Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 146
Filtrar
1.
Int J Gynecol Cancer ; 31(12): 1535-1540, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34711665

RESUMEN

INTRODUCTION: Although ultrasonography has been reported to have similar diagnostic accuracy to magnetic resonance imaging, it is not a standard imaging modality for cervical cancer. We aimed to summarize the ultrasonographic features of rare primary cervical cancer. METHODS: This was a retrospective study of patients with cervical cancer who were diagnosed between June 2014 and October 2019. They were divided into common-type cervical cancer (ie, cervical squamous cell carcinoma) and rare-type cervical cancer groups including adenocarcinoma, adenosquamous carcinoma, and small cell carcinoma. All patients were staged according to the tumor, nodes, and metastases criteria. RESULTS: Of the 64 patients, the diagnosis was suspected on ultrasonography in 61 (95.3%) patients and missed on ultrasonography in three patients. The tumor size was smaller in the rare-type cervical cancer group (p<0.05). Hypoechoic lesions in common-type cervical cancer and isoechoic lesions accounted for 74.4% (32/43) and 61.9% (13/21) of patients in the rare-type cervical cancer group, respectively (p<0.001). Meanwhile, 67.4% (29/43) of tumors in common-type cervical cancer were exophytic, while 66.7% (14/21) in rare-type cervical cancer were endophytic (p=0.01). Color Doppler blood signals, as compared with normal cervical tissue, were found in all patients. There was good consistency between ultrasonographic and pathologic diagnosis of rare-type cervical cancer (weighted kappa=0.87). CONCLUSIONS: Most patients with rare-type cervical cancer present with isoechoic lesions. The coincidence rate between ultrasonographic and pathologic diagnosis of rare-type cervical cancer is 87%.


Asunto(s)
Adenocarcinoma/patología , Carcinoma Adenoescamoso/patología , Carcinoma de Células Escamosas/patología , Neoplasias del Cuello Uterino/patología , Adenocarcinoma/diagnóstico por imagen , Adulto , Carcinoma Adenoescamoso/diagnóstico por imagen , Carcinoma de Células Escamosas/diagnóstico por imagen , Femenino , Humanos , Persona de Mediana Edad , Ultrasonografía Doppler en Color/métodos , Ultrasonografía Doppler en Color/normas , Neoplasias del Cuello Uterino/diagnóstico por imagen
2.
Neurocrit Care ; 32(2): 502-511, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31264072

RESUMEN

BACKGROUND: To report a consensus on the different competency levels for the elaboration of skill recommendations in performing brain ultrasonography within the neurocritical care setting. METHODS: Four brain ultrasound experts, supported by a methodologist, performed a preselection of indicators and skills based on the current literature and clinical expertise. An international panel of experts was recruited and subjected to web-based questionnaires according to a Delphi method presented in three separate rounds. A pre-defined threshold of agreement was established on expert subjective opinions, > 84% of votes was set to support a strong recommendation and > 68% for a weak recommendation. Below these thresholds, no recommendation reached. RESULTS: We defined four different skill levels (basic, basic-plus, pre-advanced, advanced). Twenty-five experts participated to the full process. After four rounds of questions, two items received a strong recommendation in the basic skill category, three in the advanced, twelve in the basic-plus, and seven in the pre-advanced. Two items in the pre-advanced category received a weak recommendation and three could not be collocated and were excluded from the list. CONCLUSIONS: Results from this consensus permitted stratification of the different ultrasound examination skills in four levels with progressively increasing competences. This consensus can be useful as a guide for beginners in brain ultrasonography and for the development of specific training programs within this field.


Asunto(s)
Competencia Clínica , Cuidados Críticos/normas , Ultrasonografía Doppler en Color/normas , Ultrasonografía Doppler Transcraneal/normas , Técnica Delphi , Ecoencefalografía/normas , Testimonio de Experto , Humanos
3.
Fetal Diagn Ther ; 47(2): 129-137, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31280268

RESUMEN

OBJECTIVE: Mean uterine artery pulsatility index (meanUAPI) is commonly measured at 11-13+6 weeks to predict adverse pregnancy outcomes including hypertensive disorders and small-for-gestational age. The aims of this study were to establish a population-specific reference range for meanUAPI at <11 weeks, to determine if an abnormal meanUAPI at <11 weeks was associated with adverse pregnancy outcome, and to assess changes in meanUAPI between <11 weeks and 11-13+6 weeks. METHODS: A prospective cohort was examined at <11 weeks and at 11-13+6 weeks to develop reference ranges for meanUAPI. Based on these regression models, meanUAPI Z-scores were compared between outcome groups using a two-sample t test. Longitudinal changes in the meanUAPI between <11 and 11-13+6 weeks were assessed by two-way mixed ANOVA. RESULTS: Prior to 11 weeks, there was no significant difference in meanUAPI between normal (n = 622) and adverse (n = 80) outcomes (mean [95% CI]: 2.62 [2.57-2.67] and 2.67 [2.50-2.84], respectively; p = 0.807). At 11-13+6 weeks, meanUAPI was significantly higher in the adverse (n = 66) compared with the normal (n = 535) outcome group (mean [95% CI]: 1.87 [1.70-2.03] and 1.67 [1.63-1.72], respectively; p = 0.040). There was a statistically significant decrease (p < 0.0001) in meanUAPI between the two time points. CONCLUSION: MeanUAPI measured at <11 weeks' gestation does not appear to be a useful marker for the prediction of placental-related adverse pregnancy outcomes, supporting an argument for the prediction of risk at 11-13+6 weeks' gestation.


Asunto(s)
Circulación Placentaria , Flujo Pulsátil , Ultrasonografía Doppler en Color , Ultrasonografía Prenatal , Arteria Uterina/diagnóstico por imagen , Adolescente , Adulto , Femenino , Retardo del Crecimiento Fetal/diagnóstico por imagen , Retardo del Crecimiento Fetal/fisiopatología , Edad Gestacional , Humanos , Recién Nacido Pequeño para la Edad Gestacional , Preeclampsia/diagnóstico por imagen , Preeclampsia/fisiopatología , Valor Predictivo de las Pruebas , Embarazo , Resultado del Embarazo , Estudios Prospectivos , Valores de Referencia , Ultrasonografía Doppler en Color/normas , Ultrasonografía Prenatal/normas , Arteria Uterina/fisiopatología , Adulto Joven
4.
Ultrasound Obstet Gynecol ; 53(2): 245-250, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-29917286

RESUMEN

OBJECTIVE: To assess the quality of mean uterine artery (UtA) pulsatility index (PI) measurement in a first-trimester pre-eclampsia screening program. METHODS: Consecutive women with a singleton pregnancy attending first-trimester screening for fetal chromosomal abnormalities also had combined screening for pre-eclampsia based on the Fetal Medicine Foundation (FMF) algorithm, at a large practice in Sydney, Australia, from May 2014 to February 2017. Distributions of mean UtA-PI multiples of the median (MoM) on a logarithmic scale were plotted in relation to the normal median with 95% CI for each operator and for each month. Central tendency and dispersion and cumulative sum charts were produced. Mean UtA-PI MoM values between 0.95 and 1.05 were considered ideal and those between 0.90 and 1.10 were considered acceptable. The screen-positive rates for preterm pre-eclampsia in different groups of sonographers according to their mean log10 UtA-PI MoM were calculated and compared using the chi-square test. RESULTS: A total of 21 010 women attended for first-trimester ultrasound and had screening for pre-eclampsia. The overall median UtA-PI MoM was 1.042 (interquartile range (IQR), 0.85-1.26). Of 46 sonographers, 42 (91.3%) performed more than 50 examinations and, of those, 41 (97.6%) measured UtA-PI within the acceptable range. Sonographers measuring UtA-PI MoM on average below 0.95 and those measuring it above 1.05 had, respectively, lower and higher screen-positive rates when compared with those with measurements within the 0.95-1.05 UtA-PI MoM interval (7.2% and 13.2% vs 11.2%, respectively, P < 0.001). CONCLUSION: UtA Doppler is measured well among trained operators when following an established protocol. While slight variations are expected, systematic error in this measurement impacts on the screen-positive rate. Therefore, a quality control process should be in place and retraining of staff may be required. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.


Asunto(s)
Preeclampsia/diagnóstico por imagen , Flujo Pulsátil , Ultrasonografía Doppler en Color/normas , Arteria Uterina/diagnóstico por imagen , Adulto , Errores Diagnósticos/prevención & control , Femenino , Humanos , Tamizaje Masivo/normas , Preeclampsia/prevención & control , Embarazo , Primer Trimestre del Embarazo , Estudios Prospectivos , Ultrasonografía Prenatal/normas , Arteria Uterina/fisiopatología
5.
Ultrasound Obstet Gynecol ; 51(6): 818-828, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-28944985

RESUMEN

OBJECTIVE: To describe the sonographic features of endometrial cancer in relation to tumor stage, grade and histological type, using the International Endometrial Tumor Analysis (IETA) terminology. METHODS: This was a prospective multicenter study of 1714 women with biopsy-confirmed endometrial cancer undergoing standardized transvaginal grayscale and Doppler ultrasound examination according to the IETA study protocol, by experienced ultrasound examiners using high-end ultrasound equipment. Clinical and sonographic data were entered into a web-based database. We assessed how strongly sonographic characteristics, according to IETA, were associated with outcome at hysterectomy, i.e. tumor stage, grade and histological type, using univariable logistic regression and the c-statistic. RESULTS: In total, 1538 women were included in the final analysis. Median age was 65 (range, 27-98) years, median body mass index was 28.4 (range 16-67) kg/m2 , 1377 (89.5%) women were postmenopausal and 1296 (84.3%) reported abnormal vaginal bleeding. Grayscale and color Doppler features varied according to grade and stage of tumor. High-risk tumors, compared with low-risk tumors, were less likely to have regular endometrial-myometrial junction (difference of -23%; 95% CI, -27 to -18%), were larger (mean endometrial thickness; difference of +9%; 95% CI, +8 to +11%), and were more likely to have non-uniform echogenicity (difference of +7%; 95% CI, +1 to +13%), a multiple, multifocal vessel pattern (difference of +21%; 95% CI, +16 to +26%) and a moderate or high color score (difference of +22%; 95% CI, +18 to +27%). CONCLUSION: Grayscale and color Doppler sonographic features are associated with grade and stage of tumor, and differ between high- and low-risk endometrial cancer. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Asunto(s)
Neoplasias Endometriales/diagnóstico por imagen , Clasificación del Tumor , Ultrasonografía Doppler en Color/normas , Adulto , Anciano , Anciano de 80 o más Años , Conferencias de Consenso como Asunto , Estudios Transversales , Neoplasias Endometriales/clasificación , Neoplasias Endometriales/patología , Femenino , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Terminología como Asunto
6.
Am J Emerg Med ; 36(7): 1166-1169, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29223688

RESUMEN

INTRODUCTION: Intubation is a frequently performed procedure in emergency medicine that is associated with significant morbidity and mortality when unrecognized esophageal intubation occurs. However, it may be difficult to visualize the endotracheal tube (ETT) in some patients. This study assessed whether the addition of color Doppler was able to improve the ability to visualize the ETT location. METHODS: This study was performed in a cadaver lab using three different cadavers chosen to represent varying neck circumference. Cadavers were randomized to tracheal or esophageal intubation. Blinded sonographers then assessed the location of the ETT using either grayscale or color Doppler imaging. Accuracy of sonographer identification of ETT location, time to identification, and operator confidence were assessed. RESULTS: One hundred and fifty intubations were performed and each was assessed by both standard and color Doppler techniques. There were 78 tracheal intubations and 72 esophageal intubations. The standard technique was 99.3% (95% CI 96.3 to 99.9%) accurate. The color flow technique was also 99.3% (95% CI 96.3 to 99.9%) accurate. The mean operator time to identification was 3.24s (95% CI 2.97 to 3.51s) in the standard approach and 5.75s (95% CI 5.16 to 6.33s) in the color flow technique. The mean operator confidence was 4.99/5.00 (95% CI 4.98 to 5.00) in the standard approach and 4.94/5.00 (95% CI 4.90 to 4.98) in the color flow technique. CONCLUSION: When added to standard ultrasound imaging, color flow did not improve accuracy or operator confidence for identifying ETT location and resulted in a longer examination time.


Asunto(s)
Intubación Intratraqueal , Cadáver , Competencia Clínica/normas , Esófago/diagnóstico por imagen , Humanos , Intubación , Cuello/anatomía & histología , Cuello/diagnóstico por imagen , Variaciones Dependientes del Observador , Sensibilidad y Especificidad , Método Simple Ciego , Ultrasonografía/normas , Ultrasonografía Doppler en Color/normas
7.
Muscle Nerve ; 56(6): 1101-1107, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28214343

RESUMEN

INTRODUCTION: The value of imaging the deep branch of the ulnar nerve (DBUN) over its entire course has not been clarified. Therefore, this study evaluates the feasibility of visualizing the DBUN from its origin to the most distal point. METHODS: We performed high-resolution ultrasound (HRUS) with high-frequency probes (18-22 MHZ), HRUS-guided ink marking, and consecutive dissection in 8 fresh cadaver hands. In both hands of 10 healthy volunteers (n = 20), the cross-sectional area (CSA) was measured at 2 different locations (R1 and R2). RESULTS: The DBUN was clearly visible in all anatomical specimens and in healthy volunteers. Dissection confirmed HRUS findings in all anatomical specimens. The mean CSA was 1.8 ± 0.5 mm2 at R1 and 1.6 ± 0.4 mm2 at R2. DISCUSSION: This study confirms that the DBUN can be reliably visualized over its entire course with HRUS in anatomical specimens and in healthy volunteers. Muscle Nerve 56: 1101-1107, 2017.


Asunto(s)
Nervio Cubital/anatomía & histología , Nervio Cubital/diagnóstico por imagen , Ultrasonografía Doppler en Color/normas , Adulto , Cadáver , Femenino , Mano/anatomía & histología , Mano/diagnóstico por imagen , Mano/inervación , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Distribución Aleatoria , Ultrasonografía Doppler en Color/métodos
8.
J Cardiothorac Vasc Anesth ; 31(3): 973-979, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28366714

RESUMEN

OBJECTIVES: To assess the feasibility and reliability of transthoracic echocardiography to measure inferior vena cava (IVC) diameter variation using a transhepatic view. DESIGN: Prospective cohort study. SETTING: Single-center hospital. PATIENTS: Forty consecutive patients undergoing elective cardiac surgery. INTERVENTIONS: Bedside transthoracic echocardiography. MEASUREMENTS AND MAIN RESULTS: Correlation between the two views was measured using Pearson R, while agreement was measured using the intraclass correlation coefficient (ICC). In a nested sub-study of 16 randomly selected participants, all images were re-rated by the same rater, who was blinded to the original measurement results, and by a second blinded operator. Correlation between the subcostal and transhepatic views was moderate when assessing maximum (R 0.46; 95% confidence interval [CI], 0.18-0.68), and minimum (R 0.55; CI, 0.29-0.74) IVC diameter. Correlation when measuring IVC diameter variation was higher (R 0.70; CI, 0.49-0.83). Agreement between the two views for IVC diameter variation measurement was substantial (ICC 0.73; CI, 0.49-0.85). Intra-rater reliability was excellent (ICC 0.95-0.99). CONCLUSIONS: Agreement between subcostal and transhepatic views was substantial for the assessment of IVC diameter variation; however, the magnitude of agreement was less than anticipated. Further research is needed to determine if the transhepatic view can be used reliably in the assessment of fluid responsiveness.


Asunto(s)
Ecocardiografía/métodos , Venas Hepáticas/diagnóstico por imagen , Ultrasonografía Doppler en Color/métodos , Vena Cava Inferior/diagnóstico por imagen , Anciano , Procedimientos Quirúrgicos Cardíacos/métodos , Procedimientos Quirúrgicos Cardíacos/normas , Estudios de Cohortes , Ecocardiografía/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Distribución Aleatoria , Método Simple Ciego , Ultrasonografía Doppler en Color/normas
9.
J Ultrasound Med ; 36(7): 1347-1354, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28449311

RESUMEN

OBJECTIVES: To estimate intraobserver and interobserver reproducibility for assigning an International Endometrial Tumor Analysis (IETA) group color score for endometrial vascularization on color Doppler imaging. METHODS: Sixty-eight endometrial 3-dimensional volumes from endometrial color Doppler assessments of women with different endometrial disorders were evaluated by 8 different examiners (4 skilled examiners and 4 obstetric and gynecologic trainees). One skilled examiner who did not participate in the assessments selected the 68 volumes from a database to select a balanced number of each IETA score. Each examiner evaluated the 68 endometrial volumes to assign the IETA color score (1, absence of vascularization; 2, low vascularization; 3, moderate vascularization; or 4, abundant vascularization) using tomographic ultrasound imaging. The analysis was repeated 4 weeks later, and interobserver and intraobserver reproducibility was analyzed by calculating the weighted κ index. The second of the measurements made by each observer was used to estimate interobserver reproducibility. RESULTS: The intraobserver reproducibility was very good for all examiners, with a weighted κ index ranging from 0.84 to 0.91. The interobserver reproducibility was good or very good for all estimated comparisons, with a weighted κ index ranging from 0.77 to 0.96, regardless of experience level. CONCLUSIONS: The reproducibility of assigning the IETA color score for assessing endometrial vascularization using 3-dimensional volumes is good or very good regardless of the experience of the examiner.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Endometrio/diagnóstico por imagen , Endometrio/fisiología , Interpretación de Imagen Asistida por Computador/normas , Imagenología Tridimensional/normas , Ultrasonografía Doppler en Color/normas , Adulto , Femenino , Humanos , Internacionalidad , Variaciones Dependientes del Observador , Tamaño de los Órganos , Guías de Práctica Clínica como Asunto , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
10.
Vascular ; 25(6): 612-617, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28423999

RESUMEN

Introduction To investigate the diagnostic accuracy of an automated toe blood pressure device for detecting peripheral arterial disease in older people. Methods Ninety participants underwent toe and brachial blood pressure measurements and colour duplex ultrasonography of the right lower limb. Peripheral arterial disease was diagnosed if > 50% arterial obstruction was identified in any lower limb vessel using colour duplex ultrasonography. A receiver operating characteristic curve was analysed and the sensitivity and specificity of commonly used toe brachial index and toe blood pressure values were determined. Results The optimum toe brachial index threshold value for diagnosing peripheral arterial disease was 0.72 (sensitivity 76.2%, specificity 75%). The area under the curve was 0.829 (95% CI 0.743 to 0.915, p < 0.0001) suggesting fair diagnostic accuracy. A toe blood pressure of 70 mmHg was found to have excellent specificity (97.92%) for detecting PAD but poor sensitivity (42.86%). Conclusions The accuracy of automated toe blood pressure and TBI measurements was determined to be good when using colour duplex ultrasound as the reference standard for the non-invasive diagnosis of peripheral arterial disease. Results should be interpreted in the context of all clinical signs and symptoms.


Asunto(s)
Índice Tobillo Braquial/instrumentación , Hemodinámica , Enfermedad Arterial Periférica/diagnóstico , Ultrasonografía Doppler en Color , Factores de Edad , Anciano , Anciano de 80 o más Años , Índice Tobillo Braquial/normas , Área Bajo la Curva , Automatización , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Valor Predictivo de las Pruebas , Curva ROC , Estándares de Referencia , Reproducibilidad de los Resultados , Ultrasonografía Doppler en Color/normas
11.
Fetal Diagn Ther ; 41(3): 239-240, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-27160715

RESUMEN

Vascular control is a fundamental step in the surgical management of morbidly adherent placenta (MAP), and this implies a precise knowledge of the vascular supply in the lower part of the genital tract. High degrees of MAP are sometimes characterised by the presence of a rich vascular anastomotic system between the bladder, uterus, and vagina involving the superior, medial, and inferior vaginal and the lower vesical arteries. This brief report shows that prenatal ultrasound assessment of bladder-uterovaginal anastomoses in MAP is feasible.


Asunto(s)
Enfermedades Placentarias/diagnóstico por imagen , Ultrasonografía Doppler en Color/normas , Ultrasonografía Prenatal/normas , Vejiga Urinaria/diagnóstico por imagen , Útero/diagnóstico por imagen , Femenino , Humanos , Embarazo , Ultrasonografía Doppler en Color/métodos , Ultrasonografía Prenatal/métodos
12.
J Vasc Surg ; 74(5): 1438-1439, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34022379
14.
BMC Ophthalmol ; 16(1): 214, 2016 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-27927176

RESUMEN

BACKGROUND: Colour Doppler analysis of ophthalmic vessels has been proposed as a promising tool in the diagnosis of various eye diseases, but the available diagnostic evidence has not yet been assessed systematically. We performed a comprehensive systematic review of the literature on the diagnostic properties of Colour Doppler imaging (CDI) assessing ophthalmic vessels and provide an inventory of the available evidence. METHODS: Eligible papers were searched electronically in (Pre) Medline, Embase and Scopus, and via cross-checking of reference lists. The minimum requirement to be included was the availability of original data and the possibility to construct a two-by-two table. Study selection, critical appraisal using the QUADAS II instrument and extraction of salient study characteristics was made in duplicate. Sensitivity and specificity was computed for each study. RESULTS: We included 11 studies (15 two-by-two tables) of moderate methodological quality enrolling 820 participants (range 30 to 118). In 44.4% participants were female (range 37-59% in specific subgroups). CDI was assessed for internal carotid stenosis, diabetic retinopathy, glaucoma, and branch or central retinal vein occlusion diagnosis. There was insufficient data to pool the results for specific illnesses. For the assessments of ophthalmic arteries, mean sensitivity was 0.69 (range 0.27-0.96) with a corresponding mean specificity of 0.83 (range 0.70-0.96). Mean sensitivity of the central retinal artery assessments was 0.58 (range 0.31-0.84) and the corresponding mean specificity was 0.82 (range 0.63-0.94). CONCLUSIONS: Robust assessments of the diagnostic value of colour Doppler analysis remain uncommon, limiting the possibilities to extrapolate its true potential for clinical practice. PROSPERO 2014:CRD42014014027.


Asunto(s)
Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Retinopatía Diabética/diagnóstico por imagen , Glaucoma/diagnóstico por imagen , Oclusión de la Vena Retiniana/diagnóstico por imagen , Ultrasonografía Doppler en Color/normas , Humanos , Arteria Oftálmica/diagnóstico por imagen , Flujo Sanguíneo Regional , Arteria Retiniana/diagnóstico por imagen , Sensibilidad y Especificidad
15.
J Vasc Surg ; 62(5): 1236-44, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26506272

RESUMEN

OBJECTIVE: Duplex ultrasonography (DUS) has been the mainstay for diagnosing carotid artery stenosis and is often the sole diagnostic modality used prior to intervention. Highly calcified plaque, however, results in an acoustic shadow (AcS) that obscures the vessel lumen and inhibits the sonographer's ability to obtain Doppler velocity measurements. It is unknown whether DUS can accurately determine the degree of carotid stenosis in these settings. METHODS: From July 2012 to December 2013, all patients with AcS on DUS measuring ≥5 mm in the longitudinal axis were cross-referenced with multidetector computed tomographic angiography (MD-CTA) images of the neck to define the study population. After standardizing the MD-CTA windows, percent stenosis was determined by cross-sectional area reduction using two separate previously described methods based on North American Symptomatic Carotid Endarterectomy Trial (NASCET) and European Carotid Surgery Trial (ECST) criteria. DUS waveform parameters in the internal carotid artery near the AcS were then compared with these MD-CTA measurements to determine the accuracy of DUS in characterizing the severity of carotid stenosis. RESULTS: During this period, 8517 DUS studies were performed at the Massachusetts General Hospital, 550 of which had AcS, for an incidence of 6.45%. There were 92 lesions with a concomitant MD-CTA; however, seven were excluded because of poor study quality, because ≥6 months had elapsed between DUS and MD-CTA, or because the patient had undergone carotid reconstruction between studies. Of the 85 remaining lesions, DUS characterized 17 as severe (peak systolic velocity [PSV] >250 cm/s), 31 as moderate (PSV = 151-250 cm/s), and 37 as mild (PSV ≤150 cm/s) stenoses using PSV criteria. PSV weakly correlated with CTA-NASCET (r = 0.361; P = .004) and CTA-ECST (r = 0.306; P = .004) percent stenosis. Using PSV >250 cm/s as the predictor of >70% stenosis, and a ≥70% cutoff by both CTA-ECST and CTA-NASCET methods as the reference measure, DUS sensitivity ranged from 22.7% to 32.5%, specificity from 89.4% to 91.1%, positive predictive value from 88.2% to 76.4%, and negative predictive value from 25% to 60.2%. A subgroup analysis of lesions identified as non-severe by DUS revealed that waveforms with lower deceleration were associated with severe stenosis on CTA. CONCLUSIONS: In the presence of AcS, DUS alone is inadequate to accurately determine the degree of carotid stenosis with sensitivity, specificity, and negative predictive values far below that needed for clinical decision-making. MD-CTA may be necessary for improved characterization of plaque in these AcS lesions. Further studies are needed to determine DUS parameters that may identify patients who should undergo further evaluation with MD-CTA to characterize the true severity of the stenosis.


Asunto(s)
Arteria Carótida Interna/diagnóstico por imagen , Estenosis Carotídea/diagnóstico por imagen , Ultrasonografía Doppler en Color , Calcificación Vascular/diagnóstico por imagen , Humanos , Interpretación de Imagen Asistida por Computador , Tomografía Computarizada Multidetector , Placa Aterosclerótica , Valor Predictivo de las Pruebas , Estándares de Referencia , Reproducibilidad de los Resultados , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Ultrasonografía Doppler en Color/normas
16.
Clin Radiol ; 68(7): 716-20, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23537579

RESUMEN

AIM: To investigate the accuracy of colour Doppler sonography as compared to phlebography in patients with Klippel-Trénaunay syndrome (KTS). MATERIALS AND METHODS: From September 2004 to May 2012, 59 consecutive patients seen in Shandong medical imaging research institute with a clinical suggestion of KTS were included. Thirty-four were female and 25 were male, with a mean age of 28.4 years. Colour Doppler sonography was used to assess the lower limb veins. The main sonographic criteria for a positive diagnosis were visualization of the lateral vein or sciatic vein, capillary haemangioma, and abnormality of the deep veins. These data were compared with phlebography findings. The κ statistic was used to determine the level of agreement. The sensitivity, specificity, positive and negative predictive values, and accuracy of colour Doppler sonography as a diagnostic test were assessed. RESULTS: Colour Doppler sonography findings were positive in 21 of 59 patients with a clinical suggestion of KTS. The diagnosis was confirmed using phlebography in 22 patients. There were two false-positive results and one false-negative result by colour Doppler sonography. The κ-value was 0.892. Sensitivity, specificity, positive and negative predictive values, and accuracy for colour Doppler sonography were 95.4, 94.6, 91.3, 97.2, and 94.9%, respectively. CONCLUSION: Colour Doppler sonography is an accurate, reliable, and non-invasive investigation in the assessment of patients with suspected KTS.


Asunto(s)
Síndrome de Klippel-Trenaunay-Weber/diagnóstico por imagen , Ultrasonografía Doppler en Color/normas , Adolescente , Adulto , Niño , Preescolar , Femenino , Humanos , Lactante , Extremidad Inferior/irrigación sanguínea , Masculino , Persona de Mediana Edad , Flebografía/normas , Sensibilidad y Especificidad , Venas/fisiología , Adulto Joven
17.
Spinal Cord ; 51(3): 196-201, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23045300

RESUMEN

OBJECTIVES: To quantify spinal cord perfusion by using contrast-enhanced ultrasound (CEUS) in a porcine model with acute spinal cord injury. METHODS: Microcirculatory changes of acute spinal cord injury were shown by CEUS in a porcine model with spinal cord contusion at three selected time points, coupling with conventional ultrasound (US) and Color Doppler US (CDFI). Time-intensity curves and perfusion parameters were also obtained by autotracking contrast quantification (ACQ) software in the epicenter of contusion site, adjacent region and distant region, respectively. Neurologic and histologic examinations were used to confirm the severity of injury. RESULTS: Conventional US revealed the spinal cord was hypoechoic and homogeneous, whereas the dura mater, pia mater and cerebral aqueduct were hyperechoic. On CDFI intramedullary blood vessels were displayed as segmental and columnar. It was homogeneous on CEUS. After spinal cord contusion, the injured region on gray scale US was hyperechoic. CDFI demonstrated intramedullary blood vessels of adjacent region had increased and dilated during the observation period. On CEUS the epicenter of contusion site was hypoperfusion, whereas its adjacent region was hyperperfusion compared with the distant region. Quantitative analysis showed that peak intensity decreased in epicenters of contusion but increased in adjacent regions significantly at all time points (P<0.05). Evaluation of neurological function for post-contusion demonstrated significantly deterioration in comparison before injury (P<0.05). CONCLUSIONS: CEUS is a practical technique that provides overall views for evaluating microcirculatory pattern in spinal cord injury. Quantitative analysis shows the efficacy in assessment of perfusion changes after spinal cord injury.


Asunto(s)
Medios de Contraste , Microcirculación/fisiología , Traumatismos de la Médula Espinal/diagnóstico por imagen , Médula Espinal/irrigación sanguínea , Médula Espinal/diagnóstico por imagen , Ultrasonografía Doppler en Color/normas , Enfermedad Aguda , Animales , Modelos Animales de Enfermedad , Femenino , Porcinos , Ultrasonografía Doppler en Color/métodos
18.
Rheumatology (Oxford) ; 51(11): 2034-8, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22847682

RESUMEN

OBJECTIVE: To evaluate the reliability and agreement of semi-quantitative scoring (SQS) and quantitative scoring (QS) systems. To compare the two types of scoring system and investigate the construct validity for both scoring systems. METHODS: A total of 46 RA patients (median disease duration of 6.5 years) were enrolled in the study. They were investigated with colour Doppler ultrasound using the central position of the wrist. Disease activity score based on 28 joints (DAS-28) was determined for all patients using CRP. Two participants trained in the SQS system and two in the QS system evaluated the 46 anonymized images. All images were scored twice by each of the two assessors in order to assess both intra- and inter-reader reliability. RESULTS: The reliability for the two systems were 0.964 for the QS, and 0.817 for the SQS, with a comparable inter-reader agreement for both scoring systems; 95% limits of agreement for the QS being between -7.7% and +6.7% on the colour fraction scale (0-100%), whereas SQS was between -0.8 and +0.8 on the ordinal scale from 0 to 3. There was a direct but non-linear relationship between the two modalities (Spearman's r = 0.73) and critical conceptual issues in the agreement between the scoring systems were revealed. The construct validity was poor for both systems with only a weak correlation to CRP. CONCLUSION: High reliability and good agreement of both scoring systems were found when applied to the same patient cohort. Different scoring systems appear to be highly correlated.


Asunto(s)
Artritis Reumatoide/diagnóstico por imagen , Articulaciones del Carpo/diagnóstico por imagen , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Ultrasonografía Doppler en Color/normas
19.
J Vasc Surg ; 55(2): 437-45, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22178437

RESUMEN

OBJECTIVE: This prospective multicenter investigation was conducted to define the repeatability of duplex-based identification of venous reflux and the relative effect of key parameters on the reproducibility of the test. METHODS: Repeatability was studied by having the same technologist perform duplicate tests, at the same time of the day, using the same reflux-provoking maneuver and with the patient in the same position. Reproducibility was examined by having two different technologists perform the test at the same time of the day, using the same reflux-provoking maneuver and with the patient in the same position. Facilitated reproducibility was studied by having two different technologists examine the same patients immediately after an educational intervention. Limits of agreement between two duplex scans were studied by changing three elements of the test: time of the day (morning vs afternoon), patient's position (standing vs supine), and reflux initiation (manual vs automatic compression-decompression). RESULTS: The study enrolled 17 healthy volunteers and 57 patients with primary chronic venous disease. Repeatability of reflux time measurements in deep veins did not significantly differ with the time of day, the patient's position, or the reflux-provoking maneuver. Reflux measurements in the superficial veins were more repeatable (P < .05) when performed in the morning with the patient standing. The agreement between the clinical interpretations significantly depended on a selected cut point (Spearman's ρ, -0.4; P < .01). Interpretations agreed in 93.4% of the replicated measurements when a 0.5-second cut point was selected. The training intervention improved the frequency of agreement to 94.4% (κ = 0.9). Alternations of the time of the duplex scan, the patient's position, and the reflux-provoking maneuver significantly decreased reliability. CONCLUSIONS: This study provides evidence to develop a new standard for duplex ultrasound detection of venous reflux. Reports should include information on the time of the test, the patient's position, and the provoking maneuver used. Adopting a uniform cut point of 0.5 second for pathologic reflux can significantly improve the reliability of reflux detection. Implementation of a standard protocol should elevate the minimal standard for agreement between repeated tests from the current 70% to at least 80% and with more rigid standardization, to 90%.


Asunto(s)
Ultrasonografía Doppler en Color , Ultrasonografía Doppler de Pulso , Venas/diagnóstico por imagen , Insuficiencia Venosa/diagnóstico por imagen , Adulto , Anciano , Estudios de Casos y Controles , Distribución de Chi-Cuadrado , Enfermedad Crónica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Variaciones Dependientes del Observador , Posicionamiento del Paciente , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Factores de Tiempo , Ultrasonografía Doppler en Color/normas , Ultrasonografía Doppler de Pulso/normas , Estados Unidos , Venas/fisiopatología , Insuficiencia Venosa/fisiopatología
20.
Acta Ophthalmol ; 100(2): 196-202, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33629492

RESUMEN

PURPOSE: Distinguishing posterior persistent fetal vasculature (PFV) from retinal detachment (RD) may be very challenging clinically and ultrasonographically, as they share common morphological features. However, it is crucial, considering their substantially distinct management and treatment. We aimed to assess the relevance of quantitative colour Doppler flow imaging to distinguish PFV from RD in children. METHODS: This retrospective bi-centre study included 66 children (30 females and 36 males, mean age: 244 ± 257 days) with a clinically suspected diagnosis of RD or posterior PFV. All children underwent systematic and standardized conventional ultrasonography and colour Doppler flow imaging under general anaesthesia with a qualitative and quantitative analysis of the retrolental tissue's vascularization. Peak systolic velocity, end-diastolic velocity and resistive index were recorded for analysis. Whenever available, surgical findings were deemed gold standard for diagnosis. A Mann-Whitney U-test was used to compare quantitative colour Doppler flow imaging data. RESULTS: Peak systolic velocity and end-diastolic velocity were significantly lower in children with PFV versus RD: 2.7 (IQR: 0.5) versus 5.1 (IQR: 2.8), p < 0.001, and 0.0 (IQR: 0.0) versus 2.0 (IQR: 1.2), p < 0.001, respectively. Resistive index was significantly higher in children with PFV versus RD: 1 (IQR: 0) versus 0.6 (IQR: 0.1), p < 0.001. Area under curves (AUCs) were of 0.94, 0.99 and 1, respectively. No differences between PFV and RD were observed on structural ultrasound or qualitative analysis of colour Doppler. CONCLUSION: Quantitative colour Doppler flow imaging has an excellent accuracy in distinguishing PFV from RD in children. It may help to improve management and treatment.


Asunto(s)
Vítreo Primario Hiperplásico Persistente/diagnóstico por imagen , Desprendimiento de Retina/diagnóstico por imagen , Ultrasonografía Doppler en Color/normas , Velocidad del Flujo Sanguíneo , Diagnóstico Diferencial , Femenino , Humanos , Lactante , Masculino , Vítreo Primario Hiperplásico Persistente/patología , Curva ROC , Desprendimiento de Retina/patología , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA