Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.964
Filtrar
1.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38742501

RESUMEN

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Asunto(s)
Lentes de Contacto , Queratocono , Esclerótica , Agudeza Visual , Humanos , Queratocono/cirugía , Queratocono/diagnóstico , Queratocono/fisiopatología , Queratocono/terapia , Femenino , Masculino , Adulto , Esclerótica/cirugía , Implantación de Prótesis/métodos , Implantación de Prótesis/instrumentación , Resultado del Tratamiento , Topografía de la Córnea , Prótesis e Implantes , Adulto Joven , Ajuste de Prótesis/métodos , Adolescente , Sustancia Propia/cirugía
2.
BMC Ophthalmol ; 24(1): 211, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38741093

RESUMEN

OBJECTIVE: To investigate the correlation between higher-order aberrations (HOA) after small incision lenticule extraction (SMILE) and the severity of myopia and astigmatism, along with the relevant factors. These findings will provide valuable insights for decreasing the occurrence of HOA after SMILE and enhancing visual quality. METHODS: A total of 75 patients (150 eyes) with myopia and astigmatism who underwent SMILE were categorized into four groups based on the severity of myopia and astigmatism: Myopia Group 1 (Group M1, spherical diopter ranged from -1.00 D to -4.00 D), Myopia Group 2 (Group M2, spherical diopter ranged from -4.10 D to -10.00 D), Astigmatism Group 1 (Group A1, cylindrical diopter ranged from 0 D to -1.00 D), and Astigmatism Group 2 (Group A2, cylindrical diopter ranged from -1.10 D to -3.00 D). A comprehensive assessment was performed to examine the association between HOA and various relevant factors, including a detailed analysis of the subgroups. RESULTS: Group M1 had significantly lower levels of total eye coma aberration (CA), corneal total HOA (tHOA), internal tHOA, and vertical CA ( Z 3 - 1 ) after SMILE than Group M2 (P < 0.05). Similarly, Group A1 had significantly lower levels of total eye tHOA, CA, trefoil aberration (TA), corneal tHOA, TA, and vertical TA ( Z 3 - 3 ) after SMILE than Group A2 (P < 0.05). Pearson correlation analysis indicated a statistically significant positive relationship between the severity of myopia/astigmatism and most HOA (P < 0.05). Subgroup evaluations demonstrated a notable increase in postoperative HOA associated with myopia and astigmatism in Groups M2 and A2 compared with the control group. Lenticule thickness, postoperative central corneal thickness (CCT), postoperative uncorrected distance visual acuity (UDVA), and postoperative corneal Km and Cyl were strongly correlated with most HOA. Age, eyes, and postoperative intraocular pressure (IOP) were only associated with specific HOA. CONCLUSION: HOA positively correlated with the severity of myopia and astigmatism after SMILE. However, this relationship was not linear. HOA after SMILE was influenced by various factors, and additional specialized investigations are required to establish its clinical importance.


Asunto(s)
Astigmatismo , Cirugía Laser de Córnea , Aberración de Frente de Onda Corneal , Miopía , Refracción Ocular , Agudeza Visual , Humanos , Miopía/cirugía , Miopía/fisiopatología , Astigmatismo/fisiopatología , Astigmatismo/etiología , Masculino , Femenino , Adulto , Agudeza Visual/fisiología , Cirugía Laser de Córnea/métodos , Cirugía Laser de Córnea/efectos adversos , Aberración de Frente de Onda Corneal/fisiopatología , Aberración de Frente de Onda Corneal/etiología , Adulto Joven , Refracción Ocular/fisiología , Sustancia Propia/cirugía , Estudios Retrospectivos , Láseres de Excímeros/uso terapéutico , Complicaciones Posoperatorias , Topografía de la Córnea , Adolescente
3.
J Refract Surg ; 40(5): e328-e335, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717080

RESUMEN

PURPOSE: To evaluate moderate to high astigmatism corrections on the outcomes of SmartSight lenticule extraction for myopic astigmatism with a new femtosecond laser system. METHODS: Two hundred ninety-two eyes consecutively treated for myopic astigmatism with astigmatism magnitude greater than 1.00 diopter (D) were evaluated at the 6-month follow-up visit. The mean age of the patients was 29 ± 6 years with a mean spherical equivalent of -5.06 ± 2.20 diopters (D) and a mean magnitude of refractive astigmatism of 1.74 ± 0.61 D. RESULTS: At 6 months, astigmatism was 0.10 ± 0.20 D. Uncorrected and corrected distance visual acuities (UDVA and CDVA, respectively) were both 0.0 ± 0.1 logMAR. Differences between postoperative UDVA and preoperative CDVA and the change in CDVA were both +0.4 ± 0.7 lines better than preoperatively (P < .0003). CONCLUSIONS: Lenticule extraction treatment using Smart-Sight is safe and efficacious at 6 months. Findings suggest that moderate to high astigmatism improves after SmartSight lenticule extraction in the treatment of myopic astigmatism. [J Refract Surg. 2024;40(5):e328-e335.].


Asunto(s)
Astigmatismo , Sustancia Propia , Láseres de Excímeros , Miopía , Refracción Ocular , Agudeza Visual , Humanos , Astigmatismo/fisiopatología , Astigmatismo/cirugía , Agudeza Visual/fisiología , Estudios Retrospectivos , Adulto , Refracción Ocular/fisiología , Masculino , Femenino , Miopía/cirugía , Miopía/fisiopatología , Adulto Joven , Sustancia Propia/cirugía , Láseres de Excímeros/uso terapéutico , Topografía de la Córnea , Estudios de Seguimiento , Resultado del Tratamiento , Cirugía Laser de Córnea/métodos
4.
J Refract Surg ; 40(5): e336-e343, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717081

RESUMEN

PURPOSE: To assess and compare the visual acuity and refractive outcomes of topography-guided laser in situ keratomileusis (LASIK) based on the fitting-shape-based refractive compensated and Phorcides software strategies. METHODS: Consecutive patients who underwent topography-guided LASIK were included in this study. Through double-masked simple randomization, patients were assigned to the Zhang & Zheng Auto-compensate Refraction (ZZ AR) group (the fitting-shape-based refractive compensated strategy using the ZZ AR calculator was used) or the Phorcides group (the topography analysis algorithm in Phorcides software [Phorcides LLC] was used). Only one eye per patient with binocular correction was randomly enrolled. The preoperative and postoperative visual acuities and refraction were analyzed at the 6-month follow-up visit. RESULTS: The ZZ AR and Phorcides groups comprised 156 and 147 eyes, respectively. At the 6-month postoperative follow-up visit, the median (range) absolute residual cylindrical refraction was 0.35 (1.01) and 0.47 (1.63) diopters (D) for the ZZ AR and Phorcides groups, respectively (P < .001). The percentages of patients with residual cylindrical power within 0.25 D were 29.49% and 13.61% for the ZZ AR and Phorcides groups, respectively (P = .001). Based on the percentages of patients with residual cylindrical powers within 0.50 and 1.00 D, the ZZ AR group showed better outcomes (P = .02 and .01). The percentage of patients with visual acuity better than 20/16 was significantly higher for the ZZ AR group than for the Phorcides group (P = .03). CONCLUSIONS: The fitting-shape-based refractive compensated strategy for topography-guided LASIK procedures can better optimize the visual acuity and astigmatic refraction than the Phorcides software strategy. [J Refract Surg. 2024;40(5):e336-e343.].


Asunto(s)
Topografía de la Córnea , Queratomileusis por Láser In Situ , Láseres de Excímeros , Miopía , Refracción Ocular , Cirugía Asistida por Computador , Agudeza Visual , Humanos , Queratomileusis por Láser In Situ/métodos , Agudeza Visual/fisiología , Estudios Prospectivos , Refracción Ocular/fisiología , Adulto , Masculino , Femenino , Láseres de Excímeros/uso terapéutico , Método Doble Ciego , Miopía/cirugía , Miopía/fisiopatología , Adulto Joven , Cirugía Asistida por Computador/métodos , Persona de Mediana Edad , Córnea/cirugía , Córnea/fisiopatología , Estudios de Seguimiento
5.
J Refract Surg ; 40(5): e291-e303, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717083

RESUMEN

PURPOSE: To compare differences in corneal densitometry (CD) and higher order aberrations (HOAs) in eyes that underwent small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for the treatment of myopia and myopic astigmatism at postoperative months 3, 6, and 12, and to evaluate their changes in a separate cohort of eyes after SMILE enhancement. METHODS: In this prospective, randomized, paired-eye clinical trial, consecutive eligible participants were randomized to undergo SMILE or FS-LASIK in either eye. Main outcome measures were CD and HOAs preoperatively and at 3, 6, and 12 months postoperatively. A separate cohort of consecutive patients who had SMILE and underwent enhancement were also included for comparison. RESULTS: For CD, no significant differences were found between SMILE and FS-LASIK up to month 12. For HOA measured by wavefront aberrometry, both SMILE and FS-LASIK had an increase in total root mean square (RMS) HOAs, spherical aberration (SA), and vertical coma up to month 12. SMILE had an additional increase in vertical quatrefoil, and FS-LASIK had an increase in horizontal coma at month 12. FS-LASIK had higher SA than SMILE, whereas SMILE had higher vertical quatrefoil than FS-LASIK at month 12. Central and posterior zone CD had significantly decreased after SMILE enhancement compared to after primary SMILE up to 2 years after enhancement. RMS HOAs, lower order aberrations, and SA were all increased after SMILE enhancement compared to after primary SMILE. CONCLUSIONS: SMILE induced lower SA but higher vertical quatrefoil than FS-LASIK at 1 year. Both SMILE and FS-LASIK had similar increases in RMS HOAs and vertical coma up to 1 year. There were no differences in CD between both groups. SMILE enhancement additionally had decreased central and posterior CD but greater RMS HOAs and SA compared to primary SMILE. [J Refract Surg. 2024;40(5):e291-e303.].


Asunto(s)
Aberrometría , Astigmatismo , Córnea , Sustancia Propia , Aberración de Frente de Onda Corneal , Densitometría , Queratomileusis por Láser In Situ , Láseres de Excímeros , Miopía , Refracción Ocular , Agudeza Visual , Humanos , Queratomileusis por Láser In Situ/métodos , Aberración de Frente de Onda Corneal/fisiopatología , Estudios Prospectivos , Miopía/cirugía , Miopía/fisiopatología , Adulto , Femenino , Masculino , Láseres de Excímeros/uso terapéutico , Agudeza Visual/fisiología , Sustancia Propia/cirugía , Córnea/cirugía , Córnea/fisiopatología , Adulto Joven , Refracción Ocular/fisiología , Astigmatismo/cirugía , Astigmatismo/fisiopatología , Cirugía Laser de Córnea/métodos , Topografía de la Córnea
6.
J Refract Surg ; 40(5): e321-e327, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717082

RESUMEN

PURPOSE: To evaluate the characteristic of corrective epithelial thickness after femtosecond laser-assisted lenticule intrastromal keratoplasty (LIKE) to correct moderate-to-high hyperopia. METHODS: The prospective case series study of the LIKE procedure was performed to correct moderate-to-high hyperopia. The epithelial thickness map was generated by anterior segment optical coherence tomography (AS-OCT) in the corneal central 9-mm zone. Keratometry and corneal higher order aberrations were analyzed by Pentacam (Oculus Optikgeräte GmbH) preoperatively and postoperatively. RESULTS: In the 26 eyes of 13 participants who underwent the LIKE procedure for moderate-to-high hyperopia, the attempted spherical equivalence (SEQ) was +6.50 ± 1.09 diopters (D). Compared to the preoperative epithelial thickness maps, the postoperative epithelial thickness had become significantly thinner in the central 5-mm zone; the difference was 6 to 7 µm. The paracentral epithelium performed nonuniform remodeling; the thinnest epithelial thickness was located in the inferotemporal section, which has the greatest difference from the superonasal; the difference between these two was approximately 3 µm. Through correlation analysis, it was found that the sections with thinner epithelium were significantly related to corneal curvature and corneal vertical coma. CONCLUSIONS: The LIKE procedure can be used to correct moderate-to-high hyperopia. This study further indicated the epithelial remodeling characteristic after the LIKE procedure: the central and paracentral corneal epithelial thickness becomes thinner, and the epithelial thickness distributes non-uniformly, which may be the important factor of the postoperative curvature asymmetric distribution and induction of corneal vertical coma. [J Refract Surg. 2024;40(5):e321-e327.].


Asunto(s)
Sustancia Propia , Topografía de la Córnea , Epitelio Corneal , Hiperopía , Refracción Ocular , Tomografía de Coherencia Óptica , Agudeza Visual , Humanos , Hiperopía/cirugía , Hiperopía/fisiopatología , Estudios Prospectivos , Sustancia Propia/cirugía , Sustancia Propia/patología , Masculino , Femenino , Adulto , Agudeza Visual/fisiología , Epitelio Corneal/cirugía , Epitelio Corneal/patología , Refracción Ocular/fisiología , Persona de Mediana Edad , Láseres de Excímeros/uso terapéutico , Adulto Joven , Aberración de Frente de Onda Corneal/fisiopatología , Cirugía Laser de Córnea/métodos , Enfermedades Hereditarias del Ojo
7.
J Refract Surg ; 40(5): e344-e352, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717086

RESUMEN

PURPOSE: To compare the effects of three common refractive surgeries on corneal biomechanics. METHODS: Two hundred seven patients who had refractive surgery were included in this study, of whom 65 received transepithelial photorefractive keratectomy (tPRK), 73 received femtosecond laser-assisted laser in situ keratomileusis (FSLASIK), and 69 received small incision lenticule extraction (SMILE). Each patient had biomechanical measurements using the Corvis ST (Oculus Optikgeräte GmbH) preoperatively and at 3 and 6 months postoperatively. The measurements included five parameters expected to be associated with corneal biomechanics: deformation amplitude ratio at 2 mm (DAR2), integrated inverse radius (IIR), stiffness parameter at first applanation (SP-A1), highest concavity time (HCT), and the updated stress-strain index (SSIv2). The variations in these parameters postoperatively among the three surgeries, and their relationship with corneal thickness (CCT) and intraocular pressure measured by the Dynamic Contour Tonometer (DCT-IOP) were analyzed. RESULTS: SP-A1 decreased significantly from preoperatively to 3 months postoperatively in all three groups, whereas DAR2 and IIR increased significantly, all indicating stiffness losses. Between 3 and 6 months postoperatively, the results were inconsistent, with DAR2 decreasing (indicating stiffness increases) and IIR increasing (denoting stiffness decreases) in the FS-LASIK and SMILE groups. The decrease in SSIv2 (the only measure of corneal material stiffness) postoperatively was comparatively less pronounced at both 3 and 6 months postoperatively. On the other hand, HCT remained generally stable after all three surgeries. Unlike DAR2, IIR, and SP-A1, the changes postoperatively in stiffness parameters HCT and SSIv2 were independent of the corresponding changes in both DCT-IOP and CCT. CONCLUSIONS: Among the stiffness parameters considered, SSIv2 was not correlated with CCT or DCT-IOP, and holds promise for representing the corneal material stiffness and how it remains largely unaffected by refractive surgeries. Overall, FS-LASIK had the most significant impact on corneal stiffness, followed by SMILE, and finally tPRK. [J Refract Surg. 2024;40(5):e344-e352.].


Asunto(s)
Córnea , Elasticidad , Presión Intraocular , Queratomileusis por Láser In Situ , Láseres de Excímeros , Miopía , Humanos , Córnea/fisiopatología , Córnea/cirugía , Adulto , Femenino , Masculino , Fenómenos Biomecánicos , Láseres de Excímeros/uso terapéutico , Queratomileusis por Láser In Situ/métodos , Adulto Joven , Elasticidad/fisiología , Miopía/cirugía , Miopía/fisiopatología , Presión Intraocular/fisiología , Queratectomía Fotorrefractiva/métodos , Agudeza Visual/fisiología , Refracción Ocular/fisiología , Persona de Mediana Edad , Estudios Prospectivos , Cirugía Laser de Córnea/métodos , Topografía de la Córnea
8.
Sci Rep ; 14(1): 9984, 2024 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-38693352

RESUMEN

The aim of this work is to quantitatively assess the wavefront phase of keratoconic eyes measured by the ocular aberrometer t·eyede (based on WaveFront Phase Imaging Sensor), characterized by a lateral resolution of 8.6 µm without requiring any optical element to sample the wavefront information. We evaluated the parameters: root mean square error, Peak-to-Valley, and amplitude of the predominant frequency (Fourier Transform analysis) of a section of the High-Pass filter map in keratoconic and healthy cohorts. Furthermore, we have analyzed keratoconic eyes that presented dark-light bands in this map to assess their period and orientation with the Fourier Transform. There are significant statistical differences (p value < 0.001) between healthy and keratoconic eyes in the three parameters, demonstrating a tendency to increase with the severity of the disease. Otherwise, the quantification of the bands reveals that the width is independent of eye laterality and keratoconic stage as orientation, which tends to be oblique. In conclusion, the quantitative results obtained with t·eyede could help to diagnose and monitor the progression of keratoconus.


Asunto(s)
Queratocono , Queratocono/diagnóstico por imagen , Queratocono/diagnóstico , Humanos , Adulto , Femenino , Masculino , Topografía de la Córnea/métodos , Adulto Joven , Aberrometría/métodos , Córnea/diagnóstico por imagen , Córnea/patología , Análisis de Fourier
9.
Invest Ophthalmol Vis Sci ; 65(5): 29, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38767907

RESUMEN

Purpose: Keratoconus (KC) is a progressive corneal disease that can lead to corneal blindness if not properly managed. The purpose of this study was to identify genetic associations with KC in China and to investigate whether these genetic variants are associated with corneal thickness and corneal curvature in KC cases. Methods: A genome-wide association study was conducted on 853 patients with KC and 6248 controls. The KC cases were genotyped with the Illumina Infinium Human Asian Screening Array BeadChip, and the controls were genotyped with the Illumina Infinium Human Global Screening Array BeadChip. Genetic associations with KC, as well as correlations between the positive variants and corneal parameters including central corneal thickness (CCT) and mean keratometry (Km), were compared using PLINK version 1.90. Results: Our present study identified four single-nucleotide polymorphisms (SNPs) within four risk loci (PTGER3: rs2300163, EYA1: rs1077435, ASS1: rs141365191, and CHTF8: rs3743680) associated with KC in Chinese patients that reached genome-wide significance. Among the identified SNPs with P < 1.00 × 10-4, seven SNPs (FOSL2-PLB1: rs12622211, RXRA-COL5A1: rs3118515, rs3132306, rs1536482, rs3118520, KAT6B: rs192187772, RAP2A-IPO5: rs41361245) were observed to be associated with CCT, and one SNP (USP13: rs6767552) was found to be associated with Km. Conclusions: In the first genome-wide association study of KC with a relatively large study population in China, we identified four SNPs in four risk loci associated with the disease. The findings enriched the understanding of genetic susceptibility to KC and provided new insights into the genetic etiology of the disease.


Asunto(s)
Pueblo Asiatico , Predisposición Genética a la Enfermedad , Estudio de Asociación del Genoma Completo , Genotipo , Queratocono , Polimorfismo de Nucleótido Simple , Humanos , Queratocono/genética , Femenino , Masculino , China/epidemiología , Adulto , Pueblo Asiatico/genética , Adulto Joven , Persona de Mediana Edad , Córnea/patología , Adolescente , Sitios Genéticos , Topografía de la Córnea , Pueblos del Este de Asia
10.
Transl Vis Sci Technol ; 13(5): 7, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38727695

RESUMEN

Purpose: Multiple clinical visits are necessary to determine progression of keratoconus before offering corneal cross-linking. The purpose of this study was to develop a neural network that can potentially predict progression during the initial visit using tomography images and other clinical risk factors. Methods: The neural network's development depended on data from 570 keratoconus eyes. During the initial visit, numerical risk factors and posterior elevation maps from Scheimpflug imaging were collected. Increase of steepest keratometry of 1 diopter during follow-up was used as the progression criterion. The data were partitioned into training, validation, and test sets. The first two were used for training, and the latter for performance statistics. The impact of individual risk factors and images was assessed using ablation studies and class activation maps. Results: The most accurate prediction of progression during the initial visit was obtained by using a combination of MobileNet and a multilayer perceptron with an accuracy of 0.83. Using numerical risk factors alone resulted in an accuracy of 0.82. The use of only images had an accuracy of 0.77. The most influential risk factors in the ablation study were age and posterior elevation. The greatest activation in the class activation maps was seen at the highest posterior elevation where there was significant deviation from the best fit sphere. Conclusions: The neural network has exhibited good performance in predicting potential future progression during the initial visit. Translational Relevance: The developed neural network could be of clinical significance for keratoconus patients by identifying individuals at risk of progression.


Asunto(s)
Topografía de la Córnea , Aprendizaje Profundo , Progresión de la Enfermedad , Queratocono , Queratocono/diagnóstico por imagen , Queratocono/diagnóstico , Humanos , Femenino , Masculino , Adulto , Topografía de la Córnea/métodos , Adulto Joven , Factores de Riesgo , Córnea/diagnóstico por imagen , Córnea/patología , Adolescente , Persona de Mediana Edad , Redes Neurales de la Computación
11.
Curr Opin Ophthalmol ; 35(4): 315-321, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38700950

RESUMEN

PURPOSE OF REVIEW: This manuscript summarizes contemporary research from 2018 to 2023 evaluating long-term (≥2 years) outcomes of corneal crosslinking (CXL) for progressive keratoconus (KCN). RECENT FINDINGS: The standard Dresden protocol (SDP) has been utilized clinically since the early 2000 s to treat ectatic disorders, primarily progressive KCN and postrefractive ectasia. Various modifications have since been introduced including accelerated and transepithelial protocols, which are aimed at improving outcomes or reducing complications. This review summarizes data demonstrating that the SDP halts disease progression and improves various visual and topographic indices (UDVA, CDVA, Kmax, K1, K2) up to 13 years postoperatively. Accelerated and transepithelial protocols have been found to be well tolerated alternatives to SDP with similar efficacy profiles. Studies focusing on pediatric populations identified overall higher progression rates after CXL. All protocols reviewed had excellent safety outcomes in adults and children. SUMMARY: Recent studies revealed that SDP successfully stabilizes KCN long term, and a variety of newer protocols are also effective. Pediatric patients may exhibit higher progression rates after CXL. Further research is required to enhance the efficacy and ease of these protocols.


Asunto(s)
Colágeno , Reactivos de Enlaces Cruzados , Queratocono , Fotoquimioterapia , Fármacos Fotosensibilizantes , Riboflavina , Agudeza Visual , Humanos , Queratocono/tratamiento farmacológico , Queratocono/fisiopatología , Reactivos de Enlaces Cruzados/uso terapéutico , Fármacos Fotosensibilizantes/uso terapéutico , Riboflavina/uso terapéutico , Fotoquimioterapia/métodos , Colágeno/uso terapéutico , Agudeza Visual/fisiología , Rayos Ultravioleta , Sustancia Propia/metabolismo , Sustancia Propia/efectos de los fármacos , Resultado del Tratamiento , Topografía de la Córnea
12.
Vestn Oftalmol ; 140(2. Vyp. 2): 43-50, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38739130

RESUMEN

PURPOSE: This study investigates the influence of peripheral corneal thickness (PCT) and its curvature on tonometry readings. MATERIAL AND METHODS: The study included 49 patients (49 eyes) who were indicated for glaucoma surgery. Using bidirectional applanation tonometry, the following parameters were obtained: IOPcc, IOPg - intraocular pressure (IOP) corrected for corneal compensation, taken as the most reliable indicator; IOP converted to Goldmann measurement, taken as the result of applanation tonometry, ΔIOP (IOPcc-IOPg), CH and CRF (corneal hysteresis and corneal resistance factor). During corneal topography, the corneal thickness was studied in the center, PCT at 1.5; 2, 3, 4 and 5 mm from the center in four meridians, as well as ΔPCT (PCT 3 mm - PCT 1.5 mm), the curvature of the anterior and posterior surfaces of the cornea and the depth of the anterior chamber. Aberrometry was used to obtain refractometry data and the curvature of the anterior surface of the cornea. The influence of the studied parameters on ΔIOP was evaluated. RESULTS: ΔIOP correlated with CRF (r= -0.652), CH (r= -0.873), central corneal thickness (r= -0.293), PCT at all distances except 5 mm (r= -0.297; -0.287; -0.302; -0.303), with the strong and weak meridians of the anterior surface of the cornea (r=0.328; r=0.315), with the strong and weak meridians of the posterior surface, as well as the average curvature of the posterior surface (r=0.307; r=0.332; r=0.328). After step-by-step selection of the above parameters for creating a linear regression model for ΔIOP calculation, CH, CRF and PCT1.5mm remained in the model. The model describes ΔIOP with high accuracy (R2=0.974). CONCLUSION: Biomechanical parameters of the cornea are the leading factor of applanation tonometry error. Individual linear dimensions of the cornea (thickness, curvature) have a lesser effect.


Asunto(s)
Córnea , Topografía de la Córnea , Glaucoma , Presión Intraocular , Tonometría Ocular , Humanos , Tonometría Ocular/métodos , Córnea/diagnóstico por imagen , Presión Intraocular/fisiología , Masculino , Femenino , Persona de Mediana Edad , Topografía de la Córnea/métodos , Glaucoma/fisiopatología , Glaucoma/diagnóstico , Reproducibilidad de los Resultados , Anciano , Adulto
13.
BMC Ophthalmol ; 24(1): 158, 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38600456

RESUMEN

BACKGROUND: This study aimed to compare the visual outcomes of the first operated eyes with those of the second operated eyes following small-incision lenticule extraction (SMILE). METHODS: A total of 202 patients (404 eyes) underwent SMILE using the tear film mark centration method for myopia and myopic astigmatism correction. Baseline characteristics, objective optical quality, decentered displacement, induced corneal aberrations, and modulation transfer function (MTF) values were assessed. Linear regression analyzed the relationship between decentration and visual quality parameters, including corneal aberrations and MTF values. RESULTS: No significant difference was observed in objective visual quality, efficacy, and safety indexes between the two groups (all P > 0.05). The average decentered displacement for the first and second surgical eyes was 0.278 ± 0.17 mm and 0.315 ± 0.15 mm, respectively (P = 0.002). The horizontal coma in the first surgical eyes were notably lower than in the second (P = 0.000). MTF values at spatial frequencies of 5, 10, 15, and 20 cycles/degree (c/d) were higher in the first surgical eyes compared to the second (all P < 0.05). Linear regression indicated that high-order aberrations (HOAs), root mean square (RMS) coma, spherical aberration, horizontal coma, vertical coma, and eccentric displacement were all linearly correlated. Furthermore, MTF values exhibited a linear relationship with eccentric displacement across these spatial frequencies. CONCLUSIONS: There was no discernible difference in visual acuity, efficacy, or safety between the two operated eyes. Nonetheless, the first operated eyes exhibited reduced decentered displacement and demonstrated superior outcomes in terms of horizontal coma and MTF values compared to the second operated eyes following SMILE. The variations in visual quality parameters were linearly correlated with decentered displacement.


Asunto(s)
Astigmatismo , Aberración de Frente de Onda Corneal , Miopía , Humanos , Refracción Ocular , Coma , Topografía de la Córnea , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Astigmatismo/cirugía , Sustancia Propia/cirugía
14.
BMC Ophthalmol ; 24(1): 163, 2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38609888

RESUMEN

BACKGROUND: The aim was to validate the correlation between corneal shape parameters and axial length growth (ALG) during orthokeratology using Image-Pro Plus (IPP) 6.0 software. METHODS: This retrospective study used medical records of myopic children aged 8-13 years (n = 104) undergoing orthokeratology. Their corneal topography and axial length were measured at baseline and subsequent follow-ups after lens wear. Corneal shape parameters, including the treatment zone (TZ) area, TZ diameter, TZ fractal dimension, TZ radius ratio, eccentric distance, pupil area, and pupillary peripheral steepened zone(PSZ) area, were measured using IPP software. The impact of corneal shape parameters at 3 months post-orthokeratology visit on 1.5-year ALG was evaluated using multivariate linear regression analysis. RESULTS: ALG exhibited significant associations with age, TZ area, TZ diameter, TZ fractal dimension, and eccentric distance on univariate linear regression analysis. Multivariate regression analysis identified age, TZ area, and eccentric distance as significantly correlated with ALG (all P < 0.01), with eccentric distance showing the strongest correlation (ß = -0.370). The regressive equation was y = 1.870 - 0.235a + 0.276b - 0.370c, where y represents ALG, a represents age, b represents TZ area, and c represents eccentric distance; R2 = 0.27). No significant relationships were observed between the TZ radius ratio, pupillary PSZ area, and ALG. CONCLUSIONS: IPP software proves effective in capturing precise corneal shape parameters after orthokeratology. Eccentric distance, rather than age or the TZ area, significantly influences ALG retardation.


Asunto(s)
Cristalino , Niño , Humanos , Estudios Retrospectivos , Topografía de la Córnea , Análisis Multivariante , Programas Informáticos
15.
Arq Bras Oftalmol ; 87(4): e2023, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38656032

RESUMEN

We present a case of a patient complaining of monocular diplopia due to a decentered ablation after LASIK. The patient underwent a wavefront-guided retreatment, which resulted in an epithelial ingrowth complication. Additionally, the patient developed cataract, with cataract surgery requiring reliable biometric measurements. Therefore, we opted for corneal treatment and corneal surface regularization. Although we attempted to lift the flap and wash the interface initially, the procedure proved unsuccessful, thereby necessitating immediate flap amputation. Once the corneal surface was regularized in the seventh postoperative month, transepithelial photorefractive keratectomy was successfully performed to homogenize the ocular surface, thereby significantly improving the patient's corrected visual acuity and resolving monocular diplopia. The surface and corneal curvature stabilized by the fifth month after the procedure. Phacoemulsification was then performed along with the implantation of a toric monofocal lens, which was selected using an appropriate formula, resulting in an excellent uncorrected visual acuity.


Asunto(s)
Queratomileusis por Láser In Situ , Facoemulsificación , Colgajos Quirúrgicos , Agudeza Visual , Humanos , Facoemulsificación/efectos adversos , Queratomileusis por Láser In Situ/efectos adversos , Queratomileusis por Láser In Situ/métodos , Masculino , Diplopía/etiología , Resultado del Tratamiento , Topografía de la Córnea , Catarata , Persona de Mediana Edad
16.
Zhonghua Yan Ke Za Zhi ; 60(4): 330-336, 2024 Apr 11.
Artículo en Chino | MEDLINE | ID: mdl-38583056

RESUMEN

Objective: To investigate the influence of corneal e-value on the effectiveness of orthokeratology in controlling myopia in children and adolescents. Methods: A retrospective cohort study was conducted, involving the data from 1 563 myopic patients (1 563 eyes) who underwent orthokeratology at the Affiliated Eye Hospital of Shandong University of Traditional Chinese Medicine from June 2015 to August 2021 and adhered to lens wear for at least 2 years. The cohort consisted of 737 males and 826 females with an average age of (10.84±2.13) years. Based on corneal e-value parameters obtained from corneal topography, patients were categorized into a low e-value group (n=425) and a high e-value group (n=1 138). Data on gender, age, parental myopia history, and baseline measures such as spherical equivalent (SE), axial length, and corneal e-value were collected. Differences in axial length change and corneal fluorescein staining rates were compared between the two groups at 1 and 2 years after the start of lens wear. A generalized linear mixed model was established with axial length change as the dependent variable to analyze the correlation between axial length change and baseline corneal e-value. Results: The initial age of the 1 563 myopic patients was (10.84±2.13) years, with a baseline SE of (-3.05±1.30) D. After 1 year of lens wear, the axial length change was (0.20±0.19) mm in the low e-value group and (0.24±0.20) mm in the high e-value group. After 2 years, the changes were (0.38±0.25) mm and (0.43±0.27) mm, respectively, with statistically significant differences (all P<0.05). The incidence of corneal staining after 1 year of lens wear was 9.2% (39/425) in the low e-value group and 14.1% (160/1 138) in the high e-value group. After 2 years, the rates were 15.8% (67/425) and 21.8% (248/1 138), respectively, with statistically significant differences (all P<0.05). After adjusting for parental myopia history, age, SE, and baseline axial length, the baseline corneal e-value was positively correlated with axial length change at 1 and 2 years after lens wear (all P<0.05). Conclusions: Corneal e-value is an independent factor influencing the effectiveness of orthokeratology in controlling myopia. A smaller corneal e-value is associated with slower axial length growth after orthokeratology, indicating better control of myopia in treated eyes.


Asunto(s)
Lentes de Contacto , Miopía , Procedimientos de Ortoqueratología , Masculino , Femenino , Niño , Humanos , Adolescente , Estudios Retrospectivos , Longitud Axial del Ojo , Miopía/terapia , Topografía de la Córnea , Refracción Ocular
17.
Int Ophthalmol ; 44(1): 172, 2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38594548

RESUMEN

INTRODUCTION: Keratoconus is a progressive disorder of the cornea that causes thinning (Sedaghat et al. in Sci Rep 11(1):11971, 2021), ectasia, and irregular astigmatism, resulting in poor visual acuity that cannot be corrected with standard sphero-cylindrical spectacle lenses. One feature distinguishing keratoconic corneas is ocular aberrations, manifesting up to five or six times the amount of higher-order aberrations than a normal, healthy eye. These aberrations can cause visual disturbances even at the very early stages of the disease. METHODS: In the past, a diagnosis was derived from clinical symptoms, but technological advances have revealed multiple pre-clinical features, allowing for the differentiation between keratoconic and normal eyes at a much earlier stage. These include anterior and posterior corneal surface elevations, the corneal pachymetry profile, corneal epithelial patterns, wavefront aberration metrics, and corneal biomechanics (Sedaghat et al. in Sci Rep 11(1):11971, 2021).This review discusses the aberrations associated with keratoconus, how to measure them, and treatment methods to minimize their negative influence. CONCLUSIONS: Early diagnosis can lead to early treatment and may allow for arresting progression, thereby improving the long-term prognosis. With the acceleration of refractive surgery, it is important to identify patients with keratoconus, as they are usually contraindicated for refractive surgery.


Asunto(s)
Astigmatismo , Queratocono , Humanos , Queratocono/diagnóstico , Queratocono/etiología , Queratocono/terapia , Topografía de la Córnea/métodos , Córnea , Astigmatismo/diagnóstico , Trastornos de la Visión
18.
BMC Ophthalmol ; 24(1): 182, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38649848

RESUMEN

BACKGROUND: The precision of anterior segment biometric measurements in eyes has become increasingly important in refractive surgery. The purpose of this study is to assess the repeatability of the automatic measurements provided by a new spectral-domain optical coherence tomograph (SD-OCT)/Placido topographer (MS-39, CSO) and its agreement with a swept-source OCT (SS-OCT) biometer (CASIA SS-1000, Tomey) in patients with myopia. METHODS: The right eye of 235 subjects was scanned 3 times with both devices. The evaluated parameters included central corneal radius of the steep meridian, central corneal radius of the flat meridian, mean central corneal radius, thinnest corneal thickness, central corneal thickness, anterior chamber depth, corneal volume and diameter. The intraobserver repeatability of the MS-39 measurements was calculated using intraclass correlation coefficient (ICC), within subject standard deviation, coefficient of repeatability, coefficient of variation and repeated-measures analysis of variance of the 3 repeated measurements. The agreement between the two devices was evaluated by 95% limits of agreement (LoA). RESULTS: The majority of the parameters acquired from MS-39 showed high repeatability. The repeatability of corneal diameter was slightly lower than the other measurements, although the ICC remained high. Agreement with the CASIA SS-1000 was good, indicated by the Bland-Altman plots with narrow 95% LoA values for all parameters assessed. CONCLUSIONS: The high repeatability of automatic measurements by the new device supports its clinical application in eyes with myopia, and the good agreement between the two devices indicates they could be used interchangeably for the parameters evaluated.


Asunto(s)
Segmento Anterior del Ojo , Córnea , Topografía de la Córnea , Miopía , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Masculino , Femenino , Adulto , Miopía/diagnóstico , Miopía/fisiopatología , Topografía de la Córnea/métodos , Topografía de la Córnea/instrumentación , Reproducibilidad de los Resultados , Segmento Anterior del Ojo/diagnóstico por imagen , Segmento Anterior del Ojo/patología , Adulto Joven , Córnea/diagnóstico por imagen , Córnea/patología , Persona de Mediana Edad , Biometría/métodos , Adolescente , Estudios Prospectivos
19.
BMJ Open Ophthalmol ; 9(1)2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38653536

RESUMEN

OBJECTIVE: Our objective is to develop a novel keratoconus image classification system that leverages multiple pretrained models and a transformer architecture to achieve state-of-the-art performance in detecting keratoconus. METHODS AND ANALYSIS: Three pretrained models were used to extract features from the input images. These models have been trained on large datasets and have demonstrated strong performance in various computer vision tasks.The extracted features from the three pretrained models were fused using a feature fusion technique. This fusion aimed to combine the strengths of each model and capture a more comprehensive representation of the input images. The fused features were then used as input to a vision transformer, a powerful architecture that has shown excellent performance in image classification tasks. The vision transformer learnt to classify the input images as either indicative of keratoconus or not.The proposed method was applied to the Shahroud Cohort Eye collection and keratoconus detection dataset. The performance of the model was evaluated using standard evaluation metrics such as accuracy, precision, recall and F1 score. RESULTS: The research results demonstrated that the proposed model achieved higher accuracy compared with using each model individually. CONCLUSION: The findings of this study suggest that the proposed approach can significantly improve the accuracy of image classification models for keratoconus detection. This approach can serve as an effective decision support system alongside physicians, aiding in the diagnosis of keratoconus and potentially reducing the need for invasive procedures such as corneal transplantation in severe cases.


Asunto(s)
Queratocono , Queratocono/diagnóstico , Queratocono/clasificación , Humanos , Córnea/patología , Algoritmos , Topografía de la Córnea/métodos
20.
Indian J Ophthalmol ; 72(5): 712-717, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38648433

RESUMEN

PURPOSE: To compare the changes encountered in corneal biomechanics and aberration profile following accelerated corneal collagen cross-linking (CXL) using hypo-osmolar and iso-osmolar riboflavin in corneal thicknesses of <400 and >400 microns, respectively. METHODS: This is a prospective, interventional, comparative study involving 100 eyes of 75 patients with progressive keratoconus. Eyes were divided into two groups based on corneal thickness: group 1 included eyes with a corneal thickness of <400 microns who underwent hypo-osmolar CXL, and group 2 included eyes with a corneal thickness of >400 microns who underwent iso-osmolar CXL. Corneal biomechanical and aberration profiles were evaluated and compared between groups. RESULTS: In group 1, all higher-order aberrations (HOA) except secondary astigmatism significantly decreased from baseline; however, in group 2, only coma and trefoil decreased. The corneal resistance factor and corneal hysteresis significantly improved in both groups, which was significantly greater in group 2 than in group 1. The change in inverse radius, deformation amplitude, and tomographic biomechanical index was significantly improved in group 2 as compared to group 1. CONCLUSION: Improvement in corrected distance visual acuity and decrease in HOA were significantly better in the hypo-osmolar CXL group; however, the improvement in biomechanical strength of the cornea was significantly better in the iso-osmolar group.


Asunto(s)
Colágeno , Córnea , Topografía de la Córnea , Reactivos de Enlaces Cruzados , Queratocono , Fármacos Fotosensibilizantes , Riboflavina , Rayos Ultravioleta , Agudeza Visual , Adolescente , Adulto , Femenino , Humanos , Masculino , Adulto Joven , Fenómenos Biomecánicos , Colágeno/metabolismo , Córnea/diagnóstico por imagen , Córnea/fisiopatología , Córnea/efectos de los fármacos , Sustancia Propia/metabolismo , Sustancia Propia/efectos de los fármacos , Aberración de Frente de Onda Corneal/fisiopatología , Reactivos de Enlaces Cruzados/uso terapéutico , Estudios de Seguimiento , Queratocono/tratamiento farmacológico , Queratocono/fisiopatología , Queratocono/diagnóstico , Fotoquimioterapia/métodos , Fármacos Fotosensibilizantes/uso terapéutico , Estudios Prospectivos , Refracción Ocular/fisiología , Riboflavina/uso terapéutico , Agudeza Visual/fisiología , Niño
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA