subject(s)
Brain/metabolism , Magnetic Resonance Spectroscopy/methods , Animals , Brain/blood supply , Brain/drug effects , Injections , Kainic Acid/administration & dosage , Kainic Acid/pharmacology , Kinetics , Male , Mice , Organ Specificity/drug effects , Time Factors , Xenon Isotopes
8.
Magn Reson Imaging ; 92: 88-95, 2022 10.
Article in English | MEDLINE | ID: mdl-35654279

ABSTRACT

BACKGROUND: Lung ventilation function in small animals can be assessed by using hyperpolarized gas MRI. For these experiments a free breathing protocol is generally preferred to mechanical ventilation as mechanical ventilation can often lead to ventilation lung injury, while the need to maintain a gas reservoir may lead to a partial reduction of the polarization. PURPOSE: To evaluate regional lung ventilation of mice by a simple but fast method under free breathing and give evidence for effectiveness with an elastase instilled emphysematous mice. ANIMAL MODEL: Emphysematous mice. MATERIALS AND METHODS: A Look-Locker based saturation recovery sequence was developed for continuous flow hyperpolarized (CF-HP) 129Xe gas experiments, and the apparent gas-exchange rate, k', was measured by the analysis of the saturation recovery curve. RESULTS: In mice with elastase-induced mild emphysema, reductions of 15-30% in k' values were observed as the results of lesion-induced changes in the lung. DATA CONCLUSION: The proposed method was applied to an emphysematous model mice and ventilation dysfunctions have been approved as a definite decrease in k' values, supporting the usefulness for a non-invasive assessment of the lung functions in preclinical study by the CF-HP 129Xe experiments.


Subject(s)
Emphysema , Xenon Isotopes , Animals , Emphysema/diagnostic imaging , Lung/diagnostic imaging , Magnetic Resonance Imaging/methods , Mice , Pancreatic Elastase , Respiration, Artificial
9.
Cancers (Basel) ; 14(24)2022 Dec 09.
Article in English | MEDLINE | ID: mdl-36551556

ABSTRACT

Hyperpolarized 129Xe (HP 129Xe) MRI enables functional imaging of various lung diseases but has been scarcely applied to lung cancer imaging. The aim of this study is to investigate the feasibility of targeted imaging of lung cancer with HP 129Xe MRI using surface-modified iron oxide nanoparticles (IONPs) as molecular targeting contrast agents. A mouse model of lung cancer (LC) was induced in nine mice by intra-peritoneal injection of urethane. Three months after the urethane administration, the mice underwent lung imaging with HP 129Xe MRI at baseline (0 h). Subsequently, the LC group was divided into two sub-groups: mice administered with polyethylene glycol-coated IONPs (PEG-IONPs, n = 4) and folate-conjugated dextran-coated IONPs (FA@Dex-IONPs, n = 5). The mice were imaged at 3, 6, and 24 h after the intravenous injection of IONPs. FA@Dex-IONPs mice showed a 25% reduction in average signal intensity at cancer sites at 3 h post injection, and a 24% reduction at 24 h post injection. On the other hand, in PEG-IONPs mice, while a signal reduction of approximately 28% was observed at cancer sites at 3 to 6 h post injection, the signal intensity was unchanged from that of the baseline at 24 h. Proton MRI of LC mice (n = 3) was able to detect cancer five months after urethane administration, i.e., later than HP 129Xe MRI (3 months). Furthermore, a significant decrease in averaged 1H T2 values at cancer sites was observed at only 6 h post injection of FA@Dex-IONPs (p < 0.05). As such, the targeted delivery of IONPs to cancer tissue was successfully imaged with HP 129Xe MRI, and their surface modification with folate likely has a high affinity with LC, which causes overexpression of folate receptors.

10.
NMR Biomed ; 24(10): 1343-52, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21538635

ABSTRACT

In the present study, a balanced steady-state free precession pulse sequence combined with compressed sensing was applied to hyperpolarized (129) Xe lung imaging in spontaneously breathing mice. With the aid of fast imaging techniques, the temporal resolution was markedly improved in the resulting images. Using these protocols and respiratory gating, (129) Xe lung images in end-inspiratory and end-expiratory phases were obtained successfully. The application of these techniques for pulmonary functional imaging made it possible to simultaneously evaluate regional ventilation and gas exchange in the same animal. A comparative study between healthy and elastase-induced mouse models of emphysema showed abnormal ventilation as well as gas exchange in elastase-treated mice.


Subject(s)
Lung/physiopathology , Magnetic Resonance Imaging/methods , Respiration , Xenon/metabolism , Animals , Image Processing, Computer-Assisted , Lung/pathology , Mice , Staining and Labeling , Time Factors , Xenon Isotopes
11.
Anal Sci ; 37(12): 1803-1810, 2021.
Article in English | MEDLINE | ID: mdl-34897179

ABSTRACT

129Xe NMR spectroscopy of nanomaterials, such as zeolites, can provide valuable information on the nanostructure and physicochemical properties of adsorption. In the present study the pressure and temperature dependences of the 129Xe NMR chemical shift and the signal intensity were investigated in detail with a zeolite ZSM-5. The pressure dependence of the signal intensity at constant temperature was analyzed based on the Langmuir and Dubinin-Radushkevich (D-R) models, from which the thermodynamic parameters and energetic profiles of adsorption were obtained together with information concerning the nanospace size. From this isotherm analysis the coverage, θ, was calculated and used for isotherm analysis of the chemical shift. The θ dependence of the chemical shift was successfully fitted by an exponential function, and the results were discussed in relation to the chemical shift at zero coverage, that at full coverage and the curvature of the exponential function. The chemical shift data reported with the zeolites NaA and KA, where separated signals were observed for the different number of encapsulated Xe atoms in the α cage, were analyzed and discussed collectively.


Subject(s)
Zeolites , Adsorption , Magnetic Resonance Spectroscopy , Temperature , Thermodynamics
12.
Contrast Media Mol Imaging ; 2021: 9918702, 2021.
Article in English | MEDLINE | ID: mdl-34257627

ABSTRACT

This study aimed to assess the suitability of hyperpolarized 129Xe (HPXe) MRI for noninvasive longitudinal evaluation of pulmonary function in preclinical lung cancer models. A mouse model of lung cancer (LC) was induced in 5 mice by intraperitoneal injection of urethane, while a negative-control (NC) mice (N = 5) was prepared by injection of saline solution. Longitudinal HPXe MRI was performed over a 5-month period to monitor lung ventilation and gas exchange. The treatment efficacy of ethyl pyruvate (EP), an anti-inflammatory drug, to the mouse LC model was monitored using HPXe MRI by commencing administration of EP pre (early-phase) and 1-month post (late-phase) injection of urethane (N = 5 mice for each group). Gas-exchange function in LC mice was significantly reduced at 1-month after urethane injection compared with NC mice administered with saline (P < 0.01). Thereafter, it remained consistently lower than that of the NC group for the full 5-month measurement period. In contrast, the ventilation function of the LC model mice was not significantly different to that of the NC mice. Histological analysis revealed alveolar epithelial hyperplasia in LC mice alveoli at 1 month after urethane injection, and adenoma was confirmed 3 months after the injection. The early- and late-phase EP interventions were found to improve HPXe MRI metrics (reduced at 1 month postinjection of urethane) and significantly inhibit tumor growth. These results suggest that HPXe MRI gas-exchange metrics can be used to quantitatively assess changes in the precancerous lesion microenvironment and to evaluate therapeutic efficacy in cancer. Thus, HPXe MRI can be utilized to noninvasively monitor pulmonary pathology during LC progression and can visualize functional changes during therapy.


Subject(s)
Inflammation/drug therapy , Lung Neoplasms/pathology , Magnetic Resonance Imaging/methods , Pyruvates/pharmacology , Urethane/toxicity , Xenon/chemistry , Animals , Carcinogens/toxicity , Inflammation/etiology , Inflammation/pathology , Lung Neoplasms/chemically induced , Lung Neoplasms/complications , Male , Mice
13.
Magn Reson Med ; 64(4): 929-38, 2010 Oct.
Article in English | MEDLINE | ID: mdl-20740664

ABSTRACT

In the present study, a chemical shift saturation recovery method in hyperpolarized (129)Xe MR spectroscopy measurements was applied to two groups of spontaneously breathing mice, an elastase-induced emphysema model and a control group. Parameters detected were those related to lung structures and functions, such as alveolar septal thickness, h, the ratio of the alveolar septal volume relative to gas space volume, V(s)/V(a), and the transit time of blood through the gas exchange region, τ. To investigate the potential of these parameters as biomarkers, an attempt was made to detect physiologic changes in the lungs of elastase-treated mice. Our results showed that V(s)/V(a) was significantly reduced in elastase-treated mice, reflecting emphysema-like destruction of the alveolar wall. Compared with histologic results, this degree of reduction was shown to reflect the severity of wall destruction. On the other hand, significant changes in other parameters, h and τ, were not shown. This study is the first application of hyperpolarized (129)Xe MR spectroscopy to a mouse model of emphysema and shows that the V(s)/V(a) volume ratio is an effective biomarker for emphysema that could become useful in drug research and development through noninvasive detection of pathologic changes in small rodents.


Subject(s)
Disease Models, Animal , Lung/metabolism , Magnetic Resonance Spectroscopy/methods , Pulmonary Emphysema/diagnosis , Pulmonary Emphysema/metabolism , Xenon Isotopes/pharmacokinetics , Animals , Humans , Male , Mice , Mice, Inbred Strains , Radiopharmaceuticals , Reproducibility of Results , Sensitivity and Specificity
14.
Contrast Media Mol Imaging ; 2020: 5425934, 2020.
Article in English | MEDLINE | ID: mdl-32256252

ABSTRACT

Gas vesicle nanoparticles (GVs) are gas-containing protein assemblies expressed in bacteria and archaea. Recently, GVs have gained considerable attention for biotechnological applications as genetically encodable contrast agents for MRI and ultrasonography. However, at present, the practical use of GVs is hampered by a lack of robust methodology for their induction into mammalian cells. Here, we demonstrate the genetic reconstitution of protein nanoparticles with characteristic bicone structures similar to natural GVs in a human breast cancer cell line KPL-4 and genetic control of their size and shape through expression of reduced sets of humanized gas vesicle genes cloned into Tol2 transposon vectors, referencing the natural gas vesicle gene clusters of the cyanobacteria planktothrix rubescens/agardhii. We then report the utility of these nanoparticles as multiplexed, sensitive, and genetically encoded contrast agents for hyperpolarized xenon chemical exchange saturation transfer (HyperCEST) MRI.


Subject(s)
Bacterial Proteins/chemistry , Magnetic Resonance Imaging , Nanoparticles/chemistry , Neoplasms/metabolism , Xenon Isotopes/chemistry , Cell Line, Tumor , Humans , Nanoparticles/ultrastructure
15.
Magn Reson Med Sci ; 8(2): 73-9, 2009.
Article in English | MEDLINE | ID: mdl-19571499

ABSTRACT

PURPOSE: We investigated the feasibility of 3D hyperpolarized (HP) (129)Xe magnetic resonance (MR) imaging at an extremely low concentration of HP (129)Xe supplied from a continuous flow-type hyperpolarizing (CF-HP) system and established a standard procedure for measuring regional lung ventilation of small animals, such as the mouse, as a baseline for further studies. MATERIALS AND METHODS: We performed 3D HP (129)Xe MR imaging of the lungs of 2 healthy and 2 emphysematous mice that were spontaneously breathing diluted HP (129)Xe (<1%). From the three 3D MR images acquired by varying the flip angle of the radiofrequency (RF) pulse, we calculated the time constant of regional recovery, tau'(rep), which represents the time required for HP (129)Xe magnetization to be replenished approximately 63% after destruction of hyperpolarization by RF saturation pulse. After calculating the tau'(rep) maps, we examined the validity of our method. RESULTS: We used diluted xenon from the CF-HP system to acquire 3D HP (129)Xe MR images of the mouse lung that were undiminished under spontaneous respiration. The averaged tau'(rep) values were longer for the emphysematous lungs than for the healthy lungs, which reflected ventilation defects in the emphysematous lung. CONCLUSIONS: This procedure permitted us to estimate the regional lung ventilation for any arbitrarily set slice, and it will provide a standard for measuring regional lung ventilation as a baseline for further studies.


Subject(s)
Lung/anatomy & histology , Magnetic Resonance Imaging/methods , Animals , Equipment Design , Feasibility Studies , Imaging, Three-Dimensional , Magnetic Resonance Imaging/instrumentation , Male , Mice , Mice, Inbred Strains , Xenon Isotopes
16.
Anal Sci ; 35(8): 869-873, 2019 Aug 10.
Article in English | MEDLINE | ID: mdl-30982799

ABSTRACT

Hyperpolarized (HP) 129Xe NMR and MRI have enabled 129Xe studies with extraordinarily enhanced sensitivity, stimulating new developments in magnetic resonance in chemistry, physics, biology and medicine. However, the standard method of HP 129Xe production inevitably demands Rb vapor for the excitation, which has made the method very sensitive to impurities such as water or oxygen. This is the case especially in the recirculating system. In the present study, stability of the hyperpolarizing system is discussed by proposing the "cell decay constant", which symbolizes the decay rate of the NMR signal obtained from the system. The cell decay constant is effectively decreased to 1/3 by introducing separated chambers and mechanical stirring of the alkali metals used in the system, making it effective for accumulating FIDs over 30 to 100 h. The newly developed hyperpolarizing system has been successfully applied for newly detecting a broad signal at 190 ppm with an industrial material Nanofiber.

17.
Stem Cells Int ; 2019: 5179172, 2019.
Article in English | MEDLINE | ID: mdl-31281377

ABSTRACT

Chronic obstructive pulmonary disease is a leading cause of mortality globally, with no effective therapy yet established. Adipose tissue-derived stem cells (ADSCs) are useful for ameliorating lung injury in animal models. However, whether ADSCs differentiate into functional cells remains uncertain, and no study has reported on the mechanism by which ADSCs improve lung functionality. Thus, in this study, we examined whether ADSCs differentiate into lung alveolar cells and are able to ameliorate lung injury caused by elastase-induced emphysema in model mice. Here, we induced ADSCs to differentiate into type 2 alveolar epithelial cells in vitro. We demonstrated that ADSCs can differentiate into type 2 alveolar epithelial cells in an elastase-induced emphysematous lung and that ADSCs improve pulmonary function of emphysema model mice, as determined with spirometry and 129Xe MRI. These data revealed a novel function for ADSCs in promoting repair of the damaged lung by direct differentiation into alveolar epithelial cells.

18.
Magn Reson Med Sci ; 7(4): 179-85, 2008.
Article in English | MEDLINE | ID: mdl-19110512

ABSTRACT

We established a simple method for measuring and quantifying uptake dynamics of hyperpolarized (HP) (129)Xe in mouse brain, which includes application of a saturation recovery pulse sequence under controlled flow of HP (129)Xe. The technique allows pursuit of the time-dependent change in (129)Xe nuclear magnetic resonance signal in the uptake process without effect from radiofrequency destruction of the polarization and the dynamics in mouse lung. The uptake behavior is well described by a simple model that depends only on a decay rate constant comprising cerebral blood flow and the longitudinal relaxation rate of HP (129)Xe in the brain tissue. The improved analysis enabled precise determination of the decay rate constant as 0.107+/-0.013 s(-1) (+/-standard deviation, n=5), leading to estimation of longitudinal relaxation time, T(1i), as 15.3+/-3.5 s.


Subject(s)
Brain Chemistry , Magnetic Resonance Spectroscopy/methods , Xenon Isotopes/pharmacokinetics , Algorithms , Animals , Lung/chemistry , Male , Mice , Models, Biological , Xenon Isotopes/chemistry
19.
Magn Reson Med Sci ; 7(2): 65-72, 2008.
Article in English | MEDLINE | ID: mdl-18603837

ABSTRACT

The use of hyperpolarized (HP) 129Xe magnetic resonance (MR) imaging to regionally evaluate gas diffusion and perfusion processes as well as ventilation in the lung has been expected. In this study, we used a continuous-flow hyperpolarizing (CF-HP) system to acquire gas- and dissolved-phase 129Xe images from mouse lung, employing standard gradient echo sequence equipped with chemical shift selective excitation and 90 degrees flip angle. The character of non-recoverable HP magnetization enabled the use of a phase (frequency)-selective 90 degrees pulse for direct visualization of only a given-phase 129Xe magnetization replenished into the slice during repetition time (TR). We combined gas- and dissolved-phase 129Xe images to map the ratio of dissolved- to gas-phase 129Xe replenished into the slice during TR (Mdissolved/Mgas) and found it to be approximately 0.05 to 0.08 in the peripheral regions of mouse lungs. This result suggested that replenishment of dissolved-phase 129Xe magnetization by gas diffusion and pulmonary perfusion would be faster than that of gas-phase by ventilation. The use of a CF-HP system that allows the application of relatively long TR to HP 129Xe imaging using a phase-selective 90 degrees pulse would be useful in evaluating gas transport mechanisms in the lung.


Subject(s)
Contrast Media/administration & dosage , Flow Injection Analysis/instrumentation , Image Enhancement/instrumentation , Image Enhancement/methods , Lung/anatomy & histology , Magnetic Resonance Imaging/instrumentation , Xenon Isotopes/administration & dosage , Administration, Inhalation , Animals , Equipment Design , Equipment Failure Analysis , Flow Injection Analysis/methods , Male , Mice , Mice, Inbred Strains , Sensitivity and Specificity , Static Electricity
20.
Magn Reson Med Sci ; 17(4): 331-337, 2018 Oct 10.
Article in English | MEDLINE | ID: mdl-29526883

ABSTRACT

PURPOSE: High Mobility Group Box1 (HMGB1), which is one of the damage-associated molecular pattern molecules relating to various inflammatory diseases, has gained interest as a therapeutic target because of its involvement in wound healing processes. In the present study, we investigated HMGB1 as a potential therapeutic target in a model of lung fibrosis using a preclinical hyperpolarized 129Xe (HPXe) MRI system. METHODS: Lung injury was induced by intra-peritoneal injection of bleomycin (BLM) in 19 mice. Three weeks post-injection (when fibrosis was confirmed histologically), administration of ethyl pyruvate (EP) and alogliptin (ALG), which are down- and up-regulators of HMGB1, respectively, was commenced in six and seven of the 19 mice, respectively, and continued for a further 3 weeks. A separate sham-instilled group was formed of five mice, which were administered with saline for 6 weeks. Over the second 3-week period, the effects of disease progression and pharmacological therapy in the four groups of mice were monitored by HPXe MRI metrics of fractional ventilation and gas-exchange function. RESULTS: Gas-exchange function in BLM mice was significantly reduced after 3 weeks of BLM challenge compared to sham-instilled mice (P < 0.05). Ethyl pyruvate was found to improve HPXe MRI metrics of both ventilation and gas exchange, and repair tissue damage (assessed histologically), to a similar level as sham-instilled mice (P < 0.05), whilst ALG treatment caused no significant improvement of pulmonary function. CONCLUSION: This study demonstrates the down-regulator of HMGB1, EP, as a potential therapeutic agent for pulmonary fibrosis, as assessed by a non-invasive HPXe MRI protocol.


Subject(s)
Lung Injury , Lung , Magnetic Resonance Imaging/methods , Pyruvates/pharmacology , Animals , Bleomycin/adverse effects , Lung/diagnostic imaging , Lung/drug effects , Lung Injury/chemically induced , Lung Injury/diagnostic imaging , Mice , Pyruvates/administration & dosage , Xenon Isotopes/administration & dosage
SELECTION OF CITATIONS
SEARCH DETAIL