Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.069
Filtrar
1.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38742501

RESUMEN

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Asunto(s)
Lentes de Contacto , Queratocono , Esclerótica , Agudeza Visual , Humanos , Queratocono/cirugía , Queratocono/diagnóstico , Queratocono/fisiopatología , Queratocono/terapia , Femenino , Masculino , Adulto , Esclerótica/cirugía , Implantación de Prótesis/métodos , Implantación de Prótesis/instrumentación , Resultado del Tratamiento , Topografía de la Córnea , Prótesis e Implantes , Adulto Joven , Ajuste de Prótesis/métodos , Adolescente , Sustancia Propia/cirugía
2.
Vestn Oftalmol ; 140(2): 85-90, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38742503

RESUMEN

The introduction of early diagnostic methods for keratoconus into clinical practice has become the basis for the development of surgical treatment techniques for this pathology, such as corneal collagen crosslinking and interlamellar keratoplasty with implantation of intrastromal segments. The article analyzes the results of research by Russian and foreign specialists in these areas and presents the data on the combination of SMILE surgery and corneal crosslinking, the Rome protocol of corneal crosslinking, modifications of interlamellar keratoplasty, the use of femtosecond laser technologies, and some pilot studies. Modern requirements for ophthalmological care require a personalized approach to each patient, and therefore the surgeon should have a wide range of surgical methods of treatment applicable to different patient cohorts. The described methods of treatment, according to the authors, are the most promising.


Asunto(s)
Queratocono , Queratocono/cirugía , Queratocono/diagnóstico , Humanos , Córnea/cirugía , Córnea/diagnóstico por imagen , Trasplante de Córnea/métodos , Cirugía Laser de Córnea/métodos , Resultado del Tratamiento , Colágeno
3.
Transl Vis Sci Technol ; 13(5): 7, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38727695

RESUMEN

Purpose: Multiple clinical visits are necessary to determine progression of keratoconus before offering corneal cross-linking. The purpose of this study was to develop a neural network that can potentially predict progression during the initial visit using tomography images and other clinical risk factors. Methods: The neural network's development depended on data from 570 keratoconus eyes. During the initial visit, numerical risk factors and posterior elevation maps from Scheimpflug imaging were collected. Increase of steepest keratometry of 1 diopter during follow-up was used as the progression criterion. The data were partitioned into training, validation, and test sets. The first two were used for training, and the latter for performance statistics. The impact of individual risk factors and images was assessed using ablation studies and class activation maps. Results: The most accurate prediction of progression during the initial visit was obtained by using a combination of MobileNet and a multilayer perceptron with an accuracy of 0.83. Using numerical risk factors alone resulted in an accuracy of 0.82. The use of only images had an accuracy of 0.77. The most influential risk factors in the ablation study were age and posterior elevation. The greatest activation in the class activation maps was seen at the highest posterior elevation where there was significant deviation from the best fit sphere. Conclusions: The neural network has exhibited good performance in predicting potential future progression during the initial visit. Translational Relevance: The developed neural network could be of clinical significance for keratoconus patients by identifying individuals at risk of progression.


Asunto(s)
Topografía de la Córnea , Aprendizaje Profundo , Progresión de la Enfermedad , Queratocono , Queratocono/diagnóstico por imagen , Queratocono/diagnóstico , Humanos , Femenino , Masculino , Adulto , Topografía de la Córnea/métodos , Adulto Joven , Factores de Riesgo , Córnea/diagnóstico por imagen , Córnea/patología , Adolescente , Persona de Mediana Edad , Redes Neurales de la Computación
4.
Sci Rep ; 14(1): 9984, 2024 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-38693352

RESUMEN

The aim of this work is to quantitatively assess the wavefront phase of keratoconic eyes measured by the ocular aberrometer t·eyede (based on WaveFront Phase Imaging Sensor), characterized by a lateral resolution of 8.6 µm without requiring any optical element to sample the wavefront information. We evaluated the parameters: root mean square error, Peak-to-Valley, and amplitude of the predominant frequency (Fourier Transform analysis) of a section of the High-Pass filter map in keratoconic and healthy cohorts. Furthermore, we have analyzed keratoconic eyes that presented dark-light bands in this map to assess their period and orientation with the Fourier Transform. There are significant statistical differences (p value < 0.001) between healthy and keratoconic eyes in the three parameters, demonstrating a tendency to increase with the severity of the disease. Otherwise, the quantification of the bands reveals that the width is independent of eye laterality and keratoconic stage as orientation, which tends to be oblique. In conclusion, the quantitative results obtained with t·eyede could help to diagnose and monitor the progression of keratoconus.


Asunto(s)
Queratocono , Queratocono/diagnóstico por imagen , Queratocono/diagnóstico , Humanos , Adulto , Femenino , Masculino , Topografía de la Córnea/métodos , Adulto Joven , Aberrometría/métodos , Córnea/diagnóstico por imagen , Córnea/patología , Análisis de Fourier
5.
BMC Ophthalmol ; 24(1): 201, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38698363

RESUMEN

BACKGROUND: We aimed to employ Optical Coherence Tomography Angiography (OCTA) to comprehensively assess changes in the optic nerve head (ONH) and macular perfusion before and after the Corneal Collagen Cross-Linking (CCL) procedure in patients with keratoconus. METHODS: A total of 22 keratoconus patient's candidate for CCL procedures were included based on specific criteria, with meticulous exclusion criteria in place to minimize potential confounders. Participants underwent OCTA assessments of the ONH and macula using the Spectralis OCT (Heidelberg) before CCL, as well as at 1- and 3-months post-CCL. MATLAB software was utilized for image analysis. RESULTS: The mean age of the participants was 20.09 ± 6.11, including 59% male, and the mean intraocular pressure (IOP) before the surgery was 13.59 ± 2.85 mmHg. Peripapillary Retinal nerve fiber layer (ppRNFL) thickness and overall retinal thickness remained stable post-CCL. However, significant alterations were observed in macular vessel density, emphasizing regional variations in vascular response. For macular large vessel density (LVD), both superficial and deep vascular complex (SVC and DVC) demonstrated significant differences between before surgery and the 3 months post-surgery follow-up (p < 0.001 and p = 0.002, respectively). Optic nerve head markers demonstrated relative stability, except for changes in avascular complex density, which was 49.2 ± 2.2% before the surgery and decrease to 47.6 ± 1.7% three months after the operation (P-value = 0.005). CONCLUSION: While CCL appears to maintain the integrity of certain ocular structures, alterations in macular perfusion post-CCL suggest potential effects on retinal blood supply. Long-term monitoring is crucial to understand the implications of these changes, particularly in the context of conditions such as diabetes.


Asunto(s)
Colágeno , Reactivos de Enlaces Cruzados , Angiografía con Fluoresceína , Queratocono , Disco Óptico , Vasos Retinianos , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Queratocono/fisiopatología , Queratocono/diagnóstico , Masculino , Femenino , Colágeno/metabolismo , Adulto Joven , Adulto , Angiografía con Fluoresceína/métodos , Vasos Retinianos/diagnóstico por imagen , Vasos Retinianos/fisiopatología , Disco Óptico/irrigación sanguínea , Adolescente , Estudios Prospectivos , Fármacos Fotosensibilizantes/uso terapéutico , Fotoquimioterapia/métodos , Mácula Lútea/diagnóstico por imagen , Mácula Lútea/irrigación sanguínea
6.
Jpn J Ophthalmol ; 68(3): 225-232, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38557918

RESUMEN

PURPOSE: We aimed to compare the efficacy and safety of accelerated contact lens-assisted cross-linking (CA-CXL) with Lotrafilcon B and Comfilcon A lenses in keratoconus (KC) patients with thin corneas. STUDY DESIGN: Retrospective, single-center study. MATERIALS AND METHODS: We retrospectively included 51 eyes of 39 KC patients with corneal thickness <400µm after epithelial scraping (Epi-off), who underwent accelerated CA-CXL treatment with Lotrafilcon B (n=20) and Comfilcon A (n=31). Uncorrected and corrected distance visual acuity (UDVA and CDVA), manifest refraction values, corneal topographic data and endothelial cell density were recorded at preoperative and postoperative 1st, 3rd and 6th month controls. RESULTS: CDVA in the Comfilcon A group was higher than CDVA before surgery at 6 months postoperatively (p<0.001). When the two lenses were compared, CDVA was found to be significantly higher in the Lotrafilcon B group in the preoperative, postoperative 1st month and 3rd month values, but there was no significant difference between the postoperative 6th month values (p=0.028, p=0.018, p=0.044, p=0.181, respectively). The maximum keratometry (Kmax) value at the 6th month after surgery in the Comfilcon A group was significantly lower than in the Lotrafilcon B group (p=0,009). There was no significant difference between the endothelial cell density values between the groups (p=0.623, p=0.609, p=0.794, p=0.458, respectively). There was no significant difference between the progression, regression, and stability rates of the two groups (p=0.714). CONCLUSIONS: Accelerated CA-CXL with Lotrafilcon B and Comfilcon A silicone hydrogel lenses is a safe and effective method to stop progression in patients with thin corneas.


Asunto(s)
Colágeno , Topografía de la Córnea , Reactivos de Enlaces Cruzados , Queratocono , Fotoquimioterapia , Fármacos Fotosensibilizantes , Refracción Ocular , Riboflavina , Agudeza Visual , Humanos , Queratocono/diagnóstico , Queratocono/fisiopatología , Queratocono/tratamiento farmacológico , Queratocono/terapia , Queratocono/metabolismo , Femenino , Masculino , Estudios Retrospectivos , Agudeza Visual/fisiología , Fármacos Fotosensibilizantes/uso terapéutico , Adulto , Riboflavina/uso terapéutico , Fotoquimioterapia/métodos , Adulto Joven , Refracción Ocular/fisiología , Colágeno/metabolismo , Resultado del Tratamiento , Córnea/patología , Rayos Ultravioleta , Estudios de Seguimiento , Adolescente , Recuento de Células , Sustancia Propia/metabolismo , Endotelio Corneal/patología , Lentes de Contacto Hidrofílicos , Reticulación Corneal
7.
Indian J Ophthalmol ; 72(5): 712-717, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38648433

RESUMEN

PURPOSE: To compare the changes encountered in corneal biomechanics and aberration profile following accelerated corneal collagen cross-linking (CXL) using hypo-osmolar and iso-osmolar riboflavin in corneal thicknesses of <400 and >400 microns, respectively. METHODS: This is a prospective, interventional, comparative study involving 100 eyes of 75 patients with progressive keratoconus. Eyes were divided into two groups based on corneal thickness: group 1 included eyes with a corneal thickness of <400 microns who underwent hypo-osmolar CXL, and group 2 included eyes with a corneal thickness of >400 microns who underwent iso-osmolar CXL. Corneal biomechanical and aberration profiles were evaluated and compared between groups. RESULTS: In group 1, all higher-order aberrations (HOA) except secondary astigmatism significantly decreased from baseline; however, in group 2, only coma and trefoil decreased. The corneal resistance factor and corneal hysteresis significantly improved in both groups, which was significantly greater in group 2 than in group 1. The change in inverse radius, deformation amplitude, and tomographic biomechanical index was significantly improved in group 2 as compared to group 1. CONCLUSION: Improvement in corrected distance visual acuity and decrease in HOA were significantly better in the hypo-osmolar CXL group; however, the improvement in biomechanical strength of the cornea was significantly better in the iso-osmolar group.


Asunto(s)
Colágeno , Córnea , Topografía de la Córnea , Reactivos de Enlaces Cruzados , Queratocono , Fármacos Fotosensibilizantes , Riboflavina , Rayos Ultravioleta , Agudeza Visual , Adolescente , Adulto , Femenino , Humanos , Masculino , Adulto Joven , Fenómenos Biomecánicos , Colágeno/metabolismo , Córnea/diagnóstico por imagen , Córnea/fisiopatología , Córnea/efectos de los fármacos , Sustancia Propia/metabolismo , Sustancia Propia/efectos de los fármacos , Aberración de Frente de Onda Corneal/fisiopatología , Reactivos de Enlaces Cruzados/uso terapéutico , Estudios de Seguimiento , Queratocono/tratamiento farmacológico , Queratocono/fisiopatología , Queratocono/diagnóstico , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/uso terapéutico , Estudios Prospectivos , Refracción Ocular/fisiología , Riboflavina/uso terapéutico , Agudeza Visual/fisiología , Niño
8.
Transl Vis Sci Technol ; 13(4): 13, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38587437

RESUMEN

Purpose: To assess the efficacy of an automated program for keratoconus and keratoconus suspect detection based on corneal measurements provided by a combined Placido disc and anterior segment optical coherence tomography (OCT) topographer. Methods: In a multicentric cross-sectional study, an artificial neural network (ANN) was created using 6677 eyes from an equal number of patients (classified as 2663 normal eyes, 1616 keratoconus eyes, 210 keratoconus suspect eyes, 1519 myopic postoperative eyes, and 669 abnormal eyes). Each group was randomly divided into a training set (70% of the dataset) and a validation set (the remaining 30%). A multilayer perceptron network with a backpropagation learning algorithm was developed for the study. Indexes used to train the ANN were based on curvature and elevation of both the anterior and posterior corneal surfaces and the new corneal OCT indexes-based on corneal, stromal, and epithelial thicknesses. Results: For keratoconus detection, our ANN showed an accuracy of 98.6%, precision of 96%, recall of 97.9%, and F1-score of 96.9%. For keratoconus suspect detection, our ANN showed an accuracy of 98.5%, precision of 83.6%, recall of 69.7%, and F1-score of 76%. Conclusions: Compared to previous literature, the addition of new OCT-based epithelial and stromal thickness indexes improves ANN detection capacity of keratoconus suspect eyes. For already stablished keratoconus our ANN detection capacity is excellent, but equivalent to previous evidence without incorporating such new OCT-based indexes. Translational Relevance: OCT-based epithelial and stromal thickness indexes improve ANN detection capacity of keratoconus on its early stages.


Asunto(s)
Queratocono , Humanos , Queratocono/diagnóstico por imagen , Tomografía de Coherencia Óptica , Estudios Transversales , Redes Neurales de la Computación , Córnea/diagnóstico por imagen
10.
Arq Bras Oftalmol ; 87(4): e2023, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38656029

RESUMEN

PURPOSE: To assess the outcomes of deep anterior lamellar keratoplasty or penetrating keratoplasty at the scar and the edema stages. METHODS: Forty-five patients (45 eyes) with keratoconus scar stage (scar group, n=26; penetrating keratoplasty a subgroup, n=7; deep anterior lamellar keratoplasty b subgroup, n=19) and keratoconus edema stage (edema group, n=19; penetrating keratoplasty c subgroup, n=12; deep anterior lamellar keratoplasty d group, n=7) who received penetrating keratoplasty or deep anterior lamellar keratoplasty from 2000 to 2022 were retrospectively studied. At 1, 6, and 12 months after surgery, the best-corrected visual acuity, astigmatism, spherical equivalent, corneal endothelial cell density, and complications were analyzed. RESULTS: The best-corrected visual acuity and average corneal endothelial cell loss rate were not significantly different between the scar and edema groups (p>0.05). At 6 and 12 months after surgery, the astigmatism and spherical equivalent in the scar group were significantly lower than those in the edema group (p<0.05). The spherical equivalent of the deep anterior lamellar keratoplasty b subgroup was lower than that of the penetrating keratoplasty a subgroup in the scar group 6 months after surgery (p<0.05). In the edema group, there was no significant difference in spherical equivalent between subgroups (p>0.05). There were no significant differences in best-corrected visual acuity and astigmatism between subgroups within the two groups (p>0.05). In comparison to the scar group, the edema group experienced more complications. According to a survival analysis, there was no statistically significant difference between the scar group and the edema group regarding the progression of vision. CONCLUSIONS: In terms of the outcomes and prognosis for vision after keratoplasty with edema stage and scar stage, deep anterior lamellar keratoplasty may be as effective as penetrating keratoplasty.


Asunto(s)
Cicatriz , Edema Corneal , Queratocono , Queratoplastia Penetrante , Agudeza Visual , Humanos , Queratocono/cirugía , Queratocono/complicaciones , Queratocono/fisiopatología , Masculino , Femenino , Estudios Retrospectivos , Queratoplastia Penetrante/métodos , Adulto , Cicatriz/etiología , Resultado del Tratamiento , Edema Corneal/cirugía , Edema Corneal/etiología , Adulto Joven , Trasplante de Córnea/métodos , Factores de Tiempo , Adolescente , Astigmatismo/cirugía , Astigmatismo/fisiopatología , Persona de Mediana Edad , Complicaciones Posoperatorias , Recuento de Células , Endotelio Corneal/patología , Endotelio Corneal/cirugía
11.
Int J Pharm ; 656: 124092, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38583820

RESUMEN

Corneal collagen crosslinking (CXL) is an effective method to halt the disease progression of keratoconus, a progressive corneal dystrophy leading to cone shaped cornea. Despite the efficacy of standard protocol, the concerning step of this procedure is epithelial debridement performed to facilitate the entry of riboflavin drug. Riboflavin, a key molecule in CXL protocol, is a sparsely permeable hydrophilic drug in corneal tissues. The present study has employed cell penetrating peptide (CPP), Tat2, to enhance the penetration of riboflavin molecule, and thereby improve currently followed CXL protocol. This study demonstrates approximately two-fold enhanced uptake of CPP riboflavin conjugate, Tat2riboflavin-5'Phosphate (RiTe conjugate), both in vitro and in vivo. Two different CXL protocols (Epi ON and Epi OFF) have been introduced and implemented in rabbit corneas using RiTe conjugate in the present study. The standard and RiTe conjugate mediated CXL procedures exhibited an equivalent extent of crosslinking in both the methods. Reduced keratocyte loss and no endothelial damage in RiTe conjugate mediated CXL further ascertains the safety of the proposed CXL protocols. Therefore, RiTe conjugate mediated CXL protocols present as potential alternatives to the standard keratoconus treatment in providing equally effective, less invasive and patient compliant treatment modality.


Asunto(s)
Colágeno , Córnea , Reactivos de Enlaces Cruzados , Queratocono , Riboflavina , Queratocono/tratamiento farmacológico , Queratocono/metabolismo , Animales , Conejos , Colágeno/metabolismo , Riboflavina/farmacología , Reactivos de Enlaces Cruzados/química , Córnea/metabolismo , Córnea/efectos de los fármacos , Péptidos de Penetración Celular , Fármacos Fotosensibilizantes/farmacología , Fármacos Fotosensibilizantes/uso terapéutico
12.
Indian J Ophthalmol ; 72(Suppl 3): S495-S500, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38648457

RESUMEN

PURPOSE: This retrospective longitudinal study evaluated the biomechanical E-staging in KC corneas before and after intracorneal ring segment (ICRS) implantation (Intacs® SK, Addition Technology, Illinois, United States). METHODS: Biomechanical E-staging for ectatic corneal diseases was applied retrospectively on 49 KC corneas of 41 patients who underwent ICRS implantation. The main outcome parameters included the Corvis Biomechanical Factor (CBiF, the linearized Corvis Biomechanical Index and the biomechanical parameters included), the resulting biomechanical E-staging, the stress-strain index, thinnest corneal thickness (TCT), maximal anterior keratometry (Kmax), and the anterior radius of curvature (ARC). They were evaluated at 1.9 ± 1.1 months preoperatively and postoperatively after 2.8 ± 0.7, 5.8 ± 1.0, and 10.6 ± 2.3 months. RESULTS: The CBiF decreased (4.9 ± 0.5 | 4.7 ± 0.5, P = 0.0013), and the E-staging increased significantly (2.8 ± 0.8 | 3.1 ± 0.9, P = 0.0012, paired t-test) from preoperatively to the first postoperative follow-up. The difference remained significant after 6 months; however, there was no more difference after 11 months. TCT was stable, whereas Kmax and ARC significantly decreased after ICRS implantation (TCT: 464 ± 49, 470 ± 51, 467 ± 38, 461 ± 48; Kmax: 56.3 ± 4.5, 54.7 ± 4.5, 54.2 ± 4.8, 54.1 ± 4.3; ARC: 51.5 ± 3.4, 48.3 ± 3.8, 48.6 ± 3.0, 48.6 ± 3.2 preoperatively and 3, 6, and 11 months postoperatively, respectively). Besides Kmax and ARC, Ambrósio's relational thickness to the horizontal profile (ARTh) was the only parameter that was significantly lower than preoperatively at any follow-up (P ≤ 0.0024, Wilcoxon matched-pairs test). CONCLUSION: Intacs® SK implantation results in an increasing biomechanical E-staging in the first postoperative months with stabilization near preoperative values after 1 year. Significantly lower ARTh values at any follow-up document the ICRS effect and contribute to a slightly higher postoperative biomechanical E-staging value.


Asunto(s)
Córnea , Sustancia Propia , Topografía de la Córnea , Queratocono , Prótesis e Implantes , Implantación de Prótesis , Agudeza Visual , Humanos , Queratocono/cirugía , Queratocono/diagnóstico , Queratocono/fisiopatología , Estudios Retrospectivos , Femenino , Masculino , Adulto , Implantación de Prótesis/métodos , Córnea/patología , Estudios de Seguimiento , Sustancia Propia/patología , Sustancia Propia/cirugía , Agudeza Visual/fisiología , Fenómenos Biomecánicos , Adulto Joven , Persona de Mediana Edad , Refracción Ocular/fisiología , Diseño de Prótesis , Adolescente
13.
BMJ Open Ophthalmol ; 9(1)2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38653536

RESUMEN

OBJECTIVE: Our objective is to develop a novel keratoconus image classification system that leverages multiple pretrained models and a transformer architecture to achieve state-of-the-art performance in detecting keratoconus. METHODS AND ANALYSIS: Three pretrained models were used to extract features from the input images. These models have been trained on large datasets and have demonstrated strong performance in various computer vision tasks.The extracted features from the three pretrained models were fused using a feature fusion technique. This fusion aimed to combine the strengths of each model and capture a more comprehensive representation of the input images. The fused features were then used as input to a vision transformer, a powerful architecture that has shown excellent performance in image classification tasks. The vision transformer learnt to classify the input images as either indicative of keratoconus or not.The proposed method was applied to the Shahroud Cohort Eye collection and keratoconus detection dataset. The performance of the model was evaluated using standard evaluation metrics such as accuracy, precision, recall and F1 score. RESULTS: The research results demonstrated that the proposed model achieved higher accuracy compared with using each model individually. CONCLUSION: The findings of this study suggest that the proposed approach can significantly improve the accuracy of image classification models for keratoconus detection. This approach can serve as an effective decision support system alongside physicians, aiding in the diagnosis of keratoconus and potentially reducing the need for invasive procedures such as corneal transplantation in severe cases.


Asunto(s)
Queratocono , Queratocono/diagnóstico , Queratocono/clasificación , Humanos , Córnea/patología , Algoritmos , Topografía de la Córnea/métodos
14.
J Refract Surg ; 40(4): e208-e217, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38593256

RESUMEN

PURPOSE: To evaluate spherical intraocular lens (IOL) implantation for cataracts in keratoconic eyes followed by optional refractive toric lens exchange to improve uncorrected visual acuity. METHODS: This retrospective study evaluated cataract surgery outcomes in keratoconic eyes. Eyes treated with a spherical IOL targeted for -2.00 diopters (D) either achieved acceptable manifest refraction and desired exchange with a toric IOL (Group 1); achieved satisfactory manifest refraction and chose to use spectacles or contact lenses (Group 2); or did not achieve acceptable refraction and used contact lenses (Group 3). Group 4 had single-stage toric IOL implantation with plano target. Corrected and uncorrected distance visual acuity (CDVA and UDVA) and keratometry were analyzed. RESULTS: Groups 1 to 4 had 18, 23, 18, and 26 eyes, respectively. A staged toric exchange resulted in significantly better (P = .02) UDVA (mean: 0.15 logMAR; 20/25 Snellen) than initial toric IOL implantation (0.24 logMAR; 20/30 Snellen). All toric IOL exchange eyes achieved 20/30 or better CDVA and 94% had 20/40 or better UDVA. Mean manifest cylinder significantly decreased from 3.39 D before lens exchange to 1.10 D postoperatively. CONCLUSIONS: Initial implantation of a spherical IOL in keratoconic eyes allows basing toric calculations on the manifest refraction, which may be more reliable than keratometry measurements in keratoconic eyes. UDVA after staged toric IOL exchange was significantly better than after initial toric IOL implantation. Importantly, by staging use of toric lenses, the authors avoided cases where patients required a rigid contact lens after a toric IOL was implanted. [J Refract Surg. 2024;40(4):e207-e217.].


Asunto(s)
Astigmatismo , Catarata , Queratocono , Lentes Intraoculares , Facoemulsificación , Humanos , Queratocono/complicaciones , Queratocono/cirugía , Estudios Retrospectivos , Facoemulsificación/métodos , Resultado del Tratamiento , Astigmatismo/cirugía , Refracción Ocular , Catarata/complicaciones
15.
J Refract Surg ; 40(4): e253-e259, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38593262

RESUMEN

PURPOSE: To compare simulated keratometry (SimK) and total corneal power (TCP) in keratoconic eyes, to determine whether the differences are systematic and predictable and to evaluate an adjusted TCP-based formula for intraocular lens (IOL) power calculation. METHODS: In a consecutive series of keratoconic eyes, measurements of SimK, TCP, posterior keratometry, and anterior and posterior corneal asphericities (Q-values) were retrospectively collected. The difference between SimK and TCP was linearly correlated to the biometric parameters. In a separate sample of keratoconic eyes that had undergone cataract surgery, IOL power was calculated with the Barrett Universal II, Hoffer QST, Holladay 1, Kane, and SRK/T formulas using the SimK and an adjusted TCP power. The respective prediction errors were calculated. RESULTS: A total of 382 keratoconic eyes (271 patients) were enrolled. An increasing overestimation of SimK by TCP was detected from stage I to III, with a significant correlation between the SimK and TCP difference and SimK in the whole sample (P < .0001, r2 = 0.1322). Approximately 7% of cases presented an underestimation of SimK by TCP. IOL power calculation with the adjusted TCP improved outcomes, achieving a maximum of 80% of eyes with a prediction error within ±0.50 diopters with the Hoffer QST, Holladay 1, and Kane formulas. CONCLUSIONS: Overall, SimK overestimated TCP. Such a difference could not be predicted by any variable. The proposed TCP-adjustment formula (TCPadj = TCP + 0.56 diopters) in keratoconic eyes for IOL power calculation might be valuable for improving refractive outcomes. [J Refract Surg. 2024;40(4):e253-e259.].


Asunto(s)
Queratocono , Lentes Intraoculares , Facoemulsificación , Humanos , Queratocono/diagnóstico , Implantación de Lentes Intraoculares/métodos , Estudios Retrospectivos , Facoemulsificación/métodos , Óptica y Fotónica , Refracción Ocular , Biometría/métodos
16.
J Refract Surg ; 40(4): e260-e269, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38593263

RESUMEN

PURPOSE: To compare the parameters of three different topographic devices (Pentacam HR, Oculus Optikgeräte GmbH; Sirius, Costruzione Strumenti Oftalmici; and Cassini, i-Optics) in grading the severity of keratoconus in cross-linked and non-cross-linked eyes. METHODS: This was a prospective comparative interventional study done in a tertiary eye care center, wherein 114 eyes of 68 patients with keratoconus were divided into two groups: 62 eyes that were observed and 52 eyes that were cross-linked. All eyes were evaluated on all three topographers at baseline, 3-month follow-up, and 6-month follow-up. RESULTS: The Sirius showed significantly lower values of mean flat keratometry in comparison to the Pentacam HR (limits of agreement [LoA]: 1.75 to 3.51%) and Cassini (LoA: 1.75 to 3.51%). The mean steep keratometry values were higher for the Cassini in comparison to the Pentacam HR (LoA: 4.39 to 7.02%) and Sirius (LoA: 3.51 to 6.14%). The mean steep keratometry values of the Sirius were significantly lower than those of the Pentacam HR and in both the cross-linked and observation groups (LoA: 3.51 to 6.14%). The mean keratometry values were significantly higher in the Cassini compared to the Pentacam HR (LoA: 3.51 to 8.77%) and significantly lower in the Sirius in comparison to the Pentacam HR (LoA: 3.51 to 6.14%). The mean difference in astigmatism was also statistically significant between the three tomographers in both groups, with the Cassini showing higher values (LoA: 3.51 to 5.26%) and the Sirius lower values than the Pentacam HR (LoA: 5.26 to 6.14%). CONCLUSIONS: The authors conclude the three devices cannot be used interchangeably. The Cassini showed better agreement and correlation with the Pentacam HR in the staging of keratoconus, whereas the Sirius tended to underdiagnose and under-stage the disease. [J Refract Surg. 2024;40(4):e260-e269.].


Asunto(s)
Queratocono , Humanos , Queratocono/diagnóstico , Topografía de la Córnea , Estudios Prospectivos , Reproducibilidad de los Resultados , Córnea
17.
Int Ophthalmol ; 44(1): 172, 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38594548

RESUMEN

INTRODUCTION: Keratoconus is a progressive disorder of the cornea that causes thinning (Sedaghat et al. in Sci Rep 11(1):11971, 2021), ectasia, and irregular astigmatism, resulting in poor visual acuity that cannot be corrected with standard sphero-cylindrical spectacle lenses. One feature distinguishing keratoconic corneas is ocular aberrations, manifesting up to five or six times the amount of higher-order aberrations than a normal, healthy eye. These aberrations can cause visual disturbances even at the very early stages of the disease. METHODS: In the past, a diagnosis was derived from clinical symptoms, but technological advances have revealed multiple pre-clinical features, allowing for the differentiation between keratoconic and normal eyes at a much earlier stage. These include anterior and posterior corneal surface elevations, the corneal pachymetry profile, corneal epithelial patterns, wavefront aberration metrics, and corneal biomechanics (Sedaghat et al. in Sci Rep 11(1):11971, 2021).This review discusses the aberrations associated with keratoconus, how to measure them, and treatment methods to minimize their negative influence. CONCLUSIONS: Early diagnosis can lead to early treatment and may allow for arresting progression, thereby improving the long-term prognosis. With the acceleration of refractive surgery, it is important to identify patients with keratoconus, as they are usually contraindicated for refractive surgery.


Asunto(s)
Astigmatismo , Queratocono , Humanos , Queratocono/diagnóstico , Queratocono/etiología , Queratocono/terapia , Topografía de la Córnea/métodos , Córnea , Astigmatismo/diagnóstico , Trastornos de la Visión
18.
Int Ophthalmol ; 44(1): 132, 2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38478103

RESUMEN

PURPOSE: Corneal biomechanics is an emerging field and the interest into physical and biological interrelations in the anterior part of the eye has significantly increased during the past years. There are many factors that determine corneal biomechanics such as hormonal fluctuations, hydration and environmental factors. Other factors that can affect the corneas are the age, the intraocular pressure and the central corneal thickness. The purpose of this review is to evaluate the factors affecting corneal biomechanics and the recent advancements in non-destructive, in vivo measurement techniques for early detection and improved management of corneal diseases. METHODS: Until recently, corneal biomechanics could not be directly assessed in humans and were instead inferred from geometrical cornea analysis and ex vivo biomechanical testing. The current research has made strides in studying and creating non-destructive and contactless techniques to measure the biomechanical properties of the cornea in vivo. RESULTS: Research has indicated that altered corneal biomechanics contribute to diseases such as keratoconus and glaucoma. The identification of pathological corneas through the new measurement techniques is imperative for preventing postoperative complications. CONCLUSIONS: Identification of pathological corneas is crucial for the prevention of postoperative complications. Therefore, a better understanding of corneal biomechanics will lead to earlier diagnosis of ectatic disorders, improve current refractive surgeries and allow for a better postoperative treatment.


Asunto(s)
Córnea , Queratocono , Humanos , Fenómenos Biomecánicos , Queratocono/diagnóstico , Queratocono/cirugía , Presión Intraocular , Complicaciones Posoperatorias
19.
Comput Biol Med ; 172: 108286, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38493602

RESUMEN

PURPOSE: To ascertain whether the integration of raw Corvis ST data with an end-to-end CNN can enhance the diagnosis of keratoconus (KC). METHOD: The Corvis ST is a non-contact device for in vivo measurement of corneal biomechanics. The CorNet was trained and validated on a dataset consisting of 1786 Corvis ST raw data from 1112 normal eyes and 674 KC eyes. Each raw data consists of the anterior and posterior corneal surface elevation during air-puff induced dynamic deformation. The architecture of CorNet utilizes four ResNet-inspired convolutional structures that employ 1 × 1 convolution in identity mapping. Gradient-weighted Class Activation Mapping (Grad-CAM) was adopted to visualize the attention allocation to diagnostic areas. Discriminative performance was assessed using metrics including the AUC of ROC curve, sensitivity, specificity, precision, accuracy, and F1 score. RESULTS: CorNet demonstrated outstanding performance in distinguishing KC from normal eyes, achieving an AUC of 0.971 (sensitivity: 92.49%, specificity: 91.54%) in the validation set, outperforming the best existing Corvis ST parameters, namely the Corvis Biomechanical Index (CBI) with an AUC of 0.947, and its updated version for Chinese populations (cCBI) with an AUC of 0.963. Though the ROC curve analysis showed no significant difference between CorNet and cCBI (p = 0.295), it indicated a notable difference between CorNet and CBI (p = 0.011). The Grad-CAM visualizations highlighted the significance of corneal deformation data during the loading phase rather than the unloading phase for KC diagnosis. CONCLUSION: This study proposed an end-to-end CNN approach utilizing raw biomechanical data by Corvis ST for KC detection, showing effectiveness comparable to or surpassing existing parameters provided by Corvis ST. The CorNet, autonomously learning comprehensive temporal and spatial features, demonstrated a promising performance for advancing KC diagnosis in ophthalmology.


Asunto(s)
Queratocono , Humanos , Queratocono/diagnóstico , Topografía de la Córnea , Córnea/diagnóstico por imagen , Curva ROC , Fenómenos Biomecánicos
20.
Sci Rep ; 14(1): 6937, 2024 03 23.
Artículo en Inglés | MEDLINE | ID: mdl-38521828

RESUMEN

Keratoconus (KC) is a progressive degenerative disease that usually occurs bilaterally and is characterized by corneal thinning and apical protrusion of the cornea. Oxidative stress is an indicator of the accumulation of reactive oxygen species (ROS), and KC keratocytes exhibit increased ROS production compared with that of normal keratocytes. Therefore, oxidative stress in KC keratocytes may play a major role in the development and progression of KC. Here, we investigated the protective effect of sulforaphane (SF) antioxidants using a hydrogel-simulated model of the cell mechanical microenvironment of KC. The stiffness of the KC matrix microenvironment in vitro was 16.70 kPa and the stiffness of the normal matrix microenvironment was 34.88 kPa. Human keratocytes (HKs) were cultured for 24 h before observation or drug treatment with H2O2 in the presence or absence of SF. The levels of oxidative stress, nuclear factor E2-related factor 2 (Nrf-2) and antioxidant response element (ARE) were detected. The high-stress state of HKs in the mechanical microenvironment of KC cells compensates for the activation of the Nrf-2/ARE signaling pathway. H2O2 leads to increased oxidative stress and decreased levels of antioxidant proteins in KC. In summary, SF can reduce endogenous and exogenous oxidative stress and increase the antioxidant capacity of cells.


Asunto(s)
Isotiocianatos , Queratocono , Sulfóxidos , Humanos , Queratocono/tratamiento farmacológico , Queratocono/metabolismo , Antioxidantes/metabolismo , Factor 2 Relacionado con NF-E2/metabolismo , Especies Reactivas de Oxígeno/metabolismo , Elementos de Respuesta Antioxidante , Peróxido de Hidrógeno/metabolismo , Córnea/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA