Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.372
Filtrar
1.
Int J Cardiol ; 414: 132416, 2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39098616

RESUMEN

BACKGROUND: The impact of various imaging modalities on discordance/concordance between indexed aortic valve area (iAVA) and catheterization-derived mean transaortic pressure gradient (mPGcath) is unclear in patients with bicuspid aortic valve (BAV). This study aimed to compare iAVA measurements obtained using four different methodologies in BAV and tricuspid aortic valve (TAV) patients, using mPGcath as a reference standard. METHODS: We retrospectively reviewed patients who underwent comprehensive assessment of AS, including two-dimensional (2D) transthoracic echocardiography (TTE), three-dimensional (3D) transesophageal echocardiography (TEE), multidetector computed tomography (MDCT), and catheterization, at our institution between 2019 and 2022. iAVA was measured using the continuity eq. (CE) with left ventricular outflow tract area obtained by 2D TTE, 3D TEE, and MDCT, as well as planimetric 3D TEE. RESULTS AND CONCLUSIONS: Among 564 patients (64 with BAV and 500 with TAV), 64 propensity-matched pairs of patients with BAV and TAV were analyzed. iAVACE(2DTTE) led to overestimation of AS severity (BAV, 23.4%; TAV, 28.1%) and iAVACE(MDCT) led to underestimation of AS severity (BAV, 29.3%; TAV, 16.7%), whereas iAVACE(3DTEE) and iAVAPlani(3DTEE) resulted in a reduction in the discordance of AS grading. A moderate correlation was observed between mPGcath and iAVACE(3DTEE) (BAV, r = -0.63; TAV, r = -0.68), with iAVACE(3DTEE) corresponding to the current guidelines' cutoff value (BAV, 0.58 cm2/m2; TAV, 0.60 cm2/m2). Discordance/concordance between iAVA and mPGcath in evaluating AS severity varies depending on the methodology and imaging modality used. The use of iAVACE(3DTEE) is valuable for reconciling the discordant AS grading in BAV patients as well as TAV.

3.
Trials ; 25(1): 535, 2024 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-39138581

RESUMEN

BACKGROUND: In cardiac surgical procedures, patients carrying high-risk profiles are prone to encompass complicated cardiopulmonary bypass (CPB) separation. Intraoperative transesophageal echocardiography (TEE), a readily available tool, is utilized to detect cardiac structural and functional pathologies as well as to facilitate clinical management of CPB separation, especially in the episodes of hemodynamic compromise. However, the conventional TEE examination, always performed in a liberal fashion without any restriction of view acquisition, is relatively time-consuming; there appear its flaws in the context of critically severe status. We therefore developed the perioperative rescue transesophageal echocardiography (PReTEE), a simplified three-view TEE protocol consisting of midesophageal four chamber, midesophageal left ventricular long axis, and transgastric short axis. METHODS: This is a single-center and randomized controlled trial which will be implemented in Peking Union Medical College Hospital, Beijing, China. A total of 46 TEE scans are schemed to be performed by 6 operators participating in and randomly assigned to either the PReTEE or the conventional TEE group. This study is purposed to investigate whether the efficiency of discriminating leading causes of difficult CPB wean-off can be significantly improved via an abbreviated sequence of TEE views. The primary outcome of interest is the difference between the groups of PReTEE and the conventional TEE in the successful discrimination of etiologies in specified 120 s. Cox proportional hazards model will be further employed to calculate the outcome difference. DISCUSSION: The estimated results of this trial are oriented at verifying whether a simplified TEE exam sequence can improve the efficiency of etiologies discrimination during CPB separation in cardiac surgery. TRIAL REGISTRATION: ClinicalTrials.gov NCT05960552. Registered on 6 July 2023.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Puente Cardiopulmonar , Ecocardiografía Transesofágica , Humanos , Ecocardiografía Transesofágica/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto , Factores de Riesgo , Masculino , Valor Predictivo de las Pruebas
4.
Rev Cardiovasc Med ; 25(7): 236, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39139430

RESUMEN

Background: Atrial fibrillation (AF) can lead to a decline in left atrial appendage (LAA) function, potentially increasing the likelihood of LAA thrombus (LAAT) and spontaneous echo contrast (SEC). Measuring LAA flow velocity through transesophageal echocardiography (TEE) is currently the primary method for evaluating LAA function. This study aims to explore the potential correlation between anterior mitral annular plane systolic excursion (aMAPSE) and LAA stasis in patients with non-valvular atrial fibrillation (NVAF). Methods: A total of 465 patients with NVAF were enrolled between October 2018 and November 2021. Transthoracic echocardiography (TTE) and TEE were performed before scheduled electrical cardioversion. Propensity score matching (PSM) was used to balance confounders between the groups with and without LAAT/dense SEC. Results: Patients in the LAAT/dense SEC group showed increased left atrial (LA) diameter, LAA area, alongside reduced left ventricular ejection fraction (LVEF), LAA velocity, conjunction thickening ratio, aMAPSE, and LAA fraction area change (FAC) compared to those in the non-LAAT/dense SEC group. Multivariate logistic regression analysis identified aMAPSE and LAA FAC as independent predictors for LAAT/dense SEC. Specifically, an aMAPSE of < 6.76 mm and an LAA FAC of < 29.65% predicted LAAT/dense SEC with high diagnostic accuracy, demonstrated by an area under the curve (AUC) of 0.81 (sensitivity 0.81, specificity 0.80) for aMAPSE, and an AUC of 0.80 (sensitivity 0.70, specificity 0.84) for LAA FAC. Conclusions: Both aMAPSE and LAA FAC independently correlated with and accurately predict LAAT/dense SEC. Incorporating aMAPSE into routine TEE evaluations for LAA function alongside LAA flow velocity is recommended.

5.
Artículo en Inglés | MEDLINE | ID: mdl-39099535

RESUMEN

Transcutaneous aortic valve replacement (TAVR) has evolved from a complex procedure meant only for patients at prohibitive risk for surgery to a commonly performed procedure across a wide variety of clinical scenarios including the treatment of failed aortic valve bioprosthesis. Annuloplasty rings in the aortic position such as HAART 300 (Biostable Science and Engineering) have been introduced in the management of native aortic regurgitation. Percutaneous management of failed bioprosthesis rings in the aortic position has not been widely described. We present a case of a 69-year-old man with recurrent aortic regurgitation successfully treated with TAVR using a SAPIEN 3 valve within a HAART 300 ring.

6.
Wien Klin Wochenschr ; 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39179907

RESUMEN

Isolated pulmonary valve endocarditis (IPE) is a rare form of infectious endocarditis. This article reports the case of a 49-year-old patient with IPE who was initially admitted with suspected cholecystitis. After vegetations were detected by transthoracic (TTE) and transesophageal echocardiography (TEE), antibiotic therapy in accordance with the antibiogram was primarily attempted; however, due to persistently elevated infection parameters and structural valve damage a pulmonary valve replacement was eventually performed.

7.
Tunis Med ; 102(8): 496-499, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39129578

RESUMEN

INTRODUCTION: Endocarditis associated with medical care is a rare and serious entity. The risk of occurrence is increased in hemodialysis patients due to the immunosuppression and the multiplicity of vascular accesses of different kinds. The mode of revelation can be variable given the diversity of symptoms it causes. Herein, we describe the case of endocarditis associated with medical care in a patient with renal failure who presents with neurological symptoms. OBSERVATION: A 38-year-old patient with a history of kidney disease in the hemodialysis stage presented to the emergency room with altered neurological status in the context of fever. The patient's condition requires airway control, sedation, and vasopressor medication. Brain imaging revealed Fisher 4 subarachnoid hemorrhage with brain turgor. Transthoracic and transesophageal cardiac ultrasound exploration revealed infective mitro-aortic endocarditis with trigonal abscess fistulized in the left ventricle and destruction of the aortic valve with massive regurgitation. The additional imaging in a second step did not highlight any images of mycotic aneurysm. The indication for early surgery was not approved given the hemodynamic instability and the poor intracerebral hemodynamics demonstrated by transcranial doppler ultrasound. The initial outcome under antibiotic treatment and renal replacement was favorable. But the subsequent course was fatal due to septic shock with multiple organ failure. CONCLUSION: The diagnosis of infective endocarditis should always be considered in hemodialysis patients presenting in a septic state with signs of systemic involvement. It is a source of mortality in these debilitated patients.


Asunto(s)
Endocarditis Bacteriana , Diálisis Renal , Hemorragia Subaracnoidea , Humanos , Diálisis Renal/efectos adversos , Hemorragia Subaracnoidea/etiología , Hemorragia Subaracnoidea/diagnóstico , Hemorragia Subaracnoidea/terapia , Adulto , Masculino , Endocarditis Bacteriana/diagnóstico , Endocarditis Bacteriana/complicaciones , Endocarditis Bacteriana/etiología , Endocarditis Bacteriana/microbiología , Resultado Fatal , Infecciones Relacionadas con Catéteres/diagnóstico , Infecciones Relacionadas con Catéteres/microbiología , Infecciones Relacionadas con Catéteres/etiología
8.
J Cardiovasc Echogr ; 34(2): 85-89, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39086698

RESUMEN

Aortic intramural hematoma (IMH) accounts for approximately 10%-25% of acute aortic syndromes (AAS), and multi-slice computed tomography and magnetic resonance imaging are the leading techniques for diagnosis and classification. In this context, endovascular strategies provide a valid alternative to traditional open surgery and transesophageal echocardiography (TEE) could play a role in therapeutic decision-making and in endovascular repair procedure guidance. A 57-year-old female patient with IMH extending from the left subclavian artery to the upper tract of the abdominal aorta, underwent endovascular aortic repair using an unibody single-branched stent grafting in the aortic arch and descending aorta with a side branch inserted in the left common carotid artery. To restore proper flow in the left axillary artery, a carotid-subclavian bypass graft was performed. The procedure was guided by angiography and TEE. Intraoperative TEE revealed aortic IMH with a significant fluid component in the middle tunic of the aorta with a wall thickness of over 13 mm. TEE was useful in monitoring of all steps of the procedure, showing the presence of the guidewires into the true lumen, the advancement of the prosthesis, and the phases of release and anchoring. This case highlights the importance of using multimodality imaging techniques to evaluate AAS and demonstrates the growing potential of TEE in guiding endovascular repairs.

9.
Diagnostics (Basel) ; 14(15)2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39125530

RESUMEN

Segmenting the left ventricle from the transgastric short-axis views (TSVs) on transesophageal echocardiography (TEE) is the cornerstone for cardiovascular assessment during perioperative management. Even for seasoned professionals, the procedure remains time-consuming and experience-dependent. The current study aims to evaluate the feasibility of deep learning for automatic segmentation by assessing the validity of different U-Net algorithms. A large dataset containing 1388 TSV acquisitions was retrospectively collected from 451 patients (32% women, average age 53.42 years) who underwent perioperative TEE between July 2015 and October 2023. With image preprocessing and data augmentation, 3336 images were included in the training set, 138 images in the validation set, and 138 images in the test set. Four deep neural networks (U-Net, Attention U-Net, UNet++, and UNeXt) were employed for left ventricle segmentation and compared in terms of the Jaccard similarity coefficient (JSC) and Dice similarity coefficient (DSC) on the test set, as well as the number of network parameters, training time, and inference time. The Attention U-Net and U-Net++ models performed better in terms of JSC (the highest average JSC: 86.02%) and DSC (the highest average DSC: 92.00%), the UNeXt model had the smallest network parameters (1.47 million), and the U-Net model had the least training time (6428.65 s) and inference time for a single image (101.75 ms). The Attention U-Net model outperformed the other three models in challenging cases, including the impaired boundary of left ventricle and the artifact of the papillary muscle. This pioneering exploration demonstrated the feasibility of deep learning for the segmentation of the left ventricle from TSV on TEE, which will facilitate an accelerated and objective alternative of cardiovascular assessment for perioperative management.

10.
JACC Adv ; 3(7): 100977, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39129997

RESUMEN

Background: Patients with atrial fibrillation (AF) remain at increased risk of thromboembolism despite apparent maintenance of sinus rhythm with the cause often attributed to periods of asymptomatic AF. Atrial mechanical discordance, with the body of the left atrium (LA) in sinus rhythm and the left atrial appendage (LAA) in AF may also be a contributor. Objectives: The purpose of this study was to assess the frequency of electrocardiogram (ECG) rhythm and LAA and/right atrial appendage (RAA) Doppler ejection phenotype (transesophageal echocardiography [TEE]) discordance in patients undergoing cardiac surgery. Methods: A total of 124 patients undergoing coronary artery bypass graft (CABG), CABG and valve surgery, or isolated valve repair or replacement (valve ± CABG) were prospectively studied. Intraoperative surface ECG rhythm strip and TEE were performed before cardiopulmonary bypass. The ECG and TEE LAA/RAA Doppler spectrum were independently classified as sinus or AF. Results: Of 107 patients (age 65 ± 12 years; 31% female; 65% CABG, 31% valve ± CABG) without a history of AF, 39 (36%) had ECG and LAA and/or RAA discordance (ECG/LAA Doppler discordance, n = 12 [11%]; ECG/RAA Doppler discordance, n = 35 [33%]). There was no significant difference between concordant and discordant groups with regard to age, gender, history of hypertension, diabetes, heart failure, or stroke (all P > 0.05). Conclusions: A large minority of patients without a history of AF undergoing cardiac surgery have ECG/atrial appendage Doppler discordance, a setting that may promote thromboembolism in non-anticoagulated patients. Clinical parameters do not identify patients at increased risk for discordance.

11.
JACC Adv ; 3(7): 100976, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39130041
12.
Cureus ; 16(7): e64256, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39130923

RESUMEN

Background and objective While transesophageal echocardiography (TEE) is crucial in cardiac surgery, the probe insertion can be challenging. This observational study aimed to identify predictive factors associated with difficult TEE probe insertion in adult cardiac surgery patients. Methods A total of 119 adult patients undergoing cardiac surgery were included in the study. Demographic variables (age, gender, and BMI) and airway factors (modified Mallampati classification, modified Cormack-Lehane grading, and thyromental distance) were analyzed. The difficulty of TEE probe insertion was categorized into three grades, and various maneuvers were assessed for difficult insertions. Results Of note, 30.3% of insertions were difficult. Male gender (OR: 1.8), BMI ≥30 kg/m2 (OR: 2.5), Mallampati class III-IV (OR: 3.2), Cormack-Lehane grade IIb-IV (OR: 2.7), and thyromental distance <6.5 cm (OR: 1.9) were significantly associated with difficult insertion. Jaw thrust was the most effective maneuver (58.3%) for difficult cases. Conclusions Based on our findings, several demographic and airway factors predict difficulties in TEE probe insertion. Understanding these factors can help clinicians anticipate challenges and prepare appropriate strategies, potentially reducing complications associated with probe insertion.

13.
Front Cardiovasc Med ; 11: 1428380, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39145278

RESUMEN

Purpose: Percutaneous patent foramen ovale (PFO) closure is becoming more and more common for the treatment or prevention of PFO-associated right-to-left shunt (RLS). This study aims to investigate the value of transesophageal echocardiography (TEE) in percutaneous PFO closure, and to explore a new method that can improve intraoperative diagnosis and surgical safety. Materials and methods: Based on our inclusion and exclusion criteria, we enrolled 73 patients between 16 and 70 years old (average age 43.25 ± 14.87 years) who underwent percutaneous PFO closure at the Department of Cardiac Surgery, Zhongshan Hospital (Xiamen), Fudan University, from January 2022 to December 2023. Out of the 73 enrolled patients, there were 28 males (38.36%) and 45 females (61.64%), 29 migraine patients (39.73%), 14 patients (19.19%) with headache and dizziness, 14 patients (19.18%) with a history of cerebral infarction (CI), and 25 patients (34.25%) with CI, lacunar infarction or ischemic focus on magnetic resonance imaging (MRI). All patients received routine transthoracic echocardiography (TTE) and agitated saline contrast echocardiography (ASCE) before operations. Percutaneous closure of PFO was completed under the guidance of TEE. In 12 patients, the method of "injection of heparinized sterile saline through the delivery sheath" was used to observe their RLS, and the anatomical characteristics of the PFO according to the shunt path were monitored and evaluated. This method was also applied to some patients to guide the conveyor to pass through the foramen ovale (FO) channel safely and effectively, thereby improving the success rate of PFO closure. Results: The application of TEE during the procedure of percutaneous PFO closure, including preoperative evaluation, intraoperative guidance, and postoperative reevaluation, can offer further details about the anatomical and shunt characteristics of PFO, improve the diagnosis rate, and confirm the safety of the surgical path. It ensures the safety and reliability of the whole operation, greatly improving the success rate and reducing postoperative complications. Conclusions: TEE guidance of percutaneous PFO closure has the advantages of minimal trauma, no radiation and real-time visualization, while injecting heparinized sterile saline through the delivery sheath is safer and more effective in improving the success rate and reducing postoperative complications.

14.
Cureus ; 16(7): e64940, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39156246

RESUMEN

The congenital anomalous origin of the right coronary artery (AORCA) with an incongruous course is a rare malformation that can manifest as exertional chest pain, syncope, arrhythmias, heart failure, and sudden cardiac death. We present a case of a 42-year-old male with a history of hypercholesterolemia who presented with chest pain and dizziness upon exertion for two weeks. The physical examination was unremarkable, and the patient was hemodynamically stable. Initial blood tests were normal. Electrocardiogram (ECG) showed sinus bradycardia at 56 bpm without ST or T wave changes. A cardiac stress test indicated antero-apical inducible ischemia with a moderate probability of stress-induced ischemia. Computed tomography angiography (CTA) revealed an AORCA with a high interarterial course between the pulmonary artery and the aorta. Subsequent left heart catheterization confirmed the anomalous origin and revealed atherosclerotic disease. This anomaly was identified as the cause of the patient's symptoms due to the compression of the right coronary artery (RCA). The patient was treated with aspirin and statin and underwent successful internal mammary artery-RCA bypass grafting. Postoperatively, the patient's symptoms resolved, and there were no further episodes of chest pain.

15.
Heart Rhythm ; 2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-39154871

RESUMEN

BACKGROUND: Multiple studies continue to evaluate the use of intracardiac echocardiography (ICE) and transesophageal echocardiography (TEE) for guiding left atrial appendage occlusion (LAAO). OBJECTIVE: To conduct an updated meta-analysis comparing the effectiveness and safety outcomes of both imaging modalities. METHODS: PubMed, Cochrane, and Embase were searched for studies comparing ICE vs TEE to guide LAAO. Odds ratios (OR) with 95% confidence intervals (CI) were pooled using a random-effects model. The primary effectiveness endpoint was procedural success. The primary safety endpoint included the overall complications rate. Additional safety outcomes were assessed as secondary endpoints. Subgroup analysis of primary endpoints was conducted according to device type (Amulet, LAmbre, Watchman, Watchman FLX) and study region (American, Asia, Europe). We used R version 4.3.1 for all statistical analyses. RESULTS: Our meta-analysis included 19 observational studies encompassing 42,474 patients, of whom 4,415 (10.4%) underwent ICE-guided LAAO. Compared with TEE, ICE was associated with a marginally higher procedural success (OR 1.33; 95% CI: 1.01-1.76; p=0.04; I2=0%). There was no significant difference in the overall complications rate (OR 1.02; 95% CI: 0.77-1.36; p=0.89; I2=5%). However, ICE showed higher rates of pericardial effusion (OR 2.11; 95% CI: 1.47-3.03; p<0.001; I2=0%) and residual iatrogenic atrial septal defect (iASD) (OR 1.52; 95% CI: 1.15-2.03; p<0.004; I2=0%). Subgroup analysis revealed variations in procedural success within the ICE group across study regions (p=0.02). CONCLUSION: In this updated meta-analysis, the increasing adoption of ICE-guided LAAO demonstrated higher procedural success rates compared to TEE, although with limited statistical significance. Overall complication rates were similar; however, ICE showed higher rates of pericardial effusion and residual iASD.

16.
J Am Heart Assoc ; 13(16): e035826, 2024 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-39158546

RESUMEN

BACKGROUND: Variations in the aortomitral positional anatomy, including aortic root rotation appear to be related to variations in the location of the conduction system, including the bundle of His. However, little is known about their clinical significance. METHODS AND RESULTS: This study included 147 patients with normal ECGs who underwent mitral valve surgery. The aortomitral anatomy was classified using preoperative 3-dimensional transesophageal echocardiography, and postoperative conduction disorders, including atrioventricular block and bundle branch block, were analyzed. Variations classified as aortomitral appearance were designated as having a center appearance (85.7%, n=126/147) or lateral appearance (14.3%, n=21/147) on the basis of whether the aortic root was located at the center or was shifted to the left fibrous trigone side. Subsequently, those with a center appearance, aortic root rotation was classified as having a center rotation (83.3% [n=105/126]), in which the commissure of the left and noncoronary aortic leaflet was located at the center, lateral rotation (14.3% [n=18/126]), rotated to the left trigone side, or medial rotation (2.4% [n=3/126]), rotated to the right. The incidence of 3-month persistent new-onset conduction disorder was higher in the lateral appearance than the center appearance group (21.1% versus 5.0%; P=0.031) and higher in the lateral rotation than in the center or medial rotation groups (29.4% versus 1.0% versus 0.0%, respectively; P<0.001). CONCLUSIONS: Aortomitral variations can be classified using 3-dimensional transesophageal echocardiography. Lateral appearance and lateral rotation are risk factors for conduction disorders in mitral valve surgery.


Asunto(s)
Bloqueo Atrioventricular , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Válvula Mitral , Humanos , Masculino , Femenino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Persona de Mediana Edad , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/diagnóstico , Anciano , Estudios Retrospectivos , Electrocardiografía , Bloqueo de Rama/fisiopatología , Bloqueo de Rama/etiología , Factores de Riesgo , Aorta/diagnóstico por imagen , Aorta/cirugía , Aorta/fisiopatología , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Adulto , Resultado del Tratamiento , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/diagnóstico por imagen
17.
Cureus ; 16(7): e64892, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39161491

RESUMEN

This case report documents a rare congenital anomaly in a 27-year-old man of African descent presenting with exertional chest discomfort and shortness of breath, diagnosed with a ruptured right sinus of Valsalva (RSOV) aneurysm dissecting into the interventricular septum (IVS), creating an aneurysmal cavity. Such occurrences are typically rare, with this type of aneurysm largely manifesting in the right atrium, making its presentation in the IVS without intracardiac communication exceptionally uncommon. Cardiac imaging, including transesophageal echocardiography and cardiac magnetic resonance imaging (CMR), played pivotal roles in visualizing the structural abnormality and planning the subsequent surgical intervention. The patient's treatment included heart failure optimization, followed by surgery to repair the aneurysmal cavity while preserving the native aortic valve. Postoperative challenges included a complete heart block managed by cardiac resynchronization therapy and an intracardiac defibrillator. The report underscores the importance of advanced imaging in diagnosing and managing rare cardiac anomalies, highlighting the aneurysm's unique rupture pattern and location.

18.
IDCases ; 37: e02039, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39193405

RESUMEN

The risk of infective endocarditis remains a major concern in patients with congenital heart disease; nevertheless, use of devices and prostheses in corrective surgery may have contributed to an increased incidence. Infective endocarditis due to Salmonella species are infrequently reported, therefore, their clinical presentations, prognosis and optimal treatment guideline are poorly described in literature. Here, we report a case of an 18-year-old diabetic lady with history of device closure of Patent ductus arteriosus and closure of peri-membranous small Ventricular septal defect in the year of 2005 and 2018 respectively who presented to us with high-grade fever for 10 days without any focal symptom. She was initially diagnosed as a case of Enteric fever based on serological tests for Salmonella species, later Transesophageal echocardiography confirmed infective endocarditis. The patient was treated with combination of antibiotics for a total 6-week duration. Although very rare, Salmonella have a predilection for the heart valves, particularly mitral and aortic valves. Diagnosis may be difficult, blood culture is often negative and a Transesophageal echocardiography should be performed without delay particularly in high risk patients. In most cases Salmonella endocarditis can be successfully treated with antimicrobials alone.

20.
Diagnostics (Basel) ; 14(16)2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39202243

RESUMEN

BACKGROUND/OBJECTIVES: To close the atrial septal defect (ASD) with the transcatheter method, correctly defining the defect and selecting the appropriate closure device size are the most critical steps for the procedure's success. Although ASD can be successfully closed under the guidance of three-dimensional (3D) transesophageal echocardiography (TEE) and two-dimensional (2D) TEE, measurement comparisons between different types of defects are still needed. METHODS: Our study was designed retrospectively. Sixty-one patients who underwent transcatheter ASD closure with 2D TEE and 3D TEE between 2020 and 2024 were included. The patients were divided into three groups according to the defect shape: circular, oval, and complex; and the measurement results, perioperative process, and clinical outcomes were compared in each group. RESULTS: The average age of the patients was 35.05 ± 13.87 years, and 41 (67.2%) were women. The average follow-up period of the patients was 15.3 ± 9.18 months. No statistical significance was observed in the comparison of measurements obtained with 3D TEE and 2D TEE in the circular and oval defect groups. The differences between the minimum defect diameters of complex defects measured by 2D TEE and 3D TEE (p: 0.037), IVC rims (p < 0.001), aortic rims (p: 0.012), and the differences between implanted device dimensions and the maximum defect diameters measured by both methods were compared; statistical significance was observed (p: 0.025). CONCLUSIONS: In circular and non-complex oval defects, it has been observed that the size of the closure device selected with 2D TEE or 3D TEE is optimal, and the procedure is practical and feasible. While the closure of complex ASDs with 3D TEE provides reliable and optimal results, using only 2D TEE in complex ASDs may lead to selecting a smaller-sized device.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA