Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Int J Biometeorol ; 2024 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-39316162

RESUMEN

Mitigating Urban Heat Island (UHI) intensity in cities through adaptative strategies has become an urgent need, as UHI are also exacerbated by climate change impacts imputable to anthropogenic actions. This study addresses the need for reliable simulation models to analyze outdoor thermal comfort (OTC) in future or alternative scenarios. The aim of the present study is to contribute to the validation of CFD urban microclimate simulations by employing intra-urban canyon transects as an alternative or a complementary approach to fixed stations. To accomplish this, we developed a cost-effective monitoring unit to carry out transects on a pre-defined route (1), devised the area of interest (2), elaborated a simulation model in ENVI-met (3), and proposed different validation methods for comparative analyses (4). Results indicate that temporal validated simulation tended to underestimate thermal indices in the morning and night and overestimate them in the afternoon, while spatio-temporal validation under a human-centric comfort approach via wearable sensing notably improved accuracy. Moderate to very strong agreement between simulation and measurement data in summer (Willmot's d ~ 0.70, d ~ 0.81) and very strong agreement in winter (d ~ 0.79, d ~ 0.96), with low error magnitudes in summer (RMSE ~ 0.91℃ and 9.59%, MBE ~ 0.23℃ and 9.10%) have been found. In winter, such figures were RMSE ~ 0.71℃ and 3.51%, MBE ~ 0.00℃ and 0.98%, for the spatio-temporal validated model. This research contributes to enhancing the reliability of relatively affordable CFD urban microclimate simulations, supporting its scale up for policymakers in implementing effective strategies for OTC.

2.
ACS Sens ; 8(12): 4504-4511, 2023 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-38033269

RESUMEN

The ability to monitor dynamic changes in neuropeptide Y (NPY) levels in complex environments can have an impact on many fields, including neuroscience and immunology. Here, we describe the development of an electrochemical, aptamer-based (E-AB) sensor for the dynamic (reversible) measurement of physiologically relevant (nanomolar) concentrations of neuropeptide Y. The E-AB sensors are fabricated using a previously described 80 nucleotide aptamer1 reported to specifically bind NPY with a binding affinity Kd = 0.3 ± 0.2 uM. We investigated two redox tag placement locations on the aptamer sequence (terminal vs internal) and various sensor fabrication and interrogation parameters to tune the performance of the resulting sensor. The best-performing sensor architecture displayed a physiologically relevant dynamic range (nM) and low limit of detection and is selective among competitors and similar molecules. The development of this sensor accomplishes two breakthroughs: first, the development of a nonmicrofluidic aptamer-based electrochemical sensor that can detect NPY on a physiologically relevant (seconds to minutes) time scale and across a relevant concentration range; second, the expansion of the range of molecules for which an electrochemical, aptamer-based sensor can be used.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Neuropéptido Y/metabolismo , Aptámeros de Nucleótidos/química , Técnicas Biosensibles/métodos , Oxidación-Reducción
3.
Pak J Med Sci ; 38(3Part-I): 674-681, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35480526

RESUMEN

Objectives: Diabetes mellitus (DM) is a common endocrine disease with serious effects on multiple organs including the kidneys. This study aimed to investigate the subtle effects of type 2 DM (T2DM) on the kidneys. Methods: This was a prospective case-control study conducted in the Radiology Department of University of Science and Technology Hospital (USTH) campus, Sana'a, Republic of Yemen, from 1 January 2020 to 31 November 2020. The renal length (RL), renal width (RW), resistive index (RI), and pulsatility index (PI) were prospectively measured in patients with T2DM and healthy controls. The results were compared using the independent samples t-test. Comparisons were likewise performed between patients with controlled DM and patients with uncontrolled DM. Results: A total of hundred individuals, 50 diabetic patients and 50 controls, were enrolled in this study. Their mean age was 54 ± 7.88 years (range: 40-75 years). The RL, RI, and PI of both kidneys were significantly higher in T2DM than in the control group. Moreover, the RL, RI, PI and creatinine were slightly higher in patients with uncontrolled than in those with controlled DM. Conclusion: T2DM has significant accentuating effects on the RL, RI and PI associated with low effective renal plasma flow, even before acute kidney injury or chronic kidney disease diagnosis, which may be attenuated by careful regulation of DM. Ultrasound Doppler is a highly valuable imaging modality for evaluating the subtle effects of T2DM on kidney dimensions and blood flow. The RI can be implemented as a tool for the early diagnosis of kidney disease and contribute to slowing the disease progression and preventing renal failure.

4.
Environ Int ; 158: 106942, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34689038

RESUMEN

The short-term associations of fine particulate matter (PM2.5) and coarse particulate matter (PM2.5-10) with pulmonary function were inconsistent and rarely evaluated by dynamic measurements. Our study aimed to investigate the associations of PM2.5 and PM2.5-10 with real-time pulmonary function. We conducted a longitudinal study based on dynamic pulmonary function measurements among adult asthmatic patients in 25 cities of 19 provincial regions of China from 2017 to 2020. Linear mixed-effects models combined with polynomial distributed lag models were used for statistical analysis. A total of 298,396 records among 4,992 asthmatic patients were evaluated. We found generally inverse associations of PM2.5 and PM2.5-10 with 16 pulmonary function indicators that were independent of gaseous pollutants. The associations occurred at lag 1 d, became the strongest at lag 4 d, and vanished a week later. PM2.5-10 had stronger associations than PM2.5, especially in southern China. Nationally, an interquartile increase in PM2.5-10 (28.0 µg/m3) was significantly associated with decreases in forced expiratory volume in 1 s (FEV1, 41.6 mL), the ratio of FEV1 in forced vital capacity (1.1%), peak expiratory flow (136.9 mL/s), and forced expiratory flow at 25-75% of forced vital capacity (54.3 mL/s). We observed stronger associations in patients of male, BMI ≥ 25 kg/m2, age ≥ 45 years old, and during warm seasons. In conclusion, this study provided robust evidence for impaired pulmonary function by short-term exposure to PM2.5 and PM2.5-10 in asthmatic patients using the largest dataset of dynamic monitoring. The associations can last for one week and PM2.5-10 may be more hazardous.


Asunto(s)
Contaminantes Atmosféricos , Contaminación del Aire , Adulto , Contaminantes Atmosféricos/análisis , Contaminantes Atmosféricos/toxicidad , Contaminación del Aire/análisis , Contaminación del Aire/estadística & datos numéricos , China/epidemiología , Ciudades , Exposición a Riesgos Ambientales/análisis , Exposición a Riesgos Ambientales/estadística & datos numéricos , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Material Particulado/análisis
5.
Anal Bioanal Chem ; 413(11): 3081-3091, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33733702

RESUMEN

In plant research, measuring the physiological parameters of plants is vital for understanding the behavior and response of plants to changes in the external environment. Plant sap analysis provides an approach for elucidating the physiological condition of plants. However, to facilitate accurate sap analysis, a sampling device capable of collecting sap samples from plants is required. In this paper, a minimally invasive, needle-type micro-sampling device capable of collecting nanoliter (~ 91 nL) quantities of sap from plants is described. The developed micro-sampling system showed great reproducibility (3%) in experiments designed to assess sampling performance. As a proof of concept, sap samples were collected continuously from target plants with the micro-sampling system, and the dynamic changes in potassium ions, plant hormones and sugar levels inside plants were analyzed. The results demonstrated the feasibility of the micro-sampling device and its potential for developing a measurement system for plant research in the future.


Asunto(s)
Agujas , Plantas/química , Manejo de Especímenes/instrumentación , Espectrometría de Masas/métodos
6.
J Food Sci ; 85(11): 3885-3898, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33063351

RESUMEN

Although the ice phase greatly influences the properties of ice cream, other structural components also affect its rheological behavior, particularly after melting. In this study, mix viscosity (serum phase viscosity), extent of fat destabilization (FD), and overrun were manipulated to produce different microstructures. The effects of these structural components were evaluated on the rheological properties of the ice creams and melted ice creams. In oscillatory thermorheometry, mix viscosity and then overrun, influenced G' and tanδ below -10 °C. When ice phase decreased (between -10 and -2.7 °C), mix viscosity had reduced effects, but continued to strongly affect G' and tanδ, followed by FD, and with lower effects from overrun. When the ice phase was completely melted at 0 °C, FD had most influence on G' and tanδ, followed by overrun, and with lower effects from mix viscosity. In creep/recovery test, six-element model described well creep behavior of melted ice cream at 0 °C. Viscous behavior at lower shear rate (η0 0 °C) was most influenced by mix viscosity, followed by FD, and lower overrun effects. In stress growth measurement, transient behavior, represented by σY 0 °C, of melted matrix at 0 °C was most influenced by FD, followed by mix viscosity, with lower overrun effects. In flow ramp measurement, Hysteresis Area was most affected by mix viscosity, followed by overrun, and with lower FD effects. Moreover, correlation between Hyst 0 °C and tanδ Peak suggested that structure formation affected the magnitude of tanδ Peak. These results document the importance of microstructure on properties of melted ice cream. PRACTICAL APPLICATION: The understanding of how structural components, such as mix viscosity, fat destabilization, and overrun, affect the ice cream matrix can help manufacturers to control its rheological behavior. The influence of these structural components on the G', tanδ, η0 0 °C , σY 0 °C , and Hyst 0 °C can be also used to understand the structural rearrangements that occur in meltdown tests and sensory analyses for future studies. Therefore, elucidation of these mechanisms on the rheological properties can directly assist in quality control and new product development in the ice cream industry.


Asunto(s)
Helados/análisis , Leche/química , Animales , Bovinos , Congelación , Fenómenos Físicos , Reología , Viscosidad
7.
J Fluoresc ; 30(6): 1421-1430, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32935195

RESUMEN

We evaluated the ability of different fluorescent indicators by various analytical instruments, including a laser scanning confocal microscope (LSCM), fluorescence plate reader, and flow cytometer (FCM), to measure the mitochondrial membrane potential (ΔΨm) of cardiac H9c2 cells during oxidative stress-induced mitochondrial injury. The mitochondrial oxygen consumption rate and a transmission electron microscope were used to detect changes in mitochondrial functions and morphology, respectively. Cardiac H9c2 cells were exposed to H2O2 (500, 750, 1000, and 1250 µM) to induce mitochondrial oxidative stress injury, and fluorescent indicators including tetramethyl rhodamine ethyl ester (TMRE), 5,5',6,6'-tetrachloro-1,1',3,3'-tetraethylbenzimidazolocarbocyanine iodide (JC-1), and rhodamine 123 (R123) were used to detect changes in ΔΨm using an LSCM, fluorescence plate reader, and FCM. The decrease in ΔΨm caused by H2O2 was determined by endpoint and dynamic analyses after staining with JC-1 or TMRE. With the R123 probe, the LSCM could only detect the change in ΔΨm caused by 1000 µM H2O2. Moreover, R123 was less effective than JC-1 and TMRE for measurement of ΔΨm by the LSCM. Our data indicated that an LSCM is the most suitable instrument to detect dynamic changes in ΔΨm, whereas all three instruments can detect ΔΨm at the endpoint.


Asunto(s)
Colorantes Fluorescentes/metabolismo , Potencial de la Membrana Mitocondrial , Mitocondrias Cardíacas/metabolismo , Estrés Oxidativo , Animales , Línea Celular , Mitocondrias Cardíacas/patología , Ratas , Especies Reactivas de Oxígeno/metabolismo
8.
Foods ; 9(7)2020 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-32635274

RESUMEN

When food is ingested, it remains in the mouth for a short period of time. Although this period is brief compared to the total food nutrient digestion and absorption time, it is crucially important as it is the first step in digestion. It is also very important that, while the food is in the mouth, it is perceived by the senses and then a decision is made on swallowing. Oral sensory perception is an integrative response, which is generated in very short time (normally a few seconds) from complex information gathered from multiple sources during mastication and swallowing. Consequently, food oral processing studies include many orientations. This Special Issue brings together a small range of studies with a diversity of approaches that provide good examples of the complexity and multidisciplinarity of the subject.

9.
Sensors (Basel) ; 19(12)2019 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-31212852

RESUMEN

3D-printing technology is opening up new possibilities for the co-printing of sensory elements. While quasi-static research has shown promise, the dynamic performance has yet to be researched. This study researched smart 3D structures with embedded and printed sensory elements. The embedded strain sensor was based on the conductive PLA (Polylactic Acid) material. The research was focused on dynamic measurements of the strain and considered the theoretical background of the piezoresistivity of conductive PLA materials, the temperature effects, the nonlinearities, the dynamic range, the electromagnetic sensitivity and the frequency range. A quasi-static calibration used in the dynamic measurements was proposed. It was shown that the temperature effects were negligible, the sensory element was linear as long as the structure had a linear response, the dynamic range started at ∼ 30 µ ϵ and broadband performance was in the range of few kHz (depending on the size of the printed sensor). The promising results support future applications of smart 3D-printed systems with embedded sensory elements being used for dynamic measurements in areas where currently piezo-crystal-based sensors are used.

10.
Anal Bioanal Chem ; 411(19): 4339-4347, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30854595

RESUMEN

The quantity and activity of proteins in many biological systems exhibit prominent heterogeneities. Single-cell analytical methods can resolve subpopulations and dissect their unique signatures from heterogeneous samples, enabling a clarifying view of the biological process. Over the last 5 years, technologies for single-cell protein analysis have significantly advanced. In this article, we highlight a branch of those technology developments involving fluorescence-based approaches, with a focus on the methods that increase the ability to multiplex and enable dynamic measurements. We also analyze the limitations of these techniques and discuss current challenges in the field, with the hope that more transformative platforms can soon emerge.


Asunto(s)
Imagen Óptica/métodos , Proteínas/química , Análisis de la Célula Individual
11.
Sensors (Basel) ; 19(2)2019 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-30634673

RESUMEN

Measurements of deformations by means of vibrating wire sensors are very important in the monitoring of building structures. These types of sensors are characterized by a high resistance to environmental conditions, long time of measurement stability, and a possibility to use long electric cables with a solid encasement in concrete. Vibrating wire sensors are mainly used for measuring stable or slowly changing deformations, however applications of these sensors for measuring time-variable deformations are becoming popular. New solutions generate new problems, which in case of vibrating wire sensors are mainly related to the operational stability of the systems exciting wire vibrations. The structure of such sensors and the length of the electric cables, which can reach a few kilometers, have an essential influence on their operations. This paper undertakes the task of determining the influence of the electric cables length on the proper operation of the measurement system and provides advice for improvements of its measurement possibilities. The subject of investigation constitutes a measurement system based on a self-exciting impulse exciter, for which the impedance of the electric cables and of the vibrating wire sensor are the most essential parameters. A mathematical model of this system, experimental verification of the model, and the results of theoretical analyses and measurement tests for electric cables of various lengths are presented in this paper.

12.
Lasers Med Sci ; 33(3): 627-635, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29383502

RESUMEN

The aim of this study is to evaluate the influences of different bone graft heights on the size of the intervertebral foramen, which will help determine the optimal graft height in clinical practice. Six fresh adult cadavers were used, with the C5-C6 vertebral column segment defined as the functional spinal unit (FSU). After discectomy, the C5/6 intervertebral height was set as the baseline height (normal disc height). We initially used spiral computed tomography (CT) to scan and measure the middle area of the intervertebral foramen when at the baseline height. Data regarding the spatial relationship of C5-C6 were subsequently collected with a laser scanner. Grafting with four different sized grafts, namely, grafts of 100, 130, 160, and 190% of the baseline height, was implanted. Moreover, we scanned to display the FSU in the four different states using Geomagic8.0 studio software. Multiple planar dynamic measurements (MPDM) were adopted to measure the intervertebral foramen volume, middle area, and areas of internal and external opening. MPDM with a laser scanner precisely measured the middle area of the intervertebral foramen as spiral CT, and it is easy to simulate the different grafts implanted. With the increase of the bone graft height, the size of the intervertebral foramen began to decrease after it increased to a certain point, when grafts of 160% of the baseline height implanted. MPDM of the intervertebral foramens with laser scanning three-dimensional (3D) reconstitution are relatively objective and accurate. The recommended optimal graft height of cervical spondylosis is 160% of the mean height of adjacent normal intervertebral spaces.


Asunto(s)
Trasplante Óseo , Vértebras Cervicales/efectos de la radiación , Vértebras Cervicales/trasplante , Disco Intervertebral/anatomía & histología , Disco Intervertebral/efectos de la radiación , Rayos Láser , Adulto , Cadáver , Vértebras Cervicales/diagnóstico por imagen , Femenino , Humanos , Imagenología Tridimensional , Disco Intervertebral/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Rayos X , Adulto Joven
13.
Sensors (Basel) ; 17(5)2017 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-28524078

RESUMEN

This paper evaluates the performance of direct interface circuits (DIC), where the sensor is directly connected to a microcontroller, when a resistive sensor subjected to dynamic changes is measured. The theoretical analysis provides guidelines for the selection of the components taking into account both the desired resolution and the bandwidth of the input signal. Such an analysis reveals that there is a trade-off between the sampling frequency and the resolution of the measurement, and this depends on the selected value of the capacitor that forms the RC circuit together with the sensor resistance. This performance is then experimentally proved with a DIC measuring a magnetoresistive sensor exposed to a magnetic field of different frequencies, amplitudes, and waveforms. A sinusoidal magnetic field up to 1 kHz can be monitored with a resolution of eight bits and a sampling frequency of around 10 kSa/s. If a higher resolution is desired, the sampling frequency has to be lower, thus limiting the bandwidth of the dynamic signal under measurement. The DIC is also applied to measure an electrocardiogram-type signal and its QRS complex is well identified, which enables the estimation, for instance, of the heart rate.

14.
Sensors (Basel) ; 16(12)2016 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-27898043

RESUMEN

Optical frequency combs (OFC) generated by electro-optic modulation of continuous-wave lasers provide broadband coherent sources with high power per line and independent control of line spacing and the number of lines. In addition to their application in spectroscopy, they offer flexible and optimized sources for the interrogation of other sensors based on wavelength change or wavelength filtering, such as fiber Bragg grating (FBG) sensors. In this paper, a dual-OFC FBG interrogation system based on a single laser and two optical-phase modulators is presented. This architecture allows for the configuration of multimode optical source parameters such as the number of modes and their position within the reflected spectrum of the FBG. A direct read-out is obtained by mapping the optical spectrum onto the radio-frequency spectrum output of the dual-comb. This interrogation scheme is proposed for measuring fast phenomena such as vibrations and ultrasounds. Results are presented for dual-comb operation under optimized control. The optical modes are mapped onto detectable tones that are multiples of 0.5 MHz around a center radiofrequency tone (40 MHz). Measurements of ultrasounds (40 kHz and 120 kHz) are demonstrated with this sensing system. Ultrasounds induce dynamic strain onto the fiber, which generates changes in the reflected Bragg wavelength and, hence, modulates the amplitude of the OFC modes within the reflected spectrum. The amplitude modulation of two counterphase tones is detected to obtain a differential measurement proportional to the ultrasound signal.

15.
Curr Protoc Mouse Biol ; 6(3): 256-271, 2016 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-27584553

RESUMEN

This article describes detailed protocols for in vitro measurements of insulin function and secretion in isolated mouse islets for the analysis of glucose homeostasis. We specify a method of enzyme digestion and hand picking to isolate and release the greatest number of high quality islets from the pancreas of the mouse. We describe an effective method for generating dynamic measurements of insulin secretion using a perifusion assay including a detailed protocol for constructing a peristaltic pump and tubing assembly. In addition we describe an alternative and simple technique for measuring insulin secretion using static incubation of isolated islets. © 2016 by John Wiley & Sons, Inc.


Asunto(s)
Insulina/metabolismo , Islotes Pancreáticos/metabolismo , Ratones/metabolismo , Fisiología/métodos , Animales , Secreción de Insulina
16.
Sensors (Basel) ; 15(10): 27174-200, 2015 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-26516854

RESUMEN

The measurement of the internal deformations occurring in real-life composite components is a very challenging task, especially for those components that are rather difficult to access. Optical fiber sensors can overcome such a problem, since they can be embedded in the composite materials and serve as in situ sensors. In this article, embedded optical fiber Bragg grating (FBG) sensors are used to analyze the vibration characteristics of two real-life composite components. The first component is a carbon fiber-reinforced polymer automotive control arm; the second is a glass fiber-reinforced polymer aeronautic hinge arm. The modal parameters of both components were estimated by processing the FBG signals with two interrogation techniques: the maximum detection and fast phase correlation algorithms were employed for the demodulation of the FBG signals; the Peak-Picking and PolyMax techniques were instead used for the parameter estimation. To validate the FBG outcomes, reference measurements were performed by means of a laser Doppler vibrometer. Sensors 2015, 15 27175 The analysis of the results showed that the FBG sensing capabilities were enhanced when the recently-introduced fast phase correlation algorithm was combined with the state-of-the-art PolyMax estimator curve fitting method. In this case, the FBGs provided the most accurate results, i.e. it was possible to fully characterize the vibration behavior of both composite components. When using more traditional interrogation algorithms (maximum detection) and modal parameter estimation techniques (Peak-Picking), some of the modes were not successfully identified.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA