Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Control Release ; 343: 798-812, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35134460

RESUMEN

PURPOSE: Encapsulation of cytotoxic drugs for a localized release is an effective way to increase the therapeutic window of such agents. In this article we present the localized release of doxorubicin (DOX) from phosphatidyldiglycerol (DPPG2) based thermosensitive liposomes using MR-HIFU mediated hyperthermia in a swine model. MATERIALS AND METHODS: German landrace pigs of weights between 37.5 and 53.5 kg received a 30-min infusion of DOX containing thermosensitive liposomes (50 mg DOX/m2). The pigs' biceps femoris was treated locally in two separate target areas with mild hyperthermia using magnetic resonance guided high intensity focused ultrasound, starting 10 min and 60 min after initiation of the infusion, respectively. The pharmacokinetics and biodistribution of DOX were determined and an analysis of the treatment parameters' influence was performed. RESULTS: Compared to untreated tissue, we found a 15-fold and a 7-fold increase in DOX concentration in the muscle volumes that had undergone hyperthermia starting 10 min and 60 min after the beginning of the infusion, respectively. The pharmacokinetic analysis showed a prolonged circulation time of DOX and a correlation between the AUC of extra-liposomal DOX in the bloodstream and the amount of DOX accumulated in the target tissue. CONCLUSIONS: We have demonstrated a workflow for MR-HIFU hyperthermia drug delivery that can be adapted to a clinical setting, showing that HIFU-hyperthermia is a suitable method for local drug release of DOX using DPPG2 based thermosensitive liposomes in stationary targets. Using the developed pharmacokinetic model, an optimization of the drug quantity deposited in the target via the timing of infusion and hyperthermia should be possible.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación , Hipertermia Inducida , Animales , Antibióticos Antineoplásicos , Doxorrubicina , Sistemas de Liberación de Medicamentos/métodos , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Hipertermia Inducida/métodos , Liposomas , Porcinos , Distribución Tisular
2.
Int J Hyperthermia ; 38(1): 1174-1187, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34374624

RESUMEN

PURPOSE: This article will report results from the in-vivo application of a previously published model-predictive control algorithm for MR-HIFU hyperthermia. The purpose of the investigation was to test the controller's in-vivo performance and behavior in the presence of heterogeneous perfusion. MATERIALS AND METHODS: Hyperthermia at 42°C was induced and maintained for up to 30 min in a circular section of a thermometry slice in the biceps femoris of German landrace pigs (n=5) using a commercial MR-HIFU system and a recently developed MPC algorithm. The heating power allocation was correlated with heat sink maps and contrast-enhanced MRI images. The temporal change in perfusion was estimated based on the power required to maintain hyperthermia. RESULTS: The controller performed well throughout the treatments with an absolute average tracking error of 0.27 ± 0.15 °C and an average difference of 1.25 ± 0.22 °C between T10 and T90. The MPC algorithm allocates additional heating power to sub-volumes with elevated heat sink effects, which are colocalized with blood vessels visible on contrast-enhanced MRI. The perfusion appeared to have increased by at least a factor of ∼1.86 on average. CONCLUSIONS: The MPC controller generates temperature distributions with a narrow spectrum of voxel temperatures inside the target ROI despite the presence of spatiotemporally heterogeneous perfusion due to the rapid thermometry feedback available with MR-HIFU and the flexible allocation of heating power. The visualization of spatiotemporally heterogeneous perfusion presents new research opportunities for the investigation of stimulated perfusion in hypoxic tumor regions.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación , Hipertermia Inducida , Algoritmos , Animales , Hipertermia , Imagen por Resonancia Magnética , Perfusión , Porcinos
3.
Rofo ; 191(6): 522-530, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30630200

RESUMEN

BACKGROUND: Extracorporeal high-intensity focused ultrasound (HIFU) is a promising method for the noninvasive thermal ablation of benign and malignant tissue. Current HIFU treatments are performed under ultrasound (US-HIFU) or magnetic resonance (MR-HIFU) image guidance offering integrated therapy planning, real-time control (spatial and temperature guidance) and evaluation. METHODS: This review is based on publications in peer-reviewed journals addressing thermal ablation using HIFU and includes our own clinical results as well. The technical background of HIFU is explained with an emphasis on MR-HIFU applications. A brief overview of the most commonly performed CE-approved clinical applications for MR-HIFU is given. RESULTS: Over the last decade, several HIFU-based applications have received clinical approval in various countries. In particular, MR-HIFU is now approved for the clinical treatment of uterine fibroids, palliation of bone pain, ablation of the prostate and treatment of essential tremor as a first neurological application. CONCLUSION: MR-HIFU is a patient-friendly noninvasive method for thermal ablation which has received clinical approval for several applications. Overall, clinical data demonstrate treatment efficacy, safety and cost efficiency. KEY POINTS: · HIFU is a promising technique for noninvasive thermal ablation of tissue.. · HIFU is typically performed under image guidance using either diagnostic ultrasound (US-HIFU) or MRI (MR-HIFU).. · The preferred image guidance modality depends on the application.. · MR guidance offers improved soft-tissue contrast for treatment planning, near real-time and noninvasive temperature monitoring and post-interventional therapy evaluation.. · MR-HIFU is CE-approved for treatment of uterine fibroids, alleviation of bone pain, prostate tissue ablation and treatment of essential tremor.. CITATION FORMAT: · Siedek F, Yeo S, Heijman E et al. Magnetic Resonance-Guided High-Intensity Focused Ultrasound (MR-HIFU): Technical Background and Overview of Current Clinical Applications (Part 1). Fortschr Röntgenstr 2019; 191: 522 - 530.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Enfermedades Óseas/terapia , Temblor Esencial/terapia , Femenino , Humanos , Leiomioma/terapia , Masculino , Manejo del Dolor/métodos , Hiperplasia Prostática/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA