Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Small ; 19(11): e2207017, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36564357

RESUMEN

The contact lens (CL) industry has made great strides in improving CL-wearing experiences. However, a large amount of CL wearers continue to experience ocular dryness, known as contact lens-induced dry eye (CLIDE), stemming from the reduction in tear volume, tear film instability, increased tear osmolarity followed by inflammation and resulting in ocular discomfort and visual disturbances. In this article, to address tear film thinning between the CL and the ocular surface, the concept of using a CL with microchannels to deliver the tears from the pre-lens tear film (PrLTF) to the post-lens ocular surface using in vitro eye-blink motion is investigated. This study reports an eye-blink mimicking system with microfluidic poly(2-hydroxyethyl methacrylate) (poly(HEMA)) hydrogel with integrated microchannels to demonstrate eye-blink assisted flow through microchannels. This in vitro experimental study provides a proof-of-concept result that tear transport from PrLTF to post-lens tear film can be enhanced by an artificial eyelid motion in a pressure range of 0.1-5 kPa (similar to human eyelid pressure) through poly(HEMA) microchannels. Simulation is conducted to support the hypothesis. This work demonstrates the feasibility of developing microfluidic CLs with the potential to help prevent or minimize CLIDE and discomfort by the enhanced transport of pre-lens tears to the post-lens ocular surface.


Asunto(s)
Lentes de Contacto Hidrofílicos , Síndromes de Ojo Seco , Humanos , Microfluídica , Síndromes de Ojo Seco/etiología , Ojo
2.
Biomed Microdevices ; 25(4): 37, 2023 09 23.
Artículo en Inglés | MEDLINE | ID: mdl-37740819

RESUMEN

Trans-endothelial electrical resistance (TEER) is one of the most widely used indicators to quantify the barrier integrity of endothelial layers. Over the last decade, the integration of TEER sensors into organ-on-a-chip (OOC) platforms has gained increasing interest for its efficient and effective measurement of TEER in OOCs. To date, microfabricated electrodes or direct insertion of wires has been used to integrate TEER sensors into OOCs, with each method having advantages and disadvantages. In this study, we developed a TEER-SPE chip consisting of carbon-based screen-printed electrodes (SPEs) embedded in a poly(methyl methacrylate) (PMMA)-based multi-layered microfluidic device with a porous poly(ethylene terephthalate) membrane in-between. As proof of concept, we demonstrated the successful cultures of hCMEC/D3 cells and the formation of confluent monolayers in the TEER-SPE chip and obtained TEER measurements for 4 days. Additionally, the TEER-SPE chip could detect changes in the barrier integrity due to shear stress or an inflammatory cytokine (i.e., tumor necrosis factor-α). The novel approach enables a low-cost and facile fabrication of carbon-based SPEs on PMMA substrates and the subsequent assembly of PMMA layers for rapid prototyping. Being cost-effective and cleanroom-free, our method lowers the existing logistical and technical barriers presenting itself as another step forward to the broader adoption of OOCs with TEER measurement capability.


Asunto(s)
Sistemas Microfisiológicos , Polimetil Metacrilato , Impedancia Eléctrica , Carbono , Electrodos
3.
J Nanobiotechnology ; 21(1): 316, 2023 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-37667307

RESUMEN

Spinal cord injury (SCI) is accompanied by loss of Zn2+, which is an important cause of glutamate excitotoxicity and death of local neurons as well as transplanted stem cells. Dental pulp stem cells (DPSCs) have the potential for neural differentiation and play an immunomodulatory role in the microenvironment, making them an ideal cell source for the repair of central nerve injury, including SCI. The zeolitic imidazolate framework 8 (ZIF-8) is usually used as a drug and gene delivery carrier, which can release Zn2+ sustainedly in acidic environment. However, the roles of ZIF-8 on neural differentiation of DPSCs and the effect of combined treatment on SCI have not been explored. ZIF-8-introduced DPSCs were loaded into gelatin methacryloyl (GelMA) hydrogel and in situ injected into the injured site of SCI rats. Under the effect of ZIF-8, axon number and axon length of DPSCs-differentiated neuro-like cells were significantly increased. In addition, ZIF-8 protected transplanted DPSCs from apoptosis in the damaged microenvironment. ZIF-8 promotes neural differentiation and angiogenesis of DPSCs by activating the Mitogen-activated protein kinase (MAPK) signaling pathway, which is a promising transport nanomaterial for nerve repair.


Asunto(s)
Estructuras Metalorgánicas , Traumatismos de la Médula Espinal , Animales , Ratas , Estructuras Metalorgánicas/farmacología , Pulpa Dental , Traumatismos de la Médula Espinal/terapia , Apoptosis , Diferenciación Celular
4.
Small ; 18(39): e2201401, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35978444

RESUMEN

The human brain and central nervous system (CNS) present unique challenges in drug development for neurological diseases. One major obstacle is the blood-brain barrier (BBB), which hampers the effective delivery of therapeutic molecules into the brain while protecting it from blood-born neurotoxic substances and maintaining CNS homeostasis. For BBB research, traditional in vitro models rely upon Petri dishes or Transwell systems. However, these static models lack essential microenvironmental factors such as shear stress and proper cell-cell interactions. To this end, organ-on-a-chip (OoC) technology has emerged as a new in vitro modeling approach to better recapitulate the highly dynamic in vivo human brain microenvironment so-called the neural vascular unit (NVU). Such BBB-on-a-chip models have made substantial progress over the last decade, and concurrently there has been increasing interest in modeling various neurological diseases such as Alzheimer's disease and Parkinson's disease using OoC technology. In addition, with recent advances in other scientific technologies, several new opportunities to improve the BBB-on-a-chip platform via multidisciplinary approaches are available. In this review, an overview of the NVU and OoC technology is provided, recent progress and applications of BBB-on-a-chip for personalized medicine and drug discovery are discussed, and current challenges and future directions are delineated.


Asunto(s)
Enfermedad de Alzheimer , Barrera Hematoencefálica , Transporte Biológico , Encéfalo , Humanos , Dispositivos Laboratorio en un Chip
5.
Artif Organs ; 46(7): E211-E243, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35349178

RESUMEN

BACKGROUND: Tissue engineering provides various strategies to fabricate an appropriate microenvironment to support the repair and regeneration of lost or damaged tissues. In this matter, several technologies have been implemented to construct close-to-native three-dimensional structures at numerous physiological scales, which are essential to confer the functional characteristics of living tissues. METHODS: In this article, we review a variety of microfabrication technologies that are currently utilized for several tissue engineering applications, such as soft lithography, microneedles, templated and self-assembly of microstructures, microfluidics, fiber spinning, and bioprinting. RESULTS: These technologies have considerably helped us to precisely manipulate cells or cellular constructs for the fabrication of biomimetic tissues and organs. Although currently available tissues still lack some crucial functionalities, including vascular networks, innervation, and lymphatic system, microfabrication strategies are being proposed to overcome these issues. Moreover, the microfabrication techniques that have progressed to the preclinical stage are also discussed. CONCLUSIONS: This article aims to highlight the advantages and drawbacks of each technique and areas of further research for a more comprehensive and evolving understanding of microfabrication techniques in terms of tissue engineering and regenerative medicine applications.


Asunto(s)
Bioimpresión , Ingeniería de Tejidos , Microtecnología , Impresión Tridimensional , Medicina Regenerativa/métodos , Ingeniería de Tejidos/métodos , Andamios del Tejido/química
6.
Small ; 17(45): e2100692, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34310048

RESUMEN

Viral infection is one of the leading causes of mortality worldwide. The growth of globalization significantly increases the risk of virus spreading, making it a global threat to future public health. In particular, the ongoing coronavirus disease 2019 (COVID-19) pandemic outbreak emphasizes the importance of devices and methods for rapid, sensitive, and cost-effective diagnosis of viral infections in the early stages by which their quick and global spread can be controlled. Micro and nanoscale technologies have attracted tremendous attention in recent years for a variety of medical and biological applications, especially in developing diagnostic platforms for rapid and accurate detection of viral diseases. This review addresses advances of microneedles, microchip-based integrated platforms, and nano- and microparticles for sampling, sample processing, enrichment, amplification, and detection of viral particles and antigens related to the diagnosis of viral diseases. Additionally, methods for the fabrication of microchip-based devices and commercially used devices are described. Finally, challenges and prospects on the development of micro and nanotechnologies for the early diagnosis of viral diseases are highlighted.


Asunto(s)
COVID-19 , Virosis , Humanos , Nanotecnología , Pandemias , SARS-CoV-2 , Virosis/diagnóstico
7.
IEEE Electron Device Lett ; 42(1): 46-49, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33746352

RESUMEN

Wearable and implantable pressure sensors are in great demand for personalized health monitoring. Pressure sensors with low operation voltage and low power-consumption are desired for energy-saving devices. Organic iontronic devices, such as organic electrochemical transistors (OECTs), have demonstrated great potential for low power-consumption bioelectronic sensing applications. The ability to conduct both electrons and ions, in addition to their low-operation voltage has enabled the widespread use of OECTs in different biosensing fields. However, despite these merits, OECTs have not been demonstrated for pressure sensing applications. This is because most OECTs are gated with aqueous electrolyte, which fails to respond to external pressure. Here, a low power-consumption iontronic pressure sensor is presented based on an OECT, in which an ionic hydrogel is used as a solid gating medium. The resultant iontronic device operated at voltages less than 1 V, with a power-consumption between ~ 101-103 µW, while maintaining a tunable sensitivity between 1 ~ 10 kPa-1. This work places OECTs on the frontline for developing low power-consumption iontronic pressure sensors and for biosensing applications.

8.
Nano Lett ; 19(1): 100-107, 2019 01 09.
Artículo en Inglés | MEDLINE | ID: mdl-30512954

RESUMEN

The tip-enhanced Raman spectroscopy (TERS) imaging technique is designed to provide correlated morphological and chemical information with a nanoscale spatial resolution by utilizing the plasmonic resonance supported by metallic nanostructures at the tip apex of a scanning probe. However, limited by the scattering cross sections of these nanostructures, only a small fraction of the incident light can be coupled to the plasmonic resonance to generate Raman signals. The uncoupled light then directly excites background spectra with a diffraction-limited resolution, which becomes the background noise that often blurs the TERS image. Here, we demonstrate how this problem can be solved by physically separating the light excitation region from the Raman signal generation region on the scanning probe. The remote-excitation TERS (RE-TERS) probe, which can be fabricated with a facile, robust and reproducible method, utilizes silver nanoparticles as nanoantennas to mediate the coupling of free-space excitation light to propagating surface plasmon polaritons (SPPs) in a sharp-tip silver nanowire to excite Raman signals remotely. With this RE-TERS probe, a 10 nm spatial resolution was demonstrated on a single-walled carbon nanotube sample, and the strain distribution in a monolayer molybdenum disulfide (MoS2) was mapped.

10.
Nano Lett ; 17(11): 6961-6967, 2017 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-29058919

RESUMEN

A simple and clean method of transferring two-dimensional (2D) materials plays a critical role in the fabrication of 2D electronics, particularly the heterostructure devices based on the artificial vertical stacking of various 2D crystals. Currently, clean transfer techniques rely on sacrificial layers or bulky crystal flakes (e.g., hexagonal boron nitride) to pick up the 2D materials. Here, we develop a capillary-force-assisted clean-stamp technique that uses a thin layer of evaporative liquid (e.g., water) as an instant glue to increase the adhesion energy between 2D crystals and polydimethylsiloxane (PDMS) for the pick-up step. After the liquid evaporates, the adhesion energy decreases, and the 2D crystal can be released. The thin liquid layer is condensed to the PDMS surface from its vapor phase, which ensures the low contamination level on the 2D materials and largely remains their chemical and electrical properties. Using this method, we prepared graphene-based transistors with low charge-neutral concentration (3 × 1010 cm-2) and high carrier mobility (up to 48 820 cm2 V-1 s-1 at room temperature) and heterostructure optoelectronics with high operation speed. Finally, a capillary-force model is developed to explain the experiment.

11.
Nano Lett ; 16(11): 6896-6902, 2016 11 09.
Artículo en Inglés | MEDLINE | ID: mdl-27739683

RESUMEN

Despite many efforts to fabricate high-aspect-ratio atomic force microscopy (HAR-AFM) probes for high-fidelity, high-resolution topographical imaging of three-dimensional (3D) nanostructured surfaces, current HAR probes still suffer from unsatisfactory performance, low wear-resistivity, and extravagant prices. The primary objective of this work is to demonstrate a novel design of a high-resolution (HR) HAR AFM probe, which is fabricated through a reliable, cost-efficient benchtop process to precisely implant a single ultrasharp metallic nanowire on a standard AFM cantilever probe. The force-displacement curve indicated that the HAR-HR probe is robust against buckling and bending up to 150 nN. The probes were tested on polymer trenches, showing a much better image fidelity when compared with standard silicon tips. The lateral resolution, when scanning a rough metal thin film and single-walled carbon nanotubes (SW-CNTs), was found to be better than 8 nm. Finally, stable imaging quality in tapping mode was demonstrated for at least 15 continuous scans indicating high resistance to wear. These results demonstrate a reliable benchtop fabrication technique toward metallic HAR-HR AFM probes with performance parallel or exceeding that of commercial HAR probes, yet at a fraction of their cost.

12.
Biosensors (Basel) ; 14(2)2024 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-38392005

RESUMEN

The convergence of microfluidics and organ-on-a-chip (OoC) technologies has revolutionized our ability to create advanced in vitro models that recapitulate complex physiological processes [...].


Asunto(s)
Microfluídica , Ingeniería de Tejidos , Sistemas Microfisiológicos , Evaluación Preclínica de Medicamentos , Dispositivos Laboratorio en un Chip
13.
Exploration (Beijing) ; 4(2): 20220150, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38855618

RESUMEN

The progress of brain synaptic devices has witnessed an era of rapid and explosive growth. Because of their integrated storage, excellent plasticity and parallel computing, and system information processing abilities, various field effect transistors have been used to replicate the synapses of a human brain. Organic semiconductors are characterized by simplicity of processing, mechanical flexibility, low cost, biocompatibility, and flexibility, making them the most promising materials for implanted brain synaptic bioelectronics. Despite being used in numerous intelligent integrated circuits and implantable neural linkages with multiple terminals, organic synaptic transistors still face many obstacles that must be overcome to advance their development. A comprehensive review would be an excellent tool in this respect. Therefore, the latest advancements in implantable neural links based on organic synaptic transistors are outlined. First, the distinction between conventional and synaptic transistors are highlighted. Next, the existing implanted organic synaptic transistors and their applicability to the brain as a neural link are summarized. Finally, the potential research directions are discussed.

14.
Bioengineering (Basel) ; 11(2)2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38391624

RESUMEN

Glaucoma is a leading cause of irreversible blindness, and early detection and treatment are crucial for preventing vision loss. This review aims to provide an overview of current diagnostic and treatment standards, recent medical and technological advances, and current challenges and future outlook for wearable glaucoma diagnostics and therapeutics. Conventional diagnostic techniques, including the rebound tonometer and Goldmann Applanation Tonometer, provide reliable intraocular pressure (IOP) measurement data at single-interval visits. The Sensimed Triggerfish and other emerging contact lenses provide continuous IOP tracking, which can improve diagnostic IOP monitoring for glaucoma. Conventional therapeutic techniques include eye drops and laser therapies, while emerging drug-eluting contact lenses can solve patient noncompliance with eye medications. Theranostic platforms combine diagnostic and therapeutic capabilities into a single device. Advantages of these platforms include real-time monitoring and personalized medication dosing. While there are many challenges to the development of wearable glaucoma diagnostics and therapeutics, wearable technologies hold great potential for enhancing glaucoma management by providing continuous monitoring, improving medication adherence, and reducing the disease burden on patients and healthcare systems. Further research and development of these technologies will be essential to optimizing patient outcomes.

15.
Acta Biomater ; 173: 231-246, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38465268

RESUMEN

Enterocutaneous fistula (ECF) is a severe medical condition where an abnormal connection forms between the gastrointestinal tract and skin. ECFs are, in most cases, a result of surgical complications such as missed enterotomies or anastomotic leaks. The constant leakage of enteric and fecal contents from the fistula site leads to skin breakdown and increases the risk of infection. Despite advances in surgical techniques and postoperative management, ECF accounts for significant mortality rates, estimated between 15-20%, and causes debilitating morbidity. Therefore, there is a critical need for a simple and effective method to seal and heal ECF. Injectable hydrogels with combined properties of robust mechanical properties and cell infiltration/proliferation have the potential to block and heal ECF. Herein, we report the development of an injectable nanoengineered adhesive hydrogel (INAH) composed of a synthetic nanosilicate (Laponite®) and a gelatin-dopamine conjugate for treating ECF. The hydrogel undergoes fast cross-linking using a co-injection method, resulting in a matrix with improved mechanical and adhesive properties. INAH demonstrates appreciable blood clotting abilities and is cytocompatible with fibroblasts. The adhesive properties of the hydrogel are demonstrated in ex vivo adhesion models with skin and arteries, where the volume stability in the hydrated internal environment facilitates maintaining strong adhesion. In vivo assessments reveal that the INAH is biocompatible, supporting cell infiltration and extracellular matrix deposition while not forming fibrotic tissue. These findings suggest that this INAH holds promising translational potential for sealing and healing ECF.


Asunto(s)
Fístula Intestinal , Adhesivos Tisulares , Humanos , Hidrogeles/farmacología , Adhesivos , Gelatina , Fístula Intestinal/terapia
16.
Adv Healthc Mater ; : e2302331, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38359321

RESUMEN

Patient-derived organoids (PDOs) developed ex vivo and in vitro are increasingly used for therapeutic screening. They provide a more physiologically relevant model for drug discovery and development compared to traditional cell lines. However, several challenges remain to be addressed to fully realize the potential of PDOs in therapeutic screening. This paper summarizes recent advancements in PDO development and the enhancement of PDO culture models. This is achieved by leveraging materials engineering and microfabrication technologies, including organs-on-a-chip and droplet microfluidics. Additionally, this work discusses the application of PDOs in therapy screening to meet diverse requirements and overcome bottlenecks in cancer treatment. Furthermore, this work introduces tools for data processing and analysis of organoids, along with their microenvironment. These tools aim to achieve enhanced readouts. Finally, this work explores the challenges and future perspectives of using PDOs in drug development and personalized screening for cancer patients.

17.
Bioact Mater ; 34: 164-180, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38343773

RESUMEN

Extracellular matrix (ECM) undergoes dynamic inflation that dynamically changes ligand nanospacing but has not been explored. Here we utilize ECM-mimicking photocontrolled supramolecular ligand-tunable Azo+ self-assembly composed of azobenzene derivatives (Azo+) stacked via cation-π interactions and stabilized with RGD ligand-bearing poly(acrylic acid). Near-infrared-upconverted-ultraviolet light induces cis-Azo+-mediated inflation that suppresses cation-π interactions, thereby inflating liganded self-assembly. This inflation increases nanospacing of "closely nanospaced" ligands from 1.8 nm to 2.6 nm and the surface area of liganded self-assembly that facilitate stem cell adhesion, mechanosensing, and differentiation both in vitro and in vivo, including the release of loaded molecules by destabilizing water bridges and hydrogen bonds between the Azo+ molecules and loaded molecules. Conversely, visible light induces trans-Azo+ formation that facilitates cation-π interactions, thereby deflating self-assembly with "closely nanospaced" ligands that inhibits stem cell adhesion, mechanosensing, and differentiation. In stark contrast, when ligand nanospacing increases from 8.7 nm to 12.2 nm via the inflation of self-assembly, the surface area of "distantly nanospaced" ligands increases, thereby suppressing stem cell adhesion, mechanosensing, and differentiation. Long-term in vivo stability of self-assembly via real-time tracking and upconversion are verified. This tuning of ligand nanospacing can unravel dynamic ligand-cell interactions for stem cell-regulated tissue regeneration.

18.
Biosensors (Basel) ; 13(7)2023 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-37504083

RESUMEN

Wearable sweat biosensors for noninvasive monitoring of health parameters have attracted significant attention. Having these biosensors embedded in textile substrates can provide a convenient experience due to their soft and flexible nature that conforms to the skin, creating good contact for long-term use. These biosensors can be easily integrated with everyday clothing by using textile fabrication processes to enhance affordable and scalable manufacturing. Herein, a flexible electrochemical glucose sensor that can be screen-printed onto a textile substrate has been demonstrated. The screen-printed textile-based glucose biosensor achieved a linear response in the range of 20-1000 µM of glucose concentration and high sensitivity (18.41 µA mM-1 cm-2, R2 = 0.996). In addition, the biosensors show high selectivity toward glucose among other interfering analytes and excellent stability over 30 days of storage. The developed textile-based biosensor can serve as a platform for monitoring bio analytes in sweat, and it is expected to impact the next generation of wearable devices.


Asunto(s)
Técnicas Biosensibles , Dispositivos Electrónicos Vestibles , Sudor , Glucosa , Textiles
19.
Bioact Mater ; 23: 314-327, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36439081

RESUMEN

Blood loss by hemorrhaging wounds accounts for over one-third of ∼5 million trauma fatalities worldwide every year. If not controlled in a timely manner, exsanguination can take lives within a few minutes. Developing new biomaterials that are easy to use by non-expert patients and promote rapid blood coagulation is an unmet medical need. Here, biocompatible, and biodegradable microneedle arrays (MNAs) based on gelatin methacryloyl (GelMA) biomaterial hybridized with silicate nanoplatelets (SNs) are developed for hemorrhage control. The SNs render the MNAs hemostatic, while the needle-shaped structure increases the contact area with blood, synergistically accelerating the clotting time from 11.5 min to 1.3 min in vitro. The engineered MNAs reduce bleeding by ∼92% compared with the untreated injury group in a rat liver bleeding model. SN-containing MNAs outperform the hemostatic effect of needle-free patches and a commercial hemostat in vivo via combining micro- and nanoengineered features. Furthermore, the tissue adhesive properties and mechanical interlocking support the suitability of MNAs for wound closure applications. These hemostatic MNAs may enable rapid hemorrhage control, particularly for patients in developing countries or remote areas with limited or no immediate access to hospitals.

20.
Adv Healthc Mater ; 12(31): e2301551, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37300448

RESUMEN

Hemorrhage and bacterial infections are major hurdles in the management of life-threatening surgical wounds. Most bioadhesives for wound closure lack sufficient hemostatic and antibacterial properties. Furthermore, they suffer from weak sealing efficacy, particularly for stretchable organs, such as the lung and bladder. Accordingly, there is an unmet need for mechanically robust hemostatic sealants with simultaneous antibacterial effects. Here, an injectable, photocrosslinkable, and stretchable hydrogel sealant based on gelatin methacryloyl (GelMA), supplemented with antibacterial zinc ferrite (ZF) nanoparticles and hemostatic silicate nanoplatelets (SNs) for rapid blood coagulation is nanoengineered. The hydrogel reduces the in vitro viability of Staphylococcus aureus by more than 90%. The addition of SNs (2% w/v) and ZF nanoparticles (1.5 mg mL-1 ) to GelMA (20% w/v) improves the burst pressure of perforated ex vivo porcine lungs by more than 40%. Such enhancement translated to ≈250% improvement in the tissue sealing capability compared with a commercial hemostatic sealant, Evicel. Furthermore, the hydrogels reduce bleeding by ≈50% in rat bleeding models. The nanoengineered hydrogel may open new translational opportunities for the effective sealing of complex wounds that require mechanical flexibility, infection management, and hemostasis.


Asunto(s)
Hemostáticos , Hidrogeles , Ratas , Porcinos , Animales , Hidrogeles/farmacología , Hemostáticos/farmacología , Hemostasis , Antibacterianos/farmacología , Silicatos/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA