Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.348
Filtrar
Más filtros

Intervalo de año de publicación
1.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(6): 635-640, 2024 Jun 15.
Artículo en Chino | MEDLINE | ID: mdl-38918180

RESUMEN

Objective: To review the development and research progress of suture button fixation Latarjet procedure. Methods: A comprehensive literature review was conducted to summarize the development and related modified techniques of the suture button fixation Latarjet procedure. Results: Since the Latarjet procedure was first introduced by French scholar Latarjet in 1954, it has undergone three key transformations, resulting in suture button fixation Latarjet procedure, which has shown satisfactory outcomes in treatment of recurrent shoulder dislocation. However, there are still drawbacks such as the risk of impingement of the graft on surrounding tissues, and the surgical disruption of anatomical structures like the coracoclavicular ligament and the pectoralis minor muscle. The scholars have proposed several modified techniques based on the suture button fixation Latarjet procedure to further reduce complications from impingement of the graft, to lower the glenohumeral contact pressure, and to eliminate the impact of surgery on the physiological structures of the shoulder joint. The modified techniques include the arthroscopic suture button fixation Latarjet procedure using FiberTape Cerclage, reconstruction of the coracoacromial ligament during congruent-arc Latarjet procedures, and limit unique coracoid osteotomy suture button Latarjet procedure (LU-tarjet procedure). These modified techniques have also shown good clinical outcomes. Additionally, other related modified techniques for reconstruction of the glenoid, such as Chinese unique Inlay Bristow procedure (Cuistow procedure), arthroscopic glenoid bone grafting with soft fixation, and all-arthroscopic modified Eden-Hybinette procedure, have also demonstrated favorable efficacy. However, there is still a lack of long-term follow-up results for these techniques and comparative studies between them. Conclusion: Suture button fixation Latarjet procedure is an effective method for the treatment of recurrent shoulder dislocation. There are various techniques, but there is no recognized gold standard, and further clinical and basic research is needed.


Asunto(s)
Artroscopía , Luxación del Hombro , Articulación del Hombro , Técnicas de Sutura , Humanos , Artroscopía/métodos , Luxación del Hombro/cirugía , Articulación del Hombro/cirugía , Trasplante Óseo/métodos , Suturas , Anclas para Sutura , Resultado del Tratamiento , Inestabilidad de la Articulación/cirugía , Rango del Movimiento Articular , Ligamentos Articulares/cirugía
2.
BMJ Case Rep ; 17(6)2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38839412

RESUMEN

Fractures of the proximal humerus with medial column instability are challenging and present an unacceptable rate of complications and reoperations. Despite good results reported with the use of locking plates and augmentation techniques using bone graft or a second plate, varus subsidence and fixation failure have been frequently reported. We describe the case of a patient presenting with a complex, multifragmentary proximal humerus fractures successfully treated with open anatomic reduction and internal fixation using a locking plate augmented with lateral traction using three bone anchors in the humerus head. After 18 months, the patient reported fully recovering the mobility and functionality of the operated shoulder. The use of bone anchors pulling the humeral in three different directions like three vectors applied from medial to lateral, posterior to anterior and lateral to anterior help to reduce the most important deformities (varus and retroversion) by applying the tension band principle. This is an interesting approach to avoid primary and secondary reduction loss of the proximal fractures of the humerus with postero-medial cortical defect. The procedure is a good alternative to be used in patients with failure or insufficiency of the medial wall and marked varus.


Asunto(s)
Fijación Interna de Fracturas , Fracturas del Hombro , Humanos , Fracturas del Hombro/cirugía , Fijación Interna de Fracturas/métodos , Placas Óseas , Técnicas de Sutura , Masculino , Inestabilidad de la Articulación/cirugía , Anclas para Sutura , Persona de Mediana Edad , Resultado del Tratamiento
3.
Med Eng Phys ; 129: 104191, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38906573

RESUMEN

The mechanical interaction of a tilting anchor and cancellous bones of various densities was simulated using finite element modeling. The model enjoyed a sophisticated representation of the bone, as an elasto-plastic material with large deformation capability. The anchor's tilting action during implantation phase, as well as its fixation stiffness during pull-out test, were predicted by the model and a parametric study was performed to investigate the effects of the anchor's distal width and corner fillet radius, on these measures. The model predictions were validated against the results of an experimental test on ovine humerus specimens. The model could reasonably reproduce the tilting action of the anchor during the implantation phase. Comparison of the model predictions with the experimental results revealed similar trends during both the implantation and the pull-out phases, but smaller displacement magnitudes (end points: 1.4 vs. 2.1 mm and 4.6 vs. 5.2 mm, respectively). The results of the parametric study indicated substantial increase in the fixation stiffness with increasing bone density. Reducing the distal width and increasing the fillet radius improved the anchor's implantation configuration and fixation stiffness in low-density bones. For high-density bone applications, however, a larger distal width was favored for improving the fixation stiffness.


Asunto(s)
Análisis de Elementos Finitos , Animales , Ovinos , Fenómenos Biomecánicos , Fenómenos Mecánicos , Anclas para Sutura , Húmero/fisiología , Húmero/cirugía , Diseño de Equipo , Densidad Ósea
4.
Otol Neurotol ; 45(6): 676-683, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38865727

RESUMEN

HYPOTHESIS: Resonance frequency analysis (RFA) is a reliable, noninvasive method to assess the stability of bone-anchored hearing implants (BAHIs), although surgical-, implant-, and host-related factors can affect its outcome. BACKGROUND: BAHI plays an important role in restoring hearing function. However, implant- and host-related factors contribute to premature implant extrusion. To mitigate this, noninvasive methods to assess implant stability, along with a better understanding of factors contributing to BAHI failure, are needed. METHODS: We evaluated the utility of RFA to quantify implant stability in sawbone (bone mimicking material), 29 human cadaveric samples, and a prospective cohort of 29 pediatric and 27 adult participants, and identified factors associated with implant stability. To validate the use of RFA in BAHI, we compared RFA-derived implant stability quotient (ISQ) estimates to peak loads obtained from mechanical push-out testing. RESULTS: ISQ and peak loads were significantly correlated (Spearman rho = 0.48, p = 0.0088), and ISQ reliably predicted peak load up to 1 kN. We then showed that in cadaveric samples, abutment length, internal table bone volume, and donor age were significantly associated with implant stability. We validated findings in our prospective patient cohort and showed that minimally invasive Ponto surgery (MIPS; versus linear incision), longer implantation durations (>16 wk), older age (>25 yr), and shorter abutment lengths (≤10 mm) were associated with better implant stability. Finally, we characterized the short-term reproducibility of ISQ measurements in sawbone and patient implants. CONCLUSIONS: Together, our findings support the use of ISQ as a measure of implant stability and emphasize important considerations that impact implant stability, including surgical method, implant duration, age, and abutment lengths.


Asunto(s)
Audífonos , Análisis de Frecuencia de Resonancia , Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Niño , Adolescente , Estudios Prospectivos , Prótesis Anclada al Hueso , Adulto Joven , Anciano , Anclas para Sutura , Cadáver
5.
Arch Orthop Trauma Surg ; 144(6): 2683-2689, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38693287

RESUMEN

INTRODUCTION: Arthroscopic revision anterior shoulder instability repair has been proposed, and early clinical results have been promising. However, long-term results after this procedure and the probable risk factors for failure have not been sufficiently discussed in the literature. MATERIALS AND METHODS: Thirty-eight patients who were diagnosed with recurrent anteroinferior shoulder instability after failed Bankart repair, treated with ACRR between September 1998 and November 2003 and able to be contacted were included. Of these patients, 2 were excluded from the study due to the use of SureTak anchors for fixation, and 5 other patients refused to participate in the study due to lack of interest (3 patients) or lack of time (2 patients). The remaining shoulders were clinically examined at a minimum of ten years after surgery via the ASES, Constant, AAOS, Rowe, Dawson and VAS scores for pain and stability. Degenerative arthropathy was assessed with the modified Samilson-Prieto score. RESULTS: All 31 remaining shoulders were evaluated at a mean time of 11.86 years (142.4 months) after surgery. Six patients (19.35%) reported redisolcation after the revision procedure, 4 of whom were affected by a new significant shoulder trauma. The ROWE and Constant scores improved significantly. Moderate to severe dislocation arthropathy was observed in 19.4% of patients. Five patients (16.2%) were not satisfied with the procedure. CONCLUSION: Long-term follow-up after ACRR shows predictable results, with a high degree of patient satisfaction, good to excellent patient-reported outcome scores and minimal radiological degenerative changes. However, with an average recurrence rate of 19.3% after 11.86 years, the redislocation rate appears high. With careful patient selection, recurrence rates can be significantly reduced.


Asunto(s)
Artroscopía , Inestabilidad de la Articulación , Reoperación , Articulación del Hombro , Anclas para Sutura , Humanos , Artroscopía/métodos , Inestabilidad de la Articulación/cirugía , Inestabilidad de la Articulación/etiología , Reoperación/estadística & datos numéricos , Reoperación/métodos , Adulto , Masculino , Femenino , Estudios de Seguimiento , Articulación del Hombro/cirugía , Articulación del Hombro/fisiopatología , Persona de Mediana Edad , Luxación del Hombro/cirugía , Adulto Joven , Insuficiencia del Tratamiento , Adolescente
6.
Am Surg ; 90(6): 1161-1166, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38751046

RESUMEN

BACKGROUND: Blunt traumatic abdominal wall hernias (TAWHs) are rare but require a variety of operative techniques to repair including bone anchor fixation (BAF) when tissue tears off bony structures. This study aimed to provide a descriptive analysis of BAF technique for blunt TAWH repair. Bone anchor fixation and no BAF repairs were compared, hypothesizing increased hernia recurrence with BAF repair. METHODS: A secondary analysis of the WTA blunt TAWH multicenter study was performed including all patients who underwent repair of their TAWH. Patients with BAF were compared to those with no BAF with bivariate analyses. RESULTS: 176 patients underwent repair of their TAWH with 41 (23.3%) undergoing BAF. 26 (63.4%) patients had tissue fixed to bone, with 7 of those reinforced with mesh. The remaining 15 (36.6%) patients had bridging mesh anchored to bone. The BAF group had a similar age, sex, body mass index, and injury severity score compared to the no BAF group. The time to repair (1 vs 1 days, P = .158), rate of hernia recurrence (9.8% vs 12.7%, P = .786), and surgical site infection (SSI) (12.5% vs 15.6%, P = .823) were all similar between cohorts. CONCLUSIONS: This largest series to date found nearly one-quarter of TAWH repairs required BAF. Bone anchor fixation repairs had a similar rate of hernia recurrence and SSI compared to no BAF repairs, suggesting this is a reasonable option for repair of TAWH. However, future prospective studies are needed to compare specific BAF techniques and evaluate long-term outcomes including patient-centered outcomes such as pain and quality of life.


Asunto(s)
Herniorrafia , Mallas Quirúrgicas , Heridas no Penetrantes , Humanos , Masculino , Femenino , Heridas no Penetrantes/cirugía , Herniorrafia/métodos , Adulto , Persona de Mediana Edad , Traumatismos Abdominales/cirugía , Anclas para Sutura , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento , Hernia Ventral/cirugía , Hernia Abdominal/cirugía , Hernia Abdominal/etiología , Puntaje de Gravedad del Traumatismo , Infección de la Herida Quirúrgica/etiología , Infección de la Herida Quirúrgica/epidemiología
7.
Otol Neurotol ; 45(5): 556-563, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38693091

RESUMEN

OBJECTIVE: To investigate the feasibility of early sound processor loading with two separate bone-anchored hearing aid implants 1 to 2 weeks after implantation. Secondary endpoints included registration of any postoperative complications, skin reactions, and any adverse events. STUDY DESIGN: Prospective, nonrandomized, noncontrolled, multicenter clinical trial. SETTING: Tertiary referral center. PATIENTS: Sixty adult patients, eligible for bone-anchored hearing aid surgery, were enrolled. INTERVENTION: Implantation of the bone-anchored hearing aid implants were done using minimally invasive surgery with tissue preservation. MAIN OUTCOME MEASURE: Implant stability quotient (ISQ) values were recorded using resonance frequency analysis. Follow-ups were scheduled 5 to 12 days, 4 to 8 weeks, 6 months, and 12 months postoperatively. Differences between the lowest ISQ values (ISQ low) over time were analyzed by paired-samples t test with a significance level of 0.05. Skin and soft tissue reactions were assessed according to Holger's classification. RESULTS: Loading time of the Ponto Wide implant was 11.6 ± 1.4 days (SD) in average (median, 12 d; range, 7-19 d). Loading of the Ponto BHX implant was done 9.7 ± 3.5 days (SD) postoperatively (median, 9 d; range, 5-19 d). The implant stability increased significantly during the 12-month study period with both implants. One Ponto BHX implant was lost. Skin and soft tissue reactions were few in both groups. Across all planned follow-up visits, no skin and soft tissue reactions were observed in 86% (Ponto BHX implant) and 85% (Ponto Wide implant). CONCLUSION: Very early loading of sound processors after percutaneous bone-anchored hearing system surgery is safe already 1 to 2 weeks postoperatively.


Asunto(s)
Audífonos , Humanos , Masculino , Femenino , Persona de Mediana Edad , Adulto , Anciano , Estudios Prospectivos , Resultado del Tratamiento , Anclas para Sutura , Prótesis Anclada al Hueso , Implantación de Prótesis/métodos , Adulto Joven , Anciano de 80 o más Años
8.
BMC Musculoskelet Disord ; 25(1): 408, 2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38783272

RESUMEN

BACKGROUND: Tenodesis of the long head of the biceps tendon is frequently performed in shoulder surgery, and all-suture anchors have become more popular as fixation methods. However, uncertainty still exists regarding the ultimate load to failure of all-suture anchors and the best insertion angle at a cortical humeral insertion point. PURPOSE: The purpose of this study was to compare the biomechanical characteristics of three types of all-suture anchors frequently used for biceps tenodesis. In addition, the influence of two different insertion angles was observed in a porcine humeri model. METHODS: The ultimate load to failure and failure mode of three types of all-suture anchors (1.6 FiberTak®, 1.9 FiberTak®, 2.6 FiberTak®, Arthrex®) applicable for subpectoral biceps tenodesis were evaluated at 90° and 45° insertion angles in 12 fresh-frozen porcine humeri. The anchors were inserted equally alternated in a randomized manner at three different insertion sites along the bicipital groove, and the suture tapes were knotted around a rod for pullout testing. In total, 36 anchors were evaluated in a universal testing machine (Zwick & Roell). RESULTS: The 2.6 FiberTak® shows higher ultimate loads to failure with a 90° insertion angle (944.0 N ± 169.7 N; 537.0 N ± 308.8 N) compared to the 1.9 FiberTak® (677.8 N ± 57.7 N; 426.3 N ± 167.0 N, p-value: 0.0080) and 1.6 FiberTak® (733.0 N ± 67.6 N; 450.0 N ± 155.8 N, p-value: 0.0018). All anchor types show significantly higher ultimate loads to failure and smaller standard deviations at the 90° insertion angle than at the 45° insertion angle. The major failure mode was anchor pullout. Only the 2.6 FiberTak® anchors showed suture breakage as the major failure mode when placed with a 90° insertion angle. CONCLUSIONS: All three all-suture anchors are suitable fixation methods for subpectoral biceps tenodesis. Regarding our data, we recommend 90° as the optimum insertion angle. CLINICAL RELEVANCE: The influence of anchor size and insertion angle of an all-suture anchor should be known by the surgeon for optimizing ultimate loads to failure and for achieving a secure fixation.


Asunto(s)
Anclas para Sutura , Tenodesis , Animales , Tenodesis/métodos , Tenodesis/instrumentación , Porcinos , Fenómenos Biomecánicos , Ensayo de Materiales , Músculo Esquelético/cirugía , Músculo Esquelético/fisiopatología , Tendones/cirugía , Tendones/fisiopatología , Modelos Animales , Soporte de Peso
9.
PLoS One ; 19(5): e0302996, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38718026

RESUMEN

The success rate of spinal fusion surgery is mainly determined by the fixation strength of the spinal bone anchors. This study explores the use of an L-shaped spinal bone anchor that is intended to establish a macro-shape lock with the posterior cortical layer of the vertebral body, thereby increasing the pull-out resistance of the anchor. The performance of this L-shaped anchor was evaluated in lumbar vertebra phantoms (L1-L5) across four distinct perpendicular orientations (lateral, medial, superior, and inferior). During the pull-out experiments, the pull-out force, and the displacement of the anchor with respect to the vertebra was measured which allowed the determination of the maximal pull-out force (mean: 123 N ± 25 N) and the initial pull-out force, the initial force required to start motion of the anchor (mean: 23 N ± 16 N). Notably, the maximum pull-out force was observed when the anchor engaged the cortical bone layer. The results demonstrate the potential benefits of utilising a spinal bone anchor featuring a macro-shape lock with the cortical bone layer to increase the pull-out force. Combining the macro shape-lock fixation method with the conventional pedicle screw shows the potential to significantly enhance the fixation strength of spinal bone anchors.


Asunto(s)
Vértebras Lumbares , Fusión Vertebral , Humanos , Vértebras Lumbares/cirugía , Fusión Vertebral/métodos , Fusión Vertebral/instrumentación , Tornillos Pediculares , Fenómenos Biomecánicos , Anclas para Sutura
10.
Otol Neurotol ; 45(5): e435-e442, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38728559

RESUMEN

OBJECTIVE: This study evaluates the clinical outcomes of 807 percutaneous wide-diameter bone-anchored hearing implants (BAHIs) in 701 patients. In addition, it compares patient groups and examines bone conduction device (BCD) usage. STUDY DESIGN: Retrospective cohort study. Mean follow-up period of 3.8 years. SETTING: Tertiary referral center. PATIENTS: All patients implanted with a percutaneous wide-diameter BAHI until December 2020 were included. Patients were divided into age groups, "loading-time" groups, and, if applicable, specific subgroups thought to be at risk for complications postsurgery, e.g., intellectual disability and comorbidities. MAIN OUTCOME MEASURES: Soft tissue reaction, implant survival, revision surgery, and BCD usage. RESULTS: In 9.1% of the 5,188 observations of 807 implants, an adverse soft tissue reaction was reported according to the Holgers' scale. Significantly more (adverse) soft tissue reactions were observed in children and intellectually disabled (ID) patients (p < 0.05). Comorbidity subgroups showed no significant differences in soft tissue reactions. Implant loss percentage, including explantations, was 6.2%. Implant survival was significantly worse in patients with ID (14.1%; p = 0.021). Pediatric age, early loading, or comorbidities did not significantly influence implant survival. At least 592 implants (73.4%) were used for bone conduction hearing, of which 65.4% were used daily. CONCLUSION: Both children and ID patients are more prone to (adverse) soft tissue reactions, ID patients only have a higher risk of implant loss. The rate of implant loss in children seemed to be reduced compared to previous studies and thus more comparable to adults since using wide-diameter implants.


Asunto(s)
Conducción Ósea , Prótesis Anclada al Hueso , Audífonos , Humanos , Masculino , Femenino , Estudios Retrospectivos , Adulto , Niño , Persona de Mediana Edad , Adolescente , Adulto Joven , Anciano , Preescolar , Resultado del Tratamiento , Reoperación/estadística & datos numéricos , Estudios de Seguimiento , Anciano de 80 o más Años , Anclas para Sutura , Complicaciones Posoperatorias/epidemiología
11.
PLoS One ; 19(5): e0302839, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38696506

RESUMEN

PURPOSES: Fractures of the inferior patellar pole, unlike other patellar fractures, present challenges for traditional surgical fixation methods. This article introduces the clinical technique and outcomes of using Kirschner wire tension band combined with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures. METHODS: This retrospective case series study included 14 patients with comminuted inferior patellar pole fractures treated at our institution from September 1, 2020, to April 30, 2022. All patients underwent surgery using the Kirschner wire tension band with anchor screw cross-stitch technique. Follow-up assessments involved postoperative X-rays to evaluate fracture healing, as well as clinical parameters such as healing time, Visual Analog Scale (VAS) scores, range of motion (ROM), and Bostman scores. RESULTS: All patients were followed for an average of over 12 months, with no cases of internal fixation failure. Knee joint stability and function were excellent. X-rays revealed an average healing time of approximately 10.79 ± 1.53 weeks, hospitalization lasted 5.64 ± 1.15 days, surgery took approximately 37.86 ± 5.32 minutes, and intraoperative blood loss was 33.29 ± 8.15 ml. One patient experienced irritation from the internal fixation material. At the final follow-up, the Bostman score averaged 28.29 ± 0.83, knee joint flexion reached 131.07° ± 4.88°, all patients achieved full knee extension, and the VAS score was 0.36 ± 0.63. CONCLUSION: Kirschner wire tension band with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures delivered satisfactory clinical outcomes. This surgical method, characterized by its simplicity and reliability, is a valuable addition to clinical practice.


Asunto(s)
Hilos Ortopédicos , Fijación Interna de Fracturas , Fracturas Conminutas , Rótula , Humanos , Masculino , Femenino , Adulto , Rótula/cirugía , Rótula/lesiones , Fracturas Conminutas/cirugía , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Estudios Retrospectivos , Persona de Mediana Edad , Rango del Movimiento Articular , Resultado del Tratamiento , Fracturas Óseas/cirugía , Curación de Fractura , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Adulto Joven , Tornillos Óseos , Anclas para Sutura
12.
Musculoskelet Surg ; 108(2): 153-162, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38713360

RESUMEN

PURPOSE: It is unclear which triceps tendon repair constructs and techniques produce the strongest biomechanical performance while minimizing the risk of gap formation and repair failure. We aimed to determine associations of construct and technique variables with the biomechanical strength of triceps tendon repairs. PubMed, Embase, Cochrane Library, Web of Science, Scopus, and ClinicalTrials.gov were systematically searched for peer-reviewed studies on biomechanical strength of triceps tendon repairs in human cadavers. 6 articles met the search criteria. Meta-regression was performed on the pooled dataset (123 specimens). Outcomes of interest included gap formation, failure mode, and ultimate failure load. Covariates were fixation type; number of implants; and number of sutures. Stratification by covariates was performed. We found no association between fixation type and ultimate failure load; however, suture anchor fixation was associated with less gap formation compared with transosseous direct repair (ß = - 1.1; 95% confidence interval [CI]:- 2.2, - 0.04). A greater number of implants was associated with smaller gap formation (ß = - 0.77; 95% CI: - 1.3, - 0.28) while a greater number of sutures was associated with higher ultimate failure load ( ß= 3; 95% CI: 21, 125). In human cadaveric models, the number of sutures used in triceps tendon repairs may be more important than the fixation type or number of implants for overall strength. If using a transosseous direct repair approach to repair triceps tendon tears, surgeons may choose to use more sutures in their repair in order to balance the risk of larger gap formation when compared to indirect repair techniques. LEVEL OF EVIDENCE: Level III.


Asunto(s)
Cadáver , Técnicas de Sutura , Traumatismos de los Tendones , Humanos , Fenómenos Biomecánicos , Anclas para Sutura , Traumatismos de los Tendones/cirugía , Tendones/cirugía
13.
BMC Musculoskelet Disord ; 25(1): 355, 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38704523

RESUMEN

BACKGROUND: While suture anchors are widely used in medical procedures for their advantages, they can sometimes lead to complications, including anchor prolapse. This article presents a unique case of suture anchor prolapse at the base of the distal phalanx of the little finger after extensor tendon rupture reconstruction surgery. CASE PRESENTATION: A 35-year-old male, underwent extensor tendon rupture reconstruction using a non-absorbable suture anchor. After seven years the patient visited our outpatients complaining of stiffness, pain, and protrusion at the surgical site. Initial X-ray imaging suggested suggesting either a fracture of the distal phalanx or tendon adhesion but lacked a definitive diagnosis. Subsequent magnetic resonance imaging (MRI) revealed bone connectivity between the middle and distal phalanges with irregular signal shadow and unclear boundaries while maintaining a regular finger shape. MRI proved superior in diagnosing prolapsed suture anchors, marking the first reported case of its kind. Surgical intervention confirmed MRI findings. CONCLUSIONS: Suture anchor complications, such as prolapse, are a concern in medical practice. This case underscores the significance of MRI for accurate diagnosis and the importance of tailored surgical management in addressing this uncommon complication.


Asunto(s)
Imagen por Resonancia Magnética , Anclas para Sutura , Traumatismos de los Tendones , Humanos , Masculino , Adulto , Anclas para Sutura/efectos adversos , Traumatismos de los Tendones/cirugía , Traumatismos de los Tendones/diagnóstico por imagen , Rotura/cirugía , Rotura/diagnóstico por imagen , Prolapso , Traumatismos de los Dedos/cirugía , Traumatismos de los Dedos/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/diagnóstico por imagen
14.
BMJ Case Rep ; 17(4)2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38649242

RESUMEN

We present a case of a fit man in his 50s, with simultaneous bilateral quadriceps tendon repair of injuries sustained 6 years apart. Spontaneous closed ruptures of the quadriceps tendon are uncommon. Clinical data of a single case of bilateral quadriceps tendon injury with simultaneous repair was gathered via the patient, notes and surgeon. Diagnosis was primarily based on history and clinical examination. Suggestive features on the plain radiographic imaging were also present. Confirmation was attempted using ultrasonography but yielded conflicting reports. The patient was screened for any associated predisposing conditions that would preclude surgical intervention or increase risk of recurrence. Repairs were accomplished by employing a combination of suture anchors and transpatellar cerclage reinforcement. Apposition of the tendon to the superior patellar pole was successful although with decreased passive flexion on the neglected side (approximately 30°) compared with the acute (approximately 90°). Follow-up continues with postoperative rehabilitation.


Asunto(s)
Músculo Cuádriceps , Traumatismos de los Tendones , Humanos , Masculino , Traumatismos de los Tendones/cirugía , Traumatismos de los Tendones/diagnóstico por imagen , Traumatismos de los Tendones/diagnóstico , Músculo Cuádriceps/lesiones , Músculo Cuádriceps/cirugía , Músculo Cuádriceps/diagnóstico por imagen , Persona de Mediana Edad , Rotura/cirugía , Anclas para Sutura , Traumatismos de la Rodilla/cirugía , Traumatismos de la Rodilla/diagnóstico por imagen
15.
Am J Sports Med ; 52(6): 1428-1438, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38619003

RESUMEN

BACKGROUND: Rotator cuff tears have been repaired using the transosseous method for decades. The direct suture (DS) technique has been widely used for rotator cuff tears; however, the retear rate is relatively high. Suture anchors are now used frequently for rotator cuff repair (RCR) in accordance with recent developments in materials. However, polyether ether ketone (PEEK) may still cause complications such as the formation of cysts and osteophytes. Some studies have developed the inlay suture (IS) technique for RCR. PURPOSE/HYPOTHESIS: To compare how 3 different surgical techniques-namely, the DS, IS, and PEEK suture anchor (PSA)-affect tendon-bone healing after RCR. We hypothesized that the IS technique would lead to better tendon-to-bone healing and that the repaired structure would be similar to the normal enthesis. STUDY DESIGN: Controlled laboratory study. METHODS: Acute infraspinatus tendon tears were created in 36 six-month-old male rabbits, which were divided into 3 groups based on the technique used for RCR: DS, IS, and PSA. Animals were euthanized at 6 and 12 weeks postoperatively and underwent a histological assessment and imaging. The expression of related proteins was demonstrated by immunohistochemistry and immunofluorescence staining. Mechanical properties were evaluated by biomechanical testing. RESULTS: At 12 weeks, regeneration of the enthesis was observed in the 3 groups. However, the DS group showed a lower type I collagen content than the PSA and IS groups, which was similar to the results for scleraxis. The DS group displayed a significantly inferior type II collagen expression and proteoglycan deposition after safranin O/fast green and sirius red staining. With regard to runt-related transcription factor 2 and alkaline phosphatase, the IS group showed upregulated expression levels compared with the other 2 groups. CONCLUSION: Compared with the DS technique, the PSA and IS techniques contributed to the improved maturation of tendons and fibrocartilage regeneration, while the IS technique particularly promoted osteogenesis at the enthesis. CLINICAL RELEVANCE: The IS and PSA techniques may be more beneficial for tendon-bone healing after RCR.


Asunto(s)
Benzofenonas , Cetonas , Polietilenglicoles , Polímeros , Lesiones del Manguito de los Rotadores , Manguito de los Rotadores , Anclas para Sutura , Técnicas de Sutura , Animales , Conejos , Masculino , Lesiones del Manguito de los Rotadores/cirugía , Manguito de los Rotadores/cirugía , Cicatrización de Heridas , Modelos Animales de Enfermedad
16.
Knee Surg Sports Traumatol Arthrosc ; 32(6): 1615-1621, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38578228

RESUMEN

PURPOSE: The safety and reliability of endoscopic Achilles tendon rupture repair are still concerning aspects. This study's aim is to evaluate an all-inside endoscopic semiautomatic running locked stitch (Endo-SARLS) technique. METHODS: Forty cases with acute Achilles tendon rupture were treated with the all-inside Endo-SARLS technique between 2020 and 2021. Under endoscopic control, the proximal tendon stumps were stitched with the running locked method using a semiautomatic flexible suture passer. The threads of the high-strength suture were grasped through the paratenon subspace and then fixed into calcaneal insertion with a knotless anchor. Magnetic resonance imaging (MRI), surgical time and complications were assessed. Achilles Tendon Total Rupture Score (ATRS), Achilles Tendon Resting Angle (ATRA) and Heel Rise Height Scale (HRHS) were utilised to evaluate final outcomes. RESULTS: The average follow-up time was 25.4 ± 0.4 (range: 24-32) months. Appropriate tendon regeneration was observed on MRI after 12 months. At the final follow-up, the median value of ATRS score was 95 (interquartile range: 94, 98). Furthermore, there is no significant difference between the injured and contralateral side in the average ATRA (18.2 ± 1.8 vs. 18.3 ± 1.9°, ns) and median value of HRHS [14.5 (13.3, 15.5) vs. 14.8 (13.5, 15.6) cm, ns]. No infection and nerve injuries were encountered. Thirty-nine patients reported that they resumed casual sports activity after 6 months. One patient had a slight anchor cut-out, due to an addition injury, which was removed after 5 months. CONCLUSIONS: An all-inside Endo-SARLS technique showed promising clinical results for acute Achilles tendon ruptures. This procedure reduces the risk of sural nerve injuries while establishing a reliable connection between the tendon stumps. LEVEL OF EVIDENCE: Level IV.


Asunto(s)
Tendón Calcáneo , Técnicas de Sutura , Traumatismos de los Tendones , Humanos , Tendón Calcáneo/cirugía , Tendón Calcáneo/lesiones , Masculino , Rotura/cirugía , Femenino , Adulto , Traumatismos de los Tendones/cirugía , Persona de Mediana Edad , Imagen por Resonancia Magnética , Endoscopía/métodos , Anclas para Sutura , Resultado del Tratamiento , Estudios Retrospectivos
17.
Medicine (Baltimore) ; 103(14): e37700, 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38579089

RESUMEN

RATIONALE: The nonunion of olecranon fractures is uncommon in simple fractures, and it is challenging to treat surgically due to the disruption of the anatomy of the elbow joint. There is limited literature on surgical options, and several factors to determine the treatment, including the amount and quality of bone stock, age, and degree of articular damage. PATIENT CONCERNS: A 58-year-old man presented at the clinic with neglected olecranon fracture for 1 year (case 1). A 74-year-old man (case 2) presented with consistent pain and limited of motion after surgery for olecranon fracture. DIAGNOSIS: Both patients were diagnosed with olecranon nonunion. INTERVENTION: Both patients received the excision of nonunited fragment and reattaching with V-Y advancement of triceps. OUTCOMES: Range of motion and Mayo elbow performance score were improved after surgery. LESSONS: This technique is useful in patients who cannot undergo other surgical options due to insufficient bone quality and elbow function, and it can lead to satisfactory outcomes with an acceptable range of motion and pain relief.


Asunto(s)
Articulación del Codo , Fractura de Olécranon , Olécranon , Fracturas del Cúbito , Masculino , Humanos , Persona de Mediana Edad , Anciano , Articulación del Codo/cirugía , Olécranon/cirugía , Anclas para Sutura , Fijación Interna de Fracturas/métodos , Fracturas del Cúbito/cirugía , Dolor , Resultado del Tratamiento , Rango del Movimiento Articular
18.
J ISAKOS ; 9(3): 422-425, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38453020

RESUMEN

Partial articular supraspinatus tendon avulsion (PASTA) lesions, a subset of partial rotator cuff tears, pose a surgical challenge, disrupting the integrity of the supraspinatus tendon. Transtendinous repair is the preferred choice in young individuals for limiting tear progression and preserving intact, high-quality cuff tissue, thus preventing tendon shortening, as compared to the tear completion and repair technique. Our approach leverages these advantages, specifically those indicated for Ellman's Grade 3 tears and cases where conservative treatments have failed. In our technique, we employ progressive dilation, anchor drill sleeve insertion to facilitate medial row anchor placement, followed by percutaneous spinal needles for suture shuttling, and finally locking sliding knots for compressive medial row repair, followed by lateral row fixation for additional stability. This method accelerates rehabilitation and restores optimal shoulder function.


Asunto(s)
Artroscopía , Lesiones del Manguito de los Rotadores , Técnicas de Sutura , Humanos , Artroscopía/métodos , Lesiones del Manguito de los Rotadores/cirugía , Manguito de los Rotadores/cirugía , Articulación del Hombro/cirugía , Masculino , Anclas para Sutura , Resultado del Tratamiento , Traumatismos de los Tendones/cirugía , Femenino , Rango del Movimiento Articular
19.
J Hand Surg Eur Vol ; 49(5): 534-545, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38488512

RESUMEN

There is no consensus on the best surgical technique for treating thumb ulnar collateral ligament (UCL) ruptures. This systematic review and meta-analysis investigates which primary repair technique and postoperative immobilization protocol result in the best clinical outcomes. A literature search was conducted in Embase, Medline ALL Ovid, Web of Science Core Selection and Cochrane Central Register of Controlled Trials. Pain, stability, tip pinch strength, key pinch strength, grip strength, return to work and metacarpophalangeal joint range of motion were collected as postoperative outcomes. In total, 29 studies were included. All surgical techniques resulted in satisfactory clinical outcomes, with no significant differences between bone anchor reinsertion, suture fixation, K-wire fixation and a combination of techniques. K-wire immobilization resulted in worse postoperative pain, but similar stability compared to immobilization without a K-wire. Clinical outcomes after thumb UCL repair are excellent, with no differences in clinical outcomes noted among surgical techniques.


Asunto(s)
Hilos Ortopédicos , Ligamento Colateral Cubital , Pulgar , Humanos , Ligamento Colateral Cubital/cirugía , Ligamento Colateral Cubital/lesiones , Pulgar/cirugía , Pulgar/lesiones , Rotura/cirugía , Fuerza de la Mano , Rango del Movimiento Articular , Anclas para Sutura , Resultado del Tratamiento , Reconstrucción del Ligamento Colateral Cubital
20.
Orthop Surg ; 16(5): 1073-1078, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38488263

RESUMEN

OBJECTIVES: Bankart lesion is one of the most common lesions of the glenohumeral joint. Several double-row suture methods were reported for Bankart repair, which could provide more stability, yet more motion limitation and complications. Therefore, we introduced a new double-row Bankart repair technique, key point double-row suture which used one anchor in the medial line. The purpose of this article is to investigate the clinical outcomes of this new method and to compare it with single-row suture. METHODS: Seventy-eight patients receiving key point double-row suture or single-row suture from October 2010 to June 2014 were collected retrospectively. The basic information including gender, age, dominant arm, and number of episodes of instability was collected. Before surgery, the glenoid bone loss was measured from the CT scan. The visual analogue scale, American shoulder and elbow surgeons, the University of California at Los Angeles shoulder scale, and subjective shoulder value were valued before surgery and at the last follow-up. RESULTS: Forty-four patients (24 patients receiving single-row suture and 20 patients receiving key point double-row suture) were followed up successfully. The follow-up period was 9.2 ± 1.1 years (range, 7.8-11.4 years). At the last follow-up, no significant differences were detected for any of the clinical scores. The recurrence rate was 12.5% for the single-row group and 10% for the double-row group, respectively (p = 0.795) 14 patients (31.8%) in the single-row group and nine patients (26.5%) in the double-row group were tested for active range of motion. A statistically significant difference was found only for the internal rotation at 90° abduction (48.9° for single-row and 76.7° for key point double-row, p = 0.033). CONCLUSION: The key point double-row sutures for Bankart lesions could achieve similar long-term outcomes compared with single-row suture, and one medial anchor did not result in a limited range of motion. The low recurrence rate and previous biomechanical results also indicate the key point double-row suture is a reliable method.


Asunto(s)
Inestabilidad de la Articulación , Técnicas de Sutura , Humanos , Femenino , Masculino , Adulto , Estudios Retrospectivos , Estudios de Casos y Controles , Inestabilidad de la Articulación/cirugía , Inestabilidad de la Articulación/fisiopatología , Lesiones de Bankart/cirugía , Rango del Movimiento Articular/fisiología , Adulto Joven , Articulación del Hombro/cirugía , Articulación del Hombro/fisiopatología , Persona de Mediana Edad , Adolescente , Anclas para Sutura , Artroscopía/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA