Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Más filtros

Medicinas Complementárias
Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Brain Stimul ; 14(6): 1419-1430, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34517143

RESUMEN

BACKGROUND: Transcutaneous auricular Vagus Nerve Stimulation (taVNS) applies low-intensity electrical current to the ear with the intention of activating the auricular branch of the Vagus nerve. The sensitivity and selectivity of stimulation applied to the ear depends on current flow pattern produced by a given electrode montage (size and placement). OBJECTIVE: We compare different electrodes designs for taVNS considering both the predicted peak electric fields (sensitivity) and their spatial distribution (selectivity). METHODS: Based on optimized high-resolution (0.47 mm) T1 and T2 weighted MRI, we developed an anatomical model of the left ear and the surrounding head tissues including brain, CSF/meninges, skull, muscle, blood vessels, fat, cartilage, and skin. The ear was further segmented into 6 regions of interest (ROI) based on various nerve densities: cavum concha, cymba concha, crus of helix, tragus, antitragus, and earlobe. A range of taVNS electrode montages were reproduced spanning varied electrodes sizes and placements over the tragus, cymba concha, earlobe, cavum concha, and crus of helix. Electric field across the ear (from superficial skin to cartilage) for each montage at 1 mA or 2 mA taVNS, assuming an activation threshold of 6.15 V/m, 12.3 V/m or 24.6 V/m was predicted using a Finite element method (FEM). Finally, considering every ROI, we calculated the sensitivity and selectivity of each montage. RESULTS: Current flow patterns through the ear were highly specific to the electrode montage. Electric field was maximal at the ear regions directly under the electrodes, and for a given total current, increases with decreasing electrode size. Depending on the applied current and nerves threshold, activation may also occur in the regions between multiple anterior surface electrodes. Each considered montage was selective for one or two regions of interest. For example, electrodes across the tragus restricted significant electric field to the tragus. Stimulation across the earlobe restricted significant electric field to the earlobe and the antitragus. Because of this relative selectivity, use of control ear montages in experimental studies, support testing of targeting. Relative targeting was robust across assumptions of activation threshold and tissue properties. DISCUSSION: Computational models provide additional insight on how details in electrode shape and placement impact sensitivity (how much current is needed) and selectivity (spatial distribution), thereby supporting analysis of existing approaches and optimization of new devices. Our result suggest taVNS current patterns and relative target are robust across individuals, though (variance in) axon morphology was not represented.


Asunto(s)
Estimulación Eléctrica Transcutánea del Nervio , Estimulación del Nervio Vago , Simulación por Computador , Oído Externo , Humanos , Estimulación Eléctrica Transcutánea del Nervio/métodos , Nervio Vago/fisiología , Estimulación del Nervio Vago/métodos
2.
Brain Stimul ; 13(3): 717-750, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32289703

RESUMEN

The cranial nerves are the pathways through which environmental information (sensation) is directly communicated to the brain, leading to perception, and giving rise to higher cognition. Because cranial nerves determine and modulate brain function, invasive and non-invasive cranial nerve electrical stimulation methods have applications in the clinical, behavioral, and cognitive domains. Among other neuromodulation approaches such as peripheral, transcranial and deep brain stimulation, cranial nerve stimulation is unique in allowing axon pathway-specific engagement of brain circuits, including thalamo-cortical networks. In this review we amalgamate relevant knowledge of 1) cranial nerve anatomy and biophysics; 2) evidence of the modulatory effects of cranial nerves on cognition; 3) clinical and behavioral outcomes of cranial nerve stimulation; and 4) biomarkers of nerve target engagement including physiology, electroencephalography, neuroimaging, and behavioral metrics. Existing non-invasive stimulation methods cannot feasibly activate the axons of only individual cranial nerves. Even with invasive stimulation methods, selective targeting of one nerve fiber type requires nuance since each nerve is composed of functionally distinct axon-types that differentially branch and can anastomose onto other nerves. None-the-less, precisely controlling stimulation parameters can aid in affecting distinct sets of axons, thus supporting specific actions on cognition and behavior. To this end, a rubric for reproducible dose-response stimulation parameters is defined here. Given that afferent cranial nerve axons project directly to the brain, targeting structures (e.g. thalamus, cortex) that are critical nodes in higher order brain networks, potent effects on cognition are plausible. We propose an intervention design framework based on driving cranial nerve pathways in targeted brain circuits, which are in turn linked to specific higher cognitive processes. State-of-the-art current flow models that are used to explain and design cranial-nerve-activating stimulation technology require multi-scale detail that includes: gross anatomy; skull foramina and superficial tissue layers; and precise nerve morphology. Detailed simulations also predict that some non-invasive electrical or magnetic stimulation approaches that do not intend to modulate cranial nerves per se, such as transcranial direct current stimulation (tDCS) and transcranial magnetic stimulation (TMS), may also modulate activity of specific cranial nerves. Much prior cranial nerve stimulation work was conceptually limited to the production of sensory perception, with individual titration of intensity based on the level of perception and tolerability. However, disregarding sensory emulation allows consideration of temporal stimulation patterns (axon recruitment) that modulate the tone of cortical networks independent of sensory cortices, without necessarily titrating perception. For example, leveraging the role of the thalamus as a gatekeeper for information to the cerebral cortex, preventing or enhancing the passage of specific information depending on the behavioral state. We show that properly parameterized computational models at multiple scales are needed to rationally optimize neuromodulation that target sets of cranial nerves, determining which and how specific brain circuitries are modulated, which can in turn influence cognition in a designed manner.


Asunto(s)
Encéfalo/fisiología , Enfermedades del Sistema Nervioso Central/terapia , Cognición/fisiología , Nervios Craneales/fisiología , Terapia por Estimulación Eléctrica/métodos , Encéfalo/diagnóstico por imagen , Encéfalo/fisiopatología , Enfermedades del Sistema Nervioso Central/diagnóstico por imagen , Enfermedades del Sistema Nervioso Central/fisiopatología , Nervios Craneales/diagnóstico por imagen , Nervios Craneales/fisiopatología , Electroencefalografía/métodos , Humanos , Neuroimagen/métodos , Estimulación Transcraneal de Corriente Directa/métodos , Estimulación Magnética Transcraneal/métodos
3.
Neurol Sci ; 41(7): 1781-1789, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32040791

RESUMEN

BACKGROUND: During transcranial direct current stimulation (tDCS), the amount and distribution of current that reaches the brain depends on individual anatomy. Many progressive neurodegenerative diseases are associated with cortical atrophy, but the importance of individual brain atrophy during tDCS in patients with progressive atrophy, including primary progressive aphasia (PPA), remains unclear. OBJECTIVE: In the present study, we addressed the question whether brain anatomy in patients with distinct cortical atrophy patterns would impact brain current intensity and distribution during tDCS over the left IFG. METHOD: We developed state-of-the-art, gyri-precise models of three subjects, each representing a variant of primary progressive aphasia: non-fluent variant PPA (nfvPPA), semantic variant PPA (svPPA), and logopenic variant PPA (lvPPA). We considered two exemplary montages over the left inferior frontal gyrus (IFG): a conventional pad montage (anode over F7, cathode over the right cheek) and a 4 × 1 high-definition tDCS montage. We further considered whether local anatomical features, specifically distance of the cortex to skull, can directly predict local electric field intensity. RESULTS: We found that the differences in brain current flow across the three PPA variants fall within the distribution of anatomically typical adults. While clustering of electric fields was often around individual gyri or sulci, the minimal distance from the gyri/sulci to skull was not correlated with electric field intensity. CONCLUSION: Limited to the conditions and assumptions considered here, this argues against a specific need to adjust the tDCS montage for these patients any more than might be considered useful in anatomically typical adults. Therefore, local atrophy does not, in isolation, reliably predict local electric field. Rather, our results are consistent with holistic head anatomy influencing brain current flow, with tDCS producing diffuse and individualized brain current flow patterns and HD-tDCS producing targeted brain current flow across individuals.


Asunto(s)
Afasia Progresiva Primaria , Enfermedades Neurodegenerativas , Estimulación Transcraneal de Corriente Directa , Adulto , Afasia Progresiva Primaria/diagnóstico por imagen , Afasia Progresiva Primaria/terapia , Atrofia , Encéfalo/diagnóstico por imagen , Humanos
4.
Sci Rep ; 10(1): 946, 2020 01 22.
Artículo en Inglés | MEDLINE | ID: mdl-31969588

RESUMEN

Problem-solving is essential for advances in cultural, social, and scientific knowledge. It is also one of the most challenging cognitive processes to facilitate. Some problem-solving is deliberate, but frequently people solve problems with a sudden insight, also known as a Eureka or "Aha!" moment. The advantage of solving problems via insight is that these solutions are more accurate, relying on a unique pattern of neural activity, compared to deliberative strategies. The right Anterior Temporal Lobe (rATL), putatively involved in semantic integration, is distinctively activated when people experience an insight. The rATL may contribute to the recognition of distant semantic relations that support insight solutions, although fMRI and EEG evidence for its involvement is, by nature, correlational. In this study, we investigate if focal sub-threshold neuromodulation to the rATL facilitates insight problem-solving. In three different groups, using a within- and between-subjects design, we tested the causal role of this brain region in problem-solving, by applying High Definition Transcranial Direct Current Stimulation to the rATL (active and sham condition) or the left frontopolar region while participants attempted to solve Compound Remote Associates problems before, during and after stimulation. Participants solved a higher percentage of problems, overall, and specifically by insight when they received rATL stimulation, compared to pre-stimulation, and compared to sham and left frontopolar stimulation. These results confirm the crucial role played by the rATL in insight problem-solving.


Asunto(s)
Solución de Problemas/fisiología , Lóbulo Temporal/fisiología , Estimulación Transcraneal de Corriente Directa , Estimulación Eléctrica Transcutánea del Nervio/métodos , Femenino , Humanos , Masculino
5.
J Vis Exp ; (143)2019 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-30663712

RESUMEN

Non-invasive vagus nerve stimulation (VNS) may be administered via a novel, emerging neuromodulatory technique known as transcutaneous auricular vagus nerve stimulation (taVNS). Unlike cervically-implanted VNS, taVNS is an inexpensive and non-surgical method used to modulate the vagus system. taVNS is appealing as it allows for rapid translation of basic VNS research and serves as a safe, inexpensive, and portable neurostimulation system for the future treatment of central and peripheral disease. The background and rationale for taVNS is described, along with electrical and parametric considerations, proper ear targeting and attachment of stimulation electrodes, individual dosing via determination of perception threshold (PT), and safe administration of taVNS.


Asunto(s)
Laboratorios , Estimulación Eléctrica Transcutánea del Nervio/métodos , Estimulación del Nervio Vago/métodos , Adulto , Electricidad , Femenino , Humanos , Masculino , Percepción , Interfaz Usuario-Computador , Nervio Vago/fisiología
6.
Int J Obes (Lond) ; 43(10): 2119-2124, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-30538282

RESUMEN

Human neuroimaging studies have consistently reported changes in cerebellar function and integrity in association with obesity. To date, however, the nature of this link has not been studied directly. Emerging evidence suggests a role for the cerebellum in higher cognitive functions through reciprocal connections with the prefrontal cortex. The purpose of this exploratory study was to examine appetite changes associated with noninvasive prefronto-cerebellar neuromodulation in obesity. Totally, 12 subjects with class I obesity (mean body mass index 32.9 kg/m2) underwent a randomized, single-blinded, sham-controlled, crossover study, during which they received transcranial direct current stimulation ((tDCS); active/sham) aimed at simultaneously enhancing the activity of the prefrontal cortex and decreasing the activity of the cerebellum. Changes in appetite (state and food-cue-triggered) and performance in a food-modified working memory task were evaluated. We found that active tDCS caused an increase in hunger and desire to eat following food-cue exposure. In line with these data, subjects also tended to make more errors during the working memory task. No changes in basic motor performance occurred. This study represents the first demonstration that prefronto-cerebellar neuromodulation can influence appetite in individuals with obesity. While preliminary, our findings support a potential role for prefronto-cerebellar pathways in the behavioral manifestations of obesity.


Asunto(s)
Apetito/fisiología , Cerebelo , Conducta Alimentaria/fisiología , Obesidad/fisiopatología , Obesidad/terapia , Corteza Prefrontal , Estimulación Transcraneal de Corriente Directa , Adulto , Estudios Cruzados , Femenino , Humanos , Masculino , Neurorretroalimentación , Neuroimagen , Proyectos Piloto , España/epidemiología , Resultado del Tratamiento
7.
Soc Neurosci ; 14(1): 10-25, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-29067880

RESUMEN

Positive emotional perceptions and healthy emotional intelligence (EI) are important for social functioning. In this study, we investigated whether loving kindness meditation (LKM) combined with anodal transcranial direct current stimulation (tDCS) would facilitate improvements in EI and changes in affective experience of visual stimuli. LKM has been shown to increase positive emotional experiences and we hypothesized that tDCS could enhance these effects. Eighty-seven undergraduates were randomly assigned to 30 minutes of LKM or a relaxation control recording with anodal tDCS applied to the left dorsolateral prefrontal cortex (left dlPFC) or right temporoparietal junction (right TPJ) at 0.1 or 2.0 milliamps. The primary outcomes were self-reported affect ratings of images from the International Affective Picture System and EI as measured by the Mayer, Salovey and Caruso Emotional Intelligence Test. Results indicated no effects of training on EI, and no main effects of LKM, electrode placement, or tDCS current strength on affect ratings. There was a significant interaction of electrode placement by meditation condition (p = 0.001), such that those assigned to LKM and right TPJ tDCS, regardless of current strength, rated neutral and positive images more positively after training. Results suggest that LKM may enhance positive affective experience.


Asunto(s)
Inteligencia Emocional/fisiología , Meditación , Estimulación Transcraneal de Corriente Directa , Adolescente , Adulto , Femenino , Humanos , Masculino , Proyectos Piloto , Adulto Joven
9.
Brain Stimul ; 11(5): 1151-1160, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29784588

RESUMEN

BACKGROUND: The bursting pattern of thalamocortical (TC) pathway dampens nociception. Whether brain stimulation mimicking endogenous patterns can engage similar sensory gating processes in the cortex and reduce nociceptive behaviors remains uninvestigated. OBJECTIVE: We investigated the role of cortical parvalbumin expressing (PV) interneurons within the TC circuit in gating nociception and their selective response to TC burst patterns. We then tested if transcranial magnetic stimulation (TMS) patterned on endogenous nociceptive TC bursting modulate nociceptive behaviors. METHODS: The switching of TC neurons between tonic (single spike) and burst (high frequency spikes) firing modes may be a critical component in modulating nociceptive signals. Deep brain electrical stimulation of TC neurons and immunohistochemistry were used to examine the differential influence of each firing mode on cortical PV interneuron activity. Optogenetic stimulation of cortical PV interneurons assessed a direct role in nociceptive modulation. A new TMS protocol mimicking thalamic burst firing patterns, contrasted with conventional continuous and intermittent theta burst protocols, tested if TMS patterned on endogenous TC activity reduces nociceptive behaviors in mice. RESULTS: Immunohistochemical evidence confirmed that burst, but not tonic, deep brain stimulation of TC neurons increased the activity of PV interneurons in the cortex. Both optogenetic activation of PV interneurons and TMS protocol mimicking thalamic burst reduced nociceptive behaviors. CONCLUSIONS: Our findings suggest that burst firing of TC neurons recruits PV interneurons in the cortex to reduce nociceptive behaviors and that neuromodulation mimicking thalamic burst firing may be useful for modulating nociception.


Asunto(s)
Interneuronas/fisiología , Nocicepción , Tálamo/fisiología , Animales , Masculino , Ratones , Parvalbúminas/genética , Parvalbúminas/metabolismo , Filtrado Sensorial , Tálamo/citología , Estimulación Magnética Transcraneal
10.
Brain Stimul ; 11(4): 727-733, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29576498

RESUMEN

BACKGROUND: Transcranial direct current stimulation (tDCS) is a promising brain modulation technique for several disease conditions. With this technique, some portion of the current penetrates through the scalp to the cortex and modulates cortical excitability, but a recent human cadaver study questions the amount. This insufficient intracerebral penetration of currents may partially explain the inconsistent and mixed results in tDCS studies to date. Experimental validation of a transcranial alternating current stimulation-generated electric field (EF) in vivo has been performed on the cortical (using electrocorticography, ECoG, electrodes), subcortical (using stereo electroencephalography, SEEG, electrodes) and deeper thalamic/subthalamic levels (using DBS electrodes). However, tDCS-generated EF measurements have never been attempted. OBJECTIVE: We aimed to demonstrate that tDCS generates biologically relevant EF as deep as the subthalamic level in vivo. METHODS: Patients with movement disorders who have implanted deep brain stimulation (DBS) electrodes serve as a natural experimental model for thalamic/subthalamic recordings of tDCS-generated EF. We measured voltage changes from DBS electrodes and body resistance from tDCS electrodes in three subjects while applying direct current to the scalp at 2 mA and 4 mA over two tDCS montages. RESULTS: Voltage changes at the level of deep nuclei changed proportionally with the level of applied current and varied with different tDCS montages. CONCLUSIONS: Our findings suggest that scalp-applied tDCS generates biologically relevant EF. Incorporation of these experimental results may improve finite element analysis (FEA)-based models.


Asunto(s)
Ondas Encefálicas , Campos Electromagnéticos , Tálamo/fisiología , Estimulación Transcraneal de Corriente Directa , Adulto , Femenino , Humanos , Masculino
11.
Brain Stimul ; 11(1): 134-157, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29122535

RESUMEN

We present device standards for low-power non-invasive electrical brain stimulation devices classified as limited output transcranial electrical stimulation (tES). Emerging applications of limited output tES to modulate brain function span techniques to stimulate brain or nerve structures, including transcranial direct current stimulation (tDCS), transcranial alternating current stimulation (tACS), and transcranial pulsed current stimulation (tPCS), have engendered discussion on how access to technology should be regulated. In regards to legal regulations and manufacturing standards for comparable technologies, a comprehensive framework already exists, including quality systems (QS), risk management, and (inter)national electrotechnical standards (IEC). In Part 1, relevant statutes are described for medical and wellness application. While agencies overseeing medical devices have broad jurisdiction, enforcement typically focuses on those devices with medical claims or posing significant risk. Consumer protections regarding responsible marketing and manufacture apply regardless. In Part 2 of this paper, we classify the electrical output performance of devices cleared by the United States Food and Drug Administration (FDA) including over-the-counter (OTC) and prescription electrostimulation devices, devices available for therapeutic or cosmetic purposes, and devices indicated for stimulation of the body or head. Examples include iontophoresis devices, powered muscle stimulators (PMS), cranial electrotherapy stimulation (CES), and transcutaneous electrical nerve stimulation (TENS) devices. Spanning over 13 FDA product codes, more than 1200 electrical stimulators have been cleared for marketing since 1977. The output characteristics of conventional tDCS, tACS, and tPCS techniques are well below those of most FDA cleared devices, including devices that are available OTC and those intended for stimulation on the head. This engineering analysis demonstrates that with regard to output performance and standing regulation, the availability of tDCS, tACS, or tPCS to the public would not introduce risk, provided such devices are responsibly manufactured and legally marketed. In Part 3, we develop voluntary manufacturer guidance for limited output tES that is aligned with current regulatory standards. Based on established medical engineering and scientific principles, we outline a robust and transparent technical framework for ensuring limited output tES devices are designed to minimize risks, while also supporting access and innovation. Alongside applicable medical and government activities, this voluntary industry standard (LOTES-2017) further serves an important role in supporting informed decisions by the public.


Asunto(s)
Estimulación Transcraneal de Corriente Directa/instrumentación , Estimulación Transcraneal de Corriente Directa/normas , Humanos , Gestión de Riesgos , Estados Unidos , United States Food and Drug Administration/legislación & jurisprudencia
12.
Dose Response ; 15(1): 1559325816685467, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28210202

RESUMEN

The US Air Force Office of Scientific Research convened a meeting of researchers in the fields of neuroscience, psychology, engineering, and medicine to discuss most pressing issues facing ongoing research in the field of transcranial direct current stimulation (tDCS) and related techniques. In this study, we present opinions prepared by participants of the meeting, focusing on the most promising areas of research, immediate and future goals for the field, and the potential for hormesis theory to inform tDCS research. Scientific, medical, and ethical considerations support the ongoing testing of tDCS in healthy and clinical populations, provided best protocols are used to maximize safety. Notwithstanding the need for ongoing research, promising applications include enhancing vigilance/attention in healthy volunteers, which can accelerate training and support learning. Commonly, tDCS is used as an adjunct to training/rehabilitation tasks with the goal of leftward shift in the learning/treatment effect curves. Although trials are encouraging, elucidating the basic mechanisms of tDCS will accelerate validation and adoption. To this end, biomarkers (eg, clinical neuroimaging and findings from animal models) can support hypotheses linking neurobiological mechanisms and behavioral effects. Dosage can be optimized using computational models of current flow and understanding dose-response. Both biomarkers and dosimetry should guide individualized interventions with the goal of reducing variability. Insights from other applied energy domains, including ionizing radiation, transcranial magnetic stimulation, and low-level laser (light) therapy, can be prudently leveraged.

13.
Prog Brain Res ; 222: 1-23, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26541374

RESUMEN

Computational neurostimulation aims to develop mathematical constructs that link the application of neuromodulation with changes in behavior and cognition. This process is critical but daunting for technical challenges and scientific unknowns. The overarching goal of this review is to address how this complex task can be made tractable. We describe a framework of sequential modeling steps to achieve this: (1) current flow models, (2) cell polarization models, (3) network and information processing models, and (4) models of the neuroscientific correlates of behavior. Each step is explained with a specific emphasis on the assumptions underpinning underlying sequential implementation. We explain the further implementation of the quasi-uniform assumption to overcome technical limitations and unknowns. We specifically focus on examples in electrical stimulation, such as transcranial direct current stimulation. Our approach and conclusions are broadly applied to immediate and ongoing efforts to deploy computational neurostimulation.


Asunto(s)
Encéfalo/fisiología , Simulación por Computador , Terapia por Estimulación Eléctrica/métodos , Terapia Asistida por Computador/métodos , Animales , Humanos
14.
Expert Rev Med Devices ; 12(4): 381-91, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25982412

RESUMEN

BACKGROUND: Neuromodulation techniques for obsessive-compulsive disorder (OCD) treatment have expanded with greater understanding of the brain circuits involved. Transcranial direct current stimulation (tDCS) might be a potential new treatment for OCD, although the optimal montage is unclear. OBJECTIVE: To perform a systematic review on meta-analyses of repetitive transcranianal magnetic stimulation (rTMS) and deep brain stimulation (DBS) trials for OCD, aiming to identify brain stimulation targets for future tDCS trials and to support the empirical evidence with computer head modeling analysis. METHODS: Systematic reviews of rTMS and DBS trials on OCD in Pubmed/MEDLINE were searched. For the tDCS computational analysis, we employed head models with the goal of optimally targeting current delivery to structures of interest. RESULTS: Only three references matched our eligibility criteria. We simulated four different electrodes montages and analyzed current direction and intensity. CONCLUSION: Although DBS, rTMS and tDCS are not directly comparable and our theoretical model, based on DBS and rTMS targets, needs empirical validation, we found that the tDCS montage with the cathode over the pre-supplementary motor area and extra-cephalic anode seems to activate most of the areas related to OCD.


Asunto(s)
Magnetoterapia/instrumentación , Magnetoterapia/métodos , Modelos Biológicos , Trastorno Obsesivo Compulsivo/terapia , Estimulación Transcraneal de Corriente Directa/instrumentación , Estimulación Transcraneal de Corriente Directa/métodos , Electrodos , Femenino , Humanos , MEDLINE , Masculino , Corteza Motora/fisiopatología , Trastorno Obsesivo Compulsivo/fisiopatología
15.
Arthritis Rheumatol ; 67(2): 576-81, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25371383

RESUMEN

OBJECTIVE: Transcranial direct current stimulation (tDCS) has been shown to improve pain symptoms in fibromyalgia (FM), a central pain syndrome whose underlying mechanisms are not well understood. This study was undertaken to explore the neurochemical action of tDCS in the brain of patients with FM, using proton magnetic resonance spectroscopy (1H-MRS). METHODS: Twelve patients with FM underwent sham tDCS over the left motor cortex (anode placement) and contralateral supraorbital cortex (cathode placement) for 5 consecutive days, followed by a 7-day washout period and then active tDCS for 5 consecutive days. Clinical pain assessment and 1H-MRS testing were performed at baseline, the week following the sham tDCS trial, and the week following the active tDCS trial. RESULTS: Clinical pain scores decreased significantly between the baseline and active tDCS time points (P = 0.04). Levels of glutamate + glutamine (Glx) in the anterior cingulate were significantly lower at the post­active tDCS assessment compared with the post­sham tDCS assessment (P = 0.013), and the decrease in Glx levels in the thalami between these time points approached significance (P = 0.056). From baseline to the post­sham tDCS assessment, levels of N-acetylaspartate (NAA) in the posterior insula increased significantly (P = 0.015). There was a trend toward increased levels of γ-aminobutyric acid (GABA) in the anterior insula after active tDCS, compared with baseline (P = 0.064). Baseline anterior cingulate Glx levels correlated significantly with changes in pain score, both for the time period from baseline to sham tDCS (ß1 = 1.31, P < 0.001) and for the time period from baseline to active tDCS (ß1= 1.87, P < 0.001). CONCLUSION: The present findings suggest that GABA, Glx, and NAA play an important role in the pathophysiology of FM and its modulation by tDCS.


Asunto(s)
Encéfalo/metabolismo , Fibromialgia/metabolismo , Fibromialgia/terapia , Corteza Motora/metabolismo , Estimulación Transcraneal de Corriente Directa , Adulto , Ácido Aspártico/análogos & derivados , Ácido Aspártico/metabolismo , Encéfalo/patología , Femenino , Fibromialgia/patología , Ácido Glutámico/metabolismo , Glutamina/metabolismo , Humanos , Estudios Longitudinales , Persona de Mediana Edad , Corteza Motora/patología , Dimensión del Dolor , Espectroscopía de Protones por Resonancia Magnética , Resultado del Tratamiento , Ácido gamma-Aminobutírico/metabolismo
16.
Neuroimage ; 85 Pt 3: 1003-13, 2014 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-23727533

RESUMEN

BACKGROUND: Chronic neuropathic pain is one of the most common and disabling symptoms in individuals with spinal cord injury (SCI). Over two-thirds of subjects with SCI suffer from chronic pain influencing quality of life, rehabilitation, and recovery. Given the refractoriness of chronic pain to most pharmacological treatments, the majority of individuals with SCI report worsening of this condition over time. Moreover, only 4-6% of patients in this cohort report improvement. Novel treatments targeting mechanisms associated with pain-maladaptive plasticity, such as electromagnetic neural stimulation, may be desirable to improve outcomes. To date, few, small clinical trials have assessed the effects of invasive and noninvasive nervous system stimulation on pain after SCI. OBJECTIVE: We aimed to review initial efficacy, safety and potential predictors of response by assessing the effects of neural stimulation techniques to treat SCI pain. SEARCH STRATEGY: A literature search was performed using the PubMed database including studies using the following targeted stimulation strategies: transcranial Direct Current Stimulation (tDCS), High Definition tDCS (HD-tDCS), repetitive Transcranial Magnetical Stimulation (rTMS), Cranial Electrotherapy Stimulation (CES), Transcutaneous Electrical Nerve Stimulation (TENS), Spinal Cord Stimulation (SCS) and Motor Cortex Stimulation (MCS), published prior to June of 2012. We included studies from 1998 to 2012. RESULTS: Eight clinical trials and one naturalistic observational study (nine studies in total) met the inclusion criteria. Among the clinical trials, three studies assessed the effects of tDCS, two of CES, two of rTMS and one of TENS. The naturalistic study investigated the analgesic effects of SCS. No clinical trials for epidural motor cortex stimulation (MCS) or HD-tDCS were found. Parameters of stimulation and also clinical characteristics varied significantly across studies. Three out of eight studies showed larger effects sizes (0.73, 0.88 and 1.86 respectively) for pain reduction. Classical neuropathic pain symptoms such as dysesthesia (defined as an unpleasant burning sensation in response to touch), allodynia (pain due to a non-painful stimulus), pain in paroxysms, location of SCI in thoracic and lumbar segments and pain in the lower limbs seem to be associated with a positive response to neural stimulation. No significant adverse effects were reported in these studies. CONCLUSIONS: Chronic pain in SCI is disabling and resistant to common pharmacologic approaches. Electrical and magnetic neural stimulation techniques have been developed to offer a potential tool in the management of these patients. Although some of these techniques are associated with large standardized mean differences to reduce pain, we found an important variability in these results across studies. There is a clear need for the development of methods to decrease treatment variability and increase response to neural stimulation for pain treatment. We discuss potential methods such as neuroimaging or EEG-guided neural stimulation and the development of better surrogate markers of response such as TMS-indexed cortical plasticity.


Asunto(s)
Dolor Crónico/terapia , Terapia por Estimulación Eléctrica/métodos , Neuralgia/terapia , Traumatismos de la Médula Espinal/complicaciones , Estimulación Magnética Transcraneal/métodos , Dolor Crónico/etiología , Humanos , Neuralgia/etiología , Traumatismos de la Médula Espinal/terapia
17.
PLoS One ; 8(9): e76112, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24086698

RESUMEN

Transcranial direct current stimulation (tDCS) is being widely investigated in adults as a therapeutic modality for brain disorders involving abnormal cortical excitability or disordered network activity. Interest is also growing in studying tDCS in children. Limited empirical studies in children suggest that tDCS is well tolerated and may have a similar safety profile as in adults. However, in electrotherapy as in pharmacotherapy, dose selection in children requires special attention, and simple extrapolation from adult studies may be inadequate. Critical aspects of dose adjustment include 1) differences in neurophysiology and disease, and 2) variation in brain electric fields for a specified dose due to gross anatomical differences between children and adults. In this study, we used high-resolution MRI derived finite element modeling simulations of two healthy children, ages 8 years and 12 years, and three healthy adults with varying head size to compare differences in electric field intensity and distribution. Multiple conventional and high-definition tDCS montages were tested. Our results suggest that on average, children will be exposed to higher peak electrical fields for a given applied current intensity than adults, but there is likely to be overlap between adults with smaller head size and children. In addition, exposure is montage specific. Variations in peak electrical fields were seen between the two pediatric models, despite comparable head size, suggesting that the relationship between neuroanatomic factors and bioavailable current dose is not trivial. In conclusion, caution is advised in using higher tDCS doses in children until 1) further modeling studies in a larger group shed light on the range of exposure possible by applied dose and age and 2) further studies correlate bioavailable dose estimates from modeling studies with empirically tested physiologic effects, such as modulation of motor evoked potentials after stimulation.


Asunto(s)
Encéfalo/fisiología , Biología Computacional/métodos , Terapia por Estimulación Eléctrica/métodos , Modelos Neurológicos , Factores de Edad , Encéfalo/anatomía & histología , Niño , Simulación por Computador , Análisis de Elementos Finitos , Humanos , Imagen por Resonancia Magnética
18.
J Neurosci Methods ; 219(2): 297-311, 2013 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-23954780

RESUMEN

Transcranial Electrical Stimulation (tES) encompasses all methods of non-invasive current application to the brain used in research and clinical practice. We present the first comprehensive and technical review, explaining the evolution of tES in both terminology and dosage over the past 100 years of research to present day. Current transcranial Pulsed Current Stimulation (tPCS) approaches such as Cranial Electrotherapy Stimulation (CES) descended from Electrosleep (ES) through Cranial Electro-stimulation Therapy (CET), Transcerebral Electrotherapy (TCET), and NeuroElectric Therapy (NET) while others like Transcutaneous Cranial Electrical Stimulation (TCES) descended from Electroanesthesia (EA) through Limoge, and Interferential Stimulation. Prior to a contemporary resurgence in interest, variations of transcranial Direct Current Stimulation were explored intermittently, including Polarizing current, Galvanic Vestibular Stimulation (GVS), and Transcranial Micropolarization. The development of these approaches alongside Electroconvulsive Therapy (ECT) and pharmacological developments are considered. Both the roots and unique features of contemporary approaches such as transcranial Alternating Current Stimulation (tACS) and transcranial Random Noise Stimulation (tRNS) are discussed. Trends and incremental developments in electrode montage and waveform spanning decades are presented leading to the present day. Commercial devices, seminal conferences, and regulatory decisions are noted. We conclude with six rules on how increasing medical and technological sophistication may now be leveraged for broader success and adoption of tES.


Asunto(s)
Terapia por Estimulación Eléctrica/historia , Terapia por Estimulación Eléctrica/clasificación , Terapia por Estimulación Eléctrica/métodos , Historia del Siglo XX , Historia del Siglo XXI , Humanos
19.
J Vis Exp ; (77): e50309, 2013 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-23893039

RESUMEN

High-definition transcranial direct current stimulation (HD-tDCS) has recently been developed as a noninvasive brain stimulation approach that increases the accuracy of current delivery to the brain by using arrays of smaller "high-definition" electrodes, instead of the larger pad-electrodes of conventional tDCS. Targeting is achieved by energizing electrodes placed in predetermined configurations. One of these is the 4x1-ring configuration. In this approach, a center ring electrode (anode or cathode) overlying the target cortical region is surrounded by four return electrodes, which help circumscribe the area of stimulation. Delivery of 4x1-ring HD-tDCS is capable of inducing significant neurophysiological and clinical effects in both healthy subjects and patients. Furthermore, its tolerability is supported by studies using intensities as high as 2.0 milliamperes for up to twenty minutes. Even though 4x1 HD-tDCS is simple to perform, correct electrode positioning is important in order to accurately stimulate target cortical regions and exert its neuromodulatory effects. The use of electrodes and hardware that have specifically been tested for HD-tDCS is critical for safety and tolerability. Given that most published studies on 4x1 HD-tDCS have targeted the primary motor cortex (M1), particularly for pain-related outcomes, the purpose of this article is to systematically describe its use for M1 stimulation, as well as the considerations to be taken for safe and effective stimulation. However, the methods outlined here can be adapted for other HD-tDCS configurations and cortical targets.


Asunto(s)
Estimulación Eléctrica/instrumentación , Estimulación Eléctrica/métodos , Terapia por Estimulación Eléctrica/instrumentación , Terapia por Estimulación Eléctrica/métodos , Electrodos , Humanos , Corteza Motora/fisiología
20.
J Pain ; 14(4): 371-83, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23415877

RESUMEN

UNLABELLED: Fibromyalgia is a prevalent chronic pain syndrome characterized by altered pain and sensory processing in the central nervous system, which is often refractory to multiple therapeutic approaches. Given previous evidence supporting analgesic properties of noninvasive brain stimulation techniques in this condition, this study examined the effects of a novel, more focal method of transcranial direct current stimulation (tDCS), using the 4×1-ring configuration of high-definition (HD)-tDCS, on overall perceived pain in fibromyalgia patients. In this patient- and assessor-blind, sham-controlled, crossover trial, 18 patients were randomized to undergo single 20-minute sessions of anodal, cathodal, and sham HD-tDCS at 2.0 mA in a counterbalanced fashion. The center electrode was positioned over the left primary motor cortex. Pain scales and sensory testing were assessed before and after each intervention. A finite element method brain model was generated to predict electric field distribution. We found that both active stimulation conditions led to significant reduction in overall perceived pain as compared to sham. This effect occurred immediately after cathodal HD-tDCS and was evident for both anodal and cathodal HD-tDCS 30 minutes after stimulation. Furthermore, active anodal stimulation induced a significant bilateral increase in mechanical detection thresholds. These interventions proved well tolerated in our patient population. PERSPECTIVE: 4×1-ring HD-tDCS, a novel noninvasive brain stimulation technique capable of more focal and targeted stimulation, provides significant reduction in overall perceived pain in fibromyalgia patients as compared to sham stimulation, irrespective of current polarity. This technique may have other applications in research and clinical settings, which should be further explored.


Asunto(s)
Terapia por Estimulación Eléctrica/métodos , Fibromialgia/terapia , Corteza Motora/fisiología , Estudios Cruzados , Método Doble Ciego , Terapia por Estimulación Eléctrica/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA