Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.264
Filtrar
1.
J Refract Surg ; 40(7): e445-e452, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39007818

RESUMEN

PURPOSE: To evaluate the repeatability of automatic measurements of a new anterior segment optical coherence tomographer (ANTERION; Heidelberg Engineering) and their agreement with an anterior segment optical coherence tomography device combined with Placido disc corneal topography (MS-39; CSO) in patients affected by keratoconus. METHODS: Fifty-four consecutive patients were included. Three measurements were performed with the ANTERION and one with the MS-39. Repeatability was assessed by means of within-subject standard deviation, coefficient of variation (CoV), and intraclass correlation coefficient (ICC). Agreement was investigated with the 95% limits of agreement. The paired t-test and Wilcoxon matched-pairs test were performed to compare the measurements of the different devices. RESULTS: Repeatability of ANTERION measurements was high, with an ICC greater than 0.98 for all parameters. Many parameters revealed a CoV of less than 1% and a CoV within 5% was obtained for astigmatism measurements. The ANTERION measured a significantly higher corneal power and the MS-39 more negative posterior keratometric values. These differences were mirrored by a moderate agreement for mean simulated keratometry and poor agreement for total corneal power and posterior keratometry. CONCLUSIONS: The ANTERION revealed high repeatability of automatic measurements and good agreement with the MS-39 for many parameters in patients affected by keratoconus, but for most parameters the two instruments cannot be considered interchangeable. [J Refract Surg. 2024;40(7):e445-e452.].


Asunto(s)
Segmento Anterior del Ojo , Topografía de la Córnea , Queratocono , Tomografía de Coherencia Óptica , Humanos , Queratocono/diagnóstico , Queratocono/fisiopatología , Tomografía de Coherencia Óptica/métodos , Reproducibilidad de los Resultados , Adulto , Topografía de la Córnea/métodos , Masculino , Femenino , Segmento Anterior del Ojo/diagnóstico por imagen , Adulto Joven , Biometría/instrumentación , Biometría/métodos , Estudios Prospectivos , Córnea/patología , Córnea/diagnóstico por imagen , Persona de Mediana Edad , Adolescente
2.
Vestn Oftalmol ; 140(3): 43-49, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38962978

RESUMEN

The combination of keratoconus (KC) with signs of dry eye disease (DES) has been described in numerous scientific publications. At the same time, there is a relationship between KC stage and an increase in the severity of DES symptoms, however, there is still no common understanding of the severity of xerotic process depending on the clinical course of keratectasia. PURPOSE: This study assesses the changes in the state of the precorneal tear film in KC relative to the stages of the disease. MATERIAL AND METHODS: The study included 50 patients (100 eyes) with bilateral non-operated KC from subclinical to stage IV. The following methods were used for a comprehensive assessment of the condition of the tear film: biomicroscopy of the anterior segment of the eye using vital dyes, functional tests (Norn, Schirmer, Jones tests), tearscopy of the lipid layer of the tear film with software processing of the results, OCT-meniscometry, as well as filling out the OSDI questionnaire by patients. RESULTS: The following significant changes were revealed as the KC stage progressed: an increase in the area of staining of the ocular surface with vital dyes, a decrease in the results of the Norn functional test and OCT-meniscometry, an increase in the areas of smaller thickness of lipids and areas of their complete absence according to tearscopy, as well as an increase in scores of the OSDI questionnaire. CONCLUSION: A comprehensive assessment of the condition of the tear film in KC indicates the relationship and the strengthening of the signs of DES as keratectasia progresses, and can be considered as justification for the need to prescribe tear replacement and reparative therapy that improves the condition of the ocular surface and stabilizes the precorneal tear film.


Asunto(s)
Síndromes de Ojo Seco , Queratocono , Lágrimas , Humanos , Queratocono/diagnóstico , Queratocono/fisiopatología , Lágrimas/metabolismo , Femenino , Masculino , Adulto , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/fisiopatología , Síndromes de Ojo Seco/etiología , Síndromes de Ojo Seco/metabolismo , Córnea , Índice de Severidad de la Enfermedad , Progresión de la Enfermedad , Tomografía de Coherencia Óptica/métodos
3.
BMC Ophthalmol ; 24(1): 288, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39014345

RESUMEN

BACKGROUND: Recently a new surgical technique for intracorneal ring-segments (ICRS) assisted by femtosecond laser (FSL) called ByLimB was developed, involving the creation of the incision from a paralimbic region. This study aims to evaluate the safety and efficacy of the ByLimb technique following one year of follow-up. METHODS: A prospective, single-center study was conducted at the Zaldivar Institute in Buenos Aires, Argentina. Keratoconus patients with indication for ICRS-FSL assisted procedure, operated with the ByLimb technique were included. By using the ByLimb technique, the ICRS are placed without affecting the tunnel's roof, and the end of the ICRS is always away from the incision area. Visual acuity, topographic astigmatism, and the occurrence of complications were evaluated. Safety index was the main outcome and efficacy indes was a complimentary outcome. RESULTS: A total of 17 eyes completed the 12-month follow-up period. The safety index was 1.10 (mean postoperative corrected distance visual acuity (CDVA) in decimal: 0.76/preoperative CDVA: 0.69), while the efficacy index was 0.89 (mean postoperative uncorrected distance visual acuity UDVA in decimal: 0.62/preoperative CDVA: 0.69). Mean preoperative astigmatism was 5.3 ± 2.3, decreasing twelve months after surgery at 2.1 ± 1.2 (p < 0.001). No eye loss lines of vision and no intraoperative complications were observed. During the first month after surgery, an improper positioning of the ICRS based on topographic assessment was detected in five cases. A second procedure was performed, which consisted of opening the incision and introducing a Sinsky hook, through which the ICRS was mobilized and placed in its correct position. No incisional alterations, signs of infection, anterior segment anomalies, or fundus alterations were observed. CONCLUSION: FSL-assisted ICRS implantation through the perilimbal region has demonstrated an adequate safety index one year post-surgery. Additionally, this technique has facilitated accurate realignment of ICRS during secondary surgical interventions within one-month post-surgery. While the current findings are promising, continued follow-up of these cases is warranted.


Asunto(s)
Topografía de la Córnea , Queratocono , Prótesis e Implantes , Implantación de Prótesis , Agudeza Visual , Humanos , Estudios Prospectivos , Queratocono/cirugía , Queratocono/fisiopatología , Femenino , Masculino , Adulto , Proyectos Piloto , Agudeza Visual/fisiología , Implantación de Prótesis/métodos , Adulto Joven , Sustancia Propia/cirugía , Estudios de Seguimiento , Refracción Ocular/fisiología , Persona de Mediana Edad , Terapia por Láser/métodos , Resultado del Tratamiento
6.
J Refract Surg ; 40(6): e392-e397, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38848056

RESUMEN

PURPOSE: To compare the effects of corneal allogenic intrastromal ring segment (CAIRS) implantation on topographical measurements and visual outcomes of patients with keratoconus with and without corneal cross-linking (CXL) prior to the time of implantation. METHODS: Sixty-seven eyes with corneal allograft intrastromal ring segment implantation (KeraNatural; Lions VisionGift) due to advanced keratoconus were included in the study. Thirty-seven eyes had no CXL and 30 eyes had had CXL before being referred to the authors. The changes in spherical equivalent (SE), uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), steep keratometry (K1), flat keratometry (K2), mean keratometry (Kmean), maximum keratometry (Kmax), and thinnest pachymetry were retrospectively analyzed 6 months after the implantation. RESULTS: The median age was 29 years in the CXL group and 24.0 years in the non-CXL group (P > .05), respectively. All topographical and visual parameters before implantation were similar in both groups (P > .05 for all parameters). At 6 months, CDVA, K1, and Kmean showed higher improvement in the non-CXL group than the CXL group (P = .030, .018, and .039, respectively). CONCLUSIONS: CAIRS surgery has a flattening effect on both the corneas with and without CXL. The cornea with prior CXL treatment had less flattening effect due to the stiffening effect of prior CXL. [J Refract Surg. 2024;40(6):e392-e397.].


Asunto(s)
Colágeno , Sustancia Propia , Topografía de la Córnea , Reactivos de Enlaces Cruzados , Queratocono , Fármacos Fotosensibilizantes , Prótesis e Implantes , Implantación de Prótesis , Refracción Ocular , Agudeza Visual , Humanos , Queratocono/fisiopatología , Queratocono/metabolismo , Queratocono/tratamiento farmacológico , Queratocono/cirugía , Sustancia Propia/metabolismo , Sustancia Propia/cirugía , Reactivos de Enlaces Cruzados/uso terapéutico , Agudeza Visual/fisiología , Adulto , Masculino , Femenino , Fármacos Fotosensibilizantes/uso terapéutico , Estudios Retrospectivos , Adulto Joven , Refracción Ocular/fisiología , Colágeno/metabolismo , Paquimetría Corneal , Riboflavina/uso terapéutico , Fotoquimioterapia/métodos , Adolescente , Rayos Ultravioleta , Trasplante de Córnea/métodos , Persona de Mediana Edad , Reticulación Corneal
7.
Int Ophthalmol ; 44(1): 294, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38943020

RESUMEN

PURPOSE: To investigate the clinical significance of the correlation between optical densitometry and both biomechanical and morphological parameters in keratoconus (KC) and to verify the diagnostic value of optical densitometry in KC. METHOD: This cross-sectional study included 436 eyes of 295 patients with KC. Corneal optical densitometry, morphological parameters and biomechanical parameters were measured. Spearman's correlation analysis was employed to investigate the association between optical densitometry and both biomechanical and morphological parameters. RESULT: Optical densitometry of the anterior (0-2 mm and 2-6 mm), central (0-2 mm), posterior (2-6 mm) and total (2-6 mm) layers correlated positively with SPA1, while the posterior layer (0-2 mm) correlated negatively. Optical densitometry of the anterior layers 2-6 mm, 6-10 mm, and the central layer 6-10 mm negatively affected AL1, while the posterior layer 0-2 mm positively affected it. Optical densitometry of the anterior, central, and posterior layers 0-2 mm and 2-6 mm positively influenced the morphological parameters K1F, K2F, KmF and the absolute values of K1B, K2B, KmB. Optical densitometry of the center (0-2 mm) and posterior (2-6 mm) layers negatively influenced TCT. Optical densitometry of the anterior (0-2 mm and 2-6 mm), center (0-2 mm), posterior (2-6 mm) and total (2-6 mm) layers correlated positively with ACE and PCE, whereas the posterior layer (0-2 mm) correlated negatively. CONCLUSION: Optical densitometry was correlated with biomechanical and morphological parameters in keratoconus, suggesting its potential as a diagnostic indicator for assessing keratoconus progression and treatment efficacy.


Asunto(s)
Córnea , Topografía de la Córnea , Densitometría , Queratocono , Humanos , Queratocono/diagnóstico , Queratocono/fisiopatología , Estudios Transversales , Femenino , Densitometría/métodos , Masculino , Córnea/diagnóstico por imagen , Córnea/patología , Adulto , Topografía de la Córnea/métodos , Adulto Joven , Adolescente , Persona de Mediana Edad , Fenómenos Biomecánicos
8.
BMC Ophthalmol ; 24(1): 201, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38698363

RESUMEN

BACKGROUND: We aimed to employ Optical Coherence Tomography Angiography (OCTA) to comprehensively assess changes in the optic nerve head (ONH) and macular perfusion before and after the Corneal Collagen Cross-Linking (CCL) procedure in patients with keratoconus. METHODS: A total of 22 keratoconus patient's candidate for CCL procedures were included based on specific criteria, with meticulous exclusion criteria in place to minimize potential confounders. Participants underwent OCTA assessments of the ONH and macula using the Spectralis OCT (Heidelberg) before CCL, as well as at 1- and 3-months post-CCL. MATLAB software was utilized for image analysis. RESULTS: The mean age of the participants was 20.09 ± 6.11, including 59% male, and the mean intraocular pressure (IOP) before the surgery was 13.59 ± 2.85 mmHg. Peripapillary Retinal nerve fiber layer (ppRNFL) thickness and overall retinal thickness remained stable post-CCL. However, significant alterations were observed in macular vessel density, emphasizing regional variations in vascular response. For macular large vessel density (LVD), both superficial and deep vascular complex (SVC and DVC) demonstrated significant differences between before surgery and the 3 months post-surgery follow-up (p < 0.001 and p = 0.002, respectively). Optic nerve head markers demonstrated relative stability, except for changes in avascular complex density, which was 49.2 ± 2.2% before the surgery and decrease to 47.6 ± 1.7% three months after the operation (P-value = 0.005). CONCLUSION: While CCL appears to maintain the integrity of certain ocular structures, alterations in macular perfusion post-CCL suggest potential effects on retinal blood supply. Long-term monitoring is crucial to understand the implications of these changes, particularly in the context of conditions such as diabetes.


Asunto(s)
Colágeno , Reactivos de Enlaces Cruzados , Angiografía con Fluoresceína , Queratocono , Disco Óptico , Vasos Retinianos , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Queratocono/fisiopatología , Queratocono/diagnóstico , Masculino , Femenino , Colágeno/metabolismo , Adulto Joven , Adulto , Angiografía con Fluoresceína/métodos , Vasos Retinianos/diagnóstico por imagen , Vasos Retinianos/fisiopatología , Disco Óptico/irrigación sanguínea , Adolescente , Estudios Prospectivos , Fármacos Fotosensibilizantes/uso terapéutico , Fotoquimioterapia/métodos , Mácula Lútea/diagnóstico por imagen , Mácula Lútea/irrigación sanguínea
9.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38742501

RESUMEN

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Asunto(s)
Lentes de Contacto , Queratocono , Esclerótica , Agudeza Visual , Humanos , Queratocono/cirugía , Queratocono/diagnóstico , Queratocono/fisiopatología , Queratocono/terapia , Femenino , Masculino , Adulto , Esclerótica/cirugía , Implantación de Prótesis/métodos , Implantación de Prótesis/instrumentación , Resultado del Tratamiento , Topografía de la Córnea , Prótesis e Implantes , Adulto Joven , Ajuste de Prótesis/métodos , Adolescente , Sustancia Propia/cirugía
10.
Curr Opin Ophthalmol ; 35(4): 315-321, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38700950

RESUMEN

PURPOSE OF REVIEW: This manuscript summarizes contemporary research from 2018 to 2023 evaluating long-term (≥2 years) outcomes of corneal crosslinking (CXL) for progressive keratoconus (KCN). RECENT FINDINGS: The standard Dresden protocol (SDP) has been utilized clinically since the early 2000 s to treat ectatic disorders, primarily progressive KCN and postrefractive ectasia. Various modifications have since been introduced including accelerated and transepithelial protocols, which are aimed at improving outcomes or reducing complications. This review summarizes data demonstrating that the SDP halts disease progression and improves various visual and topographic indices (UDVA, CDVA, Kmax, K1, K2) up to 13 years postoperatively. Accelerated and transepithelial protocols have been found to be well tolerated alternatives to SDP with similar efficacy profiles. Studies focusing on pediatric populations identified overall higher progression rates after CXL. All protocols reviewed had excellent safety outcomes in adults and children. SUMMARY: Recent studies revealed that SDP successfully stabilizes KCN long term, and a variety of newer protocols are also effective. Pediatric patients may exhibit higher progression rates after CXL. Further research is required to enhance the efficacy and ease of these protocols.


Asunto(s)
Colágeno , Reactivos de Enlaces Cruzados , Queratocono , Fotoquimioterapia , Fármacos Fotosensibilizantes , Riboflavina , Agudeza Visual , Humanos , Queratocono/tratamiento farmacológico , Queratocono/fisiopatología , Reactivos de Enlaces Cruzados/uso terapéutico , Fármacos Fotosensibilizantes/uso terapéutico , Riboflavina/uso terapéutico , Fotoquimioterapia/métodos , Colágeno/uso terapéutico , Agudeza Visual/fisiología , Rayos Ultravioleta , Sustancia Propia/metabolismo , Sustancia Propia/efectos de los fármacos , Resultado del Tratamiento , Topografía de la Córnea
11.
Ophthalmic Physiol Opt ; 44(5): 884-893, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38778634

RESUMEN

INTRODUCTION: Soft contact lenses may be a good alternative for early-stage keratoconus (KC) patients who do not tolerate rigid gas permeable (RGP) lenses due to ocular discomfort or complications. This prospective study compared outcomes obtained after 2 weeks of wearing two types of soft silicone hydrogel contact lenses for keratoconus that varied in their diameter and central thickness (cc). METHODS: Patients with Amsler-Krumeich grades I or II KC were fitted with small-diameter (14.2 or 14.8 mm) SoftK (SD-SoftK, cc = 0.48 mm) and large-diameter (17 mm) SoftK (LD-SoftK, cc = 0.60 mm) lenses, each worn for 2 weeks in a crossover design. Low (10%;10VA) and high (100%;100VA) contrast visual acuity, contrast sensitivity (CS, Pelli-Robson), higher order aberrations (HOAs, Visionix Vx130), the number of trial lens modifications during fitting and the subjectively preferred lens were compared using Friedman tests with post-hoc analysis. RESULTS: Forty eyes (N = 20, 10 males, mean age: 39.0 ± 9.9 years, range: 23-55 years) were examined. Their habitual median (interquartile1, interquartile3) 10VA (LogMAR), 100VA (LogMAR) and CS (LogCS) were 0.52 (0.30, 0.50), 0.14 (0.10, 0.15) and 1.35 (1.35, 1.50), respectively. For the SD-SoftK condition, the values were 0.23 (0.17, 0.30), 0.02 (0.00, 0.05) and 1.50 (1.50, 1.65), respectively. For the LD-SoftK condition, the respective values were 0.36 (0.27, 0.44), 0.09 (0.05, 0.13) and 1.50 (1.50, 1.60). SD-SoftK lenses significantly improved 10VA compared with habitual and LD-SoftK. SD-SoftK also significantly improved CS compared with habitual, but not LD-SoftK. LD-SoftK significantly improved spherical aberration compared with uncorrected (0.03 ± 0.10 µ vs. 0.07 ± 0.13 µ) but not SD-SoftK (0.04 ± 0.07 µ). Both lenses required a mean of 1.5 modifications prior to final lens fitting. Fewer adverse events were seen with SD-SoftK (N = 3) compared with LD-SoftK (N = 8), and 75% of participants preferred SD-SoftK lenses. CONCLUSION: SD-SoftK lenses were preferred by 75% of subjects, were associated with fewer adverse events and significantly improved 10VA compared with LD-SoftK lenses. SD-SoftK lenses also significantly improved CS compared with the habitual correction, but this did not differ significantly from the LD-SoftK lenses.


Asunto(s)
Lentes de Contacto Hidrofílicos , Sensibilidad de Contraste , Topografía de la Córnea , Estudios Cruzados , Queratocono , Agudeza Visual , Humanos , Queratocono/diagnóstico , Queratocono/fisiopatología , Queratocono/terapia , Masculino , Femenino , Estudios Prospectivos , Adulto , Agudeza Visual/fisiología , Adulto Joven , Sensibilidad de Contraste/fisiología , Topografía de la Córnea/métodos , Persona de Mediana Edad , Diseño de Equipo , Refracción Ocular/fisiología
12.
Indian J Ophthalmol ; 72(Suppl 4): S639-S644, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38767551

RESUMEN

PURPOSE: This study aimed to report the long-term results of combined topography-guided photorefractive keratectomy (PRK) and accelerated corneal collagen cross-linking (CXL) for keratoconus using the Zeiss refractive coordinated system. METHODS: A prospective interventional study was conducted in a tertiary eye care hospital in South India. Patients with mild-to-moderate progressive keratoconus and corneal pachymetry greater than 450 µm were included. They underwent customized topography-guided PRK followed by CXL. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and keratometry readings and complications were evaluated at 1, 3, 6, 12, and 24 months postoperatively. RESULTS: Thirty patients (30 eyes) were included in the study. All study parameters showed a statistically significant improvement postoperatively over baseline values. At 24 months, the mean UDVA improved from 0.8 ± 0.180 logarithm of the minimum angle of resolution (logMAR) to 0.38 ± 0.118 logMAR ( P -value <0.001) and CDVA improved from 0.467 ± 0.142 logMAR to 0.227 ± 0.078 logMAR ( P -value <0.001). The mean flat, steep, and maximum keratometry values were significantly reduced by 2.133, 3, and 4.54 diopters, respectively, at the last follow-up examination ( P -value <0.001). CONCLUSION: The combined topography-guided PRK and accelerated CXL procedure seem to be a promising treatment alternative for early keratoconus. This is the first such study on the Zeiss refractive coordinated system. However, further studies with a larger study population and longer follow-up periods are required to draw final conclusions about the benefits of this procedure in keratoconus.


Asunto(s)
Colágeno , Topografía de la Córnea , Reactivos de Enlaces Cruzados , Queratocono , Fotoquimioterapia , Queratectomía Fotorrefractiva , Fármacos Fotosensibilizantes , Refracción Ocular , Riboflavina , Agudeza Visual , Humanos , Queratectomía Fotorrefractiva/métodos , Queratocono/cirugía , Queratocono/diagnóstico , Queratocono/tratamiento farmacológico , Queratocono/fisiopatología , Queratocono/metabolismo , Masculino , Estudios Prospectivos , Femenino , Fármacos Fotosensibilizantes/uso terapéutico , Colágeno/metabolismo , Reactivos de Enlaces Cruzados/uso terapéutico , Agudeza Visual/fisiología , Adulto , Adulto Joven , Fotoquimioterapia/métodos , Riboflavina/uso terapéutico , Refracción Ocular/fisiología , Estudios de Seguimiento , Láseres de Excímeros/uso terapéutico , Rayos Ultravioleta , Cirugía Asistida por Computador/métodos , Córnea/cirugía , Córnea/patología , Adolescente , Sustancia Propia/metabolismo , Sustancia Propia/cirugía , Resultado del Tratamiento , Terapia Combinada
13.
Indian J Ophthalmol ; 72(Suppl 3): S495-S500, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38648457

RESUMEN

PURPOSE: This retrospective longitudinal study evaluated the biomechanical E-staging in KC corneas before and after intracorneal ring segment (ICRS) implantation (Intacs® SK, Addition Technology, Illinois, United States). METHODS: Biomechanical E-staging for ectatic corneal diseases was applied retrospectively on 49 KC corneas of 41 patients who underwent ICRS implantation. The main outcome parameters included the Corvis Biomechanical Factor (CBiF, the linearized Corvis Biomechanical Index and the biomechanical parameters included), the resulting biomechanical E-staging, the stress-strain index, thinnest corneal thickness (TCT), maximal anterior keratometry (Kmax), and the anterior radius of curvature (ARC). They were evaluated at 1.9 ± 1.1 months preoperatively and postoperatively after 2.8 ± 0.7, 5.8 ± 1.0, and 10.6 ± 2.3 months. RESULTS: The CBiF decreased (4.9 ± 0.5 | 4.7 ± 0.5, P = 0.0013), and the E-staging increased significantly (2.8 ± 0.8 | 3.1 ± 0.9, P = 0.0012, paired t-test) from preoperatively to the first postoperative follow-up. The difference remained significant after 6 months; however, there was no more difference after 11 months. TCT was stable, whereas Kmax and ARC significantly decreased after ICRS implantation (TCT: 464 ± 49, 470 ± 51, 467 ± 38, 461 ± 48; Kmax: 56.3 ± 4.5, 54.7 ± 4.5, 54.2 ± 4.8, 54.1 ± 4.3; ARC: 51.5 ± 3.4, 48.3 ± 3.8, 48.6 ± 3.0, 48.6 ± 3.2 preoperatively and 3, 6, and 11 months postoperatively, respectively). Besides Kmax and ARC, Ambrósio's relational thickness to the horizontal profile (ARTh) was the only parameter that was significantly lower than preoperatively at any follow-up (P ≤ 0.0024, Wilcoxon matched-pairs test). CONCLUSION: Intacs® SK implantation results in an increasing biomechanical E-staging in the first postoperative months with stabilization near preoperative values after 1 year. Significantly lower ARTh values at any follow-up document the ICRS effect and contribute to a slightly higher postoperative biomechanical E-staging value.


Asunto(s)
Córnea , Sustancia Propia , Topografía de la Córnea , Queratocono , Prótesis e Implantes , Implantación de Prótesis , Agudeza Visual , Humanos , Queratocono/cirugía , Queratocono/diagnóstico , Queratocono/fisiopatología , Estudios Retrospectivos , Femenino , Masculino , Adulto , Implantación de Prótesis/métodos , Córnea/patología , Estudios de Seguimiento , Sustancia Propia/patología , Sustancia Propia/cirugía , Agudeza Visual/fisiología , Fenómenos Biomecánicos , Adulto Joven , Persona de Mediana Edad , Refracción Ocular/fisiología , Diseño de Prótesis , Adolescente
14.
Jpn J Ophthalmol ; 68(3): 225-232, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38557918

RESUMEN

PURPOSE: We aimed to compare the efficacy and safety of accelerated contact lens-assisted cross-linking (CA-CXL) with Lotrafilcon B and Comfilcon A lenses in keratoconus (KC) patients with thin corneas. STUDY DESIGN: Retrospective, single-center study. MATERIALS AND METHODS: We retrospectively included 51 eyes of 39 KC patients with corneal thickness <400µm after epithelial scraping (Epi-off), who underwent accelerated CA-CXL treatment with Lotrafilcon B (n=20) and Comfilcon A (n=31). Uncorrected and corrected distance visual acuity (UDVA and CDVA), manifest refraction values, corneal topographic data and endothelial cell density were recorded at preoperative and postoperative 1st, 3rd and 6th month controls. RESULTS: CDVA in the Comfilcon A group was higher than CDVA before surgery at 6 months postoperatively (p<0.001). When the two lenses were compared, CDVA was found to be significantly higher in the Lotrafilcon B group in the preoperative, postoperative 1st month and 3rd month values, but there was no significant difference between the postoperative 6th month values (p=0.028, p=0.018, p=0.044, p=0.181, respectively). The maximum keratometry (Kmax) value at the 6th month after surgery in the Comfilcon A group was significantly lower than in the Lotrafilcon B group (p=0,009). There was no significant difference between the endothelial cell density values between the groups (p=0.623, p=0.609, p=0.794, p=0.458, respectively). There was no significant difference between the progression, regression, and stability rates of the two groups (p=0.714). CONCLUSIONS: Accelerated CA-CXL with Lotrafilcon B and Comfilcon A silicone hydrogel lenses is a safe and effective method to stop progression in patients with thin corneas.


Asunto(s)
Colágeno , Topografía de la Córnea , Reactivos de Enlaces Cruzados , Queratocono , Fotoquimioterapia , Fármacos Fotosensibilizantes , Refracción Ocular , Riboflavina , Agudeza Visual , Humanos , Queratocono/diagnóstico , Queratocono/fisiopatología , Queratocono/tratamiento farmacológico , Queratocono/terapia , Queratocono/metabolismo , Femenino , Masculino , Estudios Retrospectivos , Agudeza Visual/fisiología , Fármacos Fotosensibilizantes/uso terapéutico , Adulto , Riboflavina/uso terapéutico , Fotoquimioterapia/métodos , Adulto Joven , Refracción Ocular/fisiología , Colágeno/metabolismo , Resultado del Tratamiento , Córnea/patología , Rayos Ultravioleta , Estudios de Seguimiento , Adolescente , Recuento de Células , Sustancia Propia/metabolismo , Endotelio Corneal/patología , Lentes de Contacto Hidrofílicos , Reticulación Corneal
15.
Eye Contact Lens ; 50(6): 255-258, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38652487

RESUMEN

OBJECTIVE: To evaluate the effects of rigid corneal lenses (RCL) in patients with keratoconus, based on eccentricity. METHODS: Eighty-four eyes from 84 patients were included in this retrospective comparative study. Based on the median value of eccentricity difference between the cornea and back surface of the RCL, the patients were divided into groups 1 (<0.08) and 2 (≥0.08). Visual acuity, refractive index, and corneal topography indices were compared before and three months after lens use. RESULTS: Visual acuity, astigmatism, refractive error, corneal curvature, and corneal thickness improved significantly in both groups. Apical power and anterior elevation improved significantly in group 1, with small differences in eccentricity, but not in group 2. Changes in apical power before and after lens use were significantly different between the two groups. CONCLUSION: The RCL was effective for the cornea of keratoconus, especially when the prescription was made with a small difference in eccentricity.


Asunto(s)
Lentes de Contacto , Córnea , Topografía de la Córnea , Queratocono , Refracción Ocular , Agudeza Visual , Humanos , Queratocono/fisiopatología , Queratocono/terapia , Estudios Retrospectivos , Agudeza Visual/fisiología , Femenino , Masculino , Adulto , Refracción Ocular/fisiología , Adulto Joven , Córnea/patología , Córnea/fisiopatología , Adolescente , Astigmatismo/fisiopatología , Astigmatismo/terapia , Persona de Mediana Edad
16.
Arq Bras Oftalmol ; 87(4): e2023, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38656029

RESUMEN

PURPOSE: To assess the outcomes of deep anterior lamellar keratoplasty or penetrating keratoplasty at the scar and the edema stages. METHODS: Forty-five patients (45 eyes) with keratoconus scar stage (scar group, n=26; penetrating keratoplasty a subgroup, n=7; deep anterior lamellar keratoplasty b subgroup, n=19) and keratoconus edema stage (edema group, n=19; penetrating keratoplasty c subgroup, n=12; deep anterior lamellar keratoplasty d group, n=7) who received penetrating keratoplasty or deep anterior lamellar keratoplasty from 2000 to 2022 were retrospectively studied. At 1, 6, and 12 months after surgery, the best-corrected visual acuity, astigmatism, spherical equivalent, corneal endothelial cell density, and complications were analyzed. RESULTS: The best-corrected visual acuity and average corneal endothelial cell loss rate were not significantly different between the scar and edema groups (p>0.05). At 6 and 12 months after surgery, the astigmatism and spherical equivalent in the scar group were significantly lower than those in the edema group (p<0.05). The spherical equivalent of the deep anterior lamellar keratoplasty b subgroup was lower than that of the penetrating keratoplasty a subgroup in the scar group 6 months after surgery (p<0.05). In the edema group, there was no significant difference in spherical equivalent between subgroups (p>0.05). There were no significant differences in best-corrected visual acuity and astigmatism between subgroups within the two groups (p>0.05). In comparison to the scar group, the edema group experienced more complications. According to a survival analysis, there was no statistically significant difference between the scar group and the edema group regarding the progression of vision. CONCLUSIONS: In terms of the outcomes and prognosis for vision after keratoplasty with edema stage and scar stage, deep anterior lamellar keratoplasty may be as effective as penetrating keratoplasty.


Asunto(s)
Cicatriz , Edema Corneal , Queratocono , Queratoplastia Penetrante , Agudeza Visual , Humanos , Queratocono/cirugía , Queratocono/complicaciones , Queratocono/fisiopatología , Masculino , Femenino , Estudios Retrospectivos , Queratoplastia Penetrante/métodos , Adulto , Cicatriz/etiología , Resultado del Tratamiento , Edema Corneal/cirugía , Edema Corneal/etiología , Adulto Joven , Trasplante de Córnea/métodos , Factores de Tiempo , Adolescente , Astigmatismo/cirugía , Astigmatismo/fisiopatología , Persona de Mediana Edad , Complicaciones Posoperatorias , Recuento de Células , Endotelio Corneal/patología , Endotelio Corneal/cirugía
17.
Indian J Ophthalmol ; 72(5): 712-717, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38648433

RESUMEN

PURPOSE: To compare the changes encountered in corneal biomechanics and aberration profile following accelerated corneal collagen cross-linking (CXL) using hypo-osmolar and iso-osmolar riboflavin in corneal thicknesses of <400 and >400 microns, respectively. METHODS: This is a prospective, interventional, comparative study involving 100 eyes of 75 patients with progressive keratoconus. Eyes were divided into two groups based on corneal thickness: group 1 included eyes with a corneal thickness of <400 microns who underwent hypo-osmolar CXL, and group 2 included eyes with a corneal thickness of >400 microns who underwent iso-osmolar CXL. Corneal biomechanical and aberration profiles were evaluated and compared between groups. RESULTS: In group 1, all higher-order aberrations (HOA) except secondary astigmatism significantly decreased from baseline; however, in group 2, only coma and trefoil decreased. The corneal resistance factor and corneal hysteresis significantly improved in both groups, which was significantly greater in group 2 than in group 1. The change in inverse radius, deformation amplitude, and tomographic biomechanical index was significantly improved in group 2 as compared to group 1. CONCLUSION: Improvement in corrected distance visual acuity and decrease in HOA were significantly better in the hypo-osmolar CXL group; however, the improvement in biomechanical strength of the cornea was significantly better in the iso-osmolar group.


Asunto(s)
Colágeno , Córnea , Topografía de la Córnea , Reactivos de Enlaces Cruzados , Queratocono , Fármacos Fotosensibilizantes , Riboflavina , Rayos Ultravioleta , Agudeza Visual , Adolescente , Adulto , Femenino , Humanos , Masculino , Adulto Joven , Fenómenos Biomecánicos , Colágeno/metabolismo , Córnea/diagnóstico por imagen , Córnea/fisiopatología , Córnea/efectos de los fármacos , Sustancia Propia/metabolismo , Sustancia Propia/efectos de los fármacos , Aberración de Frente de Onda Corneal/fisiopatología , Reactivos de Enlaces Cruzados/uso terapéutico , Estudios de Seguimiento , Queratocono/tratamiento farmacológico , Queratocono/fisiopatología , Queratocono/diagnóstico , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/uso terapéutico , Estudios Prospectivos , Refracción Ocular/fisiología , Riboflavina/uso terapéutico , Agudeza Visual/fisiología , Niño
18.
Cont Lens Anterior Eye ; 47(3): 102132, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38462405

RESUMEN

PURPOSE: To determine central and peripheral corneal sagittal height (z) values in keratoconus and healthy eyes with the Oculus Pentacam point-by-point data extraction software. METHODS: Forty eyes from patients with central or paracentral (4 mm) keratoconus (32.0 ± 12.5 years) and 40 eyes from healthy subjects (29.1 ± 7.9 years) were included. The Oculus Pentacam software was employed to determine z values referenced to a plane tangent to the corneal apex for five circles concentric with the centre of the pupil with diameters 4, 6, 8, 9 and 10.5 mm. The variability in z values within each circle and in terms of corneal meridians and quadrants was explored in keratoconus and healthy eyes. RESULTS: Keratoconus apex was mainly located at the inferior-temporal quadrant, at a distance from 0.083 mm to 3.59 mm with reference to the centre of the pupil. Mean z was larger in keratoconus than in healthy eyes in all explored corneal diameters (all p < 0.001). Variation in z values was larger in keratoconus than healthy eyes only at the central areas of the cornea (4 mm, p = 0.02; 6 mm, p = 0.011), but not in the periphery (8, 9 and 10.5 mm). In keratoconus, the frequency of minimum z values in the IT quadrant was greater than in healthy eyes. CONCLUSION: Although peripheral z values were larger in keratoconus, rotational variations were comparable between keratoconus and healthy eyes, suggesting that large diameter spherical rigid corneal contact lenses may be an alternative to scleral lenses in central and paracentral keratoconus.


Asunto(s)
Córnea , Topografía de la Córnea , Queratocono , Humanos , Queratocono/fisiopatología , Queratocono/diagnóstico , Adulto , Femenino , Masculino , Córnea/patología , Adulto Joven , Persona de Mediana Edad , Voluntarios Sanos , Adolescente
19.
Cont Lens Anterior Eye ; 47(3): 102145, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38472013

RESUMEN

PURPOSE: To report a case of ulcerative keratopathy following implantation of acellular porcine corneal stroma (APCS) in a patient with keratoconus (KC). METHODS: A 58 year-old patient initially presented with an ulcerative keratopathy in the left eye. Previously, several corneal procedures (including radial keratotomy, laser-in-situ keratomileusis, crosslinking) were performed for KC. Eight months ago, an APCS lenticule (Xenia corneal implant, Gebauer Medizintechnik GmbH, Neuhausen, Germany) was implanted into a stromal pocket because of progressive keratectasia. Visual acuity was hand movement. Anterior segment optical coherence tomography showed a space between the APCS lenticule and the host stroma. Excimer laser-assisted penetrating keratoplasty (PKP, 8.0/8.1 mm) was performed in the left eye. The corneal explant was investigated by light and transmission electron microscopy. RESULTS: Best-corrected visual acuity was 20/40 six weeks after PKP. Light microscopy demonstrated a stromal ulceration down to the APCS lenticule. No stromal cells could be found within the APCS lenticule eight months after implantation. The APCS lenticule did not show a green stain of the collagens with Masson-Goldner staining and exhibited a strong Periodic acid-Schiff positive reaction. Electron microscopy of the APCS lenticule revealed cross-linked collagen lamellae without cellular components. Close to the interface, corneal collagen lamellae of the host cornea were disorganized. Few vital keratocytes were present on the surface of the lenticule and appeared to cause mechanical disruption of the host stroma along the lenticule-stroma interface. CONCLUSION: APCS implantation may lead to severe complications such as ulcerative keratopathy in otherwise uncomplicated KC corneas. In such cases, excimer laser-assisted PKP or Deep Anterior Lamellar Keratoplasty are the methods of choice to restore visual acuity.


Asunto(s)
Sustancia Propia , Úlcera de la Córnea , Queratocono , Agudeza Visual , Queratocono/cirugía , Queratocono/fisiopatología , Humanos , Sustancia Propia/cirugía , Sustancia Propia/patología , Persona de Mediana Edad , Animales , Porcinos , Agudeza Visual/fisiología , Úlcera de la Córnea/cirugía , Úlcera de la Córnea/etiología , Úlcera de la Córnea/diagnóstico , Masculino , Tomografía de Coherencia Óptica , Queratoplastia Penetrante , Topografía de la Córnea
20.
J Cataract Refract Surg ; 50(7): 746-753, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38465837

RESUMEN

PURPOSE: To compare clinical outcomes of customized transepithelial (epi-on) corneal crosslinking (CXL) in high oxygen and customized CXL with epithelial removal (epi-off) in room air for keratoconus (KC). SETTING: Umeå University Hospital, Umeå, Sweden. DESIGN: Prospective, randomized, single-masked, intraindividually comparing study. METHODS: 32 participants with bilateral progressive KC were treated with bilateral customized topography-guided CXL, 30 mW/cm 2 ; 7.2 to 15 J/cm 2 and were randomized to epi-on in one eye (32 eyes) and epi-off in the fellow eye (32 eyes). Uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), maximal keratometry (Kmax), subjective ocular discomfort, low-contrast visual acuities (LCVAs) at 10% and 2.5% contrast, ocular and anterior corneal wavefront aberrations, manifest refractive spherical equivalent, endothelial cell count (ECC), and adverse events were assessed through 24 months. RESULTS: Both treatments showed improvements at 24 months in UDVA; -0.16 ± 0.24 ( P < .001) and -0.13 ± 0.20 logMAR ( P = .006), respectively, CDVA; -0.10 ± 0.11 ( P < .001) and -0.10 ± 0.12 ( P = .001), Kmax; -1.74 ± 1.31 ( P < .001) and -1.72 ± 1.36 D ( P < .001). LCVA 10% improved for both protocols ( P < .001), but LCVA 2.5% improved for epi-on CXL only ( P = .001). ECC was unaltered, and no adverse events occurred. The epi-on eyes had significantly less discomfort symptoms during the whole first week posttreatment ( P < .05). CONCLUSIONS: High-oxygen customized epi-on CXL is a viable alternative to room air customized epi-off CXL, with faster improvements in CDVA and LCVA and less early ocular discomfort.


Asunto(s)
Colágeno , Topografía de la Córnea , Reactivos de Enlaces Cruzados , Queratocono , Fotoquimioterapia , Fármacos Fotosensibilizantes , Refracción Ocular , Riboflavina , Rayos Ultravioleta , Agudeza Visual , Humanos , Queratocono/tratamiento farmacológico , Queratocono/fisiopatología , Queratocono/metabolismo , Agudeza Visual/fisiología , Estudios Prospectivos , Reactivos de Enlaces Cruzados/uso terapéutico , Fármacos Fotosensibilizantes/uso terapéutico , Riboflavina/uso terapéutico , Masculino , Fotoquimioterapia/métodos , Femenino , Adulto , Colágeno/metabolismo , Adulto Joven , Refracción Ocular/fisiología , Método Simple Ciego , Oxígeno , Sustancia Propia/metabolismo , Aire , Endotelio Corneal/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA