Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Medicina (Kaunas) ; 60(4)2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38674168

RESUMEN

The application of cardiac magnetic resonance (CMR) imaging in clinical practice has grown due to technological advancements and expanded clinical indications, highlighting its superior capabilities when compared to echocardiography for the assessment of myocardial tissue. Similarly, the utilization of implantable cardiac electronic devices (CIEDs) has significantly increased in cardiac arrhythmia management, and the requirements of CMR examinations in patients with CIEDs has become more common. However, this type of exam often presents challenges due to safety concerns and image artifacts. Until a few years ago, the presence of CIED was considered an absolute contraindication to CMR. To address these challenges, various technical improvements in CIED technology, like the reduction of the ferromagnetic components, and in CMR examinations, such as the introduction of new sequences, have been developed. Moreover, a rigorous protocol involving multidisciplinary collaboration is recommended for safe CMR examinations in patients with CIEDs, emphasizing risk assessment, careful monitoring during CMR, and post-scan device evaluation. Alternative methods to CMR, such as computed tomography coronary angiography with tissue characterization techniques like dual-energy and photon-counting, offer alternative potential solutions, although their diagnostic accuracy and availability do limit their use. Despite technological advancements, close collaboration and specialized staff training remain crucial for obtaining safe diagnostic CMR images in patients with CIEDs, thus justifying the presence of specialized centers that are equipped to handle these type of exams.


Asunto(s)
Desfibriladores Implantables , Imagen por Resonancia Magnética , Marcapaso Artificial , Humanos , Desfibriladores Implantables/normas , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/instrumentación , Arritmias Cardíacas/diagnóstico por imagen
2.
Medicina (Kaunas) ; 60(4)2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38674259

RESUMEN

Background and Objectives: Cardiac magnetic resonance (CMR) imaging has become an essential instrument in the study of cardiomyopathies; it has recently been integrated into the diagnostic workflow for cardiac amyloidosis (CA) with remarkable results. An additional emerging role is the stratification of the arrhythmogenic risk by scar analysis and the possibility of merging these data with electro-anatomical maps. This is made possible by using a software (ADAS 3D, Galgo Medical, Barcelona, Spain) able to provide 3D heart models by detecting fibrosis along the whole thickness of the myocardial walls. Little is known regarding the applications of this software in the wide spectrum of cardiomyopathies and the potential benefits have yet to be discovered. In this study, we tried to apply the ADAS 3D in the context of CA. Materials and Methods: This study was a retrospectively analysis of consecutive CMR imaging of patients affected by CA that were treated in our center (Marche University Hospital). Wherever possible, the data were processed with the ADAS 3D software and analyzed for a correlation between the morphometric parameters and follow-up events. The outcome was a composite of all-cause mortality, unplanned cardiovascular hospitalizations, sustained ventricular arrhythmias (VAs), permanent reduction in left ventricular ejection fraction, and pacemaker implantation. The secondary outcomes were the need for a pacemaker implantation and sustained VAs. Results: A total of 14 patients were deemed eligible for the software analysis: 8 patients with wild type transthyretin CA, 5 with light chain CA, and 1 with transthyretin hereditary CA. The vast majority of imaging features was not related to the composite outcome, but atrial wall thickening displayed a significant association with both the primary (p = 0.003) and the secondary outcome of pacemaker implantation (p = 0.003). The software was able to differentiate between core zones and border zones of scars, with the latter being the most extensively represented in all patients. Interestingly, in a huge percentage of CMR images, the software identified the highest degree of core zone fibrosis among the epicardial layers and, in those patients, we found a higher incidence of the primary outcome, without reaching statistical significance (p = 0.18). Channels were found in the scar zones in a substantial percentage of patients without a clear correlation with follow-up events. Conclusions: CMR imaging plays a pivotal role in cardiovascular diagnostics. Our analysis shows the feasibility and applicability of such instrument for all types of CA. We could not only differentiate between different layers of scars, but we were also able to identify the presence of fibrosis channels among the different scar zones. None of the data derived from the ADAS 3D software seemed to be related to cardiac events in the follow-up, but this might be imputable to the restricted number of patients enrolled in the study.


Asunto(s)
Amiloidosis , Cardiomiopatías , Cicatriz , Imagen por Resonancia Magnética , Humanos , Masculino , Proyectos Piloto , Femenino , Cardiomiopatías/diagnóstico por imagen , Amiloidosis/diagnóstico por imagen , Amiloidosis/complicaciones , Anciano , Cicatriz/diagnóstico por imagen , Estudios Retrospectivos , Persona de Mediana Edad , Imagen por Resonancia Magnética/métodos , Programas Informáticos
3.
Medicina (Kaunas) ; 59(9)2023 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-37763769

RESUMEN

Background and Objectives: Recently published articles reported an association between psoriasis and interstitial lung diseases (ILDs). The aim of this study is to evaluate the differences in ILD computed tomography (CT) patterns between smoker and never smoker plaque psoriasis (PP) patients under topical treatment without psoriatic arthritis (PA), inflammatory bowel disease (IBD) or connective tissue diseases (CTDs). Matherials and Methods: Two radiologists evaluated chest CT examinations of 65 patients (33 smokers, 32 never smokers) with PP. Results: Usual interstitial pneumonia (UIP) pattern was diagnosed in 36 patients, nonspecific interstitial pneumonia pattern in 19, hypersensitivity pneumonitis in 7 and pleuropulmonary fibroelastosis (PPFE) in 3 patients. UIP pattern showed a statistically significant higher frequency in smoker patients (p = 0.0351). Respiratory symptoms were reported in 80% of patients. Conclusions: ILDs seems to represent a new comorbidity associated with psoriasis. Moreover, a statistically significant association between smokers and UIP pattern in PP patients is found. Respiratory symptoms should be evaluated in PP patients, in collaboration with a radiologist and a pneumologist. However, further studies are required to better understand the epidemiology of ILDs in PP patients.


Asunto(s)
Fibrosis Pulmonar Idiopática , Enfermedades Pulmonares Intersticiales , Psoriasis , Humanos , Estudios Retrospectivos , Enfermedades Pulmonares Intersticiales/complicaciones , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Enfermedades Pulmonares Intersticiales/epidemiología , Psoriasis/complicaciones , Psoriasis/diagnóstico por imagen , Psoriasis/epidemiología , Tomografía Computarizada por Rayos X
4.
Medicina (Kaunas) ; 60(1)2023 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-38256331

RESUMEN

A cardiac lesion detected at ultrasonography might turn out to be a normal structure, a benign tumor or rarely a malignancy, and lesion characterization is very important to appropriately manage the lesion itself. The exact relationship of the mass with coronary arteries and the knowledge of possible concomitant coronary artery disease are necessary preoperative information. Moreover, the increasingly performed coronary CT angiography to evaluate non-invasively coronary artery disease leads to a rising number of incidental findings. Therefore, CT and MRI are frequently performed imaging modalities when echocardiography is deemed insufficient to evaluate a lesion. A brief comprehensive overview about diagnostic radiological imaging and the clinical background of cardiac masses and pseudomasses is reported.


Asunto(s)
Enfermedad de la Arteria Coronaria , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Angiografía por Tomografía Computarizada , Angiografía Coronaria
5.
Emerg Radiol ; 29(4): 645-653, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35606630

RESUMEN

OBJECTIVE: To identify a cut-off value of epicardial adipose tissue (EAT) volume quantified by CT associated with a worse clinical outcome in patients with SARS-CoV-2 pneumonia. MATERIALS AND METHODS: In this retrospective study, sixty patients with a diagnosis of laboratory-confirmed COVID-19 pneumonia and a chest CT exam on admission were enrolled. Based on a total severity score (range 0-20), patients were divided into two groups: ordinary group (total severity score < 7) and severe/critical group (total severity score > 7). Clinical results and EAT volume were compared between the two groups. RESULTS: The severe/critical patients, compared to the ordinary ones, were older (66.83 ± 11.72 vs 58.57 ± 16.86 years; p = 0.031), had higher body mass index (27.77 ± 2.11 vs 25.07 ± 2.80 kg/m2; p < 0.001) and higher prevalence of comorbidities. EAT volume was higher in severe/critical group, compared with the ordinary group (151.40 ± 66.22 cm3 vs 92.35 ± 44.46 cm3, p < 0.001). In severe/critical group, 19 (73%) patients were admitted in intensive care unit (ICU), compared with 6 (20%) patients in the ordinary group (p < 0.001). The area under the ROC curve (AUC) is equal to 0.781 (p < 0.001) (95% CI: 0.662-0.900). The cut-off found, in correspondence with the highest value of the Youden Index, is 97 cm3: the sensitivity is equal to 83.3%, while the specificity is equal to 70% for predicting a worse outcome. The risk (odds ratio) of belonging to the severe/critical group in this population due to EAT ≥ 97 cm3 is 11.667 (95% CI: 3.384-40.220; p < 0.001). CONCLUSION: An EAT volume of 97 cm3 has good sensitivity and specificity to predict a greater extent of pulmonary involvement and therefore a worse clinical outcome in patients with SARS-CoV-2 pneumonia.


Asunto(s)
COVID-19 , Neumonía , Tejido Adiposo/diagnóstico por imagen , Humanos , Pronóstico , Estudios Retrospectivos , SARS-CoV-2 , Tomografía Computarizada por Rayos X/métodos
6.
J Clin Ultrasound ; 50(6): 817-825, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35730639

RESUMEN

The ultra-high frequency ultrasound (UHFUS) is characterized by the use of probes between 30 and 100 MHz. This technology has recently been introduced in clinical practice and represents an opportunity for the diagnosis of numerous pathologies. The high spatial resolution of UHFUS, up to 30 µ in pixel size, allows to study the pathological modifications and to guide microsurgery treatments in anatomical body structures not evaluable by conventional HFUS. The aim of this work is to provide a review of the literature on the current clinical applications of UHFUS and to discuss its added role in different clinical settings.


Asunto(s)
Ultrasonografía , Humanos , Ultrasonografía/métodos
7.
Medicina (Kaunas) ; 57(3)2021 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-33802881

RESUMEN

Myocardial inflammation is an important cause of cardiovascular morbidity and sudden cardiac death in athletes. The relationship between sports practice and myocardial inflammation is complex, and recent data from studies concerning cardiac magnetic resonance imaging and endomyocardial biopsy have substantially added to our understanding of the challenges encountered in the comprehensive care of athletes with myocarditis or inflammatory cardiomyopathy (ICM). In this review, we provide an overview of the current knowledge on the epidemiology, pathophysiology, diagnosis, and treatment of myocarditis, ICM, and myopericarditis/perimyocarditis in athletes, with a special emphasis on arrhythmias, patient-tailored therapies, and sports eligibility issues.


Asunto(s)
Miocarditis , Deportes , Atletas , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Humanos , Inflamación , Miocarditis/diagnóstico
8.
Medicina (Kaunas) ; 57(5)2021 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-34066957

RESUMEN

Athlete's heart (AH) is the result of morphological and functional cardiac modifications due to long-lasting athletic training. Athletes can develop very marked structural myocardial changes, which may simulate or cover unknown cardiomyopathies. The differential diagnosis between AH and cardiomyopathy is necessary to prevent the risk of catastrophic events, such as sudden cardiac death, but it can be a challenging task. The improvement of the imaging modalities and the introduction of the new technologies in cardiac magnetic resonance (CMR) and cardiac computed tomography (CCT) can allow overcoming this challenge. Therefore, the radiologist, specialized in cardiac imaging, could have a pivotal role in the differential diagnosis between structural adaptative changes observed in the AH and pathological anomalies of cardiomyopathies. In this review, we summarize the main CMR and CCT techniques to evaluate the cardiac morphology, function, and tissue characterization, and we analyze the imaging features of the AH and the key differences with the main cardiomyopathies.


Asunto(s)
Cardiomegalia Inducida por el Ejercicio , Cardiomiopatía Hipertrófica , Atletas , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Muerte Súbita Cardíaca , Diagnóstico Diferencial , Corazón/diagnóstico por imagen , Humanos , Radiólogos
9.
Medicina (Kaunas) ; 57(4)2021 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-33805943

RESUMEN

The prediction and prevention of sudden cardiac death is the philosopher's stone of clinical cardiac electrophysiology. Sports can act as triggers of fatal arrhythmias and therefore it is essential to promptly frame the athlete at risk and to carefully evaluate the suitability for both competitive and recreational sports activity. A history of syncope or palpitations, the presence of premature ventricular complexes or more complex arrhythmias, a reduced left ventricular systolic function, or the presence of known or familiar heart disease should prompt a thorough evaluation with second level examinations. In this regard, cardiac magnetic resonance and electrophysiological study play important roles in the diagnostic work-up. The role of genetics is increasing both in cardiomyopathies and in channelopathies, and a careful evaluation must be focused on genotype positive/phenotype negative subjects. In addition to being a trigger for fatal arrhythmias in certain cardiomyopathies, sports also play a role in the progression of the disease itself, especially in the case arrhythmogenic right ventricular cardiomyopathy. In this paper, we review the latest European guidelines on sport cardiology in patients with cardiovascular diseases, focusing on arrhythmic risk stratification and the management of cardiomyopathies and channelopathies.


Asunto(s)
Cardiología , Cardiomiopatías , Enfermedades Cardiovasculares , Canalopatías , Deportes , Cardiomiopatías/complicaciones , Canalopatías/complicaciones , Canalopatías/genética , Humanos
10.
Radiol Med ; 125(11): 1024-1039, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32930945

RESUMEN

Computed tomography coronary angiography (CTCA) has become a cornerstone in the diagnostic process of the heart disease. Although the cardiac imaging with interventional procedures is responsible for approximately 40% of the cumulative effective dose in medical imaging, a relevant radiation dose reduction over the last decade was obtained, with the beginning of the sub-mSv era in CTCA. The main technical basis to obtain a radiation dose reduction in CTCA is the use of a low tube voltage, the adoption of a prospective electrocardiogram-triggering spiral protocol and the application of the tube current modulation with the iterative reconstruction technique. Nevertheless, CTCA examinations are characterized by a wide range of radiation doses between different radiology departments. Moreover, the dose exposure in CTCA is extremely important because the benefit-risk calculus in comparison with other modalities also depends on it. Finally, because anatomical evaluation not adequately predicts the hemodynamic relevance of coronary stenosis, a low radiation dose in routine CTCA would allow the greatest use of the myocardial CT perfusion, fractional flow reserve-CT, dual-energy CT and artificial intelligence, to shift focus from morphological assessment to a comprehensive morphological and functional evaluation of the stenosis. Therefore, the aim of this work is to summarize the correct use of the technical basis in order that CTCA becomes an established examination for assessment of the coronary artery disease with low radiation dose.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Dosis de Radiación , Exposición a la Radiación/prevención & control , Factores de Edad , Algoritmos , Inteligencia Artificial , Índice de Masa Corporal , Angiografía por Tomografía Computarizada/instrumentación , Circulación Coronaria , Femenino , Reserva del Flujo Fraccional Miocárdico , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Medición de Riesgo , Factores Sexuales , Factores de Tiempo
11.
Radiol Med ; 125(12): 1249-1259, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32367320

RESUMEN

BACKGROUND: As one of the most frequent risk factors for cardiovascular disease, type 2 diabetes mellitus (T2DM) is one of the largest causes of death. However, an acute cardiac presentation is not uncommon in diabetic patients, and the current investigative approach remains often inadequate. The aim of our study was to retrospectively stratify the risk of asymptomatic T2DM patients using low-dose 640-slice coronary computed tomography angiography (CCTA). MATERIALS AND METHODS: CCTA examinations of 62 patients (mean age, 65 years) with previous diagnosis of type 2 diabetes and without cardiac symptoms were analyzed. Image acquisition was performed using a 640-slice CT. Per-patient, per-vessel and per-plaque analyses were performed. Stratification risk was evaluated according to the ESC guidelines. The patients were followed up after 2.21 ± 0.56 years from CCTA examination. RESULTS: Coronary artery disease (CAD) was found in 58 patients (93.55%) presenting 290 plaques. Analysis of all samples showed severe-to-occlusive atherosclerosis in 24 patients (38.7% of cases). However, over the degree of stenosis, 23 patients were evaluated at high risk considering the extension of CAD. Good agreement was shown by the correlation of CAD extension/risk estimation and MACE incidence, according to a Kaplan-Meier survival analysis (p value = 0.001), with a 7.25-fold increased risk (HR 7.25 CI 2.13-24.7; p value = 0.002). CONCLUSION: Our study confirms the high capability of CCTA to properly stratify the CV risk of asymptomatic T2DM patients. Its use could be recommended if we consider how current investigative strategies to correctly assess these patients often seem inadequate.


Asunto(s)
Enfermedades Asintomáticas , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Diabetes Mellitus Tipo 2/complicaciones , Placa Aterosclerótica/diagnóstico por imagen , Anciano , Angiografía por Tomografía Computarizada , Enfermedad de la Arteria Coronaria/etiología , Estenosis Coronaria/diagnóstico por imagen , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector/métodos , Placa Aterosclerótica/etiología , Dosis de Radiación , Estudios Retrospectivos , Medición de Riesgo
12.
Radiol Med ; 125(2): 117-127, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31686317

RESUMEN

PURPOSE: To compare measured radiation dose (MD), estimated radiation dose (ED) and image quality in coronary computed tomography between turbo-flash (TFP) and retrospective protocol (RP) and correlate MD with size-specific dose estimates (SSDE). MATERIALS AND METHODS: In this prospective study, we selected 68 patients (mean age, 59.2 ± 9.7 years) undergoing 192 × 2 dual-source CT (SOMATOM Force, Siemens) to rule out coronary artery disease. Thirty-one underwent TFP and 37 RP. To evaluate in vivo MD, thermoluminescent dosimeters were placed, superficially, at thyroid and heart level, left breast areola and left hemi-thorax. MD in each site, and ED parameters, such as volume CT dose index (CTDIvol), SSDE, dose length product (DLP), effective dose (E), were compared between two protocols with a t test. Image quality was compared between two protocols. Inter-observer agreement was evaluated with a kappa coefficient (k). In each protocol, MD was correlated with SSDE using a Pearson coefficient (r). RESULTS: Comparing TFP and RP, MD at thyroid (1.43 vs. 2.58 mGy; p = 0.0408), heart (3.58 vs. 28.72 mGy; p < 0.0001), left breast areola (3.00 vs. 24.21 mGy; p < 0.0001) and left hemi-thorax (2.68 vs. 24.03 mGy; p < 0.0001), CTDIvol, SSDE, DLP and E were significantly lower. Differences in image quality were not statistically significant. Inter-observer agreement was good (k = 0.796) in TFP and very good (k = 0.817) in RP. MD and SSDE excellently correlated with TFP (r = 0.9298, p < 0.0001) and RP (r = 0.9753, p < 0.0001). CONCLUSIONS: With TFP, MD, CTDIvol, SSDE, DLP and E were significantly lower, than with RP. Image quality was similar between two protocols. MD correlated excellently with SSDE in each protocol.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Dosis de Radiación , Medios de Contraste , Femenino , Humanos , Yopamidol , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Interpretación de Imagen Radiográfica Asistida por Computador , Dosimetría Termoluminiscente
13.
Radiol Med ; 124(8): 753-761, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31011995

RESUMEN

PURPOSE: To compare radiation exposure associated with daily practice cardiovascular (CV) examinations performed on two different multidetector computed tomography (MDCT) scanners, a conventional 64-MDCT and a third-generation dual-source (DS) MDCT. MATERIALS AND METHODS: In this retrospective study, 1458 patients who underwent CV examinations between January 2017 and August 2018 were enrolled. A single-source 64-MDCT (Lightspeed VCT, GE) scan was performed in 705 patients from January to August 2017 (207 coronary examinations and 498 vascular examinations) and 753 patients underwent third-generation 192 × 2-DSCT (Somatom FORCE, Siemens) scan from January to August 2018 (302 coronary examinations and 451 vascular examinations). Volume CT dose index (CTDIvol), dose length product (DLP), effective dose (ED), tube voltage (TV) and exposure time (ET), pitch factor (PF) were registered for each patient. Student's t test was used to compare mean values between each corresponding group of MDCT and DSCT. RESULTS: In coronary examinations with DSCT, CTDIvol was 24.4% lower (23.1 mGy vs 30.6 mGy, p < 0.0001) and DLP and ED reductions were 35.6% than with MDCT (465.0 mGy * cm vs 732.3 mGy * cm and 6.5 mSv and 10.3 mSv; vs p < 0.0001). Concerning scan parameters, kVp and ET reductions were 12.7% and 69.4%, respectively (p < 0.0001); PF increase was 73.8% (p < 0.0001). In all vascular studies, DSCT, compared with MDCT, permitted to reduce CTDIvol from 43.5 to 70.6%; DLP and ED reductions were from 50.3 to 73.1%; kVp and ET decreases were from 10.7 to 32.5% and from 26.3 to 68.7%. PF increase was from 16.7 to 58.1% (all differences with p < 0.0001). CONCLUSIONS: In daily practice, CV examinations CTDI, DLP, ED, ET and TV were lower and PF was higher with 192 × 2-DSCT compared to 64-MDCT.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Tomografía Computarizada Multidetector/métodos , Exposición a la Radiación , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Angiografía por Tomografía Computarizada/efectos adversos , Angiografía por Tomografía Computarizada/instrumentación , Angiografía Coronaria/efectos adversos , Angiografía Coronaria/instrumentación , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Seguridad de Equipos , Humanos , Tomografía Computarizada Multidetector/efectos adversos , Tomografía Computarizada Multidetector/instrumentación , Dosis de Radiación , Imagen Radiográfica por Emisión de Doble Fotón/efectos adversos , Imagen Radiográfica por Emisión de Doble Fotón/instrumentación , Estudios Retrospectivos , Factores de Tiempo
14.
Radiol Med ; 124(7): 581-587, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30806920

RESUMEN

PURPOSE: To evaluate a possible correlation between apparent diffusion coefficient (ADC) value and tumor-infiltrating lymphocytes (TILs) level in breast cancer (BC). A second objective was to assess whether there were other histopathologic features that could affect mean ADC value. METHODS: In this 4-year retrospective study were included 125 patients who underwent radical or modified mastectomy for monofocal BC. All subjects had performed preoperative MRI with the same 1.5-T machine and protocol, which consisted of STIR, DWI and DCE sequences. Based on TIL score, BCs were stratified into two groups: absent-low TIL (≤ 10%) and medium-high TIL (> 10%). The t test was used to correlate mean ADC value with TIL groups. Receiver operating characteristic curve and Youden index were used in order to identify ADC value threshold to distinguish the two TIL groups. RESULTS: BC patients with absent-low TIL level and medium-high TIL one were, respectively, 66 (52.8%) and 59 (47.2%). Mean ADC value was 1.05 ± 0.19 * 10-3 mm2 s-1. Absent-low TIL group showed a lower mean ADC value than medium-high TIL one (0.96 ± 0.18 * 10-3 mm2 s-1 vs 1.14 ± 0.16 * 10-3 mm2 s-1; p < 0.0001). ADC value threshold in order to distinguish the two TIL groups with maximum sensitivity (67.8%) and specificity (80.3%) was 1.03 * 10-3 mm2 s-1. ADC value was shown to be significantly related to TILs level (p < 0.0001) and cancer histotype (p = 0.0006), with a lower mean ADC value correlated to absent-low TIL level and ductal histotype. CONCLUSION: BCs with absent-low TIL showed a statistically significant lower mean ADC value than those with medium-high TIL. ADC value threshold in order to distinguish these two groups was 1.03 * 10-3 mm2 s-1.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Imagen de Difusión por Resonancia Magnética/métodos , Linfocitos Infiltrantes de Tumor/patología , Adulto , Anciano , Biomarcadores de Tumor/análisis , Neoplasias de la Mama/cirugía , Medios de Contraste , Femenino , Humanos , Mastectomía/métodos , Meglumina , Persona de Mediana Edad , Clasificación del Tumor , Compuestos Organometálicos , Estudios Retrospectivos
15.
Radiol Med ; 124(12): 1238-1252, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31630332

RESUMEN

Cardiovascular computer tomography (CT) in pediatric congenital heart disease (CHD) patients is often challenging. This might be due to limited patient cooperation, the high heart rate, the complexity and variety of diseases and the need for radiation dose minimization. The recent developments in CT technology with the introduction of the third-generation dual-source (DS) dual-energy (DE) CT scanners well suited to respond to these challenges. DSCT is characterized by high-pitch, long anatomic coverage and a more flexible electrocardiogram-synchronized scan. DE provides additional clinical information about vascular structures, myocardial and lung perfusion and allows artifacts reduction. These advances have increased clinical indications and modified CT protocol for pediatric CHD patients. In our hospital, DSCT with DE technology has rapidly become an important imaging technique for both pre- and postoperative management of pediatric patients with CHDs. The aim of this article is to describe the state-of-the-art in DSCT protocol with DE technology in pediatric CHD patients, providing some case examples of our experience over an 18-month period.


Asunto(s)
Cardiopatías Congénitas/diagnóstico por imagen , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Artefactos , Niño , Preescolar , Medios de Contraste/administración & dosificación , Filtración/instrumentación , Frecuencia Cardíaca , Humanos , Lactante , Recién Nacido , Movimientos de los Órganos , Dosis de Radiación , Imagen Radiográfica por Emisión de Doble Fotón/instrumentación , Respiración , Tomografía Computarizada por Rayos X/instrumentación
16.
Radiol Med ; 124(3): 184-190, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30478814

RESUMEN

PURPOSE: To compare radiation dose and image quality of lower extremity computed tomography angiography (CTA) between cranio-caudal acquisition with single-source CT (SSCT) and flash caudo-cranial acquisition with dual-source CT (DSCT). MATERIALS AND METHODS: In this prospective study, 60 patients were randomly assigned to Group A (control) or Group B (experimental) to undergo lower extremity CTA for peripheral obliterative arterial disease. Group A received protocol 1 (P1) with SSCT cranio-caudal acquisition. Group B received protocol (P2) with DSCT flash caudo-cranial acquisition. Intravascular attenuation (IVA), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image noise were compared. Two radiologists assessed the image quality. Computed tomography volume dose index (CTDIvol) and dose-length product (DLP) were also compared. RESULTS: IVA with P2 was higher than with P1 (586.8 ± 140.3 vs. 496.1 ± 129.3 HU, p = 0.011), as was SNR (33.0 ± 11.3 vs. 27.4 ± 12.3; p = 0.042), CNR (30.1 ± 13.3 vs. 24.2 ± 10.3; p = 0.029) and image quality score of small arteries below the knee (3.8 ± 0.2 vs. 3.1 ± 0.2; p = 0.001). Radiation dose was significantly lower in P2 than in P1 with CTDIvol reduction of 40.9% (1.3 ± 0.1 vs. 2.2 ± 0.3 mGy; p = 0.006) and DLP reduction of 42.8% (148.7 ± 21.9 vs 260.2 ± 59.1 mGy * cm; p = 0.018). CONCLUSION: Lower extremity CTA with DSCT flash caudo-cranial acquisition allows lower radiation dose with higher IVA, SNR, CNR and better image quality for small arteries below the knee than SSCT cranio-caudal acquisition.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Extremidad Inferior/irrigación sanguínea , Extremidad Inferior/diagnóstico por imagen , Enfermedad Arterial Periférica/diagnóstico por imagen , Dosis de Radiación , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Protocolos Clínicos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Relación Señal-Ruido , Método Simple Ciego , Adulto Joven
18.
Radiol Case Rep ; 18(8): 2645-2648, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37287722

RESUMEN

Rhabdomyoma is the most common primary cardiac tumor in pediatric patients. A strong association exists between cardiac rhabdomyomas and tuberous sclerosis (TS), an autosomal dominant disease, characterized by diffuse lesions in the nervous system, such as cortical-subcortical tubers and subependymal nodules. In TS, cardiac rhabdomyomas typically are diagnosed in childhood, but they could be detected in the neonatal period with echocardiography and magnetic resonance imaging and may precede cerebral lesions. Therefore, the precocious detection of cardiac rhabdomyomas in pediatric patients can suggest the diagnosis of TS and the early detection of cerebral lesions, improving the management of the related symptoms. We reported the cases of 4 pediatric patients, in which the detection of cardiac rhabdomyomas lead to the early discovery of cerebral lesions and the diagnosis of the TS.

19.
Br J Radiol ; 96(1148): 20221026, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37183830

RESUMEN

OBJECTIVE: To investigate the feasibility of an ultra-low radiation dose and contrast volume protocol using third-generation dual-source (DS) CT for transcatheter aortic valve implantation (TAVI) planning with coronary artery disease (CAD) assessment, coronary artery calcium score (CACS) and aortic valve calcium score (AVCS) quantification and to evaluate their relationship with TAVI outcome. METHODS: In this retrospective study were selected 203 patients (131 males, 79.4 ± 5.4 years) underwent to TAVI and at 30- and 90-day follow-up. All patients had performed a third-generation 2 × 192-slices DSCT. The CT protocol included a non-contrast and a contrast high-pitch aortic acquisition for TAVI planning and CAD assessment. Semi-qualitative and quantitative image analysis were performed; the performance in CAD assessment was compared with ICA; the relationship between AVCS and CACS and paravalvular aortic regurgitation (PAR) and major cardiovascular events (MACEs) were evaluated. Mean radiation dose were calculated. Non-parametric tests were used. RESULTS: Semi-qualitative image analysis was good. Contrast enhancement >500 Hounsfield unit (HU) and contrast-to-noise ratio <20 were obtained in all segments. The diagnostic accuracy in CAD was 89.0%. AVCS was significantly higher in patients with 30-day severe PAR. AVCS and CACS were higher in patients with 90-day MACE complications, respectively, 1904.5 ± 621.3 HU (p < 0.0001) and 769.2 ± 365.5 HU (p < 0.0230). Mean radiation dose was 2.8 ± 0.3 mSv. CONCLUSION: A TAVI planning ultra-low radiation dose and contrast volume protocol using third-generation DSCT provides highly diagnostic images with CAD assessment, AVCS and CACS quantification and these latter were related with TAVI outcomes. ADVANCES IN KNOWLEDGE: The proposed protocol using third-generation 2 × 192-slices DSCT allows with an ultra-low radiation dose and contrast volume the TAVI planning and the coronary artery assessment.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estudios Retrospectivos , Calcio , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Tomografía Computarizada de Haz Cónico , Dosis de Radiación
20.
J Cardiol Cases ; 28(6): 229-232, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38126055

RESUMEN

Myocardial bridging (MB) is a congenital anomaly characterized by the intramyocardial coronary course that can cause coronary compression during systole leading to myocardial ischemia, often with the concomitant presence of endothelial dysfunction.Improvements in computed tomography (CT) technology have increased the burden of MB detection during coronary-CT (cCT) but their anatomical and functional assessment is often challenging. A stress-rest myocardial perfusion imaging (MPI) by single-photon emission CT (SPECT) is usually required to decide the correct patient management. However, SPECT has long acquisition protocols, poor spatial resolution, and significant radiation doses for the patient. The recent advances in CT scan technology have allowed the evaluation of stress-rest MPI, representing a promising alternative to SPECT.In this paper, we report six cases of MBs assessed with cCT examination and further evaluated with a stress-rest dynamic-CT MPI and SPECT. A reversible perfusion defect in the left anterior descending (LAD) territory segments potentially due to MB was detected in two of six patients, and they were referred for heart team evaluation.In conclusion, cCT and stress-rest dynamic-CT MPI allowed to detect MBs, evaluate their functional significance, and decide the patients' management in a "one-stop shop" examination. Learning objective: Improvements in computed tomography (CT) technology have increased the burden of myocardial bridging (MB) detection during coronary-CT but their anatomical and functional assessment is often challenging.A stress-rest myocardial perfusion imaging (MPI) by single-photon emission CT (SPECT) is then usually required to decide the correct patient management.Recent advances in CT scan technology have allowed the evaluation of stress-rest MPI, that represent a promising alternative to SPECT.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA