Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Eur J Clin Microbiol Infect Dis ; 43(1): 95-104, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37964043

ABSTRACT

PURPOSE: The duration of antibiotic treatment for prosthetic valve endocarditis caused by Streptococcus spp. is largely based on clinical observations and expert opinion rather than empirical studies. Here we assess the impact of a shorter antibiotic duration. OBJECTIVES: To assess the impact of antibiotic treatment duration for streptococcal prosthetic valve endocarditis on 12-month mortality as well as subsequent morbidity resulting in additional cardiac surgical interventions, and rates of relapse and reinfection. METHODS: This retrospective multisite (N= 3) study examines two decades of data on patients with streptococcal prosthetic valve endocarditis receiving either 4 or 6 weeks of antibiotics. Overall mortality, relapse, and reinfection rates were also assessed for the entire available follow-up period. RESULTS: The sample includes 121 patients (median age 72 years, IQR [53; 81]). The majority (74%, 89/121) received a ß-lactam antibiotic combined with aminoglycoside in 74% (89/121, median bi-therapy 5 days [1; 14]). Twenty-eight patients underwent surgery guided by ESC-guidelines (23%). The 12-month mortality rate was not significantly affected by antibiotic duration (4/40, 10% in the 4-week group vs 3/81, 3.7% in the 6-week group, p=0.34) or aminoglycoside usage (p=0.1). Similarly, there were no significant differences between the 2 treatment groups for secondary surgical procedures (7/40 vs 21/81, p=0.42), relapse or reinfection (1/40 vs 2/81 and 2/40 vs 5/81 respectively). CONCLUSIONS: Our study found no increased adverse outcomes associated with a 4-week antibiotic duration compared to the recommended 6-week regimen. Further randomized trials are needed to ascertain the optimal duration of treatment for streptococcal endocarditis.


Subject(s)
Endocarditis, Bacterial , Endocarditis , Heart Valve Prosthesis , Aged , Humans , Aminoglycosides/therapeutic use , Anti-Bacterial Agents/therapeutic use , Duration of Therapy , Endocarditis/drug therapy , Endocarditis/etiology , Endocarditis, Bacterial/microbiology , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis/microbiology , Prognosis , Reinfection , Retrospective Studies , Streptococcus
2.
Protein Sci ; 9(4): 820-6, 2000 Apr.
Article in English | MEDLINE | ID: mdl-10794425

ABSTRACT

We have used differential scanning calorimetry to determine the effect of low concentrations (C = 0-2 M) of the osmolyte sarcosine on the Gibbs energy changes (deltaG) for the unfolding of hen-egg-white lysozyme, ribonuclease A, and ubiquitin, under the same buffer and pH conditions. We have also computed this effect on the basis of the additivity assumption and using published values of the transfer Gibbs energies for the amino acid side chains and the peptide backbone unit. The values thus predicted for the slope delta deltaG/deltaC agree with the experimental ones, but only if the unfolded state is assumed to be compact (that is, if the accessibility to solvent of the unfolded state is modeled using segments excised from native structures). The additivity-based calculations predict similar delta deltaG/deltaC values for the three proteins studied. We point out that, to the extent that this approximate constancy of delta deltaG/deltaC holds, osmolyte-induced increases in denaturation temperature will be larger for proteins with low unfolding enthalpy (small proteins that bury a large proportion of apolar surface). The experimental results reported here are consistent with this hypothesis.


Subject(s)
Proteins/chemistry , Sarcosine/chemistry , Calorimetry, Differential Scanning , Thermodynamics
3.
J Chromatogr A ; 1217(17): 2956-63, 2010 Apr 23.
Article in English | MEDLINE | ID: mdl-20299021

ABSTRACT

A semi-automatic flow-based method for the simultaneous determination of 9 pharmaceuticals and 3 hormones in water samples in a single analytical run is proposed. The analytes were retained on a solid-phase extraction sorbent column and 1 microL of the eluate analysed by gas chromatography in combination with electron impact ionization mass spectrometry in the SIM mode. The sorbent used, Oasis-HLB, provided near-quantitative recovery of all analytes. The proposed method was validated with quite good analytical results including low limits of detection (0.01-0.06 ng L(-1) for 100 mL of water) and good linearity (r2>0.993) throughout the studied concentration ranges. The method provided good accuracy (recoveries of 85-103%) and precision (between- and within-day RSD values less than 7%) in the determination of the pharmaceuticals and hormones in tap, river, pond, well, swimming pool and wastewater.


Subject(s)
Environmental Monitoring/methods , Gas Chromatography-Mass Spectrometry/methods , Hormones/analysis , Pharmaceutical Preparations/analysis , Solid Phase Extraction/methods , Water Pollutants, Chemical/analysis , Limit of Detection
SELECTION OF CITATIONS
SEARCH DETAIL