Pacing Clin Electrophysiol ; 47(5): 614-625, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38558218

RESUMEN

INTRODUCTION: The use of esophageal temperature monitoring (ETM) for the prevention of esophageal injury during atrial fibrillation (AF) ablation is often advocated. However, evidence supporting its use is scarce and controversial. We therefore aimed to review the evidence assessing the efficacy of ETM for the prevention of esophageal injury. METHODS: We performed a meta-analysis and systematic review of the available literature from inception to December 31, 2022. All studies comparing the use of ETM, versus no ETM, during radiofrequency (RF) AF ablation and which reported the incidence of endoscopically detected esophageal lesions (EDELs) were included. RESULTS: Eleven studies with a total of 1112 patients undergoing RF AF ablation were identified. Of those patients, 627 were assigned to ETM (56%). The overall incidence of EDELs was 9.8%. The use of ETM during AF ablation was associated with a non significant increase in the incidence of EDELs (12.3% with ETM, vs. 6.6 % without ETM, odds ratio, 1.44, 95%CI, 0.49, 4.22, p = .51, I2 = 72%). The use of ETM was associated with a significant increase in the energy delivered specifically on the posterior wall compared to patients without ETM (mean power difference: 5.13 Watts, 95% CI, 1.52, 8.74, p = .005). CONCLUSIONS: The use of ETM does not reduce the incidence of EDELs during RF AF ablation. The higher energy delivered on the posterior wall is likely attributable to a false sense of safety that may explain the lack of benefit of ETM. Further randomized controlled trials are needed to provide conclusive results.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Esófago , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/prevención & control , Esófago/lesiones , Temperatura Corporal , Monitoreo Intraoperatorio/métodos , Complicaciones Intraoperatorias/prevención & control
2.
Artículo en Inglés | MEDLINE | ID: mdl-37977548

RESUMEN

OBJECTIVE: To investigate the utility of simultaneous multi-catheter cryotherapy for the treatment of APs that were previously resistant to standard radiofrequency (RF) catheter ablation. BACKGROUND: Catheter ablation is established in the treatment of accessory pathways (AP), with high rates of permanent procedural success with a single attempt. However, there are still instances of acute procedural failure and AP recurrences with standard RF and cryotherapy methods. METHODS: Seven consecutive cases of pre-excitation syndromes with prior failed RF catheter ablation had the novel treatment. Cryotherapy was delivered using two 8 mm tip focal cryoablation catheters (Freezor® Max, Medtronic, Minneapolis, Minnesota, USA). RESULTS: Accessory pathway localisation was septal in 5 cases, left posterolateral in 1, right lateral in 1. In all cases, ablation of the AP was acutely successful with no procedural complications. Median procedure and fluoroscopy durations were 199 and 35 min, sequentially. Median Procedure duration fell significantly in the second half of series (174 min) compared to the first half (233 min, P = 0.05). One patient had evidence of a recurring AP conduction with pre-excitation at 5-week follow up. After a median follow up of 66.8+-6.5 months, 6 out of 7 patients remained asymptomatic and free of pre-excitation. CONCLUSION: Simultaneous multi-catheter cryotherapy is feasible, safe and can provide definitive cure of accessory pathways that were previously resistant to standard radiofrequency ablation. Further study is required in the assessment of this novel form of advanced cryotherapy to treat complex and resistant arrhythmias.

3.
Rev Med Suisse ; 20(856-7): 19-24, 2024 Jan 17.
Artículo en Francés | MEDLINE | ID: mdl-38231094

RESUMEN

The year 2023 has been extremely rich in new publications in the various subfields of cardiology. Furthermore, the European Society of Cardiology (ESC) has issued revised guidelines focused on the management of acute coronary syndrome (ACS) and endocarditis, as well as an update on the recommendations for the management of heart failure and cardiovascular prevention. The most significant updates according to the Cardiology Department of CHUV are summarized in this review article.


L'année 2023 a été extrêmement riche en nouvelles publications dans les différents sous-domaines de la cardiologie. De plus, la Société européenne de cardiologie (ESC) a formulé des directives révisées axées sur le management du syndrome coronarien aigu (SCA) et de l'endocardite ainsi qu'une mise à jour des recommandations sur la prise en charge de l'insuffisance cardiaque et la prévention cardiovasculaire. Les nouveautés les plus importantes selon l'équipe du Service de cardiologie du CHUV sont résumées dans cet article de synthèse.


Asunto(s)
Síndrome Coronario Agudo , Cardiología , Endocarditis , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/terapia
4.
Europace ; 25(10)2023 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-37695314

RESUMEN

AIMS: Stereotactic arrhythmia radioablation (STAR) has been recently introduced for the management of therapy-refractory ventricular tachycardia (VT). VT recurrences have been reported after STAR but the mechanisms remain largely unknown. We analysed recurrences in our patients after STAR. METHODS AND RESULTS: From 09.2017 to 01.2020, 20 patients (68 ± 8 y, LVEF 37 ± 15%) suffering from refractory VT were enrolled, 16/20 with a history of at least one electrical storm. Before STAR, an invasive electroanatomical mapping (Carto3) of the VT substrate was performed. A mean dose of 23 ± 2 Gy was delivered to the planning target volume (PTV). The median ablation volume was 26 mL (range 14-115) and involved the interventricular septum in 75% of patients. During the first 6 months after STAR, VT burden decreased by 92% (median value, from 108 to 10 VT/semester). After a median follow-up of 25 months, 12/20 (60%) developed a recurrence and underwent a redo ablation. VT recurrence was located in the proximity of the treated substrate in nine cases, remote from the PTV in three cases and involved a larger substrate over ≥3 LV segments in two cases. No recurrences occurred inside the PTV. Voltage measurements showed a significant decrease in both bipolar and unipolar signal amplitude after STAR. CONCLUSION: STAR is a new tool available for the treatment of VT, allowing for a significant reduction of VT burden. VT recurrences are common during follow-up, but no recurrences were observed inside the PTV. Local efficacy was supported by a significant decrease in both bipolar and unipolar signal amplitude.

5.
Rev Med Suisse ; 19(N° 809-10): 16-24, 2023 Jan 18.
Artículo en Francés | MEDLINE | ID: mdl-36660831

RESUMEN

The year of 2022 was marked by many novelties in the fields of interventional cardiology, heart failure, electrophysiology, cardiac imaging, and congenital heart disease. These advances will certainly change our daily practice, on top of improving the diagnosis and treatment of many heart conditions. In addition, the European Society of Cardiology has updated its guidelines on pulmonary hypertension, ventricular arrhythmias and sudden death, cardiovascular assessment of patients undergoing non-cardiac surgery. The members of the Cardiology division of Lausanne University Hospital (CHUV) here present the publications which they considered to be the most important of the past year.


L'année 2022 a été marquée par de nombreuses nouveautés dans les domaines de la cardiologie interventionnelle, de l'insuffisance cardiaque, de l'électrophysiologie, de l'imagerie cardiaque et des cardiopathies congénitales. Ces progrès vont certainement faire évoluer notre pratique quotidienne, en plus d'améliorer le diagnostic et le traitement de nombreuses cardiopathies. Par ailleurs, la Société européenne de cardiologie a mis à jour ses recommandations portant sur l'hypertension pulmonaire, les arythmies ventriculaires et la mort subite ainsi que le bilan cardiologique avant une chirurgie non cardiaque. Les membres du Service de cardiologie du CHUV vous présentent ici les travaux qui leur ont semblé être les plus importants de l'année écoulée.


Asunto(s)
Cardiología , Cardiopatías Congénitas , Insuficiencia Cardíaca , Humanos , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Cardiopatías Congénitas/diagnóstico
6.
J Cardiovasc Magn Reson ; 24(1): 9, 2022 01 13.
Artículo en Inglés | MEDLINE | ID: mdl-35022037

RESUMEN

BACKGROUND: The use of stress perfusion-cardiovascular magnetic resonance (CMR) imaging remains limited in patients with implantable devices. The primary goal of the study was to assess the safety, image quality, and the diagnostic value of stress perfusion-CMR in patients with MR-conditional transvenous permanent pacemakers (PPM) or implantable cardioverter-defibrillators (ICD). METHODS: Consecutive patients with a transvenous PPM or ICD referred for adenosine stress-CMR were enrolled in this single-center longitudinal study. The CMR protocol was performed using a 1.5 T system according to current guidelines while all devices were put in MR-mode. Quality of cine, late-gadolinium-enhancement (LGE), and stress perfusion sequences were assessed. An ischemia burden of ≥ 1.5 segments was considered significant. We assessed the safety, image quality and the occurrence of interference of the magnetic field with the implantable device. In case of ischemia, we also assessed the correlation with the presence of significant coronary lesions on coronary angiography. RESULTS: Among 3743 perfusion-CMR examinations, 66 patients had implantable devices (1.7%). Image quality proved diagnostic in 98% of cases. No device damage or malfunction was reported immediately and at 1 year. Fifty patients were continuously paced during CMR. Heart rate and systolic blood pressure remained unchanged during adenosine stress, while diastolic blood pressure decreased (p = 0.007). Six patients (9%) had an ischemia-positive stress CMR and significant coronary stenoses were confirmed by coronary angiography in all cases. CONCLUSION: Stress perfusion-CMR is safe, allows reliable ischemia detection, and provides good diagnostic value.


Asunto(s)
Desfibriladores Implantables , Imagen de Perfusión Miocárdica , Marcapaso Artificial , Adenosina , Estudios de Factibilidad , Humanos , Estudios Longitudinales , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Espectroscopía de Resonancia Magnética , Imagen de Perfusión , Valor Predictivo de las Pruebas
7.
Pacing Clin Electrophysiol ; 45(5): 658-665, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35417049

RESUMEN

BACKGROUND: With an increasing number of cardiac implantable electronic devices (CIEDs), there has been a paralleled increase in demand for transvenous lead extraction (TLE). Cardiac surgeons (CS) and cardiologists perform TLE; however, data comparing the two groups of operators is scarce. OBJECTIVE: We compared the outcomes of TLE performed by cardiologists and CS from six European lead extraction units. METHOD: Data was collected retrospectively of 2205 patients who had 3849 leads extracted (PROMET) between 2005 and 2018. Patient demographics and procedural outcomes were compared between the CS and cardiologist groups, using propensity score matching. A multivariate regression analysis was also performed for variables associated with 30-day mortality. RESULTS: CS performed the majority of extractions (59.8%), of leads with longer dwell times (90 [57-129 interquartile range (IQR)] vs. 62 [31-102 IQR] months, CS vs. cardiologists, p < .001) and with pre-dominantly non-infectious indications (57.4% vs. 50.2%, CS vs. cardiologists, p < .001). CS achieved a higher complete success per lead than the cardiologists (98.1% vs. 95.7%, respectively, p < .01), with a higher number of minor complications (5.51% vs. 2.1%, p < .01) and similar number of major complications (0.47% vs. 1.3%, p = .12). Thirty-day mortality was similarly low in the CS and cardiologist groups (1.76% vs. 0.94%, p = .21). Unmatched data multivariate analysis revealed infection indication (OR 6.12 [1.9-20.3], p < .01), procedure duration (OR 1.01 [1.01-1.02], p < .01) and CS operator (OR 2.67, [1.12-6.37], p = .027) were associated with 30-day mortality. CONCLUSION: TLE by CS was performed with similar safety and higher efficacy compared to cardiologists in high and medium-volume lead extraction centers.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Remoción de Dispositivos/métodos , Humanos , Prometazina , Estudios Retrospectivos , Resultado del Tratamiento
8.
Rev Med Suisse ; 18(783): 1048-1051, 2022 May 25.
Artículo en Francés | MEDLINE | ID: mdl-35612477

RESUMEN

Atrial fibrillation (AF) is the most common arrhythmia encountered in adults; it is associated with a significant morbidity and mortality. Obesity is a risk factor contributing to AF occurrence. Recently, interest has focused on epicardial adipose tissue (EAT), defined as a fatty deposit located between the epicardium and the visceral pericardium. Its characteristics are distinct from classic adipose deposits: it infiltrates the epicardial myocardium and secretes cytokines, which modulate cardiomyocyte electrophysiology and cardiac remodeling. Different studies show that EAT can be an independent risk factor for AF and that EAT thickness, as measured by CT or MRI, could predict the presence, severity and recurrence of AF.


La fibrillation auriculaire (FA) est l'arythmie la plus fréquemment rencontrée chez l'adulte ; elle est associée à une morbi-mortalité importante. L'obésité est un facteur de risque contribuant à sa survenue. Récemment, l'intérêt s'est porté sur le tissu adipeux épicardique (TAE), défini comme un dépôt adipeux situé entre l'épicarde et le péricarde viscéral. Ses caractéristiques sont distinctes des dépôts adipeux classiques : il infiltre le myocarde épicardique et sécrète des cytokines modulant l'électrophysiologie des cardiomyocytes et provoquant un remodelage fibro-adipeux cardiaque. Différentes études montrent que le TAE peut être un facteur de risque indépendant de survenue de FA. L'épaisseur du TAE mesurée par CT-scan ou par IRM pourrait être utilisée comme facteur prédictif de la présence, de la gravité et de la récidive de FA.


Asunto(s)
Fibrilación Atrial , Tejido Adiposo , Fibrilación Atrial/epidemiología , Humanos , Obesidad/complicaciones , Obesidad/epidemiología , Pericardio/diagnóstico por imagen , Factores de Riesgo
9.
Rev Med Suisse ; 18(767): 144-151, 2022 Feb 02.
Artículo en Francés | MEDLINE | ID: mdl-35107886

RESUMEN

Significant advances have been made in 2021 in the areas of interventional cardiology, heart failure, cardiac imaging, electrophysiology and congenital heart disease. In addition to improving the screening, diagnosis and management of many heart diseases, these advances will change our daily practice. Moreover, the European Society of Cardiology has updated its guidelines on heart failure, valve disease, cardiac pacing and cardiovascular disease prevention. As in previous years, members of the Cardiology division of Lausanne University Hospital (CHUV) came together to select and present to you the papers that they considered to be the most important of the past year.


De nombreux progrès ont été réalisés en 2021 dans les domaines de la cardiologie interventionnelle, de l'insuffisance cardiaque, de l'imagerie cardiaque, de l'électrophysiologie et des cardiopathies congénitales. En plus d'améliorer le dépistage, le diagnostic et la prise en charge de nombreuses cardiopathies, ces avancées vont faire évoluer notre pratique quotidienne. Par ailleurs, la Société européenne de cardiologie a mis à jour ses recommandations portant sur l'insuffisance cardiaque, les valvulopathies, la stimulation cardiaque et la prévention des maladies cardiovasculaires. Comme les années précédentes, les membres du Service de cardiologie du CHUV se sont réunis pour sélectionner et vous présenter les travaux qui leur ont semblé être les plus importants de l'année écoulée.


Asunto(s)
Cardiología , Cardiopatías Congénitas , Insuficiencia Cardíaca , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos
10.
Pacing Clin Electrophysiol ; 44(9): 1540-1548, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34235772

RESUMEN

BACKGROUND: Cardiac implantable electronic device (CIED) therapy contributes to an improvement in morbidity and mortality across all patient demographics. Patient age is a recognized risk factor for unfavorable outcomes in invasive procedures. This is the largest series of non-laser transvenous lead extraction (TLE) evaluating the association between patient age and procedure outcomes. METHODS: Data of 2205 (3849 leads) patients was collected retrospectively from six European TLE centers between January 2005-December 2018 in the PROMET study. Of these, 153 patients with 319 leads were excluded for incomplete data. A comparison of outcomes was performed between the age groups young [< 50 years], young intermediate [50-69 years], older intermediate [70-79 years], and octogenarian [≥80 years]. RESULTS: Infection was most common indication for TLE in the octogenarian cohort, less common in the younger population (60.1% vs. 33.2%, respectively, p < .01). High-voltage leads were extracted most frequently from young patients, less frequently from octogenarians (31.6% vs. 10%, p < .001), while the opposite was evident for pacemaker leads (p < .001). Rotational sheath use was equally prevalent across all patient groups (p = .79). Minor and major complications across all the age groups were statistically similar, as was procedural success; the 30-day mortality was most significant in the octogenarian and least in the young patients (4.9% vs. 0.4%, p = .005). Propensity matching multivariate analysis found systemic infection, lead dwell time, and patient age (p = .013, OR 1.064 [1.013-1.116]) increased risk of 30-day mortality. CONCLUSION: TLE is safe and effective across all age groups. 30-day mortality risk is significantly higher in the older patients.


Asunto(s)
Remoción de Dispositivos/métodos , Electrodos Implantados , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
11.
Rev Med Suisse ; 17(723): 172-180, 2021 Jan 27.
Artículo en Francés | MEDLINE | ID: mdl-33507655

RESUMEN

In 2020, new guidelines have been published by the European Society of Cardiology including those on non-ST-segment elevation acute coronary syndromes, atrial fibrillation and adult congenital heart disease. Regarding interventional cardiology, POPular TAVI opens the possibility of anti-platelet monotherapy after transcutaneous aortic valve replacement. EMPEROR-Reduced confirms the importance of SGLT2 inhibitors in the treatment of heart failure with reduced ejection fraction. Within the field of imaging, stress MRI has now become the first-line technique for the screening of coronary artery disease, demonstrating an excellent cost-benefit ratio. Finally, renin-angiotensin-aldosterone inhibitors do not appear to increase the risk of an infection by COVID-19.


L'année 2020 a été marquée par la publication de nouvelles guidelines de la Société européenne de cardiologie dont le syndrome coronarien aigu sans élévation du segment ST, la fibrillation auriculaire et les cardiopathies congénitales à l'âge adulte. En interventionnel, POPular TAVI permet d'envisager la monothérapie antithrombotique après remplacement de la valve aortique par voie transcutanée. EMPEROR-Reduced confirme l'importance des inhibiteurs du cotransporteur sodium-glucose de type 2 dans le traitement de l'insuffisance cardiaque à fraction d'éjection réduite. En imagerie, l'IRM de stress s'impose comme examen de choix pour le dépistage de la maladie coronarienne avec un rapport coût-bénéfice favorable. Enfin, les inhibiteurs du système rénine-angiotensine-aldostérone ne semblent pas augmenter le risque d'une infection au Covid-19.


Asunto(s)
COVID-19 , Cardiología , Cardiopatías Congénitas , Humanos , SARS-CoV-2
12.
Europace ; 22(7): 1103-1110, 2020 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-32447388

RESUMEN

AIMS: Several large studies have documented the outcome of transvenous lead extraction (TLE), focusing on laser and mechanical methods. To date there has been no large series addressing the results obtained with rotational lead extraction tools. This retrospective multicentre study was designed to investigate the outcomes of mechanical and rotational techniques. METHODS AND RESULTS: Data were collected on a total of 2205 patients (age 66.0 ± 15.7 years) with 3849 leads targeted for extraction in six European lead extraction centres. The commonest indication was infection (46%). The targeted leads included 2879 pacemaker leads (74.8%), 949 implantable cardioverter-defibrillator leads (24.6%), and 21 leads for which details were unknown; 46.6% of leads were passive fixation leads. The median lead dwell time was 74 months [interquartile range (IQR) 41-112]. Clinical success was obtained in 97.0% of procedures, and complete extraction was achieved for 96.5% of leads. Major complications occurred in 22/2205 procedures (1%), with a peri-operative or procedure-related mortality rate of 4/2205 (0.18%). Minor complications occurred in 3.1% of procedures. A total of 1552 leads (in 992 patients) with a median dwell time of 106 months (IQR 66-145) were extracted using the Evolution rotational TLE tool. In this subgroup, complete success was obtained for 95.2% of leads with a procedural mortality rate of 0.4%. CONCLUSION: Patient outcomes in the PROMET study compare favourably with other large TLE trials, underlining the capability of rotational TLE tools and techniques to match laser methods in efficacy and surpass them in safety.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
13.
Pacing Clin Electrophysiol ; 43(12): 1515-1520, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32860243

RESUMEN

BACKGROUND: Small series has shown that cardiac resynchronisation therapy (CRT) can be achieved in a majority of patients using exclusively cephalic venous access. We sought to determine whether this method is suitable for widespread use. METHODS: A group of 19 operators including 11 trainees in three pacing centres attempted to use cephalic access alone for all CRT device implants over a period of 8 years. The access route for each lead, the procedure outcome, duration, and complications were collected prospectively. Data were also collected for 105 consecutive CRT device implants performed by experienced operators not using the exclusively cephalic method. RESULTS: A new implantation of a CRT device using exclusively cephalic venous access was attempted in 1091 patients (73.6% male, aged 73 ± 12 years). Implantation was achieved using cephalic venous access alone in 801 cases (73.4%) and using a combination of cephalic and other access in a further 180 (16.5%). Cephalic access was used for 2468 of 3132 leads implanted (78.8%). Compared to a non-cephalic reference group, complications occurred less frequently (69/1091 vs 12/105; P = .0468), and there were no pneumothoraces with cephalic implants. Procedure and fluoroscopy duration were shorter (procedure duration 118 ± 45 vs 144 ± 39 minutes, P < .0001; fluoroscopy duration 15.7 ± 12.9 vs 22.8 ± 12.2 minutes, P < .0001). CONCLUSIONS: CRT devices can be implanted using cephalic access alone in a substantial majority of cases. This approach is safe and efficient.


Asunto(s)
Vena Axilar , Dispositivos de Terapia de Resincronización Cardíaca , Cateterismo Periférico/métodos , Competencia Clínica , Anciano , Terapia de Resincronización Cardíaca/métodos , Femenino , Humanos , Masculino , Estudios Prospectivos
14.
Rev Med Suisse ; 16(696): 1148-1152, 2020 Jun 03.
Artículo en Francés | MEDLINE | ID: mdl-32496703

RESUMEN

The gene SCN5A encodes the cardiac sodium channel which, through the conduction of Na+ current into the cell, generates the fast upstroke of the action potential of cardiomyocytes. Pathogenic variants of SCN5A have been causally associated to several hereditary cardiac diseases including, among others, Brugada syndrome, congenital long QT syndrome and sinus node dysfunction. Recently, overlap syndromes have been described that are characterized by the simultaneous expression of mixed clinical phenotypes among two or more hereditary cardiac diseases associated to the gene SCN5A (HCD-SCN5A). For this reason, it is time to rethink about HCD-SCN5A as different expressions of the same complex spectrum encompassing multiple clinical phenotypes with pronounced overlaps instead of as distinct clinical entities.


Le gène SCN5A code pour le canal sodique cardiaque qui est responsable de la pente de dépolarisation rapide du potentiel d'action. Plusieurs cardiopathies héréditaires (CH) ont été associées à des variants pathogènes du gène SCN5A incluant, entre autres, le syndrome de Brugada, le syndrome du QT long congénital et la dysfonction sinusale. Récemment, des syndromes de chevauchement ont été également décrits, s'exprimant, chez un même patient, par un phénotype clinique mixte comprenant une combinaison des manifestations rapportées ci-dessus. Dans ce contexte, nous devrions donc reconsidérer cliniquement les CH impliquant le gène SCN5A comme des expressions différentes d'un même éventail de phénotypes cliniques avec chevauchements marqués plutôt que comme des entités cliniques distinctes et isolées.


Asunto(s)
Síndrome de Brugada , Síndrome de QT Prolongado , Síndrome del Seno Enfermo , Síndrome de Brugada/genética , Humanos , Síndrome de QT Prolongado/genética , Mutación , Canal de Sodio Activado por Voltaje NAV1.5/genética , Fenotipo , Síndrome del Seno Enfermo/genética , Síndrome
15.
Rev Med Suisse ; 16(676-7): 16-22, 2020 Jan 15.
Artículo en Francés | MEDLINE | ID: mdl-31961076

RESUMEN

In 2019, the guidelines on the new entity « chronic coronary syndrome ¼ have been published. They influence importantly the work-up and treatment of patients with stable coronary artery disease. We will also report on publications showing the benefit of percutaneous aortic valve implantation (TAVI) in patients with aortic stenosis and low risk surgical risk. With regard to infectious endocarditis, we elucidate the importance of the vegetation's size for predicting mortality and the prognostic value of the positron emission tomography in predicting septic embolism. We highlight the spectacular results of the DAPA-HF study in patients with heart failure and review publications showing the important role of the detection of myocardial fibrosis and scar by cardiac MRI for risk stratification of sudden cardiac death.


L'année 2019 a été marquée par la publication de recommandations sur une nouvelle entité, appelée « syndrome coronarien chronique ¼, qui modifient de manière importante la prise en charge et le traitement des patients avec une maladie coronarienne stable. On relève plusieurs publications démontrant, chez les patients ayant une sténose aortique, et étant à bas risque chirurgical, le bénéfice d'un traitement percutané par rapport à un traitement chirurgical. La prise en charge de l'endocardite a été challengée par deux publications montrant que la taille de la végétation est un facteur de risque de mortalité et la valeur pronostique de la tomographie par émission de positons dans la survenue d'emboles septiques. Nous discutons les résultats spectaculaires de l'étude DAPA-HF dans le domaine d'insuffisance cardiaque et plusieurs études montrant l'intérêt de la recherche de cicatrice myocardique à l'IRM cardiaque dans la stratification du risque de mort subite.


Asunto(s)
Estenosis de la Válvula Aórtica , Cardiología , Implantación de Prótesis de Válvulas Cardíacas , Válvula Aórtica , Cateterismo Cardíaco , Cardiología/tendencias , Humanos , Factores de Riesgo , Resultado del Tratamiento
16.
Europace ; 20(12): 1997-2002, 2018 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-29868905

RESUMEN

Aims: Endocardial left ventricular (LV) pacing is a viable alternative in patients with failed coronary sinus (CS) lead implantation. However, long-term thrombo-embolic risk remains unknown. Much of the data have come from a small number of centres. We examined the safety and efficacy of endocardial LV pacing to determine the long-term thrombo-embolic risk. Methods and results: Registries from four UK centres were combined to include 68 patients with endocardial leads with a mean follow-up of 20 months. These were compared to a matched 1:2 control group with conventional CS leads. Medical records were reviewed, and patients contacted for follow-up. Ischaemic stroke occurred in four patients (6%) in the endocardial arm providing an annual event rate (AER) of 3.6% over a 20 month follow-up; compared to 9 patients (6.6%) amongst controls with an AER of 3.4% over a 23-month follow-up. Regression analyses showed a significant association between sub-therapeutic international normalized ratio and stroke (P = 0.0001) in the endocardial arm. There was no association between lead material and mode of delivery (transatrial/transventricular) and stroke. Mortality rate was 12 and 15 per 100 patient years in the endocardial and control arm respectively with end-stage heart failure being the commonest cause. Conclusion: Endocardial LV lead in heart failure patients has a good success rate at 1.6 year follow-up. However, it is associated with a thrombo-embolic risk (which is not different from conventional CS leads) attributable to sub-therapeutic anticoagulation. Randomized control trials and studies on non-vitamin K antagonist oral anticoagulants are required to ascertain the potential of widespread clinical application of this therapeutic modality.


Asunto(s)
Isquemia Encefálica/etiología , Estimulación Cardíaca Artificial/efectos adversos , Endocardio/fisiopatología , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/fisiopatología , Accidente Cerebrovascular/etiología , Tromboembolia/etiología , Función Ventricular Izquierda , Administración Oral , Anciano , Anciano de 80 o más Años , Anticoagulantes/administración & dosificación , Coagulación Sanguínea/efectos de los fármacos , Isquemia Encefálica/sangre , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/prevención & control , Estimulación Cardíaca Artificial/métodos , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Relación Normalizada Internacional , Masculino , Persona de Mediana Edad , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/sangre , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/prevención & control , Tromboembolia/sangre , Tromboembolia/diagnóstico , Tromboembolia/prevención & control , Factores de Tiempo , Resultado del Tratamiento , Reino Unido
17.
Europace ; 19(8): 1317-1321, 2017 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-27702870

RESUMEN

AIM: The Biosense Webster ThermoCool® SmartTouch® Surround Flow (STSF) catheter is a recently developed ablation catheter incorporating Surround Flow (SF) technology to ensure efficient cooling and force sensing to quantify tissue contact. In our unit, it superseded the ThermoCool® SF catheter from the time of its introduction in May 2015. METHODS AND RESULTS: Procedure-related data were collected prospectively for the first 100 ablation procedures performed in our department using the STSF catheter. From a database of 654 procedures performed in our unit using the SF catheter, we selected one to match each STSF procedure, matching for procedure type, operator experience, patient age, and gender. The groups were well matched for patient age, gender, and procedure type. Procedure duration was similar in both groups (mean 225.5 vs. 221.4 min, IQR 106.5 vs. 91.5, P = 0.55), but fluoroscopy duration was shorter in the STSF group (mean 25.8 vs. 30.0, IQR 19.6 vs. 18.5, P = 0.03). No complication occurred in the STSF group. Complications occurred in two cases in the SF group (one pericardial effusion requiring drainage and one need for permanent pacing). Complete procedural success was achieved in 98 cases in the STSF group and 94 cases in the SF group (P = 0.15). The composite endpoint of procedure failure or acute complication was less common in the STSF group (2 vs. 8, P = 0.05). CONCLUSION: The STSF catheter is safe and effective in treating a range of arrhythmias. Compared with the SF catheter, it shows a trend towards improved safety-efficacy balance.


Asunto(s)
Arritmias Cardíacas/cirugía , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Ablación por Catéter/instrumentación , Irrigación Terapéutica/instrumentación , Transductores de Presión , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Cateterismo Cardíaco/efectos adversos , Ablación por Catéter/efectos adversos , Bases de Datos Factuales , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Irrigación Terapéutica/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
18.
Europace ; 19(9): 1521-1526, 2017 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-28340095

RESUMEN

AIMS: Non-laser-based methods are safe in lead extraction but in the past have been less effective than laser methods. In the past decade, new equipment has been introduced including the Evolution® Mechanical Dilator Sheath and the Evolution® RL. We sought to determine the impact of new equipment on outcome in mechanical lead extraction. METHODS AND RESULTS: We considered 288 consecutive patients (age 66 ± 18 years) who underwent transvenous lead extraction (TLE) of 522 leads in the decade to the end of 2014. Three groups were identified: Group 1 (pre-Evolution® period, 76 patients, 133 leads), Group 2 (original Evolution® period, 115 patients, 221 leads), and Group 3 (Evolution® RL period, 97 patients, 168 leads). The age of leads was significantly greater in Groups 2 and 3 (6.2 ± 4.4 and 6.1 ± 5.4 years vs.4.7 ± 4.5, P < 0.05) as was the proportion of implantable cardioverter defibrillator leads (27.2 and 28.9 vs. 14.3%, P < 0.05). The groups were similar in the number of leads extracted per patient. Despite the increasing complexity of the systems extracted, complete extraction was achieved in a progressively greater proportion of leads (88.0% in Group 1, 95.5% in Group 2, and 97.6% in Group 3, P < 0.05), and procedure duration was similar. The proportion of leads for which femoral access was required was greater in Group 3 (11%, 18/164) compared with Group 2 (3%, 7/211), P = 0.006. The only major complications were a post-procedure subacute tamponade in Group 1 and an oesophageal injury related to transoesophageal echocardiography in Group 3. CONCLUSION: With current equipment, mechanical extraction provides a good combination of efficacy and safety.


Asunto(s)
Cateterismo Cardíaco/métodos , Desfibriladores Implantables , Remoción de Dispositivos/métodos , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/tendencias , Catéteres Cardíacos , Remoción de Dispositivos/efectos adversos , Remoción de Dispositivos/instrumentación , Remoción de Dispositivos/tendencias , Difusión de Innovaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Diseño de Prótesis , Falla de Prótesis , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
19.
Europace ; 18(3): 428-35, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26683599

RESUMEN

AIMS: To assess the usefulness of intrathoracic impedance monitoring (IIM) alerts in guiding empirical treatment of chronic heart failure (CHF) patients to prevent heart failure (HF) hospitalizations and unplanned HF care. METHODS AND RESULTS: Chronic heart failure patients with OptiVol or CorVue capable implantable cardioverter-defibrillators were randomized to either the active group (IIM alarm turned on and diuretic dose increased by 50% for 1 week in the event of alarm sounding) or the control group (IIM alarm turned off). The primary endpoint was the number of HF hospitalizations per patient at 1 year. The NYHA class, 6MWT, B-type natriuretic peptide (BNP), and MLWHF questionnaire score were collected at baseline and follow-up. Eighty patients were included and 71 reached 1-year follow-up. There were 1.7 ± 1.5 alerts in the active group and 1.1 ± 1.0 in the control group, P = 0.07. In the active group, 61% of alerts led to a diuretic dose increase. There was a total of 11 HF hospitalizations in the active group vs. 6 in the control group without significant differences in the number of episodes per patient (0.3 ± 0.9 vs. 0.2 ± 0.4, P = 0.95). There were no unplanned HF visits in the active group vs. 0.1 ± 0.3 per patient in the control group, P = 0.08. The total MLWHF scores were significantly increased at the final follow-up in the control group, whereas a trend towards reduction was observed in the active group. CONCLUSION: In this study, an empirical HF treatment guided by IIM alerts did not reduce emergency treatment of HF. However, it seems to have a positive impact on quality of life. CLINICAL TRIAL REGISTRATIONURL: http://www.clinicaltrials.gov. Unique identifier: NCT01320007.


Asunto(s)
Cardiografía de Impedancia , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Insuficiencia Cardíaca/terapia , Pulmón/fisiopatología , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Enfermedad Crónica , Diuréticos/administración & dosificación , Impedancia Eléctrica , Servicio de Urgencia en Hospital , Prueba de Esfuerzo , Tolerancia al Ejercicio , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Hospitalización , Humanos , Londres , Masculino , Persona de Mediana Edad , Péptido Natriurético Encefálico/sangre , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Calidad de Vida , Encuestas y Cuestionarios , Factores de Tiempo , Resultado del Tratamiento
20.
Curr Cardiol Rep ; 17(9): 631, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26266757

RESUMEN

Catheter ablation is superior to antiarrhythmic drugs in maintaining sinus rhythm for patients with atrial fibrillation (AF). Pulmonary vein (PV) isolation is the cornerstone of any AF ablation procedure. Conventionally, this is achieved by performing point by point lesions using radiofrequency (RF) energy. However, this is technically challenging, time consuming and is associated with a number of complications. Long-term durability of PV isolation is also a concern. To address these issues, 'one-shot' energy delivery systems and alternative energy sources have been developed. The cryoballoon system has emerged as the most commonly used alternative to point by point RF technology. In this paper, we compare the technology, biophysics and clinical data of cryoballoon to conventional RF ablation for AF. The safety and efficacy of cryoballoon compared to RF ablation is critically reviewed. We conclude by looking at future applications of this technology.


Asunto(s)
Antiarrítmicos/uso terapéutico , Fibrilación Atrial/terapia , Ablación por Catéter , Criocirugía , Venas Pulmonares/patología , Fibrilación Atrial/fisiopatología , Humanos , Venas Pulmonares/inervación , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS