Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros

Base de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Sensors (Basel) ; 24(15)2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39123863

RESUMEN

Reimaging telescopes have an accessible exit pupil that facilitates stray light mitigation and matching to auxiliary optical systems. Freeform surfaces present the opportunity for unobscured reflective systems to be folded into geometries that are otherwise impracticable with conventional surface types. It is critical, however, to understand the limitations of the enabled folding geometries and choose the one that best balances the optical performance and mechanical requirements. Here, we used the aberration theory of freeform surfaces to determine the aberration correction potential for using freeform surfaces in reimaging three-mirror telescopes and established a hierarchy for the different folding geometries without using optimization. We found that when using freeform optics, the ideal folding geometry had 9× better wavefront performance compared to the next best geometry. Within that ideal geometry, the system using freeform optics had 39% better wavefront performance compared to a system using off-axis asphere surfaces, thus quantifying one of the advantages of freeform optics in this design space.

2.
bioRxiv ; 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38854135

RESUMEN

By combining an external display operating at 360 frames per second with an Adaptive Optics Scanning Laser Ophthalmoscope (AOSLO) for human foveal imaging, we demonstrate color stimulus delivery at high spatial and temporal resolution in AOSLO psychophysics experiments. A custom pupil relay enables viewing of the stimulus through a 3-mm effective pupil diameter and provides refractive error correction from -8 to +4 diopters. Performance of the assembled and aligned pupil relay was validated by measuring the wavefront error across the field of view and correction range, and the as-built Strehl ratio was 0.64 or better. High-acuity stimuli were rendered on the external display and imaged through the pupil relay to demonstrate that spatial frequencies up to 54 cycles per degree, corresponding to 20/11 visual acuity, are resolved. The completed external display was then used to render fixation markers across the field of view of the monitor, and a continuous retinal montage spanning 9.4 by 5.4 degrees of visual angle was acquired with the AOSLO. We conducted eye-tracking experiments during free-viewing and high-acuity tasks with polychromatic images presented on the external display. Sub-arcminute eye position uncertainty was achieved, enabling precise localization of the line of sight on the monitor while simultaneously imaging the fine structure of the human central fovea. This high refresh rate display overcomes the temporal, spectral, and field of view limitations of AOSLO-based stimulus presentation, enabling natural monocular viewing of stimuli in psychophysics experiments conducted with AOSLO.

3.
Opt Express ; 32(11): 20011-20023, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38859120

RESUMEN

Zernike polynomial orthogonality, an established mathematical principle, is leveraged with the Gauss-Legendre quadrature rule in a rapid novel approach to fitting data over a circular domain. This approach provides significantly faster fitting speeds, in the order of thousands of times, while maintaining comparable error rates achieved with conventional least-square fitting techniques. We demonstrate the technique for fitting mid-spatial-frequencies (MSF) prevalent in small-tool-manufacturing typical of aspheric and freeform optics that are poised to soon permeate a wide range of optical technologies.

4.
Opt Express ; 32(12): 20959-20975, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38859463

RESUMEN

This paper presents a method for evaluating the irradiance of a single freeform surface deviation under extended source illumination. The method takes advantage of a well-known concept, the pinhole image. First, the irradiance of the perturbed freeform surface under point source illumination is computed. Second, a pinhole image of the extended source is obtained by placing a small aperture (pinhole) on the freeform surface. Then, the extended source irradiance pattern change can be quickly calculated by convolving the pinhole image with the perturbed point source irradiance change. The method was experimentally verified, demonstrating the efficacy of the underlying concept. The proposed method alleviates the computational demands during extended source tolerancing, expediting the process.

5.
Neuroimage ; 295: 120662, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38823503

RESUMEN

Understanding the physiological processes in aging and how neurodegenerative disorders affect cognitive function is a high priority for advancing human health. One specific area of recently enabled research is the in vivo biomechanical state of the brain. This study utilized reverberant optical coherence elastography, a high-resolution elasticity imaging method, to investigate stiffness changes during the sleep/wake cycle, aging, and Alzheimer's disease in murine models. Four-dimensional scans of 44 wildtype mice, 13 mice with deletion of aquaporin-4 water channel, and 12 mice with Alzheimer-related pathology (APP/PS1) demonstrated that (1) cortical tissue became softer (on the order of a 10% decrease in shear wave speed) when young wildtype mice transitioned from wake to anesthetized, yet this effect was lost in aging and with mice overexpressing amyloid-ß or lacking the water channel AQP4. (2) Cortical stiffness increased with age in all mice lines, but wildtype mice exhibited the most prominent changes as a function of aging. The study provides novel insight into the brain's biomechanics, the constraints of fluid flow, and how the state of brain activity affects basic properties of cortical tissues.


Asunto(s)
Envejecimiento , Enfermedad de Alzheimer , Encéfalo , Diagnóstico por Imagen de Elasticidad , Sueño , Animales , Enfermedad de Alzheimer/diagnóstico por imagen , Enfermedad de Alzheimer/fisiopatología , Envejecimiento/fisiología , Diagnóstico por Imagen de Elasticidad/métodos , Ratones , Encéfalo/diagnóstico por imagen , Encéfalo/fisiopatología , Sueño/fisiología , Vigilia/fisiología , Ratones Transgénicos , Acuaporina 4/metabolismo , Acuaporina 4/genética , Masculino , Ratones Endogámicos C57BL
6.
Opt Express ; 32(6): 9967-9981, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38571220

RESUMEN

Waveguide displays have been shown to exhibit multiple interactions of light at the in-coupler diffractive surface, leading to light loss. Any losses at the in-coupler set a fundamental upper limit on the full-system efficiency. Furthermore, these losses vary spatially across the beam for each field, significantly decreasing the displayed image quality. We present a framework for alleviating the losses based on irradiance, efficiency, and MTF maps. We then derive and quantify the innate tradeoff between the in-coupling efficiency and the achievable modulation transfer function (MTF) characterizing image quality. Applying the framework, we show a new in-coupler architecture that mitigates the efficiency vs image quality tradeoff. In the example architecture, we demonstrate a computation speed that is 2,000 times faster than that of a commercial non-sequential ray tracer, enabling faster optimization and more thorough exploration of the parameter space. Results show that with this architecture, the in-coupling efficiency still meets the fundamental limit, while the MTF achieves the diffraction limit up to and including 30 cycles/deg, equivalent to 20/20 vision.

7.
Opt Express ; 32(4): 6154-6167, 2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38439325

RESUMEN

An approach to designing multiconfiguration afocal telescopes is developed and demonstrated. Freeform surfaces are used to maximize the achievable diffraction-limited zoom ratio while staying in a compact volume for a two-position multiconfiguration afocal optical system. The limitations of these systems with three-mirror beam paths are discussed and subsequently overcome by introducing an additional degree of freedom. In a four-mirror beam path system, the goal of a 5x zoom ratio is achieved with a compensated exit pupil and diffraction-limited performance. A significant benefit in optical performance when using freeform surfaces is shown compared to more conventional surface types.

8.
Opt Express ; 32(2): 2688-2703, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38297792

RESUMEN

We propose a workflow for modeling generalized mid-spatial frequency (MSF) errors in optical imaging systems. This workflow enables the classification of MSF distributions, filtering of bandlimited signatures, propagation of MSF errors to the exit pupil, and performance predictions that differentiate performance impacts due to the MSF distributions. We demonstrate the workflow by modeling the performance impacts of MSF errors for both transmissive and reflective imaging systems with near-diffraction-limited performance.

9.
Appl Opt ; 63(3): 730-742, 2024 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-38294386

RESUMEN

In prior art, advances in adaptive optics scanning laser ophthalmoscope (AOSLO) technology have enabled cones in the human fovea to be resolved in healthy eyes with normal vision and low to moderate refractive errors, providing new insight into human foveal anatomy, visual perception, and retinal degenerative diseases. These high-resolution ophthalmoscopes require careful alignment of each optical subsystem to ensure diffraction-limited imaging performance, which is necessary for resolving the smallest foveal cones. This paper presents a systematic and rigorous methodology for building, aligning, calibrating, and testing an AOSLO designed for imaging the cone mosaic of the central fovea in humans with cellular resolution. This methodology uses a two-stage alignment procedure and thorough system testing to achieve diffraction-limited performance. Results from retinal imaging of healthy human subjects under 30 years of age with refractive errors of less than 3.5 diopters using either 680 nm or 840 nm light show that the system can resolve cones at the very center of the fovea, the region where the cones are smallest and most densely packed.


Asunto(s)
Fóvea Central , Oftalmoscopios , Enfermedades de la Retina , Humanos , Calibración , Fóvea Central/diagnóstico por imagen , Rayos Láser , Errores de Refracción , Enfermedades de la Retina/diagnóstico por imagen
10.
Light Sci Appl ; 13(1): 22, 2024 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-38233407

RESUMEN

Augmented reality (AR), which emerged in the 1960s, remains a focal point of interest given its capacity to overlay the real world with digitally presented information through optical combiners. The prevalent combiner, commonly known as the waveguide in the AR literature, is prized for its compact design and generous eyebox-essential elements in human-centric technology. Nonetheless, these combiners encounter unique challenges in meeting various other requirements of the human visual system. This paper highlights a recent review of technological advancements and presents a forward-looking perspective on the future of AR technology.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA