Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Sci Rep ; 13(1): 10472, 2023 06 28.
Artículo en Inglés | MEDLINE | ID: mdl-37380707

RESUMEN

Minimally invasive endovascular interventions have become an important tool for the treatment of cardiovascular diseases such as ischemic heart disease, peripheral artery disease, and stroke. X-ray fluoroscopy and digital subtraction angiography are used to precisely guide these procedures, but they are associated with radiation exposure for patients and clinical staff. Magnetic Particle Imaging (MPI) is an emerging imaging technology using time-varying magnetic fields combined with magnetic nanoparticle tracers for fast and highly sensitive imaging. In recent years, basic experiments have shown that MPI has great potential for cardiovascular applications. However, commercially available MPI scanners were too large and expensive and had a small field of view (FOV) designed for rodents, which limited further translational research. The first human-sized MPI scanner designed specifically for brain imaging showed promising results but had limitations in gradient strength, acquisition time and portability. Here, we present a portable interventional MPI (iMPI) system dedicated for real-time endovascular interventions free of ionizing radiation. It uses a novel field generator approach with a very large FOV and an application-oriented open design enabling hybrid approaches with conventional X-ray-based angiography. The feasibility of a real-time iMPI-guided percutaneous transluminal angioplasty (PTA) is shown in a realistic dynamic human-sized leg model.


Asunto(s)
Angioplastia , Enfermedad Arterial Periférica , Humanos , Angiografía de Substracción Digital , Encéfalo , Campos Magnéticos
2.
Eur J Radiol ; 163: 110834, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37080059

RESUMEN

PURPOSE: To assess the role of current imaging-based resectability criteria and the degree of radiological downsizing in locally advanced pancreatic adenocarcinoma (LAPC) after multiagent induction chemotherapy (ICT) in multicentre, open-label, randomized phase 2 trial. METHOD: LAPC patients were prospectively treated with multiagent ICT followed by surgical exploration within the NEOLAP trial. All patients underwent CT scan at baseline and after ICT to assess resectability status according to national comprehensive cancer network guidelines (NCCN) criteria and response evaluation criteria in solid tumors (RECIST) at the local study center and retrospectively in a central review. Imaging results were compared in terms of local and central staging, downsizing and pathological resection status. RESULTS: 83 patients were evaluable for central review of baseline and restaging imaging results. Downstaging by central review was rarely seen after multiagent ICT (7.7%), whereas tumor downsizing was documented frequently (any downsizing 90.4%, downsizing to partial response (PR) according to RECIST: 26.5%). Patients with any downsizing showed no significant different R0 resection rate (37.3%) as patients that fulfilled the criteria of PR (40.9%). The sensitivity of any downsizing for predicting R0 resection was 97% with a negative predictive value (NPV) of 0.88. ROC-analysis revealed that tumor downsizing was a predictor of R0 resection (AUC 0.647, p = 0.028) with a best cut-off value of 22.5% downsizing yielding a sensitivity of 65% and a specificity of 61%. CONCLUSIONS: Imaging-based tumor downsizing and not downstaging can guide the selection of patients with a realistic chance of R0-resection in LAPC after multi-agent ICT.


Asunto(s)
Adenocarcinoma , Neoplasias Pancreáticas , Humanos , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/tratamiento farmacológico , Neoplasias Pancreáticas/cirugía , Estudios Prospectivos , Estudios Retrospectivos , Adenocarcinoma/diagnóstico por imagen , Adenocarcinoma/tratamiento farmacológico , Adenocarcinoma/cirugía , Terapia Neoadyuvante , Tomografía Computarizada por Rayos X/métodos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Estadificación de Neoplasias
3.
Radiography (Lond) ; 29(1): 19-27, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36209641

RESUMEN

INTRODUCTION: The aim of this study was to evaluate the influence of a noise optimized virtual monoenergetic reconstruction algorithm (VMI+) on the image quality and assessability of dual energy (DE) computed tomography angiography (CTA) of the lower extremity runoff. METHODS: A total of 118 lower extremity runoff CTA performed on a 3rd generation DE-CT scanner in 109 patients (54 females; 75.6 ± 9.5 years) were included in this retrospective study. Axial image stacks were reconstructed with a standard 120 kV setting and VMI+ of different keV levels. Objective image quality criteria (contrast attenuation, signal-to-noise [SNR] and contrast-to-noise ratio [CNR]) were measured. Two radiologists evaluated subjective image quality regarding intraluminal attenuation and image noise using a 5-point Likert scale. Diagnostic accuracy for significant stenosis (>75%) and vessel occlusion was assessed for 120 kV and 50 keV VMI+ images rated by two radiologists. In all patients, a digital subtraction angiography (DSA) rated by on board-certified radiologist served as the standard of reference. RESULTS: Intraluminal attenuation was highest in 40/50 keV VMI+ while SNR were similar to 120 kV images. In subjective assessment, intraluminal contrast of 50 keV images was deemed superior compared to 120 kV despite higher image noise. Sensitivity, specificity, and accuracy for detection of a vessel occlusion were similar in 50 keV VMI+ compared to 120 kV (70%/92%/84%; 70%/91%/83%; p < 0.001) but 13 of 118 (11%) lower leg runoffs were only assessable with 50 keV VMI+. CONCLUSION: VMI+ reconstructions improve assessability of DE-CTA by increased luminal attenuation with consistent image noise, also allowing the evaluation of lower leg arterial segments inassessable with standard reconstructions. IMPLICATIONS FOR PRACTICE: Providing higher intraluminal attenuation and similar image noise compared with conventional reconstructions, 50 keV VMI+ may be appropriate for routine evaluation of DE-CTA.


Asunto(s)
Angiografía por Tomografía Computarizada , Imagen Radiográfica por Emisión de Doble Fotón , Femenino , Humanos , Angiografía por Tomografía Computarizada/métodos , Pierna/diagnóstico por imagen , Relación Señal-Ruido , Estudios Retrospectivos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Extremidad Inferior/diagnóstico por imagen
4.
Radiography (Lond) ; 29(1): 44-49, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36274316

RESUMEN

INTRODUCTION: This study investigated the image quality of a new quantum iterative reconstruction algorithm (QIR) for high resolution photon-counting CT of the hip. METHODS: Using a first-generation photon-counting CT scanner, five cadaveric specimens were examined with ultra-high-resolution protocols matched for radiation dose. Images were post-processed with a sharp convolution kernel and five different strength levels of iterative reconstruction (QIR 0 - QIR 4). Subjective image quality was rated independently by three radiologists on a five-point scale. Intraclass correlation coefficients (ICC) were computed for assessing interrater agreement. Objective image quality was evaluated by means of contrast-to-noise-ratios (CNR) in bone and muscle tissue. RESULTS: For osseous tissue, subjective image quality was rated best for QIR 2 reformatting (median 5 [interquartile range 5-5]). Contrarily, for soft tissue, QIR 4 received the highest ratings among compared strength levels (3 [3-4]). Both ICCbone (0.805; 95% confidence interval 0.711-0.877; p < 0.001) and ICCmuscle (0.885; 0.824-0.929; p < 0.001) suggested good interrater agreement. CNR in bone and muscle tissue increased with ascending strength levels of iterative reconstruction with the highest results recorded for QIR 4 (CNRbone 29.43 ± 2.61; CNRmuscle 8.09 ± 0.77) and lowest results without QIR (CNRbone 3.90 ± 0.29; CNRmuscle 1.07 ± 0.07) (all p < 0.001). CONCLUSION: Reconstructing photon-counting CT data with an intermediate QIR strength level appears optimal for assessment of osseous tissue, whereas soft tissue analysis benefitted from applying the highest strength level available. IMPLICATIONS FOR PRACTICE: Quantum iterative reconstruction technique can enhance image quality by significantly reducing noise and improving CNR in ultra-high resolution CT imaging of the hip.


Asunto(s)
Huesos , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Algoritmos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
5.
Radiography (Lond) ; 28(3): 690-696, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35728278

RESUMEN

INTRODUCTION: The purpose of this study was to determine the potential for metal artefact reduction in low-dose multidetector CT as these pose a frequent challenge in clinical routine. Investigations focused on whether spectral shaping via tin prefiltration, virtual monoenergetic imaging or virtual blend imaging (VBI) offers superior image quality in comparison with conventional CT imaging. METHODS: Using a third-generation dual-source CT scanner, two cadaveric specimens with different metal implants (dental, cervical spine, hip, knee) were examined with acquisition protocols matched for radiation dose with regards to tube voltage and current. In order to allow for precise comparison, and due to the relatively short scan lengths, automatic tube current modulation was disabled. Specifically, the following scan protocals were examined: conventional CT protocols (100/120 kVp), tin prefiltration (Sn 100/Sn 150 kVp), VBI and virtual monoenergetic imaging (VME 100/120/150 keV). Mean attenuation and image noise were measured in hyperdense and hypodense artefacts, in artefact-impaired and artefact-free soft tissue. Subjective image quality was rated independently by three radiologists. RESULTS: Objectively, Sn 150 kVp allowed for the best reduction of hyperdense streak artefacts (p < 0.001), while VME 150 keV and Sn 150 kVp protocols facilitated equally good reduction of hypodense artefacts (p = 0.173). Artefact-impaired soft tissue attenuation was lowest in Sn 150 kVp protocols (p ≤ 0.011), whereas all VME showed significantly less image noise compared to conventional or tin-filtered protocols (p ≤ 0.001). Subjective assessment favoured Sn 150 kVp regarding hyperdense streak artefacts and delineation of cortical bone (p ≤ 0.005). The intraclass correlation coefficient was 0.776 (95% confidence interval: 0.712-0.831; p < 0.001) indicating good interrater reliability. CONCLUSION: In the presence of metal implants in our cadaveric study, tin prefiltration with 150 kVp offers superior artefact reduction for low-dose CT imaging of osseous tissue compared with virtual monoenergetic images of dual-energy datasets. The delineation of cortical boundaries seems to benefit particularly from spectral shaping. IMPLICATIONS FOR PRACTICE: Low-dose CT imaging of osseous tissue in combination with tin prefiltration allows for superior metal artefact reduction when compared to virtual monoenergetic images of dual-energy datasets. Employing this technique ought to be considered in daily routine when metal implants are present within the scan volume as findings suggest it allows for radiation dose reduction and facilitates diagnosis relevant to further treatment.


Asunto(s)
Estaño , Tomografía Computarizada por Rayos X , Artefactos , Cadáver , Humanos , Metales , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos
6.
Radiography (Lond) ; 28(2): 433-439, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34716089

RESUMEN

INTRODUCTION: While tin prefiltration is established in various CT applications, its value in extremity cone-beam CT relative to optimized spectra has not been thoroughly assessed thus far. This study aims to investigate the effect of tin filters in extremity cone-beam CT with a twin-robotic X-ray system. METHODS: Wrist, elbow and ankle joints of two cadaveric specimens were examined in a laboratory setup with different combinations of prefiltration (copper, tin), tube voltage and current-time product. Image quality was assessed subjectively by five radiologists with Fleiss' kappa being computed to measure interrater agreement. To provide a semiquantitative criterion for image quality, contrast-to-noise ratios (CNR) were compared for standardized regions of interest. Volume CT dose indices were calculated for a 16 cm polymethylmethacrylate phantom. RESULTS: Radiation dose ranged from 17.4 mGy in the clinical standard protocol without tin filter to as low as 0.7 mGy with tin prefiltration. Image quality ratings and CNR for tin-filtered scans with 100 kV were lower than for 80 kV studies with copper prefiltration despite higher dose (11.2 and 5.6 vs. 4.5 mGy; p < 0.001). No difference was ascertained between 100 kV scans with tin filtration and 60 kV copper-filtered scans with 75% dose reduction (subjective: p = 0.101; CNR: p = 0.706). Fleiss' kappa of 0.597 (95% confidence interval 0.567-0.626; p < 0.001) indicated moderate interrater agreement. CONCLUSION: Considerable dose reduction is feasible with tin prefiltration, however, the twin-robotic X-ray system's low-dose potential for extremity 3D imaging is maximized with a dedicated low-kilovolt scan protocol in situations without extensive beam-hardening artifacts. IMPLICATIONS FOR PRACTICE: Low-kilovolt imaging with copper prefiltration provides a superior trade-off between dose reduction and image quality compared to tin-filtered cone-beam CT scan protocols with higher tube voltage.


Asunto(s)
Procedimientos Quirúrgicos Robotizados , Estaño , Tomografía Computarizada de Haz Cónico/métodos , Cobre , Extremidades , Humanos , Dosis de Radiación , Rayos X
7.
Phys Med ; 88: 65-70, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34192659

RESUMEN

PURPOSE: Magnetic Particle Imaging (MPI) is a new, background- and radiation-free tomographic imaging method that enables near real-time imaging of superparamagnetic iron-oxide nanoparticles (SPIONs) with high temporal and spatial resolution. This phantom study aims to investigate the potential of MPI for visualization of the stent lumen in intracranial flow diverters (FD). METHODS: Nitinol FD of different dimensions (outer diameter: 3.5 mm, 4.0 mm, 5.5 mm; total length: 22-40 mm) were scanned in vascular phantoms in a custom-built MPI scanner (in-plane resolution: ~ 2 mm, field of view: 65 mm length, 29 mm diameter). Phantoms were filled with diluted (1:50) SPION tracer agent Ferucarbotran (10 µmol (Fe)/ml; NaCL). Each phantom was measured in 32 different projections (overall acquisition time per image: 3200 ms, 5averages). After image reconstruction from raw data, two radiologists assessed image quality using a 5-point Likert scale. The signal intensity profile was measured using a semi-automatic evaluation tool. RESULTS: MPI visualized the lumen of all FD without relevant differences between the stented vessel phantom and the reference phantom. At 3.5 mm image quality was slightly inferior to the larger diameters. The FD themselves neither generated an MPI signal nor did they lead to relevant imaging artifacts. Ratings of both radiologists showed no significant difference, interrater reliability was good (ICC 0.84). A quantitative evaluation of the signal intensity profile did not reveal any significant differences (p > 0.05) either. CONCLUSION: MPI visualizes the lumen of nitinol FD stents in vessel phantoms without relevant stent-induced artifacts.


Asunto(s)
Artefactos , Tomografía , Fenómenos Magnéticos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Stents
8.
Eur J Radiol ; 139: 109653, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33838429

RESUMEN

PURPOSE: This study aimed to assess the feasibility of Self-gated Non-Contrast-Enhanced Functional Lung (SENCEFUL) MRI for detection of pulmonary perfusion deficits in patients with cystic fibrosis. METHODS: Twenty patients with cystic fibrosis and 20 matched healthy controls underwent SENCEFUL-MRI at 1.5 T with reconstruction of perfusion and perfusion phase maps (i.e. comparable to pulse wave delays). Four blinded readers rated both types of maps separately followed by simultaneous assessment thereof. Perfusion phase data was plotted in histograms and a Peak-to-Offset ratio was calculated for comparison to subjective scoring and correlation (Spearman) to lung function parameters. Sensitivity, specificity and positive and negative predictive values were calculated for subjective scoring and Peak-to-Offset ratios. Intraclass correlation (ICC) was used to assess the interrater agreement. RESULTS: Readers attributed pathological ratings 2.2-3.5 times more frequently to the CF-group. The sensitivity with regard to a correct assignment to CF was similar between ratings (perfusion only vs. perfusions phase only vs. simultaneous assessment: 0.54-0.56), while specificity increased from 0.75 to 0.85 for simultaneous assessment. ICC was 0.77-0.84 for subjective scoring. ROC-analysis of Peak-to-Offset ratios on a mean per-subject basis revealed a sensitivity of 0.75 and specificity of 0.85 (PPV 0.83, NPV 0.77). Functional pulmonary parameters indicative of bronchial obstruction and Peak-to-Offset ratios showed positive correlation (FEV1: 0.77; FEF75: 0.76). CONCLUSIONS: SENCEFUL-MRI bears the potential for monitoring CF including disease-associated patterns of altered pulmonary perfusion. The proposed Peak-to-Offset ratio derived from pulmonary perfusion phase measurements could represent an objective future marker for perfusion impairment.


Asunto(s)
Obstrucción de las Vías Aéreas , Fibrosis Quística , Fibrosis Quística/diagnóstico por imagen , Humanos , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética , Perfusión
11.
Magn Reson Imaging ; 71: 125-131, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32534067

RESUMEN

PURPOSE: The gradient system transfer function (GSTF) can be used to describe the dynamic gradient system and applied for trajectory correction in non-Cartesian MRI. This study compares the field camera and the phantom-based methods to measure the GSTF and implements a compensation for the difference in measurement dwell time. METHODS: The self-term GSTFs of a MR system were determined with two approaches: 1) using a dynamic field camera and 2) using a spherical phantom-based measurement with standard MR hardware. The phantom-based GSTF was convolved with a box function to compensate for the dwell time dependence of the measurement. The field camera and phantom-based GSTFs were used for trajectory prediction during retrospective image reconstruction of 3D wave-CAIPI phantom images. RESULTS: Differences in the GSTF magnitude response were observed between the two measurement methods. For the wave-CAIPI sequence, this led to deviations in the GSTF predicted trajectories of 4% compared to measured trajectories, and residual distortions in the reconstructed phantom images generated with the phantom-based GSTF. Following dwell-time compensation, deviations in the GSTF magnitudes, GSTF-predicted trajectories, and resulting image artifacts were eliminated (< 0.5% deviation in trajectories). CONCLUSION: With dwell time compensation, both the field camera and the phantom-based GSTF self-terms show negligible deviations and lead to strong artifact reduction when they are used for trajectory correction in image reconstruction.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Fantasmas de Imagen , Algoritmos , Artefactos , Humanos , Imagenología Tridimensional , Estudios Retrospectivos
12.
Magn Reson Med ; 81(4): 2464-2473, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30393947

RESUMEN

PURPOSE: This study aimed to develop a 3D MRI technique to assess lung ventilation in free-breathing and without the administration of contrast agent. METHODS: A 3D-UTE sequence with a koosh ball trajectory was developed for a 3 Tesla scanner. An oversampled k-space was acquired, and the direct current signal from the k-space center was used as a navigator to sort the acquired data into 8 individual breathing phases. Gradient delays were corrected, and iterative SENSE was used to reconstruct the individual timeframes. Subsequently, the signal changes caused by motion were eliminated using a 3D image registration technique, and ventilation-weighted maps were created by analyzing the signal changes in the lung tissue. Six healthy volunteers and 1 patient with lung cancer were scanned with the new 3D-UTE and the standard 2D technique. Image quality and quantitative ventilation values were compared between both methods. RESULTS: UTE-based self-gated noncontrast-enhanced functional lung (SENCEFUL) MRI provided a time-resolved reconstruction of the breathing motion, with a 49% increase of the SNR. Ventilation quantification for healthy subjects was in statistical agreement with 2D-SENCEFUL and the literature, with a mean value of 0.11 ± 0.08 mL/mL for the whole lung. UTE-SENCEFUL was able to visualize and quantify ventilation deficits in a patient with lung tumor that were not properly depicted by 2D-SENCEFUL. CONCLUSION: UTE-SENCEFUL represents a robust MRI method to assess both morphological and functional information of the lungs in 3D. When compared to the 2D approach, 3D-UTE offered ventilation maps with higher resolution, improved SNR, and reduced ventilation artifacts.


Asunto(s)
Medios de Contraste/química , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Respiración , Adulto , Algoritmos , Artefactos , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Femenino , Voluntarios Sanos , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Movimiento (Física) , Perfusión , Técnicas de Imagen Sincronizada Respiratorias/métodos , Relación Señal-Ruido , Adulto Joven
13.
IEEE Trans Med Imaging ; 37(1): 61-67, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28644801

RESUMEN

Magnetic particle imaging (MPI) is a promising new tomographic imaging method to detect the spatial distribution of superparamagnetic iron-oxide nanoparticles (SPIOs). The aim of this paper was to investigate the potential of MPI to quantify artificial stenoses in vessel phantoms. Custom-made stenosis phantoms (length 40 mm; inner diameter 8 mm) with different degrees of stenosis (0%, 25%, 50%, 75%, and 100%) were scanned in a custom-built MPI scanner (in-plane resolution: ~1-1.5 mm and field of view: 65 29 29 mm3). Phantoms were filled with diluted Feru-carbotran [SPIO agent, 5 mmol (Fe)/l]. Each measurement (overall acquisition time: 20 ms per image, 400 averages) was repeated ten times to assess reproducibility. The MPI signal was used for semi-automatic stenosis quantification. Two stenosis evaluation approaches were compared based on the signal intensity profile alongside the stenosis phantoms. Using a novel multi-step image evaluation approach, MPI allowed for accurate quantification of different stenosis grades. While low grade stenoses were slightly over-estimated, high grade stenoses were slightly underestimated. In particular, the 0%, 25%, and 50% stenosis phantoms revealed a 6.2% ± 0.8, 25.7% ± 1.0, and 48.0% ± 1.5 stenosis, respectively. The higher grade 75% stenosis phantom revealed a 73.3% ± 2.8 and the 100% stenosis phantom a 95.8%± 1.9 stenosis. MPI accurately visualized and quantified different stenosis grades in vessel phantoms with high reproducibility demonstrating its great potential for fast and radiation-free preclinical cardiovascular imaging.


Asunto(s)
Nanopartículas de Magnetita/química , Imagen Molecular/métodos , Fantasmas de Imagen , Tomografía/métodos , Animales , Estenosis Carotídea/diagnóstico por imagen , Humanos , Modelos Cardiovasculares
14.
BMC Cardiovasc Disord ; 16(1): 205, 2016 10 28.
Artículo en Inglés | MEDLINE | ID: mdl-27793097

RESUMEN

BACKGROUND: Fabry disease is characterized by a progressive deposition of sphingolipids in different organ systems, whereby cardiac involvement leads to death. We hypothesize that lysosomal storage of sphingolipids in the heart as occurring in Fabry disease does not reflect in higher cardiac lipid concentrations detectable by 1H magnetic resonance spectroscopy (MRS) at 3 Tesla. METHODS: Myocardial lipid content was quantified in vivo by 1H-MRS in 30 patients (12 male, 18 female; 18 patients treated with enzyme replacement therapy) with genetically proven Fabry disease and in 30 healthy controls. The study protocol combined 1H-MRS with cardiac cine imaging and LGE MRI in a single examination. RESULTS: Myocardial lipid content was not significantly elevated in Fabry disease (p = 0.225). Left ventricular (LV) mass was significantly higher in patients suffering from Fabry disease compared to controls (p = 0.019). Comparison of patients without signs of myocardial fibrosis in MRI (LGE negative; n = 12) to patients with signs of fibrosis (LGE positive; n = 18) revealed similar myocardial lipid content in both groups (p > 0.05), while the latter showed a trend towards elevated LV mass (p = 0.076). CONCLUSIONS: This study demonstrates the potential of lipid metabolic investigation embedded in a comprehensive examination of cardiac morphology and function in Fabry disease. There was no evidence that lysosomal storage of sphingolipids influences cardiac lipid content as measured by 1H-MRS. Finally, the authors share the opinion that a comprehensive cardiac examination including three subsections (LGE; 1H-MRS; T1 mapping), could hold the highest potential for the final assessment of early and late myocardial changes in Fabry disease.


Asunto(s)
Cardiomiopatías/metabolismo , Enfermedad de Fabry/diagnóstico , Imagen por Resonancia Cinemagnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Miocardio/metabolismo , Esfingolípidos/metabolismo , Adolescente , Adulto , Anciano , Cardiomiopatías/diagnóstico , Cardiomiopatías/etiología , Enfermedad de Fabry/complicaciones , Enfermedad de Fabry/metabolismo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Miocardio/patología , Factores de Tiempo , Función Ventricular Izquierda , Adulto Joven
15.
Eur Radiol ; 26(2): 547-55, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26017736

RESUMEN

OBJECTIVES: To compare 3D-inversion-recovery balanced steady-state free precession (IR-bSSFP) non-contrast-enhanced magnetic resonance angiography (MRA) with 3D-contrast-enhanced MRA (CE-MRA) for assessment of renal artery stenosis (RAS) using digital subtraction angiography (DSA) as the reference standard. METHODS: Bilateral RAS were surgically created in 12 swine. IR-bSSFP and CE-MRA were acquired at 1.5 T and compared to rotational DSA. Three experienced cardiovascular radiologists evaluated the IR-bSSFP and CE-MRA studies independently. Linear regression models were used to calibrate and assess the accuracy of IR-bSSFP and CE-MRA, separately, against DSA. The coefficient of determination and Cohen's kappa coefficient were also generated. RESULTS: Calibration of the three readers' RAS grading revealed R(2) values of 0.52, 0.37 and 0.59 for NCE-MRA and 0.48, 0.53 and 0.71 for CE-MRA. Inter-rater agreement demonstrated Cohen's kappa values ranging from 0.25 to 0.65. Distal renal artery branch vessels were visible to a significantly higher degree with NCE-MRA compared to CE-MRA (p < 0.001). Image quality was rated excellent for both sequences, although image noise was higher with CE-MRA (p < 0.05). In no cases did noise interfere with image interpretation. CONCLUSIONS: In a well-controlled animal model of surgically induced RAS, IR-bSSFP based NCE-MRA and CE-MRA accurately graded RAS with a tendency for stenosis overestimation, compared to DSA. KEY POINTS: • IR-bSSFP and CE-MRA are accurate methods for diagnosis of renal artery stenosis • IR-bSSFP and CE-MRA demonstrate excellent agreement with DSA • Both IR-bSSFP and CE-MRA have a tendency to overestimate renal artery stenosis.


Asunto(s)
Angiografía de Substracción Digital/métodos , Angiografía por Resonancia Magnética/métodos , Obstrucción de la Arteria Renal/patología , Animales , Medios de Contraste , Modelos Animales de Enfermedad , Imagenología Tridimensional/métodos , Arteria Renal/patología , Obstrucción de la Arteria Renal/diagnóstico , Reproducibilidad de los Resultados , Porcinos
16.
Rofo ; 187(11): 1016-21, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26230138

RESUMEN

PURPOSE: The role of myocardial triglyceride (mTG) content in the aging human heart is not entirely understood. The aim of this study was to measure concentrations of mTG content from healthy volunteers and to determine the association between age, mTG content and systolic heart function. Furthermore, the technical stability of the (1)H-magnetic resonance spectroscopy ((1)H-MRS) and the reliability of peak evaluation at 3 T were evaluated. MATERIALS AND METHODS: The total study population of 47 healthy volunteers was divided into 4 age classes, according to the age of the subjects (1(st) cohort 20 - 29 years (yrs.), n = 20; 2(nd) cohort 30 - 39 yrs., n = 10; 3(rd) cohort 40 - 49 yrs., n = 9; 4(th) cohort 50 - 60 yrs., n = 8). Cardiac MRI and double triggered (1)H-MRS of the myocardium were consecutively performed using a 3 T scanner. Each participant underwent spectroscopic measurements twice in the same investigation. RESULTS: mTG content increases with age. The correlation of age and mTG is minimal (r = 0.48; p < 0.001). The following age-averaged mTG content values expressed as % of mTG signal compared to the water signal were determined for each cohort: 1(st) cohort 0.25 % (±â€Š0.17); 2(nd) cohort 0.48 % (±â€Š0.30); 3(rd) cohort 0.48 % (±â€Š0.18); 4(th) cohort 0.77 % (±â€Š0.70). There was no significant correlation (r = 0.04; p = n.s.) between LV mass and mTG content in healthy volunteers. Within our cohorts, no effects of age or mTG content on systolic heart function were seen (r = - 0.01; p = n.s.). The intraclass correlation coefficient of spectroscopic measurements was high (r = 0.965; p < 0.001). CONCLUSION: Myocardial TG content increases with age. The normal age-dependent concentration ranges of myocardial lipid metabolites reported in this study may be helpful for the correction of acquired (1)H-MRS data in patients when evaluating metabolic and cardiovascular diseases in future magnetic resonance spectroscopy studies.


Asunto(s)
Envejecimiento/fisiología , Miocardio/metabolismo , Espectroscopía de Protones por Resonancia Magnética/métodos , Triglicéridos/metabolismo , Adulto , Estudios de Cohortes , Frecuencia Cardíaca/fisiología , Tabiques Cardíacos/metabolismo , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Estudios Prospectivos , Valores de Referencia , Volumen Sistólico/fisiología , Adulto Joven
17.
AJNR Am J Neuroradiol ; 36(1): 91-7, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25169925

RESUMEN

BACKGROUND AND PURPOSE: The frequency and amount of intracranial, intradural inflammatory vessel wall enhancement in giant cell arteritis remain unclear. The purpose of this work was to prospectively assess the intracranial extent of vasculitic changes in patients with giant cell arteritis using a dedicated MR imaging protocol optimized for assessment of mural changes of intracranial arteries. MATERIALS AND METHODS: Twenty-eight patients with suspected giant cell arteritis underwent 3T MR imaging. Imaging included a fat-saturated T1WI pre- and postcontrast application optimized for assessment of intradural vessel wall enhancement and high-resolution fat-saturated T1WI to evaluate superficial extracranial vessels. Temporal artery biopsies were available in 11 cases. Vessel wall enhancement of intradural and extracranial vessels was evaluated by 2 observers independently. RESULTS: Twenty patients had giant cell arteritis; 9 cases were biopsy-proved. Clear vessel wall enhancement of superficial extracranial and intradural internal carotid arteries was detected in 16 and 10 patients, respectively. Slight vessel wall enhancement of the vertebral arteries was seen. Of 9 patients with giant cell arteritis with vessel occlusion or stenosis, 2 presented with cerebral ischemic infarcts. Vessel occlusion or stenosis site coincided with the location of vessel wall enhancement of the vertebral arteries in 4 patients and of the intradural ICA in 1 patient. CONCLUSIONS: Vessel wall enhancement of intradural arteries, mainly the ICA, can be regularly found in patients with giant cell arteritis. Mural inflammatory changes of the intradural ICA detected on MR imaging may identify a subgroup of patients with giant cell arteritis and should be further evaluated in clinical studies.


Asunto(s)
Arterias Cerebrales/patología , Arteritis de Células Gigantes/patología , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Arterias/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad
18.
Rofo ; 186(1): 61-6, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24043612

RESUMEN

PURPOSE: Marfan syndrome (MFS) is a genetic disorder of the connective tissue. Aortic root dilation is a main criterion of the Ghent Nosology. Dural ectasia and the presence of mitral valve prolapse (MVP) contribute to its systemic score. The purpose of this study was to investigate the frequency of dural ectasia and its correlation with cardiovascular manifestations in a pediatric study population. PATIENTS AND METHODS: 119 pediatric patients with confirmed or suspected MFS were examined in the local Marfan Clinic. 31 children with MFS who underwent magnetic resonance imaging (MRI) were included. Each patient was evaluated according to the Ghent nosology. Echocardiography was used to measure the aortic root diameter and assess the presence of MVP and mitral regurgitation. Z-scores were calculated for the evaluation of the aortic root diameters. MRI was performed to determine the dural sac ratio (DSR). RESULTS: The prevalence of dural ectasia was 90.3 %, of aortic root dilation 32.2 %, of MVP 64.5 % and of mitral regurgitation 51.6 %. DSR at L5 correlated with the intraindividual z-scores (slope, 3.62 ±â€Š1.5 [0.56; 6.68]; r = 0.17; p = 0.02; F = 5.84). Z-scores ≥ 2 were accompanied by dural ectasia in 100 %, MVP in 95 % and mitral regurgitation in 100 % of cases. MVP was accompanied by mitral regurgitation in 70 % of cases. CONCLUSION: As the examined cardiac manifestations show a coincidence with dural ectasia in 95 - 100 % of cases, MRI for diagnostic dural sac imaging should be reserved for MFS suspicions with the absence of those manifestations in order to establish the diagnosis according to the Ghent criteria. Thus, the present study supports the recent downgrading of dural ectasia to a contributor to the systemic score.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/epidemiología , Duramadre/patología , Imagen por Resonancia Magnética/estadística & datos numéricos , Síndrome de Marfan/diagnóstico , Síndrome de Marfan/epidemiología , Adolescente , Niño , Preescolar , Comorbilidad , Femenino , Alemania/epidemiología , Humanos , Incidencia , Lactante , Masculino , Reproducibilidad de los Resultados , Factores de Riesgo , Sensibilidad y Especificidad , Estadística como Asunto
19.
Rofo ; 185(6): 533-8, 2013 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-23494505

RESUMEN

Many scientific manuscripts submitted for publication are flawed by conceptual mistakes. This leads to the rejection of potentially valuable scientific data in renowned journals. This article intends to guide young researchers with respect to writing a well-structured scientific radiological manuscript.


Asunto(s)
Algoritmos , Investigación Biomédica , Políticas Editoriales , Manuscritos como Asunto , Publicaciones Periódicas como Asunto , Radiología , Escritura
20.
Rofo ; 185(5): 434-9, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23440645

RESUMEN

PURPOSE: In 2011 a nationwide outbreak of Shiga toxin-producing E. coli (STEC) O104:H4 infection occurred in Germany with severe hemorrhagic colitis and hemolytic-uremic syndrome (HUS). We defined abdominal radiologic findings in these patients and correlated them with clinical parameters. MATERIALS AND METHODS: 23 patients (7 men; age: 48 ± 19 years) with O104:H4 colitis and/or HUS received abdominal CT (n = 12) or radiographs (n = 11). Colonic distension, air-fluid levels, and free intraabdominal air were assessed. Colonic wall thickening, contrast enhancement, pericolic stranding, and ascites were evaluated on CT. Laboratory parameters and clinical presentation were reviewed. Chi-square test, Student's t-test, McNemar's test and Spearman correlation were performed. RESULTS: Colonic lumen distension was seen in 16/23 patients (69.6 %). The ascending colon (11/23 patients; 47.8 %) and transverse colon (12/23 patients; 52.2 %) were dilated significantly more often (p = 0.006 and p = 0.003, respectively) than the descending colon (1/23; 4.3 %). All 12 patients undergoing CT scanning had abnormally thickened colonic wall segments, 3 (25 %) had pancolic involvement and 9 (75 %) had segmental involvement. The descending colon was predominantly affected (11/12 patients; 91.7 %) and thickened significantly more often than other colonic segments (p < 0.001). CONCLUSION: The segmental type of STEC O104:H4 colitis mainly affects the descending colon with upstream distension of the transverse/ascending colon and differs from other types of colitis.


Asunto(s)
Colitis/diagnóstico por imagen , Colitis/microbiología , Escherichia coli Enterohemorrágica , Infecciones por Escherichia coli/diagnóstico por imagen , Infecciones por Escherichia coli/microbiología , Colitis/epidemiología , Brotes de Enfermedades/estadística & datos numéricos , Infecciones por Escherichia coli/epidemiología , Femenino , Alemania/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Radiografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA