Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 91
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Biomed Chromatogr ; 36(3): e5298, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34913179

RESUMEN

This is a metabolomics study for monitoring altered amino acid (AA) and organic acid (OA) metabolism of in eyes from aging an mouse model at 8 and 18 weeks and 18 months. Simultaneous metabolic profiling analysis of OAs and AAs was performed as ethoxycarbonyl/methoxime/tert-butyldimethylsilyl derivatives by gas chromatography-tandem mass spectrometry. A total of 42 metabolites-24 AAs and 18 OAs-were determined and their composition values were normalized to the corresponding mean values of 8-week-old mice as the control group. Then their normalized values were plotted as star graphs, which were distorted and readily distinguishable for each age-related group. Among the 42 metabolites, 18 AAs and 11 OAs were age dependent and significantly different (p < 0.05). Principal component analysis and partial least squares discriminant analysis showed unclear separation between 8- and 18-week-old mice but clear separation between these and 18-month-old mice. In particular, the variable importance in projection scores of 4-hydroxyproline, cis-aconitic acid, glycine, isocitric acid, leucine, pipecolic acid and lysine from partial least-squares-discriminant analysis were higher than 1.3. A heatmap for the classification and visualization of 42 metabolites showed differences in metabolite changes with aging. Altered AA and OA profiles were monitored, which may explain the metabolic disturbance of AA and OA. These findings are related to mitochondrial dysfunctions related to energy metabolism and the impaired antioxidant system in the aging eye. Therefore, the present metabolomics results of the association between physiological states and altered metabolism of AA and OA will be useful for understanding the aging eye and related diseases.


Asunto(s)
Aminoácidos , Espectrometría de Masas en Tándem , Envejecimiento , Aminoácidos/metabolismo , Animales , Cromatografía de Gases y Espectrometría de Masas/métodos , Metabolómica/métodos , Ratones
2.
Am J Orthod Dentofacial Orthop ; 161(2): 208-219, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34753591

RESUMEN

INTRODUCTION: Controlling transverse discrepancies is necessary to ensure stable and functional occlusion. Altered molar inclinations can camouflage the transverse relationship. The purpose of this research was to evaluate the maxillomandibular relationship of the center of resistance (CR) of the arch form created by the CR of teeth and compare these CR arch forms by their skeletal patterns. METHODS: Sixty patients with minor crowding and normal posterior overjet were divided into 3 groups according to ANB angle: skeletal Class I group had ANB angle between 0° and 4° (n = 20), skeletal Class II group had ANB angle >4° (n = 20), and skeletal Class III group had ANB angle <0° (n = 20). The 3-dimensional coordinates of the CR were estimated using cone-beam computed tomography images and projected on the CR occlusal plane to obtain the 2-dimensional coordinates. The CR arch forms were constructed and evaluated using Matlab (MathWorks, Natick, Mass). RESULTS: On comparing maxillomandibular CR arch form widths, the maxilla was significantly larger than the mandible of the canine and first premolar. The mandible was larger in the first molar of the skeletal Class III group. The maxillomandibular CR arch form width ratios were between 0.97 and 1.35. On comparing maxillomandibular CR arch form areas, the maxilla was significantly larger than the mandible in the anterior segment, and the mandible was larger in the posterior segment. The ratios were between 0.86 and 2.25. In between-group comparison, the skeletal Class III group showed significantly greater arch forms in the mandible. CONCLUSIONS: CR arch forms had significant maxillomandibular differences throughout the arch. The maxillomandibular ratios could be a reference for site-specific transverse discrepancy analysis.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Maloclusión , Cefalometría , Humanos , Mandíbula/diagnóstico por imagen , Maxilar/diagnóstico por imagen
3.
J Nat Prod ; 84(8): 2249-2255, 2021 08 27.
Artículo en Inglés | MEDLINE | ID: mdl-34387477

RESUMEN

Acremonamide (1) was isolated from a marine-derived fungus belonging to the genus Acremonium. The chemical structure of 1 was established using MS, UV, and NMR spectroscopic data analyses. Acremonamide (1) was found to contain N-Me-Phe, N-Me-Ala, Val, Phe, and 2-hydroxyisovaleric acid. The absolute configurations of the four aforementioned amino acids were determined through acid hydrolysis followed by the advanced Marfey's method, whereas the absolute configuration of 2-hydroxyisovaleric acid was determined through GC-MS analysis after formation of the O-pentafluoropropionylated derivative of the (-)-menthyl ester of 2-hydroxyisovaleric acid. As an intrinsic biological activity, acremonamide (1) did not exert cytotoxicity to cancer and noncancer cells and increased the migration and invasion. Based on these activities, the wound healing properties of acremonamide (1) were confirmed in vitro and in vivo.


Asunto(s)
Acremonium/química , Péptidos Cíclicos/farmacología , Cicatrización de Heridas/efectos de los fármacos , Animales , Organismos Acuáticos/química , Células CACO-2 , Células HaCaT , Humanos , Masculino , Ratones , Ratones Endogámicos BALB C , Estructura Molecular , Células 3T3 NIH , Péptidos Cíclicos/aislamiento & purificación
4.
Sensors (Basel) ; 21(17)2021 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-34502665

RESUMEN

The aim of this study was to evaluate periodontal risk factors with oral health habits and fluorescent plaque index (FPI) using quantitative light-induced fluorescence (QLF) images, and to evaluate their effect on the degree of radiographic bone loss (RBL). Selected were 276 patients over 19 years of age to complete the questionnaire for oral health habit and take QLF images, periapical and panoramic radiographs. Oral health habit score, age, and sex showed a statistically significant correlation with FPI. FPI showed a lower value as the oral health habit score increased and the age decreased. Moreover, females showed lower FPI values than did males. RBL showed a statistically significant positive correlation with age but did not show any correlation with oral health habit scores and sex. There was no correlation between FPI and RBL. The results of this study suggest that the clinical use of QLF allows plaque detection by non-invasive procedures and can aid in a more objective estimation for oral hygiene status.


Asunto(s)
Fluorescencia Cuantitativa Inducida por la Luz , Femenino , Hábitos , Humanos , Masculino , Salud Bucal , Estudios Retrospectivos , Factores de Riesgo
5.
Sensors (Basel) ; 21(17)2021 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-34502801

RESUMEN

Accurate bracket placement is essential for successful orthodontic treatment. An indirect bracket bonding system (IDBS) has been developed to ensure proper bracket positioning with three-dimensional computer-aided transfer jigs. The purpose of this study was to investigate the accuracy of bracket positioning by a one-body transfer jig according to the tooth type and presence/absence of a resin base. In total, 506 teeth from 20 orthodontic patients were included in this study. After initial dental models were scanned, virtual setup and bracket positioning procedures were performed with 3D software. Transfer jigs and RP models were fabricated with a 3D printer, and brackets were bonded to the RP model with or without resin base fabrication. The best-fit method of 3D digital superimposition was used to evaluate the lineal and angular accuracy of the actual bracket position compared to a virtual bracket position. Although all the measurements showed significant differences in position, they were clinically acceptable. Regarding the tooth types, premolars and molars showed higher accuracy than anterior teeth. The presence or absence of a resin base did not consistently affect the accuracy. In conclusion, the proper application of IDBS should be performed considering the errors, and resin base fabrication might not be essential in ensuring high-accuracy IDBS.


Asunto(s)
Soportes Ortodóncicos , Diente , Humanos , Modelos Dentales , Diente/diagnóstico por imagen
6.
Sensors (Basel) ; 21(2)2021 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-33445758

RESUMEN

This study was designed to develop and verify a fully automated cephalometry landmark identification system, based on multi-stage convolutional neural networks (CNNs) architecture, using a combination dataset. In this research, we trained and tested multi-stage CNNs with 430 lateral and 430 MIP lateral cephalograms synthesized by cone-beam computed tomography (CBCT) to make a combination dataset. Fifteen landmarks were manually and respectively identified by experienced examiner, at the preprocessing phase. The intra-examiner reliability was high (ICC = 0.99) in manual identification. The results of prediction of the system for average mean radial error (MRE) and standard deviation (SD) were 1.03 mm and 1.29 mm, respectively. In conclusion, different types of image data might be the one of factors that affect the prediction accuracy of a fully-automated landmark identification system, based on multi-stage CNNs.


Asunto(s)
Puntos Anatómicos de Referencia , Cefalometría/métodos , Tomografía Computarizada de Haz Cónico/métodos , Redes Neurales de la Computación , Anomalías Craneofaciales/diagnóstico por imagen , Bases de Datos Factuales , Humanos , Imagenología Tridimensional/métodos , Reproducibilidad de los Resultados , Estudios Retrospectivos
7.
Sensors (Basel) ; 21(6)2021 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-33799632

RESUMEN

High orthodontic forces and various directions of applied forces can be associated with loosening of the screw anchorage in the bone. Screw designs have been modified to increase the stability of the miniscrews. This research evaluates the influence of three-designs on the stability of orthodontic miniscrews. A conventionally cylinder-type miniscrew design (Bio-Action screw, Jin-Biomed co., Bucheon, Korea) was set as a control, and three conditions were studied based on modifications of this control design. Condition-1 has narrowed threads in the upper part of the screw; Condition-2 has a notch at the middle part; and Condition-3 has the combination of Condition-1 and Condition-2. The moment required to unwind the miniscrew to five degrees is tested, and the moment generated at the cortical bone and the trabecular bone were calculated with finite element analysis. Compared to the control, all three conditions showed a higher moment required to unwind the miniscrew and a higher moment generated at the cortical bone. At the trabecular bone, condition-2 and -3 showed higher moment than the control, and condition-1 showed similar moment to the control. Condition-3 required a higher overall moment to unwind the miniscrew. These findings validate the design modifications used to increase the rotational resistance.


Asunto(s)
Métodos de Anclaje en Ortodoncia , Tornillos Óseos , Análisis de Elementos Finitos , República de Corea , Titanio
8.
Sensors (Basel) ; 21(5)2021 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-33802443

RESUMEN

The aim of this study was to present an optimal diagnostic protocol by comparing and analyzing a conventional examination and the quantitative light-induced fluorescence (QLF) technique. Selected were 297 teeth of 153 patients to take QLF images and bitewing radiographs. Occlusal dental caries, proximal dental caries and cracks were evaluated and scored using QLF, X-ray and/or visual criteria. The sensitivity, specificity, and area under the curve (AUC) of a receiver operating characteristic analysis were calculated. Two fluorescence parameters (|ΔFmax| and ΔRmax) were utilized to evaluate the fluorescence pattern according to the severity of lesions based on QLF or X-ray criteria. QLF showed higher scores for detecting occlusal dental caries and cracks than the conventional method. ΔRmax increased more clearly than ΔFmax did with occlusal dental caries. The |ΔFmax| values of occlusal dental caries, proximal dental caries and cracks showed good AUC levels (0.84, 0.81 and 0.83, respectively). The ΔRmax of occlusal dental caries showed the highest AUC (0.91) and the ΔRmax of proximal dental caries showed a fail level (0.59) compared to bitewing radiographs. The QLF image could visualize and estimate the degree of occlusal dental caries or cracks. Consequently, the QLF technique may be an adjunct tool to conventional methods for the detection of occlusal caries and peripheral cracks.


Asunto(s)
Caries Dental , Fluorescencia Cuantitativa Inducida por la Luz , Diente , Caries Dental/diagnóstico por imagen , Fluorescencia , Humanos , Curva ROC , Estudios Retrospectivos , Sensibilidad y Especificidad
9.
Sensors (Basel) ; 21(2)2021 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-33451097

RESUMEN

The aim of this preliminary study was to evaluate the short-term changes of occlusal contacts and muscle activity after orthodontic treatment during the use of a multi-layer clear retainer. Evaluation was done with the T-scan and BioEMG systems. A total of 18 subjects were included, who were evaluated at three time intervals-T0 at debonding, T1 at one month after retainer delivery, and T2 at four months after retainer delivery. The T-scan and electromyography (EMG) data were recorded simultaneously. The T-scan system recorded the occlusion time, disclusion time and force distribution. The EMG waves were quantified by calculating the asymmetry index and activity index. The time variables changed but not significantly. Occlusal force decreased in the anterior dentition and increased in the posterior dentition during T0-T2. There was no clear evidence of a relationship between unbalanced occlusal forces and muscle activity. In most subjects, the temporalis anterior muscle was more dominant than the masseter muscle. From this preliminary computerized study, there were no significant changes in the state of the occlusion or muscle activity during the short-term retention period.


Asunto(s)
Músculo Masetero , Adolescente , Adulto , Fuerza de la Mordida , Electromiografía , Femenino , Humanos , Masculino , Músculo Temporal , Diente , Adulto Joven
10.
Am J Orthod Dentofacial Orthop ; 159(6): 799-807, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33762139

RESUMEN

INTRODUCTION: C-expanders are tissue- and bone-borne maxillary expanders that are anchored by 6 orthodontic miniscrews, 3 on each side of the palate. The purpose of the study was to investigate the effect of C-expanders on the circummaxillary sutures and bucco-palatal axis of teeth in 3-dimensional finite element analyses when anchor screw vectors are different. METHODS: Five expansion models were studied on the basis of the vertical positions of anchor screws on the palate. Anchor screws for models A, B, and C were placed symmetrically at 4 mm, 7 mm, and 15 mm below the cementoenamel junction (CEJ), respectively. Anchor screws for models D and E were placed asymmetrically at 4 mm and 15 mm below CEJ and 7 mm and 15 mm below CEJ, respectively. Stress, displacement, and angular changes of the bone and teeth were measured in elastoplastic behavior models using a static-nonlinear simulation in an implicit method. RESULTS: Symmetrical and asymmetrical anchor screw placement with different vertical vectors were compared using finite element analyses on 5 models. CONCLUSIONS: Using different vectors of anchor screws for C-expanders does change the pattern of palatal expansion (null hypothesis was rejected). The current investigation presents a promising future of controlled asymmetric skeletal maxillary expansion when asymmetric maxillary architecture needs to be corrected for successful orthodontic outcomes without involving orthognathic surgeries.


Asunto(s)
Maxilar , Técnica de Expansión Palatina , Tornillos Óseos , Análisis de Elementos Finitos , Humanos , Maxilar/cirugía , Hueso Paladar
11.
Am J Orthod Dentofacial Orthop ; 159(4): 460-469, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33526299

RESUMEN

INTRODUCTION: To investigate the anatomy of the posterior palatal alveolar process, which is often used for placement of the orthodontic mini-implant (OMI), and to suggest simple guidelines for safe placement of OMI. METHODS: Cone-beam computed tomography (CBCT) scans of 60 patients (30 men, 30 women; age range, 18-39 years; average age, 25.8 years) was used to measure the palatal interradicular distance, the palatal bone thickness, and the palatal soft-tissue thickness. Measurements were performed on the area from the maxillary canine to the maxillary second molar based on the vertical distance apical from the cementoenamel junction. The CBCT data were analyzed by Bonferroni correction for multiple testing and the multivariable mixed linear model. RESULTS: The palatal interradicular distance was the widest between the second premolar and the first molar and the narrowest between the first and second premolars. The palatal bone thickness at interdental sites was the thickest between the first and second premolars and the thinnest between the first and second molars. The interdental palatal soft-tissue thickness from the canine to the second premolar was thicker than any other area. There were minor measurement differences between genders and positive correlations between vertical distance from the cementoenamel junction plane and all of the parameters. CONCLUSION: In this study, we evaluated the anatomy of the posterior palatal area using CBCT scans of adult patients. The data will provide guidelines to the clinicians before OMI placement in the posterior palatal alveolar process.


Asunto(s)
Implantes Dentales , Métodos de Anclaje en Ortodoncia , Adolescente , Adulto , Proceso Alveolar/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico , Femenino , Humanos , Masculino , Maxilar , Raíz del Diente , Adulto Joven
12.
Metabolomics ; 16(10): 114, 2020 10 12.
Artículo en Inglés | MEDLINE | ID: mdl-33047270

RESUMEN

INTRODUCTION: Ketoacidosis of metabolic disease showed in beef cattle although body weight was increased by high-grain diets (HGDs). However, few studies have examined for health status related with metabolic disease of ketoacidosis following high-protein diet (HPD). OBJECTIVES: Metabolomic analysis was performed for the monitoring of health status associated with metabolic disease of ketoacidosis in the plasma of Hanwoo heifers following a HPD. METHODS: Hanwoo heifers of 24 months with 459 ± 42 kg weight were used under a 2 × 2 crossover design. The plasma was collected from control (n = 5) and HPD group (n = 5) on day 21 following diet adaptation for 20 days. Metabolic profiling analysis of organic acids (OAs), amino acids (AAs) and fatty acids (FAs) by gas chromatography-tandem mass spectrometry combined with star pattern analysis was performed in plasma. Levels of OAs, AAs and FAs were evaluated by Mann-Whitney test, PCA and PLS-DA. RESULTS: In HPD group, ketoacidosis as metabolic disease was monitored by elevated acetoacetic acid and 3-hydroxybutyric acid. In addition, the elevation of ketogenic AAs, reduction of medium chain FAs and OAs with energy metabolism in TCA cycle were monitored in HPD group. Star graphic pattern was characteristic and readily distinguished between control and HPD groups. In PLS-DA, two groups were separated with VIP score of top-ranked 10 FAs as important metabolites for discrimination. CONCLUSION: Elevation of ketone body including ketogenic AAs and reduced energy metabolism of FAs and OAs may useful for evaluation of health states associated with ketoacidosis from metabolic event by HPD in beef cattle.


Asunto(s)
Aminoácidos/sangre , Bovinos/sangre , Cetosis/sangre , Animales , Dieta Rica en Proteínas/efectos adversos , Dieta Rica en Proteínas/veterinaria , Ácidos Grasos/sangre , Femenino , Cromatografía de Gases y Espectrometría de Masas/métodos , Cetosis/diagnóstico , Metabolómica/métodos , República de Corea
13.
Am J Orthod Dentofacial Orthop ; 158(5): 752-758, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32863085

RESUMEN

Nonmineralized cysts and cyst-like lesions that frequently occur in the mandible include ameloblastomas, odontogenic keratocysts, and dentigerous cysts. They have specific features of well-demarcated, unilocular, and radiolucent lesions that are often associated with tooth impaction. Although it rarely occurs, these cysts can become extremely large. Furthermore, cyst enlargement causes additional symptoms that can challenge the success of tooth recovery through orthodontic treatment. This clinical report presents the successful eruption of 2 impacted molars in a large dentigerous cyst treated with marsupialization and orthodontic traction using an orthodontic miniplate anchorage over a 4-year treatment period.


Asunto(s)
Quiste Dentígero , Quistes Odontogénicos , Diente Impactado , Quiste Dentígero/diagnóstico por imagen , Quiste Dentígero/cirugía , Humanos , Diente Molar/diagnóstico por imagen , Diente Molar/cirugía , Erupción Dental , Diente Impactado/diagnóstico por imagen , Diente Impactado/cirugía
14.
Orthod Craniofac Res ; 22(4): 296-303, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31066172

RESUMEN

OBJECTIVES: To evaluate three-dimensional (3D) craniofacial changes induced by a non-surgical tooth-bone-borne rapid palatal expander (TBB-RPE) according to the symmetrical pattern of expansion, to investigate the 3D changes between the sides in patients with asymmetric expansion, and to identify the related factors of asymmetric expansion. SETTING AND SAMPLE POPULATION: Sixty-six patients (mean age: 19.3 ± 5.7 years) treated with TBB-RPE were divided into a symmetric expansion group (Group S, n = 46) or asymmetric expansion group (Group A, n = 20). Group S was subdivided into Group Ss (n = 27), with bilateral frontomaxillary suture (FMS) split, and Group Sn (n = 19), with no FMS split. MATERIALS AND METHODS: Pre- and post-expansion cone-beam computed tomography images were superimposed, and the common coordinated system was set. All landmarks were designated as coordinate pairs, and treatment changes were automatically calculated. Analysis of variance was conducted for intergroup comparison of craniofacial changes, and logistic regression analysis was performed to identify the related factors of asymmetric expansion. RESULTS: The frequency of asymmetric expansion was 30.3%. Group A with unilateral FMS split showed less craniofacial changes than Group Ss and more changes than Group Sn. Group A exhibited different nasomaxillary displacement between the two halves, showing greater changes in the FMS-split side. Among the tested six variables (age, gender, Angle's classification, unilateral crossbite, maxillary cant and chin deviation), chin deviation was uniquely associated with asymmetric expansion. CONCLUSIONS: Tooth-bone-borne rapid palatal expander had a risk of asymmetric expansion, especially in facial asymmetric patients with chin deviation, producing different craniofacial changes from symmetric expansion.


Asunto(s)
Maloclusión , Diente , Adolescente , Adulto , Tomografía Computarizada de Haz Cónico , Humanos , Maxilar , Técnica de Expansión Palatina , Adulto Joven
15.
J Craniofac Surg ; 27(2): e130-3, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26845096

RESUMEN

INTRODUCTION: This article represents a new design of expander-spike expander-to correct transverse maxillary deficiency. This new type appliance is easy to fabricate, more hygienic, and less soft-tissue irritation because of elimination of acrylic plate. In addition, because of the position of mini-implant, it can provide a relatively parallel alveolar expansion, compared with other types of expander. MATERIALS AND METHODS: The spike expander consists of 2 parts: 4 spike screws and an expansion screw. Four spike screws were placed on the palatal slope. After installation of the spike screws, based on the position of spike screw, the extension arms of expansion screw were bended on the cast model, and connected to the spike screws by adding resin. The expansion screw was turned once a day (0.25 mm/d), and the process was terminated at 6 weeks. RESULTS: The stability and design of the spike screw enable widening of maxilla easier. Compared with other expander, spike expander reduces the forces being placed directly on teeth, which can maximize skeletal expansion, minimize dental tipping, produce a relatively parallel expansion, and reduce soft-tissue irritation caused by acrylic pads. Furthermore, the teeth can be aligned and leveled simultaneously using the fixed appliance because teeth are free of contact by the expander. And the best point for spike expander is that it is simply fabricated and removed. CONCLUSIONS: The design of spike expander is combining spike screws and an expansion screw, which can provide a good and easy treatment method for transverse maxillary deficiency.


Asunto(s)
Tornillos Óseos , Maxilar/cirugía , Diseño de Aparato Ortodóncico , Técnica de Expansión Palatina/instrumentación , Adolescente , Humanos , Masculino , Maloclusión/diagnóstico , Maloclusión/cirugía , Maloclusión de Angle Clase III/diagnóstico , Maloclusión de Angle Clase III/cirugía
16.
Nutr Clin Pract ; 2023 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-37735988

RESUMEN

BACKGROUND: Literature on optimal energy provision via parenteral nutrition (PN) is limited and the evidence quality is low. The purpose of this study is to determine if there is a difference in outcomes in adult critically ill patients when receiving lower vs higher calorie provision via PN early in intensive care unit (ICU) stay. METHODS: Adult patients initiated on PN within the first 10 days of ICU stay from May 2014 to June 2021 were included in this retrospective study. The primary outcome was to determine the impact of lower (<20 kcal/kg/day) vs higher (>25 kcal/kg/day) calorie provision on all-cause, in-hospital mortality. Secondary outcomes were to determine the impact of calorie provision on hospital or ICU length of stay and incidence of complications. RESULTS: This study included 133 patients: a lower calorie provision group (n = 77) and a higher calorie provision group (n = 56). There was a significant difference in all-cause, in-hospital mortality between the lower and the higher calorie provision groups (36.36% and 17.86%, respectively; P = 0.02). However, upon a multivariate analysis of death at discharge, the specific calorie provision group did not affect the probability of death at hospital discharge. The secondary outcomes were not significantly different between groups. CONCLUSION: When comparing lower calorie provision with higher calorie provision in adult critically ill patients receiving PN early within their ICU stay, there were no differences in outcomes after controlling for significant confounders. Future larger prospective studies should further evaluate optimal caloric provision via PN in this population.

17.
Innov Pharm ; 14(4)2023.
Artículo en Inglés | MEDLINE | ID: mdl-38495356

RESUMEN

Introduction: The performance of bystander cardiopulmonary resuscitation (CPR) improves survival among cardiac arrest victims. Near-peer teaching of Basic Life Support (BLS) may be an effective way to deliver resuscitation education. This article aims to assess the effectiveness of a student pharmacist-led American Heart Association (AHA) BLS course on high school students' knowledge and skill achievement. Methods: Student pharmacists were trained as AHA instructors and delivered BLS certification courses to high school students. Participants completed pre- and post-assessments adapted from the course learning objectives. Skills performance was evaluated using the AHA's standardized forms. Participants completed questions regarding their perceptions of the pharmacist's role in BLS and confidence in pursuing a career in healthcare. Results: There were 321 participants with the majority in 11th or 12th grade (86.6%) and attending public school (99.1%). After completing the training, the mean percentage of correct assessment responses increased from 41.2% to 89% (p <0.0001). All participants correctly performed BLS skills. Most participants strongly agreed or agreed that the course changed their perspective of the pharmacist's role during BLS (74.8%) and increased their confidence in their decision to pursue future careers in healthcare (61.7%). Conclusion: Student pharmacist-led BLS training, using near-peer delivery, improves high school students' knowledge and skill achievement. This strategy promotes high school students' positive perceptions regarding pharmacists and their role in BLS, as well as their confidence in pursuing careers in healthcare.

18.
Biol Pharm Bull ; 35(9): 1581-7, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22975512

RESUMEN

The 70% ethanol extract of the rhizome of Alisma orientale (Alismatis rhizome) (AOE) was prepared and found to significantly inhibit 5-lipoxygenase (5-LOX)-catalyzed leukotriene (LT) production from rat basophilic leukemia (RBL)-1 cells and ß-hexosaminidase release by antigen-stimulated RBL-2H3 cells. It also attenuated delayed-type hypersensitivity (DTH) reaction in mice. Among the three major triterpene constituents isolated (i.e., alisol B, alisol B 23-acetate, alisol C 23-acetate) as active principles, alisol B and its 23-acetate strongly and significantly inhibited LT production and ß-hexosaminidase release between 1-10 µM. On the other hand, all these alisol derivatives significantly and strongly inhibited DTH response after oral administration. In addition, AOE (200 mg/kg/d) was for the first time found to considerably alleviate hapten-induced dermatitis symptoms in NC/Nga mice, an animal model of atopic dermatitis. These results indicate that alisol derivatives possess inhibitory activities on immediate-type as well as delayed-type hypersensitivity reactions and may contribute to the anti-allergic action of AOE.


Asunto(s)
Alisma/química , Colestenonas/uso terapéutico , Dermatitis Atópica/prevención & control , Hipersensibilidad Tardía/prevención & control , Fitoterapia , Extractos Vegetales/uso terapéutico , Animales , Antígenos/metabolismo , Araquidonato 5-Lipooxigenasa/metabolismo , Línea Celular Tumoral , Colestenonas/farmacología , Dermatitis Atópica/metabolismo , Modelos Animales de Enfermedad , Haptenos/metabolismo , Hipersensibilidad Tardía/metabolismo , Leucemia , Leucotrienos/biosíntesis , Masculino , Ratones , Ratones Endogámicos ICR , Ratones Endogámicos , Extractos Vegetales/farmacología , Rizoma/química , beta-N-Acetilhexosaminidasas/metabolismo
19.
Pharmacy (Basel) ; 10(4)2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35893714

RESUMEN

Pharmacists must integrate foundational sciences with pharmacy practice for providing optimal patient care. Pharmacy students need to be trained to provide culturally competent, linguistically accessible, and empathetic care while integrating foundational science principles. However, such holistic integration is challenging to achieve and assess. To bridge this gap, we implemented and assessed an "integrated cardiovascular simulation" (ICS) module for P2 students, employing case-based and team-based learning. ICS focused on congestive heart failure with preexisting arrhythmia and incorporated patient counseling relating to diversity factors such as cultural competency, linguistic challenges, and the impact of population diversity on cardiac diseases. Students learned the SBAR communication technique (situation, background, assessment, and recommendation) and recommended therapy while elaborating on drug MOA and adverse effects. ICS was assessed through pre-and post-session quizzes and perception data immediately after the activity, and after two years, when students progressed to the cardiovascular APPE block. Student performance improved on a post-test (80.2%) compared to the pre-test (66.9%), p < 0.01 paired student t-test, with an increase in symptom and arrhythmia pattern recognition (41.2% and 36.7%, respectively). ICS was effective for teaching (1) arrhythmia pathophysiology (85%), (2) EKG interpretation (89%), (3) drug adverse effects (93%), (4) DEI-clinical decision making (92%), and (5) communication skills (85%).

20.
Sci Rep ; 12(1): 6139, 2022 04 12.
Artículo en Inglés | MEDLINE | ID: mdl-35414687

RESUMEN

This study evaluated dental caries detection ability between the Qraycam and Qraypen on the same dental caries lesions. A total of 178teeth from 61patients were imaged using Qraypen C®(QC) and Qraycam Pro®(QP) devices and evaluated using analysis software (QA2). Occlusal, secondary, and proximal dental caries were evaluated and scored according to International Caries Detection and Assessment System(ICDAS II) and X-ray criteria. Bland-Altman plots were used to compare quantitative light-induced fluorescence(QLF) parameters obtained from the different QLF devices. Sensitivity, specificity, and area under the receiver operating characteristic curve(AUROC) were calculated. The ΔFaver. of the QLF-parameters showed that the mean difference between the two different QLF devices was close to zero and that the ± 5 error value was included in the mean ± 1.96SD range for the detection of dental caries. The accuracies for diagnosing occlusal dental caries were 0.83-0.96 and 0.81-0.82 and the accuracies for diagnosing proximal dental caries were 0.52-0.62 and 0.52-0.71 for the QC and QP devices, respectively. In conclusion, the ΔFaver. obtained from the QP showed diagnostic value mainly for screening of demineralized teeth. For teeth selected through screening, the depth of the lesion must be precisely evaluated using additional QP and radiographic imaging.


Asunto(s)
Caries Dental , Fluorescencia Cuantitativa Inducida por la Luz , Diente , Caries Dental/diagnóstico por imagen , Caries Dental/patología , Fluorescencia , Humanos , Tamizaje Masivo , Curva ROC , Sensibilidad y Especificidad , Diente/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA