RESUMEN
Age-related macular degeneration (AMD) is a well-recognized affliction among the elderly, causing vision impairment ranging from blurred vision to complete blindness. This underscores the critical need for accurate, precise, and early detection methods. Herein, we developed a noninvasive, label-free electrical biosensor, constructed on an economical printed circuit board (PCB) substrate, designed specifically for the precise quantification of AMD biomarker: complement component III (C3). The hydrothermally reduced graphene oxide (rGO) was deposited between gold-interdigitated microelectrodes, forming a conductive channel. The fabricated C3 biosensor exhibits a low detection limit of 0.4342 ng/mL and an impressive sensitivity of 9.238 ((ΔR/R)/ng.mL-1)/cm2 with a regression coefficient of 0.9815 calibrated within the clinical C3 range of 10-30 ng/mL. This excellent performance is ascribed to the synergistic effects of 1-pyrenebutanoic acid succinimidyl ester (PBASE) linker and conducting properties of rGO as they generate large active sites for higher anti-C3 antibody immobilization, thereby enhancing sensitivity and specificity. Furthermore, the performance of this proposed C3 sensor chip was validated with enzyme-linked immunosorbent assay (ELISA) using five human tear samples exhibiting an outstanding correlation of a regression value of 0.9774. The unparalleled merits of this newly crafted C3 biosensor transcend those of preceding platforms, boasting superior accuracy and precision in quantifying C3 levels in human tears, accelerated operational speed with results attainable within a mere 15 min, cost-effectiveness, and excellent sensitivity.
Asunto(s)
Biomarcadores , Técnicas Biosensibles , Grafito , Degeneración Macular , Succinimidas , Lágrimas , Grafito/química , Humanos , Succinimidas/química , Biomarcadores/análisis , Lágrimas/química , Ensayo de Materiales , Materiales Biocompatibles/química , Tamaño de la Partícula , Nanoestructuras/química , Óxidos/químicaRESUMEN
Age-related macular degeneration (AMD) is a progressive chronic neurodegenerative retinal disease leading to vision loss, irreversible blindness, and visual impairment in older adults worldwide. Complement component 3 (C3) protein has been identified as the most predominant biomarker towards early diagnosis of AMD; therefore, there is an utmost requirement for non-invasive detection of C3 protein in the tear fluids of AMD patients. Considering this, we report an insightful electrochemical sensor capable of detecting clinically relevant concentrations ranging from 10 fg/mL to 1 µg/mL using electrospun indium-doped zinc oxide (InZnO) nanofibers as the transducing layer. The InZnO nanofibers have facilitated high anti-C3 antibody loading of 3.42 × 10-9 mol/cm2 and enhanced the overall charge transport mechanism at the sensor interface. The biofunctionalization process of the biosensor was investigated thoroughly using X-ray photoelectron spectroscopy (XPS) as well as different electrochemical techniques. The target C3 proteins were captured on the fabricated biosensor surface and determined through changes in charge transfer resistance (RCT) while executing electrochemical impedance spectroscopy (EIS) and peak current (Ip) in the case of cyclic voltammetry (CV) and differential pulse voltammetry (DPV), respectively. The InZnO nanofiber-based nano-biosensor demonstrated a very low limit of detections (LODs) of 5.214 fg/mL and 0.241 fg/mL with an excellent sensitivity of 4.6709 (ΔR/R) (g/mL)-1 cm-2 and 54.4939 (ΔIp/Ip)% (g/mL)-1 cm-2 for EIS and DPV techniques, respectively. By virtue of high antibody loading, ultrasensitive and ultra-selective capability, the indium-doped ZnO nanofibers show huge potential to be used as a high-performance diagnostic platform for AMD diagnosis.
Asunto(s)
Nanofibras , Óxido de Zinc , Humanos , Anciano , Zinc , Complemento C3 , IndioRESUMEN
Cancer is one of the most tormenting global health burdens reporting high mortality and morbidity worldwide. Matrix metalloproteinase 2 (MMP-2) protein has elevated expression for most types of cancers, including prostate and breast cancer. Therefore, accurate and specific detection of MMP-2 biomarker is crucial for screening, treatment, and prognosis of related cancer. In this work, we have proposed a label-free electrochemical biosensor for the detection of MMP-2 protein. This biosensor was fabricated using hydrothermally synthesized vanadium disulfide (VS2) nanosheets with monoclonal anti-MMP2 antibodies biofunctionalized using a suitable linker. The VS2nanomaterials were synthesized hydrothermally at different reaction temperatures (140 °C, 160 °C, 180 °C and 200 °C) generating different morphologies from a 3D bulk cubic structure at 140 °C to 2D nanosheets at 200 °C. Owing to the advantages of 2D VS2nanosheets with high surface-to-volume ratio, excellent electrochemical response and high antibody loading possibility, it was selected for fabricating an MMP-2 specific biosensor. The antibody-antigen binding event is analyzed by recording electrochemical impedance spectroscopy signals for different target MMP-2 protein concentrations. The sensitivity and lower limit of detection were 7.272 (ΔR/R)(ng ml)-1cm-2and 0.138 fg ml-1, respectively in 10 mM phosphate buffer saline for this proposed sensor. Further, interference studies were also performed which demonstrates the sensor to be highly selective against non-specific target proteins. This 2D VS2nanosheet-based electrochemical biosensor is a sensitive, cost-effective, accurate, and selective solution for cancer diagnosis.
Asunto(s)
Técnicas Biosensibles , Nanoestructuras , Neoplasias , Metaloproteinasa 2 de la Matriz , Biomarcadores de Tumor , Límite de Detección , Nanoestructuras/química , Técnicas Biosensibles/métodos , Técnicas Electroquímicas/métodos , Neoplasias/diagnósticoRESUMEN
A sensitive, non-invasive, and biomarker detection in tear fluids for inflammation in potentially blinding eye diseases could be of great significance as a rapid diagnostic tool for quick clinical decisions. In this work, we propose a tear-based MMP-9 antigen testing platform using hydrothermally synthesized vanadium disulfide nanowires. Also, various factors contributing to baseline drifts of the chemiresistive sensor including nanowire coverage on the interdigitated microelectrode of the sensor, sensor response duration, and effect of MMP-9 protein in different matrix solutions were identified. The drifts on the sensor baseline due to nanowire coverage on the sensor were corrected using substrate thermal treatment providing a more uniform distribution of nanowires on the electrode which brought the baseline drift to 18% (coefficient of variations, CV = 18%). This biosensor exhibited sub-femto level limits of detection (LODs) of 0.1344 fg/mL (0.4933 fmoL/l) and 0.2746 fg/mL (1.008 fmoL/l) in 10 mM phosphate buffer saline (PBS) and artificial tear solution, respectively. For a practical tear MMP-9 detection, the proposed biosensor response was validated with multiplex ELISA using tear samples from five healthy controls which showed excellent precision. This label-free and non-invasive platform can serve as an efficient diagnostic tool for the early detection and monitoring of various ocular inflammatory diseases.