Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.158
Filtrar
Más filtros

Intervalo de año de publicación
1.
N Engl J Med ; 389(14): 1286-1297, 2023 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-37634145

RESUMEN

BACKGROUND: Extracorporeal life support (ECLS) is increasingly used in the treatment of infarct-related cardiogenic shock despite a lack of evidence regarding its effect on mortality. METHODS: In this multicenter trial, patients with acute myocardial infarction complicated by cardiogenic shock for whom early revascularization was planned were randomly assigned to receive early ECLS plus usual medical treatment (ECLS group) or usual medical treatment alone (control group). The primary outcome was death from any cause at 30 days. Safety outcomes included bleeding, stroke, and peripheral vascular complications warranting interventional or surgical therapy. RESULTS: A total of 420 patients underwent randomization, and 417 patients were included in final analyses. At 30 days, death from any cause had occurred in 100 of 209 patients (47.8%) in the ECLS group and in 102 of 208 patients (49.0%) in the control group (relative risk, 0.98; 95% confidence interval [CI], 0.80 to 1.19; P = 0.81). The median duration of mechanical ventilation was 7 days (interquartile range, 4 to 12) in the ECLS group and 5 days (interquartile range, 3 to 9) in the control group (median difference, 1 day; 95% CI, 0 to 2). The safety outcome consisting of moderate or severe bleeding occurred in 23.4% of the patients in the ECLS group and in 9.6% of those in the control group (relative risk, 2.44; 95% CI, 1.50 to 3.95); peripheral vascular complications warranting intervention occurred in 11.0% and 3.8%, respectively (relative risk, 2.86; 95% CI, 1.31 to 6.25). CONCLUSIONS: In patients with acute myocardial infarction complicated by cardiogenic shock with planned early revascularization, the risk of death from any cause at the 30-day follow-up was not lower among the patients who received ECLS therapy than among those who received medical therapy alone. (Funded by the Else Kröner Fresenius Foundation and others; ECLS-SHOCK ClinicalTrials.gov number, NCT03637205.).


Asunto(s)
Oxigenación por Membrana Extracorpórea , Infarto del Miocardio , Choque Cardiogénico , Humanos , Oxigenación por Membrana Extracorpórea/efectos adversos , Oxigenación por Membrana Extracorpórea/mortalidad , Infarto del Miocardio/complicaciones , Infarto del Miocardio/terapia , Estudios Retrospectivos , Riesgo , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Resultado del Tratamiento , Revascularización Miocárdica
2.
Am J Respir Crit Care Med ; 209(4): 417-426, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-37943110

RESUMEN

Rationale: Definitive guidelines for anticoagulation management during veno-venous extracorporeal membrane oxygenation (VV ECMO) are lacking, whereas bleeding complications continue to pose major challenges. Objectives: To describe anticoagulation modalities and bleeding events in adults receiving VV ECMO. Methods: This was an international prospective observational study in 41 centers, from December 2018 to February 2021. Anticoagulation was recorded daily in terms of type, dosage, and monitoring strategy. Bleeding events were reported according to site, severity, and impact on mortality. Measurements and Main Results: The study cohort included 652 patients, and 8,471 days on ECMO were analyzed. Unfractionated heparin was the initial anticoagulant in 77% of patients, and the most frequently used anticoagulant during the ECMO course (6,221 d; 73%). Activated partial thromboplastin time (aPTT) was the most common test for monitoring coagulation (86% of days): the median value was 52 seconds (interquartile range, 39 to 61 s) but dropped by 5.3 seconds after the first bleeding event (95% confidence interval, -7.4 to -3.2; P < 0.01). Bleeding occurred on 1,202 days (16.5%). Overall, 342 patients (52.5%) experienced at least one bleeding event (one episode every 215 h on ECMO), of which 10 (1.6%) were fatal. In a multiple penalized Cox proportional hazard model, higher aPTT was a potentially modifiable risk factor for the first episode of bleeding (for 20-s increase; hazard ratio, 1.07). Conclusions: Anticoagulation during VV ECMO was a dynamic process, with frequent stopping in cases of bleeding and restart according to the clinical picture. Future studies might explore lower aPTT targets to reduce the risk of bleeding.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Heparina , Adulto , Humanos , Heparina/efectos adversos , Oxigenación por Membrana Extracorpórea/efectos adversos , Coagulación Sanguínea , Hemorragia/inducido químicamente , Hemorragia/terapia , Anticoagulantes/efectos adversos , Estudios Retrospectivos
3.
Proc Natl Acad Sci U S A ; 119(13): e2115276119, 2022 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-35312360

RESUMEN

SignificanceThe treatment of hypoxemia that is refractory to the current standard of care is time-sensitive and requires skilled caregivers and use of specialized equipment (e.g., extracorporeal membrane oxygenation). Most patients experiencing refractory hypoxemia will suffer organ dysfunction, and death is common in this cohort. Here, we describe a new strategy to stabilize and support patients using a microfluidic device that administers oxygen gas directly to the bloodstream in real time and on demand using a process that we call sequential shear-induced bubble breakup. If successful, the described technology may help to avoid or decrease the incidence of ventilator-related lung injury from refractory hypoxemia.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Lesión Pulmonar , Oxigenación por Membrana Extracorpórea/efectos adversos , Humanos , Hipoxia , Dispositivos Laboratorio en un Chip , Oxígeno , Ventiladores Mecánicos/efectos adversos
4.
Circulation ; 147(16): 1237-1250, 2023 04 18.
Artículo en Inglés | MEDLINE | ID: mdl-37068133

RESUMEN

Venoarterial extracorporeal membrane oxygenation provides cardiorespiratory support to patients in cardiogenic shock. This comes at the cost of increased left ventricle (LV) afterload that can be partly ascribed to retrograde aortic flow, causing LV distension, and leads to complications including cardiac thrombi, arrhythmias, and pulmonary edema. LV unloading can be achieved by using an additional circulatory support device to mitigate the adverse effects of mechanical overload that may increase the likelihood of myocardial recovery. Observational data suggest that these strategies may improve outcomes, but in whom, when, and how LV unloading should be employed is unclear; all techniques require balancing presumed benefits against known risks of device-related complications. This review summarizes the current evidence related to LV unloading with venoarterial extracorporeal membrane oxygenation.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Corazón Auxiliar , Humanos , Oxigenación por Membrana Extracorpórea/efectos adversos , Oxigenación por Membrana Extracorpórea/métodos , Corazón Auxiliar/efectos adversos , Ventrículos Cardíacos/diagnóstico por imagen , Choque Cardiogénico/terapia , Miocardio
5.
Lancet ; 402(10410): 1338-1346, 2023 10 14.
Artículo en Inglés | MEDLINE | ID: mdl-37643628

RESUMEN

BACKGROUND: Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is increasingly used in patients with cardiogenic shock despite the lack of evidence from adequately powered randomised clinical trials. Three trials reported so far were underpowered to detect a survival benefit; we therefore conducted an individual patient-based meta-analysis to assess the effect of VA-ECMO on 30-day death rate. METHODS: Randomised clinical trials comparing early routine use of VA-ECMO versus optimal medical therapy alone in patients presenting with infarct-related cardiogenic shock were identified by searching MEDLINE, Cochrane Central Register of Controlled Trials, Embase, and trial registries until June 12, 2023. Trials were included if at least all-cause death rate 30 days after in-hospital randomisation was reported and trial investigators agreed to collaborate (ie, providing individual patient data). Odds ratios (ORs) as primary outcome measure were pooled using logistic regression models. This study is registered with PROSPERO (CRD42023431258). FINDINGS: Four trials (n=567 patients; 284 VA-ECMO, 283 control) were identified and included. Overall, there was no significant reduction of 30-day death rate with the early use of VA-ECMO (OR 0·93; 95% CI 0·66-1·29). Complication rates were higher with VA-ECMO for major bleeding (OR 2·44; 95% CI 1·55-3·84) and peripheral ischaemic vascular complications (OR 3·53; 95% CI 1·70-7·34). Prespecified subgroup analyses were consistent and did not show any benefit for VA-ECMO (pinteraction ≥0·079). INTERPRETATION: VA-ECMO did not reduce 30-day death rate compared with medical therapy alone in patients with infarct-related cardiogenic shock, and an increase in major bleeding and vascular complications was observed. A careful review of the indication for VA-ECMO in this setting is warranted. FUNDING: Foundation Institut für Herzinfarktforschung.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Choque Cardiogénico , Humanos , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Oxigenación por Membrana Extracorpórea/efectos adversos , Contrapulsador Intraaórtico , Modelos Logísticos , Hemorragia/etiología , Estudios Retrospectivos , Ensayos Clínicos Controlados Aleatorios como Asunto
6.
Crit Care Med ; 52(1): 54-67, 2024 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-37665263

RESUMEN

OBJECTIVE: Analysis of the prevalence and risk factors for weaning failure from venovenous extracorporeal membrane oxygenation (VV-ECMO) in patients with severe acute respiratory insufficiency. DESIGN: Single-center retrospective observational study. SETTING: Sixteen beds medical ICU at the University Hospital Regensburg. PATIENTS: Two hundred twenty-seven patients with severe acute respiratory insufficiency requiring VV-ECMO support between October 2011 and December 2017. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Patients meeting our ECMO weaning criteria (Sp o2 ≥ 90% with F io2 ≤ 0.4 or Pa o2 /F io2 > 150 mm Hg, pH = 7.35-7.45, positive end-expiratory pressure ≤ 10 cm H 2 O, driving pressure < 15 cm H 2 O, respiratory rate < 30/min, tidal volume > 5 mL/kg, ECMO bloodflow ≈ 1. 5 L/min, sweep gas flow ≈ 1 L/min, heart rate < 120/min, systolic blood pressure 90-160 mm Hg, norepinephrine < 0.2 µg/[kg*min]) underwent an ECMO weaning trial (EWT) with pausing sweep gas flow. Arterial blood gas analysis, respiratory and ventilator parameters were recorded prior, during, and after EWTs. Baseline data, including demographics, vitals, respiratory, ventilator, and laboratory parameters were recorded at the time of cannulation. One hundred seventy-nine of 227 (79%) patients were successfully decannulated. Ten patients (4%) underwent prolonged weaning of at least three failed EWTs before successful decannulation. The respiratory rate (19/min vs 16/min, p = 0.002) and Pa co2 (44 mm Hg vs 40 mm Hg, p = 0.003) were higher before failed than successful EWTs. Both parameters were risk factors for ECMO weaning failure (Pa co2 : odds ratio [OR] 1.05; 95% CI, 1.001-1.10; p = 0.045; respiratory rate: OR 1.10; 95% CI, 1.04-1.15; p < 0.001) in multivariable analysis. The rapid shallow breathing index [42 (1/L*min), vs 35 (1/L*min), p = 0.052) was higher before failed than successful EWTs. The decline of Sa o2 and Pa o2 /F io2 during EWTs was higher in failed than successful trials. CONCLUSIONS: Seventy-nine percent of patients were successfully decannulated with only 4% needing prolonged ECMO weaning. Before EWT only parameters of impaired ventilation (insufficient decarboxylation, higher respiratory rate) but not of oxygenation were predictive for weaning failure, whereas during EWT-impaired oxygenation was associated with weaning failure.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Síndrome de Dificultad Respiratoria , Insuficiencia Respiratoria , Humanos , Oxigenación por Membrana Extracorpórea/efectos adversos , Prevalencia , Dióxido de Carbono , Desconexión del Ventilador , Síndrome de Dificultad Respiratoria/epidemiología , Síndrome de Dificultad Respiratoria/terapia , Síndrome de Dificultad Respiratoria/etiología , Factores de Riesgo , Estudios Retrospectivos , Insuficiencia Respiratoria/epidemiología , Insuficiencia Respiratoria/terapia , Insuficiencia Respiratoria/etiología
7.
Semin Thromb Hemost ; 50(2): 253-270, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37640048

RESUMEN

Extracorporeal membrane oxygenation (ECMO) is a life-support technique used to treat cardiac and pulmonary failure, including severe cases of COVID-19 (coronavirus disease 2019) involving acute respiratory distress syndrome. Blood clot formation in the circuit is one of the most common complications in ECMO, having potentially harmful and even fatal consequences. It is therefore essential to regularly monitor for clots within the circuit and take appropriate measures to prevent or treat them. A review of the various methods used by hospital units for detecting blood clots is presented. The benefits and limitations of each method are discussed, specifically concerning detecting blood clots in the oxygenator, as it is concluded that this is the most critical and challenging ECMO component to assess. We investigate the feasibility of solutions proposed in the surrounding literature and explore two areas that hold promise for future research: the analysis of small-scale pressure fluctuations in the circuit, and real-time imaging of the oxygenator. It is concluded that the current methods of detecting blood clots cannot reliably predict clot volume, and their inability to predict clot location puts patients at risk of thromboembolism. It is posited that a more in-depth analysis of pressure readings using machine learning could better provide this information, and that purpose-built imaging could allow for accurate, real-time clotting analysis in ECMO components.


Asunto(s)
COVID-19 , Oxigenación por Membrana Extracorpórea , Trombosis , Humanos , Oxigenación por Membrana Extracorpórea/efectos adversos , Oxigenación por Membrana Extracorpórea/métodos , Trombosis/diagnóstico , Trombosis/etiología , Coagulación Sanguínea , Pruebas de Coagulación Sanguínea , Oxigenadores/efectos adversos , COVID-19/complicaciones
8.
Transfusion ; 64(3): 475-482, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38385665

RESUMEN

BACKGROUND: Adult extracorporeal membrane oxygenation (ECMO) patients are at high risk for allogeneic blood transfusion. Few studies have characterized iatrogenic blood loss from phlebotomy in adult ECMO patients. We hypothesized that iatrogenic phlebotomy would be a significant source of blood loss during ECMO. METHODS: Adults who had their entire ECMO run at our medical center between 2020 and 2022 were included. Average daily phlebotomy volume and total phlebotomy volume during ECMO were estimated based on the total number of laboratory tests that were processed. In addition, the crude and adjusted association between total phlebotomy volume during ECMO and RBC transfusion during ECMO was evaluated using linear regression and Loess curve analysis. RESULTS: A total of 161 patients who underwent 162 ECMO runs were included. Of the 162 ECMO runs, 88 (54.3%) were veno-arterial and 74 (45.7%) were veno-venous ECMO. Median duration of ECMO was 5 days [25th, 75th percentile = 2, 11]. Median daily phlebotomy volume was 130 mLs [25th, 75th percentile = 94, 170] and median total phlebotomy volume during ECMO was 579 mLs [25th, 75th percentile = 238, 1314]. There was a significant crude and adjusted association between total phlebotomy volume and RBC transfusion during ECMO (beta coefficient = 0.0023 and 0.0024 respectively, both p < .001) based on linear regression analysis. DISCUSSION: Phlebotomy for laboratory testing is a significant source of blood loss during ECMO in adults. Comprehensive patient blood management for adult ECMO patients should include strategies to reduce laboratory testing and/or phlebotomy volume during ECMO.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Accidente Cerebrovascular , Adulto , Humanos , Flebotomía/efectos adversos , Oxigenación por Membrana Extracorpórea/efectos adversos , Estudios Retrospectivos , Transfusión Sanguínea , Hemorragia/etiología , Hemorragia/terapia , Enfermedad Iatrogénica
9.
Catheter Cardiovasc Interv ; 103(3): 472-481, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38197216

RESUMEN

BACKGROUND: There is considerable debate about the hemodynamic effects of veno-arterial extracorporeal membrane oxygenation (VA-ECMO). AIMS: To evaluate the changes in left ventricular (LV) function, volumes, and work in patients treated with VA-ECMO using invasive LV catheterization and three-dimensional echocardiographic volumes. METHODS: Patients on VA-ECMO underwent invasive hemodynamic evaluation due to concerns regarding candidacy for decannulation. Hemodynamic parameters were reported as means±standard deviations or medians (interquartile ranges) after evaluating for normality. Paired comparisons were done to evaluate hemodynamics at the baseline (highest) and lowest tolerated levels of VA-ECMO support. RESULTS: Twenty patients aged 52.3 ± 15.8 years were included. All patients received VA-ECMO for refractory cardiogenic shock (5/20 SCAI stage D, 15/20 SCAI stage E). At 3.0 (2.0, 4.0) days after VA-ECMO cannulation, the baseline LV ejection fraction was 20% (15%, 27%). The baseline and lowest VA-ECMO flows were 4.0 ± 0.6 and 1.5 ± 0.6 L/min, respectively. Compared to the lowest flow, full VA-ECMO support reduced LV end-diastolic volume [109 ± 81 versus 134 ± 93 mL, p = 0.001], LV end-diastolic pressure (14 ± 9 vs. 19 ± 9 mmHg, p < 0.001), LV stroke work (1858 ± 1413 vs. 2550 ± 1486 mL*mmHg, p = 0.002), and LV pressure-volume area (PVA) (4507 ± 1910 vs. 5193 ± 2388, p = 0.03) respectively. Mean arterial pressure was stable at the highest and lowest flows (80 ± 16 vs. 75 ± 14, respectively; p = 0.08) but arterial elastance was higher at the highest VA-ECMO flow (4.9 ± 2.2 vs lowest flow 2.7 ± 1.6; p < 0.001). CONCLUSIONS: High flow VA-ECMO support significantly reduced LV end-diastolic pressure, end-diastolic volume, stroke work, and PVA compared to minimal support. The Ea was higher and MAP was stable or minimally elevated on high flow.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Humanos , Oxigenación por Membrana Extracorpórea/efectos adversos , Resultado del Tratamiento , Choque Cardiogénico/diagnóstico por imagen , Choque Cardiogénico/terapia , Hemodinámica , Ventrículos Cardíacos
10.
Anesthesiology ; 141(1): 75-86, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38502917

RESUMEN

BACKGROUND: Extracorporeal membrane oxygenation (ECMO) is associated with a high risk of bleeding complications. The specific impact of ECMO on fibrinolysis remains unexplored. The objective of the current pilot observational prospective study was to investigate the longitudinal dynamics of fibrinolytic markers-i.e., changes over time-in the context of bleeding events in patients on ECMO. METHODS: Longitudinal dynamics of contact phase components (kininogen and bradykinin) and fibrinolysis markers (tissue plasminogen activator [tPA], plasminogen activator inhibitor-1 [PAI-1], their complexes [tPA•PAI-1], plasmin-antiplasmin complexes, plasminogen, and D-dimer) were measured in patients undergoing venovenous and venoarterial ECMO, before implantation, at 0, 6, and 12 h after implantation, and daily thereafter. RESULTS: The cohort consisted of 30 patients (214 ECMO days). The concentrations of tPA, D-dimer, plasmin-antiplasmin complexes, PAI-1, and tPA•PAI-1 complexes were increased, whereas plasminogen decreased compared to normal values. A noteworthy divergence was observed between hemorrhagic and nonhemorrhagic patients: in bleeding patients, D-dimer, plasmin-antiplasmin, tPA, PAI-1, and tPA•PAI-1 followed an increasing kinetics before hemorrhage and then decreased to their baseline level; conversely, nonbleeding patients showed a decreasing kinetics in these markers. Also, D-dimer and tPA followed an increasing kinetics in bleeding patients compared to nonbleeding patients (median values for D-dimer dynamics: 1,080 vs. -440 ng/ml, P = 0.05; tPA dynamics: 0.130 vs. 0.100 nM, P = 0.038), and both markers significantly increased the day before hemorrhage. A tPA concentration above 0.304 nM was associated with bleeding events (odds ratio, 4.92; 95% CI, 1.01 to 24.08; P = 0.049). CONCLUSIONS: Contact activation induces fibrinolysis in ECMO patients, especially in patients experiencing bleeding. This finding supports the role of this mechanism as a possible causal factor for hemorrhages during ECMO and open new avenues for novel therapeutic perspectives.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Fibrinólisis , Humanos , Oxigenación por Membrana Extracorpórea/efectos adversos , Oxigenación por Membrana Extracorpórea/métodos , Proyectos Piloto , Fibrinólisis/fisiología , Estudios Prospectivos , Masculino , Femenino , Persona de Mediana Edad , Adulto , Hemorragia/etiología , Hemorragia/sangre , Hemorragia/terapia , Activador de Tejido Plasminógeno/sangre , Biomarcadores/sangre , Inhibidor 1 de Activador Plasminogénico/sangre , Anciano , Productos de Degradación de Fibrina-Fibrinógeno/análisis , Productos de Degradación de Fibrina-Fibrinógeno/metabolismo , Estudios de Cohortes
11.
Vox Sang ; 119(4): 326-334, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38175143

RESUMEN

BACKGROUND AND OBJECTIVES: Extracorporeal membrane oxygenation (ECMO) serves as cardiopulmonary therapy in critically ill patients with respiratory/heart failure and often necessitates multiple blood product transfusions. The administration of platelet transfusions during ECMO is triggered by the presence or risk of significant bleeding. Most paediatric ECMO programmes follow guidelines that recommend a platelet transfusion threshold of 80-100 × 109/L. To reduce exposure to platelets, we developed a practice to dynamically lower the threshold to ~20 × 109/L. We describe our experience with patient-tailored platelet thresholds and related bleeding outcomes. MATERIALS AND METHODS: We retrospectively evaluated our platelet transfusion policy, bleeding complications and patient outcome in 229 ECMO-supported paediatric patients in our unit. RESULTS: We found that more than 97.4% of patients had a platelet count <100 × 109/L at some point during their ECMO course. Platelets were transfused only on 28.5% of ECMO days; and 19.2% of patients never required a platelet transfusion. The median lowest platelet count in children who had bleeding events was 25 × 109/L as compared to 33 × 109/L in children who did not bleed (p < 0.001). Our patients received fewer platelet transfusions and did not require more red blood cell transfusions, nor did they experience more haemorrhagic complications. CONCLUSION: We have shown that a restrictive, 'patient-tailored' rather than 'goal-directed' platelet transfusion policy is feasible and safe, which can greatly reduce the use of platelet products. Although there was a difference in the lowest platelet counts in children who bled versus those who did not, the median counts were much lower than current recommendations.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Transfusión de Plaquetas , Humanos , Niño , Oxigenación por Membrana Extracorpórea/efectos adversos , Estudios Retrospectivos , Transfusión Sanguínea , Hemorragia/etiología , Hemorragia/terapia
12.
Eur J Haematol ; 112(4): 566-576, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38088062

RESUMEN

OBJECTIVES: We aimed to evaluate thrombotic and hemorrhagic complications with heparin versus bivalirudin use in veno-venous extracorporeal membrane oxygenation (V-V ECMO). METHODS: We performed a retrospective cohort study of adult patients placed on V-V ECMO with intravenous anticoagulation with either heparin or bivalirudin. Time to thrombotic event and major bleed were analyzed in addition to related outcomes. RESULTS: We identified 95 patients placed on V-V ECMO: 61 receiving heparin, 34 bivalirudin. The bivalirudin group had a higher rate of severe COVID-19, higher BMI, and longer ECMO duration. Despite this, bivalirudin was associated with reduced risk of thrombotic event (HR 0.14, 95% CI 0.06-0.32, p < .001) and increased average lifespan of the circuit membrane lung (16 vs. 10 days, p = 0.004). While there was no difference in major bleeding, the bivalirudin group required fewer transfusions of packed red blood cells and platelets per 100 ECMO days (means of 13 vs. 39, p = 0.004; 5 vs. 19, p = .014, respectively). Lastly, the bivalirudin group had improved survival to ECMO decannulation in univariate analysis (median OS 53 vs. 26 days, p = .015). CONCLUSIONS: In this real-world analysis of bivalirudin versus heparin, bivalirudin is a viable option for V-V ECMO and associated with lower risk of thrombotic complications and fewer transfusion requirements.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Hirudinas , Trombosis , Adulto , Humanos , Heparina/efectos adversos , Anticoagulantes/efectos adversos , Oxigenación por Membrana Extracorpórea/efectos adversos , Estudios Retrospectivos , Hemorragia/etiología , Hemorragia/terapia , Fragmentos de Péptidos/efectos adversos , Trombosis/tratamiento farmacológico , Trombosis/etiología , Proteínas Recombinantes/efectos adversos
13.
J Surg Res ; 298: 94-100, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38593603

RESUMEN

INTRODUCTION: Extracorporeal membrane oxygenation (ECMO)-associated compartment syndrome (CS) is a rare complication seen in critically ill patients. The epidemiology and management of ECMO-associated CS in the upper extremity (UE) and lower extremity (LE) are poorly defined in the literature. We sought to determine the epidemiology and characterize treatment and outcomes of UE-CS compared to LE-CS in the setting of ECMO therapy. METHODS: Adult patients undergoing ECMO therapy were identified in the Nationwide Readmission Database (2015-2019) and followed up for 6 months. Patients were stratified based on UE-CS versus LE-CS. Primary outcomes were fasciotomy and amputation. All-cause mortality and length of stay were also collected. Risk-adjusted modeling was performed to determine patient- and hospital-level factors associated with differences in the management UE-CS versus LE-CS while controlling for confounders. RESULTS: A total of 24,047 cases of ECMO during hospitalization were identified of which 598 were complicated by CS. Of this population, 507 cases were in the LE (84.8%), while 91 (15.5%) were in the UE. After multivariate analysis, UE-CS patients were less likely to undergo fasciotomy (50.5 vs. 70.9; P = 0.013) and were less likely to undergo amputation of the extremity (3.3 vs. 23.7; P = 0.001) although there was no difference in mortality (58.4 vs. 65.4; P = 0.330). CONCLUSIONS: ECMO patients with CS experience high mortality and morbidity. UE-CS has lower rates of fasciotomy and amputations, compared to LE-CS, with similar mortality. Further studies are needed to elucidate the reasons for these differences.


Asunto(s)
Síndromes Compartimentales , Bases de Datos Factuales , Oxigenación por Membrana Extracorpórea , Fasciotomía , Humanos , Oxigenación por Membrana Extracorpórea/estadística & datos numéricos , Oxigenación por Membrana Extracorpórea/efectos adversos , Masculino , Síndromes Compartimentales/etiología , Síndromes Compartimentales/epidemiología , Síndromes Compartimentales/terapia , Síndromes Compartimentales/mortalidad , Síndromes Compartimentales/cirugía , Femenino , Persona de Mediana Edad , Bases de Datos Factuales/estadística & datos numéricos , Fasciotomía/estadística & datos numéricos , Adulto , Anciano , Amputación Quirúrgica/estadística & datos numéricos , Estudios Retrospectivos , Estados Unidos/epidemiología , Extremidad Inferior/irrigación sanguínea , Extremidad Superior , Tiempo de Internación/estadística & datos numéricos , Resultado del Tratamiento
14.
J Surg Res ; 299: 290-297, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38788465

RESUMEN

INTRODUCTION: More than 1.2 million pulmonary artery catheters (PACs) are used in cardiac patients per annum within the United States. However, it is contraindicated in traditional 1.5 and 3T magnetic resonance imaging (MRI) scans. We aimed to test preclinical and clinical safety of using this imaging modality given the potential utility of needing it in the clinical setting. METHODS: We conducted two phantom experiments to ensure that the electromagnetic field power deposition associated with bare and jacketed PACs was safe and within the acceptable limit established by the Food and Drug Administration. The primary end points were the safety and feasibility of performing Point-of-Care (POC) MRI without imaging-related adverse events. We performed a preclinical computational electromagnetic simulation and evaluated these findings in nine patients with PACs on veno-arterial extracorporeal membrane oxygenation. RESULTS: The phantom experiments showed that the baseline point specific absorption rate through the head averaged 0.4 W/kg. In both the bare and jacketed catheters, the highest net specific absorption rates were at the neck entry point and tip but were negligible and unlikely to cause any heat-related tissue or catheter damage. In nine patients (median age 66, interquartile range 42-72 y) with veno-arterial extracorporeal membrane oxygenation due to cardiogenic shock and PACs placed for close hemodynamic monitoring, POC MRI was safe and feasible with good diagnostic imaging quality. CONCLUSIONS: Adult ECMO patients with PACs can safely undergo point-of-care low-field (64 mT) brain MRI within a reasonable timeframe in an intensive care unit setting to assess for acute brain injury that might otherwise be missed with conventional head computed tomography.


Asunto(s)
Encéfalo , Cateterismo de Swan-Ganz , Oxigenación por Membrana Extracorpórea , Imagen por Resonancia Magnética , Fantasmas de Imagen , Sistemas de Atención de Punto , Humanos , Masculino , Persona de Mediana Edad , Imagen por Resonancia Magnética/efectos adversos , Imagen por Resonancia Magnética/métodos , Femenino , Oxigenación por Membrana Extracorpórea/instrumentación , Oxigenación por Membrana Extracorpórea/efectos adversos , Oxigenación por Membrana Extracorpórea/métodos , Anciano , Adulto , Encéfalo/diagnóstico por imagen , Cateterismo de Swan-Ganz/instrumentación , Cateterismo de Swan-Ganz/efectos adversos , Estudios de Factibilidad
15.
BMC Infect Dis ; 24(1): 228, 2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38378534

RESUMEN

BACKGROUND: Hematopoietic stem cell transplantation (HSCT) was associated with potentially life-threatening complications. Among patients supported by extracorporeal membrane oxygenation (ECMO), those who underwent HSCT had a worse prognosis than those who did not. Advances in HSCT and critical care management have improved the prognosis of ECMO-supported HSCT patients. CASE: The patient in the remission stage of lymphoma after 22 months of allogeneic hematopoietic stem cell transplantation, suffered from ARDS, severe neutropenia, thrombocytopenia, and long-term COVID-19. We evaluated the benefits and risks of ECMO for the patient, including the possibility of being free from ECMO, the status of malignancy, the interval from HSCT to ARDS, the function of the graft, the amount of organ failure, and the comorbidities. ECMO was ultimately used to save his life. CONCLUSIONS: We did not advocate for the general use of ECMO in HSCT patients and we believed that highly selected patients, with well-controlled tumors, few comorbidities, and fewer risk factors for death, tended to benefit from ECMO with well ICU management.


Asunto(s)
COVID-19 , Oxigenación por Membrana Extracorpórea , Trasplante de Células Madre Hematopoyéticas , Neoplasias , Neutropenia , Síndrome de Dificultad Respiratoria , Trombocitopenia , Humanos , Oxigenación por Membrana Extracorpórea/efectos adversos , COVID-19/terapia , COVID-19/complicaciones , Síndrome de Dificultad Respiratoria/etiología , Trombocitopenia/terapia , Trombocitopenia/complicaciones , Neutropenia/complicaciones , Neutropenia/terapia , Neoplasias/complicaciones , Trasplante de Células Madre Hematopoyéticas/efectos adversos
16.
Transpl Int ; 37: 12752, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38585623

RESUMEN

Background: Extracorporeal membrane oxygenation (ECMO) is frequently used during lung transplantation. Unfractionated heparin (UFH) is mainly used as part of ECMO support for anticoagulation. One of the most common perioperative complications is bleeding, which high-dose UFH can aggravate. Methods: We retrospectively analyzed (n = 141) patients who underwent lung transplantation between 2020 and 2022. All subjects (n = 109) underwent central cannulated VA ECMO with successful intraoperative ECMO weaning. Patients on ECMO bridge, postoperative ECMO, heart-lung transplants and transplants without ECMO were excluded. The dose of UFH for the entire surgical procedure, blood loss and consumption of blood derivatives intraoperatively and 48 h after ICU admission were recorded. Surgical revision for postoperative bleeding were analyzed. Thrombotic complications, mortality and long-term survival were evaluated. Results: Lower doses of UFH administered for intraoperative ECMO anticoagulation contribute to a reduction in intraoperative blood derivates consumption and blood loss with no thrombotic complications related to the patient or the ECMO circuit. Lower doses of UFH may lead to a decreased incidence of surgical revision for hemothorax. Conclusion: Lower doses of UFH as part of intraoperative ECMO anticoagulation might reduce the incidence of complications and lead to better postoperative outcomes.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Trasplante de Pulmón , Trombosis , Humanos , Heparina/uso terapéutico , Estudios Retrospectivos , Oxigenación por Membrana Extracorpórea/efectos adversos , Anticoagulantes/uso terapéutico , Trasplante de Pulmón/métodos , Trombosis/etiología , Hemorragia Posoperatoria
17.
Ann Pharmacother ; 58(4): 383-390, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37401103

RESUMEN

BACKGROUND: Only some studies have directly compared and analyzed the roles of activated partial thromboplastin time (aPTT) and activated clotting time (ACT) in coagulation monitoring during argatroban administration. OBJECTIVES: This study aims to assess the correlation of argatroban dose with ACT and aPTT values and to identify the optimal coagulation test for argatroban dose adjustment. METHODS: We evaluated 55 patients on extracorporeal membrane oxygenation (ECMO) who received argatroban for more than 72 hours. The correlation between argatroban dose and aPTT and ACT values was evaluated. To compare argatroban dose and bleeding events according to liver dysfunction, the patients were divided into 2 groups based on alanine aminotransferase and total bilirubin. RESULTS: Among the 55 patients, a total of 459 doses and coagulation tests were evaluated. The aPTT and ACT values showed a weak correlation with argatroban dose, with the Pearson correlation coefficients of 0.261 (P < 0.001) and 0.194 (P = 0.001), respectively. The agreement between the target 150 to 180 seconds for ACT and 55 to 75 seconds for aPTT was observed in 140 patients (46.1%). Twenty-four patients (43.6%) had liver dysfunction when they started argatroban. The median argatroban dose was lower in the liver dysfunction group than in the control group (0.094 mcg/kg/min vs 0.169 mcg/kg/min, P = 0.020). Difference was not observed between the 2 groups in the amount of red blood cell (0.47 vs 0.43 pack, P = 0.909) and platelet (0.60 vs 0.08 pack, P = 0.079) transfusion per day. CONCLUSION AND RELEVANCE: A weak correlation was observed between argatroban dose and the aPTT and ACT values. However, the agreement between aPTT and ACT was only 46.1% regarding the scope of target range. Further research is necessary to determine how to assess the optimal argatroban dose for patients administered argatroban while undergoing ECMO at the intensive care unit.


Asunto(s)
Arginina/análogos & derivados , Oxigenación por Membrana Extracorpórea , Hepatopatías , Sulfonamidas , Humanos , Tiempo de Tromboplastina Parcial , Heparina/efectos adversos , Anticoagulantes/efectos adversos , Oxigenación por Membrana Extracorpórea/efectos adversos , Ácidos Pipecólicos
18.
Crit Care ; 28(1): 57, 2024 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-38383506

RESUMEN

BACKGROUND: Extracorporeal cardiopulmonary resuscitation (ECPR) may reduce mortality and improve neurological outcomes in patients with cardiac arrest. We updated our existing meta-analysis and trial sequential analysis to further evaluate ECPR compared to conventional CPR (CCPR). METHODS: We searched three international databases from 1 January 2000 through 1 November 2023, for randomised controlled trials or propensity score matched studies (PSMs) comparing ECPR to CCPR in both out-of-hospital cardiac arrest (OHCA) and in-hospital cardiac arrest (IHCA). We conducted an updated random-effects meta-analysis, with the primary outcome being in-hospital mortality. Secondary outcomes included short- and long-term favourable neurological outcome and survival (30 days-1 year). We also conducted a trial sequential analysis to evaluate the required information size in the meta-analysis to detect a clinically relevant reduction in mortality. RESULTS: We included 13 studies with 14 pairwise comparisons (6336 ECPR and 7712 CCPR) in our updated meta-analysis. ECPR was associated with greater precision in reducing overall in-hospital mortality (OR 0.63, 95% CI 0.50-0.79, high certainty), to which the trial sequential analysis was concordant. The addition of recent studies revealed a newly significant decrease in mortality in OHCA (OR 0.62, 95% CI 0.45-0.84). Re-analysis of relevant secondary outcomes reaffirmed our initial findings of favourable short-term neurological outcomes and survival up to 30 days. Estimates for long-term neurological outcome and 90-day-1-year survival remained unchanged. CONCLUSIONS: We found that ECPR reduces in-hospital mortality, improves neurological outcome, and 30-day survival. We additionally found a newly significant benefit in OHCA, suggesting that ECPR may be considered in both IHCA and OHCA.


Asunto(s)
Reanimación Cardiopulmonar , Oxigenación por Membrana Extracorpórea , Paro Cardíaco Extrahospitalario , Humanos , Resultado del Tratamiento , Oxigenación por Membrana Extracorpórea/efectos adversos , Factores de Tiempo , Estudios Retrospectivos
19.
Crit Care ; 28(1): 158, 2024 05 10.
Artículo en Inglés | MEDLINE | ID: mdl-38730424

RESUMEN

BACKGROUND: An increasing number of patients requires extracorporeal membrane oxygenation (ECMO) for life support. This supportive modality is associated with nosocomial infections (NIs). This systematic review and meta-analysis aim to assess the incidence and risk factors of NIs in adult. METHODS: We searched PubMed, Scopus, Web of Science, and ProQuest databases up to 2022. The primary endpoint was incidence of NI. Secondary endpoints included time to infection, source of infection, ECMO duration, Intensive care and hospital length of stay (LOS), ECMO survival and overall survival. Incidence of NI was reported as pooled proportions and 95% confidence intervals (CIs), while dichotomous outcomes were presented as risk ratios (RR) as the effective index and 95% CIs using a random-effects model. RESULTS: Among the 4,733 adult patients who received ECMO support in the 30 included studies, 1,249 ECMO-related NIs per 1000 ECMO-days was observed. The pooled incidence of NIs across 18 studies involving 3424 patients was 26% (95% CI 14-38%).Ventilator-associated pneumonia (VAP) and bloodstream infections (BSI) were the most common NI sources. Infected patients had lower ECMO survival and overall survival rates compared to non-infected patients, with risk ratio values of 0.84 (95% CI 0.74-0.96, P = 0.01) and 0.80 (95% CI 0.71-0.90, P < 0.001), respectively. CONCLUSION: Results showed that 16% and 20% lower of ECMO survival and overall survival in patients with NI than patients without NI, respectively. However, NI increased the risk of in-hospital mortality by 37% in infected patients compared with non-infected patients. In addition, this study identified the significant positive correlation between ECMO duration and ECMO-related NI.


Asunto(s)
Infección Hospitalaria , Oxigenación por Membrana Extracorpórea , Humanos , Oxigenación por Membrana Extracorpórea/efectos adversos , Oxigenación por Membrana Extracorpórea/estadística & datos numéricos , Oxigenación por Membrana Extracorpórea/métodos , Infección Hospitalaria/epidemiología , Infección Hospitalaria/mortalidad , Incidencia , Factores de Riesgo , Adulto
20.
Crit Care ; 28(1): 54, 2024 02 20.
Artículo en Inglés | MEDLINE | ID: mdl-38374103

RESUMEN

BACKGROUND: Both critically ill patients with coronavirus disease 2019 (COVID-19) and patients receiving extracorporeal membrane oxygenation (ECMO) support exhibit a high incidence of healthcare-associated infections (HAI). However, data on incidence, microbiology, resistance patterns, and the impact of HAI on outcomes in patients receiving ECMO for severe COVID-19 remain limited. We aimed to report HAI incidence and microbiology in patients receiving ECMO for severe COVID-19 and to evaluate the impact of ECMO-associated infections (ECMO-AI) on in-hospital mortality. METHODS: For this study, we analyzed data from 701 patients included in the ECMOSARS registry which included COVID-19 patients supported by ECMO in France. RESULTS: Among 602 analyzed patients for whom HAI and hospital mortality data were available, 214 (36%) had ECMO-AI, resulting in an incidence rate of 27 ECMO-AI per 1000 ECMO days at risk. Of these, 154 patients had bloodstream infection (BSI) and 117 patients had ventilator-associated pneumonia (VAP). The responsible microorganisms were Enterobacteriaceae (34% for BSI and 48% for VAP), Enterococcus species (25% and 6%, respectively) and non-fermenting Gram-negative bacilli (13% and 20%, respectively). Fungal infections were also observed (10% for BSI and 3% for VAP), as were multidrug-resistant organisms (21% and 15%, respectively). Using a Cox multistate model, ECMO-AI were not found associated with hospital death (HR = 1.00 95% CI [0.79-1.26], p = 0.986). CONCLUSIONS: In a nationwide cohort of COVID-19 patients receiving ECMO support, we observed a high incidence of ECMO-AI. ECMO-AI were not found associated with hospital death. Trial registration number NCT04397588 (May 21, 2020).


Asunto(s)
COVID-19 , Infección Hospitalaria , Oxigenación por Membrana Extracorpórea , Neumonía Asociada al Ventilador , Sepsis , Humanos , COVID-19/epidemiología , COVID-19/terapia , COVID-19/complicaciones , Estudios de Cohortes , Oxigenación por Membrana Extracorpórea/efectos adversos , Oxigenación por Membrana Extracorpórea/métodos , Infección Hospitalaria/epidemiología , Neumonía Asociada al Ventilador/etiología , Sepsis/complicaciones , Atención a la Salud , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA