Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Arthroplasty ; 38(7S): S194-S200, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37028772

RESUMO

BACKGROUND: The advent of highly porous ingrowth surfaces and highly crosslinked polyethylene has been expected to improve implant survivorship in revision total hip arthroplasty. Therefore, we sought to evaluate the survival of several contemporary acetabular designs following revision total hip arthroplasty. METHODS: Acetabular revisions performed from 2000 to 2019 were identified from our institutional total joint registry. We studied 3,348 revision hips, implanted with 1 of 7 cementless acetabular designs. These were paired with highly crosslinked polyethylene or dual-mobility liners. A historical series of 258 Harris-Galante-1 components, paired with conventional polyethylene, was used as reference. Survivorship analyses were performed. For the 2,976 hips with minimum 2-year follow-up, the median follow-up was 8 years (range, 2 to 35 years). RESULTS: Contemporary components with adequate follow-up had survivorship free of acetabular rerevision of ≥95% at 10-year follow-up. Relative to Harris-Galante-1 components, 10-year survivorship free of all-cause acetabular cup rerevision was significantly higher in Zimmer Trabecular Metarevision (hazard ratio (HR) 0.3, 95% confidence interval (CI) 0.2-0.45), Zimmer Trabecular MetaModular (HR 0.34, 95% CI 0.13-0.89), Zimmer Trilogy (HR 0.4, 95% CI 0.24-0.69), DePuy Pinnacle Porocoat (HR 0.24, 95% CI 0.11-0.51), and Stryker Tritanium revision (HR 0.46, 95% CI 0.24-0.91) shells. Among contemporary components, there were only 23 rerevisions for acetabular aseptic loosening and no rerevisions for polyethylene wear. CONCLUSION: Contemporary acetabular ingrowth and bearing surfaces were associated with no rerevisions for wear and aseptic loosening was uncommon, particularly with highly porous designs. Therefore, it appears that contemporary revision acetabular components have dramatically improved upon historical results at available follow-up.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Falha de Prótese , Desenho de Prótese , Acetábulo/cirurgia , Polietileno , Reoperação/efeitos adversos , Seguimentos
2.
J Arthroplasty ; 37(7S): S582-S587, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35256235

RESUMO

BACKGROUND: Contemporary total hip arthroplasty (THA) often employs larger femoral heads to optimize hip stability. However, pairing 40-mm femoral heads with the smallest compatible acetabular components poses a potential risk for implant failure. The purpose of this study is to evaluate the outcomes of primary THAs using 40-mm femoral heads and the smallest compatible acetabular components. METHODS: Between 2007 and 2018, 177 primary THAs involving 40-mm femoral heads and acetabular components ≤56 mm with highly cross-linked polyethylene liners were identified. Mean age was 61 years, 56% were females, and mean body mass index was 32 kg/m2. Cumulative incidences of dislocation, any revision, and any reoperation were determined utilizing a competing risk model. Osteolysis and femoral head penetration were assessed at minimum 8-year follow-up (n = 16). Mean follow-up was 6 years. RESULTS: There were no cases of liner fractures or dissociations. The 10-year cumulative incidences of dislocation, any revision, and any reoperation were 3.6%, 4.2%, and 6.8%, respectively. Mean linear femoral head penetration was 0.01 mm/y and mean volumetric wear rate was 50 mm3/y. One THA demonstrated stable, asymptomatic periacetabular radiolucent lines at most recent follow-up. CONCLUSION: In 177 primary THAs pairing 40-mm femoral heads with the smallest compatible acetabular components, there were no liner fractures or dissociations. The cumulative incidence of dislocation was modest at 10 years. The cumulative incidences of any revision and any reoperation were low at mid-term. LEVEL OF EVIDENCE: IV.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Luxações Articulares , Feminino , Cabeça do Fêmur/cirurgia , Humanos , Luxações Articulares/cirurgia , Masculino , Pessoa de Meia-Idade , Polietileno , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos
3.
J Arthroplasty ; 36(7S): S11-S17, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33622530

RESUMO

BACKGROUND: Contemporary total hip arthroplasty (THA) employs larger femoral heads to optimize hip stability. However, the combination of large femoral heads and comparatively small acetabular components poses a potential risk for implant failure secondary to polyethylene (PE) liner fracture or dissociation. The purpose of this study was to evaluate the incidence of liner fracture or dissociation, implant survivorship, and PE wear rates in primary THAs using large femoral heads and small acetabular components. METHODS: Between 2000 and 2017, we retrospectively identified 882 primary THAs with 36 mm femoral heads and acetabular components ≤52 mm with highly cross-linked polyethylene liners. Mean age was 66 years, 88% were females, and mean body mass index was 30 kg/m2. We evaluated the cumulative incidences of dislocation, any revision, and any reoperation utilizing a competing risk model. Osteolysis and femoral head penetration were assessed with a validated radiographic technique at minimum 10-year follow-up (n = 18). Mean follow-up was 4 years. RESULTS: There were no liner fractures or dissociations in the entire cohort. The 10-year cumulative incidences of dislocation, any revision, and any reoperation were 3.2%, 5.6%, and 9.3%, respectively. Mean linear femoral head penetration was 0.042 mm/y and mean volumetric wear rate was 44 mm3/y. No THAs demonstrated evidence of osteolysis or component loosening at long-term follow-up. CONCLUSION: In a large cohort of primary THAs pairing large femoral heads with small acetabular components, there was no evidence of liner fracture or dissociation. Cumulative incidences of dislocation, any revision, and any reoperation were low at mid-term. LEVEL OF EVIDENCE: IV.


Assuntos
Artroplastia de Quadril , Distinções e Prêmios , Prótese de Quadril , Idoso , Artroplastia de Quadril/efeitos adversos , Feminino , Prótese de Quadril/efeitos adversos , Humanos , Polietileno , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos
4.
J Arthroplasty ; 36(3): 1133-1137, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33121849

RESUMO

BACKGROUND: The purpose of this study was to evaluate a series of retrieved sleeved ceramic femoral heads used in total hip arthroplasty (THA) and determine qualitative and quantitative damage and corrosion patterns. METHODS: An IRB-approved implant retrieval database was utilized to identify all sleeved ceramic femoral heads collected from 1995 to 2004. There were 16 implants with an average duration of in situ of 70 months (range, 13-241 months). The femoral stem was known in 14 cases and was titanium alloy in each of those cases. None were revised for metal-related complications. Ten implants (63%) were from primary THAs, and 6 (38%) were from revision THAs. Damage and corrosion were qualitatively graded using a modified Goldberg method. A quantitative assessment was performed with a coordinate measurement machine (CMM). RESULTS: Among the 16 retrieved implants, 1 (6%) demonstrated severe Grade 4 corrosion, 5 (31%) had moderate Grade 3 corrosion, 5 (31%) had mild Grade 2 corrosion, and 5 (31%) had no visible corrosion at the inner sleeve that interfaces with the stem trunnion. The only case of grade 4 corrosion occurred in the only head-sleeve in the study that was not factory assembled and was mated with a titanium molybdenum zirconium ferrous (TMZF) alloy stem. The mean maximum linear corrosion depth at the taper interface, as measured by the CMM, was 7.7 microns (range, 0.9-32.9 microns). CONCLUSION: This study is the first to quantify corrosion at the titanium interface of sleeved ceramic femoral heads. Potentially clinically significant damage and corrosion patterns were observed in a few failed retrievals; however, the majority of cases demonstrated minimal or no damage.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Cerâmica , Ligas de Cromo , Corrosão , Cabeça do Fêmur/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Desenho de Prótese , Falha de Prótese
5.
J Arthroplasty ; 35(4): 1123-1129, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31852609

RESUMO

BACKGROUND: The aims of this study were to determine the levels of cobalt (Co) and chromium (Cr) ions generated in simulators from metal-on-polyethylene (MoP) and ceramic-on-polyethylene (CoP) constructs. Furthermore, we aimed to investigate the cytotoxic effect of these ion levels on native tissues and their potential to modify periprosthetic joint infection risk. METHODS: We used in vitro culture of human adipose-derived mesenchymal stem cells (AMSCs) and Staphylococcus epidermidis cultures, respectively. Ten hip simulator constructs (5 MoP and 5 CoP) were assembled and run for 1,000,000 cycles in bovine serum and evaluated for CoCr concentration. Cytotoxicity and growth impact on AMSCs and S. epidermidis was compared between CoCr and inert silicon dioxide. RESULTS: After 1,000,000 cycles, mean MoP and CoP Co concentration was 2264 and 0.6 ng/mL, respectively (P < .001). Mean MoP and CoP Cr concentration was 217 and 4.3 ng/mL, respectively (P < .001). Mean MoP Co:Cr ratio was 10:1. Co ions were significantly more toxic to human AMSCs than control silicon dioxide in a dose-response manner (P < .001). S. epidermidis growth was not significantly impacted by Co concentrations observed in the simulators. CONCLUSION: MoP constructs built in ideal conditions generated substantial CoCr debris, highlighting a baseline risk with these implants that may be exacerbated by host factors or imperfect surgical technique. Evaluation of impact on AMSCs suggests that debris levels produced under simulator conditions can be cytotoxic. In addition, these concentrations did not potentiate or inhibit S. epidermidis growth, suggesting that elevated periprosthetic joint infection rates with adverse local tissue reaction are related to other factors potentially associated with tissue necrosis.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Animais , Artroplastia de Quadril/efeitos adversos , Bovinos , Cerâmica , Cromo , Cobalto , Prótese de Quadril/efeitos adversos , Humanos , Íons , Polietileno , Desenho de Prótese
6.
J Arthroplasty ; 34(7S): S11-S16, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30765230

RESUMO

BACKGROUND: As revision implants and techniques have evolved and improved, understanding why contemporary revision total hip arthroplasties (THAs) fail is important to direct further improvement and innovation. As such, the goals of this study are to determine the implant survivorship of contemporary revision THAs, as well as the most common indications for re-revision. METHODS: We retrospectively reviewed 2589 aseptic revision THAs completed at our academic institution between 2005 and 2015 through our total joint registry. Thirty-nine percent were isolated acetabular revisions, 22% isolated femoral revisions, 18% both component revisions, and 21% head/liner component exchanges. The mean age at index revision THA was 66 years, and 46% were male. The indications for the index revision THA were aseptic loosening (21% acetabular, 15% femoral, 5% both components), polyethylene wear and osteolysis (18%), instability (13%), fracture (11%), and other (17%). Mean follow-up was 6 years. RESULTS: There were 211 re-revision THAs during the study period. The overall survivorship free of any re-revision at 2, 5, and 10 years was 94%, 92%, and 88%, respectively. The most common reasons for re-revision were hip instability (52%), peri-prosthetic fracture (11%), femoral aseptic loosening (11%), acetabular aseptic loosening (9%), infection (6%), polyethylene wear (3%), and other (8%). CONCLUSION: Compared to historical series, the 88% survivorship free of any re-revision at 10 years in a revision cohort at a referral center is notably improved. As implant fixation has improved, aseptic loosening has become much less common after revision THA, and instability has come to account for more than half of re-revisions.


Assuntos
Artroplastia de Quadril/métodos , Artroplastia de Quadril/estatística & dados numéricos , Falha de Prótese , Reoperação/estatística & dados numéricos , Acetábulo/cirurgia , Adulto , Idoso , Feminino , Fêmur/cirurgia , Seguimentos , Fraturas Ósseas/cirurgia , Prótese de Quadril , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Osteotomia , Polietileno , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos
7.
J Arthroplasty ; 34(3): 517-521, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30528131

RESUMO

BACKGROUND: Spondyloepiphyseal dysplasia (SED) is rare genetic condition which leads to skeletal and joint deformities that can predispose patients to degenerative joint disease. There are limited reports on the results of total hip arthroplasty (THA) in this patient population. The purpose of this study is to review clinical and radiographic outcomes of THA performed in patients with SED at one institution. METHODS: Among 43,917 patients undergoing primary THA from 1970 to 2015, we identified 50 THAs performed in 29 patients with SED; 21 patients underwent bilateral THA (none simultaneous). There were 16 females and 13 males; mean age, body mass index, and height were 39 years, 28.7 kg/m2, and 145 cm, respectively. All patients were able to ambulate prior to the THA. Mean follow-up was 11 years (range 2-38). RESULTS: Mean implant survival for primary THA in SED patients at the 5, 10, and 20-year time points was 96%, 85%, and 55%, respectively. Thirteen patients required revision THA, most commonly for polyethylene wear (n = 6) and aseptic loosening (n = 5), and 4 additional patients underwent nonrevision reoperations. Prior to surgery, 90% of patients had severe or moderate pain, which was reduced to 8% of patients postoperatively (P < .001). Mean Harris Hip Score improved from 47 to 87 (P < .001). Prior to surgery, 64% of patients required gait aids, which reduced to 34% postoperatively (P < .001). CONCLUSION: THA provided significant pain reduction and improvement in function, with a majority of patients ambulating independently following the procedure. There was a high incidence of complications following THA in patients with SED, most commonly secondary to polyethylene wear and osteolysis from conventional polyethylene and historical implants. LEVEL OF EVIDENCE: Level IV, Therapy.


Assuntos
Artroplastia de Quadril/efeitos adversos , Osteocondrodisplasias/congênito , Complicações Pós-Operatórias/etiologia , Adolescente , Adulto , Idoso , Artroplastia de Quadril/estatística & dados numéricos , Feminino , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/cirurgia , Osteocondrodisplasias/complicações , Osteocondrodisplasias/cirurgia , Osteólise/etiologia , Dor/etiologia , Dor/cirurgia , Polietileno , Período Pós-Operatório , Falha de Prótese , Recuperação de Função Fisiológica , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
8.
J Arthroplasty ; 33(5): 1501-1506, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29273288

RESUMO

BACKGROUND: Recurrent instability remains a challenge after revision total hip arthroplasty (THA). We report the outcomes of cementing a cementless dual mobility (DM) component into a stable acetabular shell for the treatment and/or prevention of instability in revision THA. METHODS: Eighteen patients (18 THAs) undergoing revision THA with a specific monoblock DM construct cemented into a new acetabular component or an existing well-fixed component from 2011 to 2014 were retrospectively reviewed. Tumor prostheses and total femoral replacements were excluded. In 9 patients (50%), components were implanted specifically for recurrent dislocations. Mean age was 64 years; mean follow-up was 3 years. Patients underwent an average of 4 prior hip operations (range 2-6). RESULTS: No cemented DM cups dissociated at the cement-cup interface. Three patients (17%) experienced a postoperative dislocation. One required a revision to constrained liner and 2 underwent open reduction with retention of the DM construct. Harris Hip Scores improved from 53 to 82 postoperatively (P < .001). CONCLUSION: Cementation of a monoblock cup DM construct, an off-label use as the construct is not specifically made for cementation, into a well-fixed acetabular component provides an alternative to enhance prosthetic stability in (1) recurrently dislocating THAs with well fixed, well-positioned acetabular components and (2) complex acetabular reconstructions in which constraint should be avoided. While not a perfect solution in this series, DM constructs provide a number of advantages including no added constraint at the interface and a large effective femoral head to diminish prosthetic impingement.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril , Cimentos Ósseos/química , Cimentação , Prótese de Quadril , Reoperação , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fêmur/cirurgia , Cabeça do Fêmur/cirurgia , Humanos , Luxações Articulares/cirurgia , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Amplitude de Movimento Articular , Recidiva , Estudos Retrospectivos
9.
J Arthroplasty ; 32(7): 2274-2278, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28285901

RESUMO

BACKGROUND: There are limited data on evaluating the significance of radiolucent lines and aseptic loosening in total knee arthroplasty (TKA). We sought to compare the sensitivity, specificity, and reliability of the Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System (KSRES) in detecting tibial component loosening compared to a novel percentage-based system (PBS). METHODS: We retrospectively reviewed radiographs obtained from 48 patients within 6 months prior to revision TKA. The radiographs were randomized and four reviewers independently used the KSRES to categorize tibial implants as nonconcerning, clinical follow-up for progression, or loose as described by KSRES. For the PBS, the percent involvement of the tibial implant interface of any radiolucency at the bone-cement or cement-implant interface was determined. The higher percentage from either the anteroposterior or the lateral image was the final score. Components were categorized as nonconcerning (≤10%), clinical follow-up for progression (11%-24%), or loose (≥25%). We compared the sensitivity, specificity, and interobserver reliability using intraoperative assessment of implant fixation as the gold standard. RESULTS: For the KSRES, the mean sensitivity for determining tibial loosening was 7.3% and mean specificity for determining a nonconcerning implant was 95.9%. The PBS significantly increased the sensitivity to 91.1% (P < .001) while maintaining a specificity of 87.9% (P = .2). Interobserver reliability significantly increased from a mean kappa of 0.26 to 0.75 (P < .001). CONCLUSION: The KSRES significantly underestimates implant loosening. The proposed percentage-based system demonstrated excellent sensitivity, specificity, and interobserver reliability in determining tibial implant loosening in this patient population.


Assuntos
Artroplastia do Joelho/efeitos adversos , Articulação do Joelho/diagnóstico por imagem , Prótese do Joelho/efeitos adversos , Falha de Prótese , Tíbia/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/instrumentação , Cimentos Ósseos , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Radiografia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
10.
J Arthroplasty ; 32(3): 836-842, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27816367

RESUMO

BACKGROUND: Biomechanical studies have suggested improved stress distribution in metal-backed (MB) compared to all-polyethylene (AP) tibias, but such potential benefits have not been realized clinically. The purpose of this investigation was to analyze the outcomes of AP components in patients with primary osteoarthritis and compare the results to those obtained with MB tibial components in total knee arthroplasty (TKA). METHODS: We reviewed 11,653 patients undergoing primary TKA for osteoarthritis. There were 9999 (86%) MB (8470 modular and 1529 monoblock) and 1654 (14%) AP tibial components. All patients had at least 2 years of clinical follow-up with mean follow-up of 8 years (range, 2-30 years). RESULTS: Mean survivorship for all primary TKAs at the 5-year, 10-year, 15-year, and 20-year time points was 97%, 92%, 86%, and 78%. AP tibial components were found to have improved survivorship when compared to modular and monoblock MB counterparts (P < .0001). Likewise, AP tibial components were found to have lower rates of tibial component loosening (P < .0001), tibial osteolysis, and component fracture. Furthermore, the AP group had improved survival rates in most age-groups except <55 years where there was no difference. AP tibial components demonstrated improved survival for all body mass index (BMI) groups except in patients with a BMI ≤25 kg/m2 where there was no difference. CONCLUSION: AP tibial components had significantly improved implant survival across all age-groups and most BMI categories in patients who underwent TKA for osteoarthritis. Given these outcomes, AP tibias are a reasonable option, regardless of patient age and BMI.


Assuntos
Artroplastia do Joelho/instrumentação , Prótese do Joelho/estatística & dados numéricos , Osteoartrite do Joelho/cirurgia , Desenho de Prótese , Tíbia/cirurgia , Idoso , Índice de Massa Corporal , Doenças das Cartilagens/cirurgia , Feminino , Humanos , Masculino , Minnesota/epidemiologia , Osteoartrite/cirurgia , Polietileno , Infecções Relacionadas à Prótese/epidemiologia , Reoperação/estatística & dados numéricos
11.
J Arthroplasty ; 31(7): 1476-82, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27067171

RESUMO

BACKGROUND: There is debate regarding tibial component modularity and composition in total knee arthroplasty (TKA). Biomechanical studies have suggested improved stress distribution in metal-backed tibias; however, these results have not translated clinically. The purpose of this study was to analyze the outcomes of all-polyethylene components and to compare the results to those with metal-backed components. METHODS: We reviewed 31,939 patients undergoing a primary TKA over a 43-year period (1970-2013). There were 28,224 (88%) metal-backed and 3715 (12%) all-polyethylene tibial components. The metal-backed and all-polyethylene groups had comparable demographics with respect to gender, age and body mass index (BMI). Mean follow-up was 7 years. RESULTS: The mean survival for all primary TKAs at the 5-, 10-, 20- and 30-year time points was 95%, 89%, 73%, and 57%, respectively. All-polyethylene tibial components were found to have a significantly improved (P < .0001) survivorship when compared with their metal-backed counterparts. All-polyethylene tibial components were also found to have a significantly lower rate of infection, instability, tibial component loosening, and periprosthetic fracture. The all-polyethylene group had improved survival rates in all age groups, except in patients 85 years old or greater, where there was no significant difference. All-polyethylene tibial components had improved survival for all BMI groups except in the morbidly obese (BMI ≥ 40) where there was no significant difference. CONCLUSION: All-polyethylene tibial components had significantly improved implant survival, reduced rates of postoperative infection, fracture, and tibial component loosening. All polyethylene should be considered for most of the patients, regardless of age and BMI.


Assuntos
Artroplastia do Joelho , Obesidade Mórbida/cirurgia , Polietileno/química , Tíbia/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Índice de Massa Corporal , Feminino , Seguimentos , Fraturas Ósseas/cirurgia , Humanos , Estimativa de Kaplan-Meier , Prótese do Joelho , Masculino , Metais , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Estresse Mecânico , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
12.
J Arthroplasty ; 31(12): 2814-2818, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27436501

RESUMO

BACKGROUND: Predisposing factors for trunnionosis and elevated metal ion levels in metal-on-polyethylene (MOP) total hip arthroplasty (THA) are currently unknown. METHODS: This retrospective cohort study enrolled 80 consecutive patients (43 males) with an asymptomatic MOP THA at 2- to 5-year follow-up and no other metal implants. Serum cobalt (Co) and chromium (Cr) levels were collected at the time of enrollment, and retrospective review was performed regarding demographic, implant, and surgical characteristics. Mean age at the time of surgery was 65.7 years (range 35.6-85.9 years), and mean postoperative follow-up was 28.7 months (range 24.4-58.9 months). RESULTS: Femoral head offset was the only evaluated factor shown to increase serum Co ion levels above baseline within the cohort. Mean difference in Co level for high and low offset implants was 0.58 ppb (95% confidence interval [CI] = 0.05-1.11 ppb; P = .03). Mean difference in Cr level for high and low offset implants was 0.19 ppb (95% CI = -0.23 to 0.60 ppb; P = .37). Mean difference in Co level for small and large femoral heads was 0.20 ppb (95% CI = -0.41 to 0.81 ppb; P = .59). Mean difference in Cr level for small and large femoral heads was 0.28 ppb (95% CI = -0.18 to 0.74 ppb; P = .06). Age, gender, Harris Hip Score, and implant duration were not associated with changes in metal ion levels. CONCLUSION: Femoral head offset appears to be an important source of elevated metal ion levels in MOP THA. Further studies will be needed to understand if increasing femoral head offset is associated with subsequent adverse local tissue reactions.


Assuntos
Artroplastia de Quadril/efeitos adversos , Cromo/sangue , Cobalto/sangue , Prótese de Quadril/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Cabeça do Fêmur , Humanos , Masculino , Metais/sangue , Pessoa de Meia-Idade , Polietileno , Período Pós-Operatório , Estudos Retrospectivos
13.
Clin Orthop Relat Res ; 473(6): 2031-41, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25516002

RESUMO

BACKGROUND: Total hip arthroplasty (THA) is increasingly being performed in patients with long life expectancies and active lifestyles. Newer implant bearing surfaces, with superior wear characteristics, often are used in this cohort with the goal of improving longevity of the prosthesis, but comparisons across the numerous available bearing surfaces are limited, so the surgeon and patient may have difficulty deciding which implants to use. QUESTIONS/PURPOSES: The purpose of this study was to answer the following question: Is there a short- to mid-term survivorship difference between common THA bearings used in patients younger than age 65 years? METHODS: We conducted a systematic review to identify randomized clinical trials (RCTs) published after 2000 that reported survivorship of ceramic-on-ceramic (CoC), ceramic-on-highly crosslinked polyethylene (CoPxl), or metal-on-highly crosslinked polyethylene (MoPxl) bearings. To qualify for our review, RCTs had to have a minimum 2-year followup and study patients were required to have an average age younger than 65 years. Direct-comparison meta-analysis and network meta-analysis were performed to combine direct and indirect evidence. RESULTS: Direct-comparison meta-analysis found no differences among the bearing surfaces in terms of the risk of revision; this approach demonstrated a risk ratio for revision of 0.65 (95% confidence interval [CI], 0.19-2.23; p = 0.50) between CoC and CoPxl and a risk ratio for revision of 0.40 (95% CI, 0.06-2.63; p = 0.34) between CoC and MoPxl. Network meta-analysis (with post hoc modification) likewise found no differences in survivorship across the three implant types, demonstrating the following probabilities of most effective implant with 95% credible intervals (CrI): CoC = 64.6% (0%-100%); CoPxl = 24.9% (0%-100%); and MoPxl = 9.9% (0%-100%). The CrIs ranged from 0% to 100% for all three bearing surfaces. Direct-comparison meta-analysis allowed for pooling of five RCTs, including 779 THAs, whereas network meta-analysis (before post hoc analysis) enabled pooling of 18 RCTs, including 2599 THAs. CONCLUSIONS: Current published evidence does not support survivorship differences among commonly used bearing surfaces in patients younger than age 65 years undergoing THA at short- to mid-term followup. Long-term RCT data will be needed to determine if a survivorship benefit is realized in younger, more active patients over time. LEVEL OF EVIDENCE: Level I, therapeutic study.


Assuntos
Artroplastia de Quadril/instrumentação , Articulação do Quadril/cirurgia , Prótese de Quadril , Próteses Articulares Metal-Metal , Desenho de Prótese , Fatores Etários , Artroplastia de Quadril/efeitos adversos , Fenômenos Biomecânicos , Cerâmica/química , Distribuição de Qui-Quadrado , Articulação do Quadril/fisiopatologia , Humanos , Metais/química , Pessoa de Meia-Idade , Razão de Chances , Polietileno/química , Falha de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Recuperação de Função Fisiológica , Reoperação , Fatores de Risco , Propriedades de Superfície , Fatores de Tempo , Resultado do Tratamento
15.
J Arthroplasty ; 28(5): 815-7, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23499405

RESUMO

The purpose of this study was to investigate the relatively long-term outcomes in 50 patients (54 hips) younger than 50 years of age who underwent total hip arthroplasty using highly cross-linked polyethylene (HXLPE) liners. With a minimum follow-up of 10 years, mean age at time of surgery was 38.9 years (range, 15-50 years). Survivorship was 100%. There was no radiographic evidence of osteolysis or component loosening. Mean steady-state femoral head penetration rate was 0.020 ± 0.0047 mm/yr. Clinical outcomes were excellent, with mean Harris hip score of 91.2 (range, 72-99) points at final follow-up.


Assuntos
Artroplastia de Quadril/instrumentação , Polietileno , Adolescente , Adulto , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Radiografia , Resultado do Tratamento , Adulto Jovem
16.
J Am Acad Orthop Surg ; 19(9): 527-35, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21885698

RESUMO

Most total knee arthroplasty prostheses have modular tibial components with metal-backed tibial baseplates. Biomechanical studies have demonstrated mechanical advantages to a metal-backed tibial component in terms of tibial load transfer. In addition, tibial component modularity provides intraoperative flexibility and may provide an advantage in the setting of subsequent revision knee surgery. However, clinical evidence does not support the preferential use of metal-backed tibial components. Modularity introduces the potential for backside wear and associated osteolysis. Also, several recent studies have shown no significant differences in clinical and radiographic outcomes between metal-backed and all-polyethylene tibial components. In addition, all-polyethylene tibial components are less expensive than metal-backed components; increased usage of all-polyethylene components could help decrease the cost of health care.


Assuntos
Artroplastia do Joelho/instrumentação , Prótese do Joelho , Polietileno , Fenômenos Biomecânicos , Humanos , Desenho de Prótese , Falha de Prótese , Tíbia
17.
J Bone Joint Surg Am ; 103(19): 1826-1833, 2021 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-33974592

RESUMO

BACKGROUND: Most North American surgeons predominantly use uncemented stems in primary total hip arthroplasties (THAs) and reserve cemented stems for selected older patients and those with poor bone quality. However, data on this "selective use" strategy for cemented stems in the population at risk for periprosthetic fracture and implant loosening are limited. The purpose of this study was to describe implant survivorship, complications, and radiographic results of a specific collarless, polished, tapered cemented stem (Exeter; Stryker) used selectively in a predominantly elderly population undergoing primary THA. METHODS: We identified 386 patients who underwent a total of 423 primary THAs with selectively utilized Exeter stems for the treatment of osteoarthritis between 2006 and 2017. In the same time period, 11,010 primary THAs were performed with uncemented stems and 961 with non-Exeter cemented stems. The mean patient age was 77 years, 71% were female, and the mean body mass index was 29 kg/m2. Competing risk analysis accounting for death was utilized to determine cumulative incidences of revision and reoperation. The mean follow-up was 5 years (range, 2 to 12 years). RESULTS: The 10-year cumulative incidence of any femoral component revision in this patient cohort was 4%, with 10 stems revised at the time of the latest follow-up. There were no intraoperative femoral fractures. The indications for revision were postoperative periprosthetic femoral fracture (n = 6), dislocation (n = 3), and infection (n = 1). There were no revisions for femoral loosening. The 10-year cumulative incidence of reoperation was 10%. The 10-year cumulative incidence of Vancouver B periprosthetic femoral fracture was 2%. Radiographically, there were no cases of aseptic loosening or osteolysis. There was a significant improvement in median Harris hip score, from 53 preoperatively to 92 at a mean follow-up of 5 years (p < 0.001). CONCLUSIONS: The strategy of selectively utilizing a collarless, polished, tapered cemented stem produced a low (4%) cumulative incidence of stem revision at 10 years postoperatively and resulted in no cases of aseptic loosening. The use of the Exeter stem did not eliminate postoperative femoral fractures in this predominantly elderly, female patient population. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Cimentos Ósseos , Cimentação , Feminino , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos
18.
J Bone Joint Surg Am ; 102(16): 1397-1404, 2020 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-32816416

RESUMO

BACKGROUND: The cementation of a new liner into a well-fixed acetabular component is common during revision total hip arthroplasty (THA) for many indications, but most commonly for lack of a modern, compatible, highly cross-linked polyethylene (HXLPE) liner. However, little is known about the intermediate-term to long-term durability of this strategy. The purpose of this study was to evaluate the implant survivorship, risk of complications, clinical outcomes, and radiographic results of cementing a new HXLPE liner into a well-fixed acetabular component. METHODS: We retrospectively identified 323 revision THAs in which a nonconstrained HXLPE liner was cemented into a well-fixed acetabular component. The mean age at the time of the revision THA was 63 years, and 50% of patients were female. The most common indications for revision THA were polyethylene wear and osteolysis (48%), aseptic femoral loosening (35%), and hip instability (8%). The mean follow-up was 9 years. RESULTS: Polyethylene liner failure occurred in 11 cases (3%). In all cases, the cemented liner dissociated from the acetabular component. At 10 years, the survivorship free from any revision was 80% (95% confidence interval [CI], 75% to 84%) and the survivorship free from any reoperation was 77% (95% CI, 72% to 82%). The most common reason for re-revision was dislocation (45% of reoperations). A dislocation occurred in 17% of cases. Hips that underwent revision for instability were significantly more likely to dislocate compared with hips that underwent revision for liner wear (hazard ratio [HR], 2.3 [95% CI, 1.2 to 4.5]; p = 0.02). Elevated rim or face-changing liners were significantly more likely to dissociate than flat liners (HR, 9.0 [95% CI, 1.2 to 70.6]; p = 0.04). CONCLUSIONS: Cementation of a nonconstrained HXLPE liner into a well-fixed acetabular component during revision THA provided durable fixation with only a small number of failures at the cement interface (3%). Instability after this procedure remains a concern, but this is multifactorial in nature. These data support the continued use of this technique, when necessary, during revision THA. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Cimentação/métodos , Reoperação/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/instrumentação , Cimentos Ósseos , Cimentação/instrumentação , Feminino , Seguimentos , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Reoperação/instrumentação , Estudos Retrospectivos , Adulto Jovem
19.
J Bone Joint Surg Am ; 101(17): 1563-1568, 2019 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-31483399

RESUMO

BACKGROUND: Osteonecrosis of the hip is the underlying etiology for 3% to 12% of total hip arthroplasties (THAs). Compared with patients who undergo THA because of osteoarthritis, those who do so because of osteonecrosis typically are younger, have a greater number of underlying diagnoses, and have inferior clinical outcomes and implant survivorship. The purpose of this study was to compare the long-term implant survivorship (median follow-up, 10 years), functional outcomes, and radiographic results of contemporary THAs with a highly cross-linked polyethylene (HXLPE) liner between patients with osteonecrosis and those with osteoarthritis. METHODS: All patients who underwent primary THA with an HXLPE liner from 1999 to 2007 were identified from our institutional total joint registry. Patients with a primary diagnosis of osteonecrosis were matched 1:1, on the basis of age, sex, and body mass index (BMI), to patients with a diagnosis of osteoarthritis. This resulted in 461 hips in 413 patients with osteonecrosis matched to 461 hips in 427 patients with osteoarthritis (mean age, 59 years; 47% female; and mean BMI, 29 kg/m). Long-term implant survivorship, patient-reported outcomes, and radiographic findings were compared. In addition, a subgroup analysis of the osteonecrosis group was performed to see whether certain underlying etiologies portended poor outcomes. The median follow-up was 10 years. RESULTS: The 15-year cumulative rates of revision were 6.6% and 4.5% in the osteonecrosis and osteoarthritis groups, respectively (hazard ratio [HR] = 1.8, p = 0.09). The 15-year cumulative rates of any reoperation were 10.5% and 6.4% in the osteonecrosis and osteoarthritis groups, respectively (HR = 2.2, p = 0.008). There were no radiographic signs of component loosening or osteolysis in the entire cohort. Despite a lower median preoperative Harris hip score (HHS) for patients with osteonecrosis, both groups had marked improvements in their scores, which were similar at all time points after surgery. The cumulative rate of reoperations at 15 years was 0% for hips with radiation-induced osteonecrosis, 6.3% for those with alcohol-induced osteonecrosis, 9.0% for those with posttraumatic osteonecrosis, 12.1% for those with steroid-induced osteonecrosis, and 25% for those with idiopathic osteonecrosis. CONCLUSIONS: Contemporary THA with an HXLPE liner offers excellent long-term implant survivorship and functional outcomes for patients with osteonecrosis; however, the risk of a reoperation is higher when compared with patients with osteoarthritis. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia de Quadril/instrumentação , Osteonecrose/cirurgia , Polietileno/uso terapêutico , Artroplastia de Quadril/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Estudos Prospectivos , Falha de Prótese , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Resultado do Tratamento
20.
J Bone Joint Surg Am ; 101(7): 620-627, 2019 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-30946196

RESUMO

BACKGROUND: Cementation of a constrained liner is a viable option for treating instability after total hip arthroplasty (THA) when the acetabular component is well fixed and well aligned. However, concerns regarding long-term mechanical failure and recurrent instability remain. The aim of this study was to evaluate the long-term survivorship, complications, and clinical and radiographic outcomes of constrained polyethylene liners cemented into well-fixed acetabular components at the time of revision THA. METHODS: We identified 125 cases in which a constrained liner of 1 design was cemented into a retained, osseointegrated acetabular component during revision THA between 1998 and 2006. The mean patient age at revision was 70 years. Mean follow-up was 7 years. Survivorship data, risk of instability, and clinical and radiographic outcomes were analyzed. RESULTS: Survivorship free from revision for instability was 86% at 5 years and 81% at 10 years. Survivorship free from aseptic acetabular component revision was 78% at 5 years and 65% at 10 years, with the most common failure mechanism being dissociation of the constrained liner from the acetabular component. Survivorship free from revision for any reason was 76% at 5 years and 60% at 10 years. The most common complications were instability and periprosthetic joint infection, with cumulative incidences at 7 years of 18% and 11%, respectively. Harris hip scores did not significantly improve. Cup position did not affect implant survivorship or risk of dislocation. CONCLUSIONS: Cementing a constrained liner into a retained acetabular shell at the time of revision THA has durable long-term results, with 8 in 10 patients free from instability at 10 years. Aseptic acetabular survivorship was worse (65%) at 10 years, primarily due to dissociation of the constrained liner from the acetabular component. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Cimentação , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Acetábulo , Adulto , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA